• Title/Summary/Keyword: 속도 필터

Search Result 1,154, Processing Time 0.03 seconds

Gender Differences of Susceptibility to Lung Cancer According to Smoking Habits (흡연습관에 따른 폐암발생 감수성에 대한 성별의 차이)

  • Choi, Chung-Kyoung;Shin, Kyeong-Cheol;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.5
    • /
    • pp.576-584
    • /
    • 2000
  • Background : With the increase of cigarette consumption by women and the young, the incidence of lung cancer is expected to increase during the next three or four decades in Korea. The purpose of this study was to analyze the smoking habits in patients with lung cancer and to identify the gender differences in terms of their susceptibility to cigarette related carcinogens. Method : This investigation was a hospital-based case control study, which included the data of 178 case subjects (72 females, 106 males) with lung cancer and 218 control subjects (97 females, 121 males) with diseases unrelated to smoking. The information was obtained through a direct personal interview and a questionnaire related to personal smoking history. Results : The relative frequency of the squamous cell carcinoma was substantially higher in males than in females (61.3% in males, and 29.2% in females), while adenocarcinoma including bronchoalveolar cell carcinoma was higher in females(31.9% in females, 18.9% in males). Kreyberg I lung cancer was of relatively higher frequencies in males and smokers, while Kreyberg II lung cancer was higher in females and never smokers. The odds ratios (ORs) at each exposure level were consistently higher in females than males. For all cell types, the risk of lung cancer was increased with the quantity of smoked cigarettes, duration of smoking, and depth of inhalation. Odds ratio was distinctly higher in Kreyberg I lung cancer than in total lung cancer and a steeper gradient of risk with increased smoking was observed in females. Conclusion : The relative risk for lung cancer was consistently higher in females than in males at every level of exposure to cigarette smoke. This is believed to be due to the higher susceptibility of females to tobacco carcinogens, such as gender associated differences of carcinogen activation and/or the elimination of smoking related metabolites.

  • PDF

2-D/3-D Seismic Data Acquisition and Quality Control for Gas Hydrate Exploration in the Ulleung Basin (울릉분지 가스하이드레이트 2/3차원 탄성파 탐사자료 취득 및 품질관리)

  • Koo, Nam-Hyung;Kim, Won-Sik;Kim, Byoung-Yeop;Cheong, Snons;Kim, Young-Jun;Yoo, Dong-Geun;Lee, Ho-Young;Park, Keun-Pil
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.127-136
    • /
    • 2008
  • To identify the potential area of gas hydrate in the Ulleung Basin, 2-D and 3-D seismic surveys using R/V Tamhae II were conducted in 2005 and 2006. Seismic survey equipment consisted of navigation system, recording system, streamer cable and air-gun source. For reliable velocity analysis in a deep sea area where water depths are mostly greater than 1,000 m and the target depth is up to about 500 msec interval below the seafloor, 3-km-long streamer and 1,035 $in^3$ tuned air-gun array were used. During the survey, a suite of quality control operations including source signature analysis, 2-D brute stack, RMS noise analysis and FK analysis were performed. The source signature was calculated to verify its conformity to quality specification and the gun dropout test was carried out to examine signature changes due to a single air gun's failure. From the online quality analysis, we could conclude that the overall data quality was very good even though some seismic data were affected by swell noise, parity error, spike noise and current rip noise. Especially, by checking the result of data quality enhancement using FK filtering and missing trace restoration technique for the 3-D seismic data inevitably contaminated with current rip noises, the acquired data were accepted and the field survey could be conducted continuously. Even in survey areas where the acquired data would be unsuitable for quality specification, the marine seismic survey efficiency could be improved by showing the possibility of noise suppression through onboard data processing.

Enhancement of Inter-Image Statistical Correlation for Accurate Multi-Sensor Image Registration (정밀한 다중센서 영상정합을 위한 통계적 상관성의 증대기법)

  • Kim, Kyoung-Soo;Lee, Jin-Hak;Ra, Jong-Beom
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.4 s.304
    • /
    • pp.1-12
    • /
    • 2005
  • Image registration is a process to establish the spatial correspondence between images of the same scene, which are acquired at different view points, at different times, or by different sensors. This paper presents a new algorithm for robust registration of the images acquired by multiple sensors having different modalities; the EO (electro-optic) and IR(infrared) ones in the paper. The two feature-based and intensity-based approaches are usually possible for image registration. In the former selection of accurate common features is crucial for high performance, but features in the EO image are often not the same as those in the R image. Hence, this approach is inadequate to register the E0/IR images. In the latter normalized mutual Information (nHr) has been widely used as a similarity measure due to its high accuracy and robustness, and NMI-based image registration methods assume that statistical correlation between two images should be global. Unfortunately, since we find out that EO and IR images don't often satisfy this assumption, registration accuracy is not high enough to apply to some applications. In this paper, we propose a two-stage NMI-based registration method based on the analysis of statistical correlation between E0/1R images. In the first stage, for robust registration, we propose two preprocessing schemes: extraction of statistically correlated regions (ESCR) and enhancement of statistical correlation by filtering (ESCF). For each image, ESCR automatically extracts the regions that are highly correlated to the corresponding regions in the other image. And ESCF adaptively filters out each image to enhance statistical correlation between them. In the second stage, two output images are registered by using NMI-based algorithm. The proposed method provides prospective results for various E0/1R sensor image pairs in terms of accuracy, robustness, and speed.

Comparison of Antioxidant Activities of Enzymatic and Methanolic Extracts from Ecklonia cava Stem and Leave (감태(Ecklonia cava) 줄기 및 잎의 효소적 추출물과 메탄올 추출물에 의한 항산화 활성비교)

  • Lee, Seung-Hong;Kim, Kil-Nam;Cha, Seon-Heui;Ahn, Gin-Nae;Jeon, You-Jin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.9
    • /
    • pp.1139-1145
    • /
    • 2006
  • In this study, antioxidant activities of enzymatic and methanolic extracts from E. cava stem and leave were evaluated by measuring the scavenging activities on 1,1 diphenyl 2 picrylhydrazyl (DPPH), hydroxyl radical, hydrogen peroxide and the inhibitory effects on DNA damage induced by oxidative stress of cells. Enzymatic extracts were prepared by enzymatic hydrolysis of both stem and leave using food grade five different carbohydrases (Viscozyme, Celluclast, AMG, Termamyl, Ultraflo) and five proteases (Protamex, Kojizyme, Neutrase, Flavourzyme, Alcalase). The enzymatic extracts were lower than methanolic extracts in polyphenol contents, but higher in extraction yield by approximately 30%. The enzymatic extracts were superior to methanolic extracts in DPPH and H2O2 scavenging activities and DNA damage protective effect. There were no significant antioxidant activity difference between stem and leave, but the extracts of leave were relatively better than those of stem. In this study it is suggested that E. cava stem as well as its leave would be a good raw materials for antioxidants compound extraction and enzymatic hydrolysis would be a good strategy to prepare antioxidant extracts from seaweeds.