• Title/Summary/Keyword: 속도펄스

Search Result 373, Processing Time 0.022 seconds

Torsional Vibration Phenomenon due to Pulse Torque of Variable Speed Induction Motor on Rotating Systems (가변 속도 유도 전동기에서 발생한 펄스 토크에 의한 회전축계의 비틀림진동 현상)

  • Lee, Donchool;Vuong, QuangDao;Nam, Taekkun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.6
    • /
    • pp.414-419
    • /
    • 2015
  • Recently, commercial ships and other specialized vessels with electric propulsion system employ variable speed induction motor as its prime mover. The wide application of electrical motors also includes being the main drive system in most industrial machineries. However, during its start-up, shutdown, and brake switch operation, excessive torque variation are generated. As such, flexible coupling are installed in order to reduce the transmitted torque fluctuation to the driven side. In this paper, the pulse torque generated by an variable speed induction motor was analyzed theoretically and through measurement of torsional vibration. Induction motor with inverter on marine propulsion system and industrial compressor were used as experimental subjects. The study confirmed that pulse torque are generated regardless of motor speed and interpreted as a vibration source of the whole system. Results presented herein can be adopted as the basis in future amendment of inspection classifying body regulations.

Analysis on the PMD compensator's limitation from PDL in the optical communication system (광통신 시스템에서 PDL로 인한 PMD 보상 수준 한계에 대한 연구)

  • 김나영;이덕기;윤호성;박남규
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.1
    • /
    • pp.32-39
    • /
    • 2001
  • We analyze the effectiveness of the PMD compensation as a function of the link PDL, to acquire the guidelines for the successful deployment of PMDC. Result shows that the amount of BER improvement from the PMDC is decreased as the link PDL increases. Because PDL elements in the transmission system make well-defined two PSPs under the absence of PDL not orthogonal anymore, and proper definition of fast and slow polarization harder. Accordingly, consideration of PDL's potential effects must be needed for design of polarization mode dispersion compensation.sation.

  • PDF

Phenol Conversion Properties in Aqueous Solution by Pulsed Corona Discharge (펄스 코로나 방전에 의한 액체상 페놀 전환 특성)

  • Lee, Hyun-Don;Chung, Jae-Woo;Cho, Moo-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.40-46
    • /
    • 2007
  • A laboratory scale experiment on phenol conversion properties by pulsed corona discharge process was carried out. Effects of operating parameters such as applied voltage, input oxygen, and electrode geometry on phenol conversion and solution properties were investigated. Electrical discharges generated in liquid phase increased the liquid temperature by heat transfer from current flow, decreased the pH value by producing various organic acids from phenol degradation, and increased conductivity by generating charge carriers and organic acids. The oxygen supply enhanced the phenol conversion through the ozone generation dissolution and the production of OH radicals. Series type electrode configuration induced more ozone production than reference type configuration because it produced gas phase discharges as well as liquid phase discharges. Therefore, the higher phenol conversion and TOC(total organic carbon) removal efficiency were obtained in series type configuration.

A Study of Range Resolving Performance for Airborne Radar Based on Signal Processing and Tracking Algorithm (신호처리 및 추적 알고리즘을 고려한 항공기탑재 레이다 거리 분해 성능 검증)

  • Yeonhee Pak;Yong-min Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.5
    • /
    • pp.568-573
    • /
    • 2023
  • Range resolution is the ability to distinguish different targets placed in same angular direction but at different distances from the radar. Normally, Range resolution requirement is defined as the width of transmitting pulse. The width of transmitting pulse does not mean the ability to distinguish two different targets. Range resolution performance to detect and track targets separately depends on the signal processing and tracking algorithm not only the width of transmitting pulse. This paper analyzes the processing steps in algorithms to affect the range resolution performance and verifies the results by roof-lab ground test using beacon signal. As a result, to track targets with the same angular position separately, it is desirable to have larger range difference than plot-track association test gate.

Treatment of Heavy Metals and Phenol in Contaminated Soil Using Direct Current and Pulse Voltage (직류 전원과 펄스 전원을 이용하여 오염된 토양에서의 중금속과 페놀 처리)

  • Choi, Changsik;Hong, Bumeui;Choi, Hee Young;Lee, Eunsil;Choi, Suk Soon
    • Applied Chemistry for Engineering
    • /
    • v.27 no.6
    • /
    • pp.606-611
    • /
    • 2016
  • In this work, the treatment of heavy metals and phenol in the contaminated soil was investigated by applying direct current (DC) and pulse voltage. When the DC was used, the removal efficiencies for Cu, Zn, As, and Pb were 73, 88, 10, and 10%, respectively, and more than 95% for phenol was removed. Furthermore, when a pulse voltage was employed the removal efficiencies for Cu, Zn, As, and Pb were 88, 92, 40, and 40%, respectively, and 87% of phenol was removed. The results indicate that the application of a pulse voltage for the treatment of contaminated soil reduced electro-osmosis, but increased the rate of electric current movement of heavy metals. In addition, the removal efficiencies for As and Pb have been improved due to the enhanced adsorption capacity of clay components in the soil. Therefore, these experimental results could be effectively applied in remediation technology for the treatment of various heavy metals and phenol.

Performance Test of a Single Pulse Gun for Transverse Pressure Wave Generation (횡단압력파 발생을 위한 단일 펄스건의 압력파 성능시험)

  • Lee, Jongkwon;Song, Wooseok;Koo, Jaye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.8
    • /
    • pp.599-606
    • /
    • 2019
  • The pulse gun device is designed to identify the transverse pressure wave propagation/damping mechanism into the combustion flow field and in the combustion chamber according to the arrangement of multiple injectors. The manufactured pulse gun was tested to verify operability at the target combustion pressure and control of the pressure wave intensity. Gas nitrogen was used to pressurize the high-pressure tube and an OHP film of $100{\mu}m$ thickness was used for the diaphragm. To check the speed and intensity of the pressure waves, the dynamic and static pressure were measured using the pressure transducer. The performance test confirmed that the manufactured pulse gun can generate pressure waves with transverse characteristics that can be controled for strength depending on the supply pressure.

Dynamics of Rouleaux Patterns of Red Blood Cells under Pulse Magnetic Field (강한 펄스자기장 자극에 의한 적혈구 연전현상의 활동성 조사)

  • Hwang, Do Guwn
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.3
    • /
    • pp.92-97
    • /
    • 2017
  • It is widely known that pulsed magnetic field (PMF) is very useful tool to manipulate chemical and physiological processes in human body. The purpose of our study is to observe dynamics of rouleaux patterns of red blood cells (RBC) under PMF. The aggregation of RBCs or rouleaux formation is caused by fibrinogen in blood plasma. The maximum magnetic field intensity is 0.27 T and pulse time of 0.102 msec and pulse repetition rate was 1 Hz. PMF stimulus was applied to the palm of left hand for 5, 10, 15 and 20 min. Live blood analysis was used in vitro in order to quantitatively estimate the velocity of RBC exposed to PMF stimulus. The velocity of stacked-RBC of 10 minute PMF stimulus was increased up to $8{\times}10^{-4}m/sec$, but it decreased rapidly as the time passed. The results of present study have adduced that PMF stimulus on hand provide the improvement of RBC rouleaux formation, increase of RBC's moving velocity as well as low blood viscosity.

A Development of Pulse Oximeter module for Measurement of $SpO_2$ (산소포화도 측정을 위한 모듈형 펄스 옥시메터 개발)

  • 이한욱;이주원;이종회;조원래;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.3
    • /
    • pp.575-583
    • /
    • 2000
  • Pulse oximetry is a well established non-invasive optical technique for monitoring the $SpO_2$ during anaesthesia, recovery and intensive care. Pulse oximeters determine the oxygen saturation level of blood by measuring the light absorption of arterial blood. In the measurement of the hemoglobin oxygen saturation, conventional method has required the technique of filtering of remove the noise, and of complex signal processing algorithm. So much time have been required to signal processing. In this research, we separate AC signal and DC signal in the stage of signal detection. Therefore we simplify the calculation algorithm for $SpO_2$. The implemented system have the high performance such an accuracy and a processing time than the traditional method.

  • PDF

Development of FROG Hardware and Software System for the Measurement of Femto-Seconds Ultrashort Laser Pulses (지속시간 펨토초 수준의 빛펄스틀 재는 이차조화파발생 프로그(SHG FROG) 장치 개발)

  • 양병관;김진승
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.278-284
    • /
    • 2004
  • A Second Harmonic Generation Frequency Resolved Optical Gating(SHG FROG) system was developed. Its performance test shows that it is capable of accurately measuring the temporal evolution of the electric field, both amplitude and phase, of femtosecond light pulses. For the retrieval of the temporal evolution of light pulses from their spectrograms obtained by using the FROG system, Principal Components Generalized Projection(PCGP) algorithm is used and in addition we used additional constraints of second-harmonic spectrum, marginals in frequency and time-delay of the spectrogram. Such modification of the software brings about significant improvement in speed and stability of the pulse retrieval process.

Analysis of High Resolution Range Estimation for Moving Target Using Stepped Frequency Radar with Coherent Pulse Train (코히어런트 펄스열을 갖는 계단 주파수 레이더를 이용한 이동표적의 고해상도 거리 추정 분석)

  • Sim, Jae-Hun;Bae, Keun-Sung
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.599-604
    • /
    • 2018
  • A Stepped Frequency Radar(SFR) is a method that realizes high resolution range estimation by increasing the frequency of transmission pulses at regular intervals to generate a wide synthetic bandwidth. However, in the case of a moving target, accurate range estimation becomes difficult due to the range-Doppler coupling. In this paper, the process of high resolution range estimation by compensation of the range-Doppler coupling with estimated velocity of the moving target using the SFR waveform with Coherent Pulse Train(CPT) is analyzed and it was verified through simulation.