• Title/Summary/Keyword: 속기

Search Result 265, Processing Time 0.027 seconds

Ab-initio Calculations of Mg Silicate and (hydr)oxide Core-level Absorption Spectra (Mg 규산염 및 (수)산화물에 대한 제일원리 내각준위 흡수 스펙트럼 계산 연구)

  • Son, Sangbo;Kwon, Kideok D.
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.2
    • /
    • pp.121-131
    • /
    • 2021
  • Magnesium (Mg) present in carbonate minerals as impurities has been used as a geochemical proxy to infer the environmental conditions where the minerals precipitated. The reliability of Mg geochemical proxies requires fundamental understanding of Mg incorporation into minerals based on accurate speciation of Mg 2+ in the crystal structure, which is determined mainly by application of X-ray absorption spectroscopy (XAS). However, high uncertainties are involved in interpreting the XAS spectra of minerals containing trace amount of Mg 2+. Because density function theory (DFT) can predict an XAS spectrum for a crystal structure, DFT calculations can reduce the uncertainties in the interpretation of the XAS spectrum. In this study, we calculated ab initio Mg K-edge absorption spectra of Mg silicates and (hydr)oxides based on DFT and analyzed the correlation between the calculated spectra and Mg structural parameters. Our ab initio Mg K-edge absorption spectra well reproduced the key features of the experimental spectra. The absorption-edge positions of the calculated spectra showed the weak positive correlation with the average Mg-O bond distance or Mg effective coordination number. The current study shows that DFT-based core-level spectroscopy method is a powerful tool in providing standard Mg K-edge spectra of diverse Mg minerals and determining the Mg chemical species within carbonate minerals.

Analysis of Production Status of the 2017 Record (2017년도 기록물 생산현황 분석 중앙행정기관을 중심으로)

  • Park, Ji-tae;Kim, Sung-kyum;Hwang, Jung-won
    • The Korean Journal of Archival Studies
    • /
    • no.57
    • /
    • pp.113-136
    • /
    • 2018
  • Records management refers to a series of activities to achieve the goal of securing transparency in administration and safely preserving and utilizing records. Each process of record management is largely divided into production, preservation and management stage. The reporting system of record production has an important fuction that serves as a bridge between production stage and preservation and management stage. It was established after the enactment of the Act on Records Management of Public Agencies in 1999, to grasp the state of production and management of records of various organizations. Since then the National Archives of Korea(NAK) has been able to rather actively understand the situation of records and acquire them than simply collect them. The Act, which was revised in 2006, regulates electronically automated reporting methods in which the production reporting datas are generated in the record creation system and transferred to the record management system. Despite improvements in the system, electronic reporting methods are being used in part. The 713 public institutions have submitted reports of record production to the NAK in 2017, and this study analyses them of only 47 central administrative agencies, including departments, offices, agencies, and committees. Their reports have 15 forms which consist of production statistics and inventories of 7 types of records including general records, survey, research, review, minutes, shorthand, audiovisual records, secret records, government publications. This suggests implications for improving the reporting system of record production.

A Study on the Measurement of the Relative Nuclear Reaction Cross-Section of the natW(p,xn)176Re Reaction using 100 MeV Proton (100 MeV 양성자를 이용한 natW(p,xn)176Re 핵반응의 상대 핵반응단면적 측정에 대한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.257-263
    • /
    • 2021
  • This study derives the relative cross-section for the natW(p,xn)176Re nuclear reaction by measuring the gamma rays generated from the nuclear reaction with natural tungsten using a 100 MeV linear accelerator of the Korea Multi-purpose Accelerator Complex in the Korea Atomic Energy Research Institute. In general, research on isotopes with a short half-life always shows a tendency that the intensity of radioactivity decreases rapidly within a short period of time, making it very difficult to measure itself. In particular, 176Re is one of the relatively short radionuclides with a half-life of 5.3 minutes. In this study, 109.08 keV gamma rays generated from the 176Re isotope having such a short half-life were measured using a high-purity Ge detector(HPGe detector). The obtained relative measurements were the results in the 8 to 14 MeV proton energy domain published by Richard G. in 1967, and the TENDL-2019 value, which was the result of A. J. Koning in 2019, which evaluated the nuclear reaction cross-section by calculation based on this comparative analysis was performed. The results of this study are expected to be usefully applied to the design of nuclear fusion reactor which is known as future energy sources, elements ratio for the nuclear synthesis of astrophysics.

Comparative Evaluation of Radioactive Isotope in Concrete by Heavy Ion Particle using Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 중하전입자의 콘크리트 방사화 비교평가)

  • Bae, Sang-Il;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.359-365
    • /
    • 2021
  • A heavy particle accelerator is a device that accelerates particles using high energy and is used in various fields such as medical and industrial fields as well as research. However, secondary neutrons and particle fragments are generated by the high-energy particle beam, and among them, the neutrons do not have an electric charge and directly interact with the nucleus to cause radiation of the material. Quantitative evaluation of the radioactive material produced in this way is necessary, but there are many difficulties in actual measurement during or after operation. Therefore, this study compared and evaluated the generated radioactive material in the concrete shield for protons and carbon ions of specific energy by using the simulation code FLUKA. For the evaluation of each energy of proton beam and carbon ion, the reliability of the source term was secured within 2% of the relative error with the data of the NASA Space Radiation Laboratory(NSRL), which is an internationally standardized data. In the evaluation, carbon ions exhibited higher neutron flux than protons. Afterwards, in the evaluation of radioactive materials under actual operating conditions for disposal, a large amount of short-lived beta-decay nuclides occurred immediately after the operation was terminated, and in the case of protons with a high beam speed, more radioactive products were generated than carbon ions. At this time, radionuclides of 44Sc, 3H and 22Na were observed at a high rate. In addition, as the cooling time elapsed, the ratio of long-lived nuclides increased. For nonparticulate radionuclides, 3H, 22Na, and for particulate radionuclides, 44Ti, 55Fe, 60Co, 152Eu, and 154Eu nuclides showed a high ratio. In this study, it is judged that it is possible to use the particle accelerator as basic data for facility maintenance, repair and dismantling through the prediction of radioactive materials in concrete according to the cooling time after operation and termination of operation.

A Comparative Study of Branching Ratio of 167Yb Radioactive Isotope from Gamma-ray Spectrum Produced by 169Tm(p,3n)167Yb Reaction with 100-MeV Proton Beam (100-MeV 양성자 빔을 이용하여 169Tm(p,3n)167Yb 반응에 의해 생성된 167Yb 방사성동위원소에서 방출되는 감마선 스펙트럼 비교 연구)

  • Sam-Yol, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.953-960
    • /
    • 2022
  • The measurement of branching ratio of 167Yb radioactive isotopes from gamma-ray spectrum of 169Tm(p,3n)167Yb reaction were performed by using a 100-MeV proton linear accelerator of the Korea Multi-purpose Accelerator Complex (KOMAC). The 167Yb isotope has a half-life of 17.5 minutes and decays to 169Tm. The gamma rays generated from the 167Yb isotope were measured using an HPGe detector gamma ray spectroscopy system. The energy calibration of the detector and the efficiency measurement of the detector were determined using a standard source. The gamma rays of known main energy (62.9, 106.2, 113.3, 143.5 and 176.3 keV) were measured. On the other hand, information about the intensity of the generated gamma rays is very inaccurate. Therefore, in this study, the decay strength of the main gamma rays was accurately measured. Overall, it was different from the previously known results, and in particular, it was found that the intensity of the main decay gamma ray, such as the 113.3 and 106.2 keV gamma ray, was overestimated, and it was found that the gamma ray, such as 62.9, 116.7 and 143.5 keV was underestimated. The present results are considered to be important information in the fields of nuclear fusion, astrophysics and nuclear physics in the future.

Development of an Automated Synthesizer for the Routine Production of Ga-68 Radiopharmaceuticals (임상용 Ga-68 표지 방사성의약품의 합성을 위한 자동합성장치 개발)

  • Jun Young PARK;Jeongmin SON;Won Jun KANG
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.4
    • /
    • pp.253-260
    • /
    • 2023
  • The germanium-68/gallium-68 (68Ge/68Ga) generator has high spatial utilization and requires little maintenance, making it economical and easy to produce. Thus, the frequency of use of 68Ga radiopharmaceuticals is rapidly increasing worldwide. Therefore, this study attempted to develop an automated synthesizer for the routine clinical application of 68Ga radiopharmaceuticals. The automated synthesizer was based on a fixed tubing system and the structure was designed after adjusting the position of the parts to reflect the synthesis method. Using various components that can be supplied in Korea, the automated synthesizer was manufactured at a much lower price cost than that of a commercialized automated synthesizer sold by companies. 68Ga-DOTA-[Tyr3]-octreotide (68Ga-DOTATOC) was synthesized to evaluate the performance of the automated synthesizer. 68Ga-DOTATOC could be synthesized with about 65% of non-decay corrected yield, and the synthesized 68Ga-DOTATOC met all quality control standards. We have synthesized 68Ga-DOTATOC more than 100 times, and only faced a few problems caused by mechanical errors. In this study, we successfully developed a simple automated synthesizer for 68Ga radiopharmaceuticals with high reproducibility. As various 68Ga radiopharmaceuticals have recently been developed, it is expected that the automated synthesizer developed in this study will be useful for routine clinical use.

Study on Absorbed Dose Determination of Electron Beam Quality for Cross-calibration with Plane-parallel Ionization Chamber (평행평판형이온함의 교차교정 시 전자선 선질에 따른 흡수선량 결정에 대한 연구)

  • Rah, Jeong-Eun;Shin, Dong-Oh;Park, So-Hyun;Jeong, Ho-Jin;Hwang, Ui-Jung;Ahn, Sung-Hwan;Lim, Young-Kyung;Kim, Dong-Wook;Yoon, Myong-Geun;Shin, Dong-Ho;Lee, Se-Byeong;Suh, Tae-Suk;Park, Sung-Yong
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2009
  • Absorbed dose to water based protocols recommended that plane-parallel chambers be calibrated against calibrated cylindrical chambers in a high energy electron beam with $R_{50}$>7 $g/cm^2$ (E${\gtrsim}$16 MeV). However, such high-energy electron beams are not available at all radiotherapy centers. In this study, we are compared the absorbed dose to water determined according to cross-calibration method in a high energy electron beam of 16 MeV and in electron beam energies of 12 MeV below the cross-calibration quality remark. Absorbed dose were performed for PTW 30013, Wellhofer FC65G Farmer type cylindrical chamber and for PTW 34001, Wellhofer PPC40 Roos type plane-parallel chamber. The cylindrical and the plane-parallel chamber to be calibrated are compared by alternately positioning each at reference depth, $Z_{ret}=0.6R_{50}-0.1$ in water phantom. The $D_W$ of plane-parallel chamber are derived using across-calibration method at high-energy electron beams of 16, 20 MeV. Then a good agreement is obtained the $D_W$ of plane-parallel chamber in 12 MeV. The agreement between 20 MeV and 12 MeV are within 0.2% for IAEA TRS-398.

  • PDF

Considering a Few Issues on 'Chobo': Handwritten Chobo's Origin, Name, Discontinuance & Privately Printed Chobo (조보(朝報)에 대한 몇 가지 쟁점: 필사보조의 기원, 명칭, 폐간시기, 기문기사 성격과 민간인쇄조보를 중심으로)

  • Kim, Young-Ju
    • Korean journal of communication and information
    • /
    • v.43
    • /
    • pp.247-281
    • /
    • 2008
  • The purpose of this article is to re-examine the issue of Chobo's origin, which has not been clearly determinated thus far. Also, the research investigates Chobo's name, time point of discontinuance, character of the article on disaster, and civil-printed incident of Chobo during King Sunjo. As an internal bulletin, handwritten Chobo began to come out at the end of 15th century, roughly King Sungjong period of Chosun Dynasty. Systematically developed in the period of King Jungjong, it had continuously been released until November, 1907 when fairly organized and competitive commercial daily newspapers were published and when the office of secretary named Biseogam was abolished. Because handwritten Chobo was exclusive and narrow in its communication nature and difficult to read it's fast handwritten Nancho calligraphic style, in August, 1577 (10th year of King Sunjo) a few civilian in Seoul obtained a permission from authorities (Uijungboo and Sahunboo) published a wooden type printed Chobo. Unfortunately, privately printed Chobo was forced to cease in 3 month because of King Sunjo's oppressive measure. However, considering it was published for a profit by civilian and used the world's first type printing, it is highly probable that Chobo seems to be the world’s first type printing commercial daily newspaper.

  • PDF

Effects of Soil Organic Matter Content on Activity Change, Vertical Migration, and Persistence of Two Nematicides, Carbofuran and Ethoprophos, to Root-Knot Nematode, Meloidogyne incognita (토양중 유기물함량 차이에 따른 고구마뿌리혹선충(Meloidigyne incognita)에 대한 Carbofuran과 Ethoprophos의 효력변동, 수직이동성 및 잔효성조사)

  • Song, Cheol;Hwang, In-Taek;Jang, Kyoung-Soo;Cho, Kwang-Yun
    • Korean journal of applied entomology
    • /
    • v.38 no.1
    • /
    • pp.47-52
    • /
    • 1999
  • Effects of organic matter content in soil on activity. vertical migration. and persistence of two nernaticides. carbofuran and ethoprophos. to root-knot nematode, Mrloitlog!~iei ~lcognita.w ere investigated. As the organic matter content increased. activity of the nernaticides tended to be reduced. Both nematicides exhibited control values of more than 80'k' to M. iix.o,yilit~iln 0-2 cm depth soil layer from the surface. regi~rdless of organic matter content in soil. In 2-4 cm depth soil layer. however. the control value of the neniaticides varied with the organic niatter content in soil. The control value of carbofuran in the soil layer was ranged from I0 to 30'2,. depending on the soil organic niatter content. In contrast. ethoprophos had no control value against M. i/ic.o,ytlitcr in the \oil layer, except that the nematicide had a control value of 30% when the organic matter content was 0.4%. Furthermore. ethoprophos had no effect on controlling M. i/ic.o,gtiitrr in soil layer of below 4cm. whereas control values of carbofuran were approximately from 5 to 20% in all test soils having different organic matter contents. These results indicate that carbofuran has more vertical migration effect than ethoprophos. Persistence of the two neniaticides was also decreased with increasing soil organic matter content. Half life of carbofuran was 2-3 weeks in soil containing 0.4% organic matter, whereas it was found to be I week in soils containning 0.8 ant1 1.6% of organic matter. On the other hand. activity of ethoprophos was reduced to half in 3-3 weeks and in 2-3 weeks in soil containing 0.4 and 0.8%, and 1.6%) of organic matter, respectively. However, no activity of the both nernaticides was found in soil containing 3.2% of organic matter.

  • PDF

Study on the Photoneutrons Produced in 15 MV Medical Linear Accelerators : Comparison of Three-Dimensional Conformal Radiotherapy and Intensity-Modulated Radiotherapy (15 MV 의료용 선형가속기에서 발생되는 광중성자의 선량 평가 - 3차원입체조형방사선치료와 세기조절방사선치료의 비교 -)

  • Yang, Oh-Nam;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.335-343
    • /
    • 2012
  • Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photonueutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photonbeams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.