• Title/Summary/Keyword: 소프트웨어 엔지니어링

Search Result 164, Processing Time 0.021 seconds

Evaluation of Dust Removal Efficiency on Roadway Structures Using Ultrafine Bubble Water Jet (초미세기포 water jet을 이용한 도로 시설물 분진 제거 효율 평가)

  • Kim, Hyun-Jin;Park, Il-gun
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • A road structure washing vehicle equipped with a 4 HP, 80 LPM ultrafine bubble generator was used to clean a tunnel wall and the surface of the surrounding structure, consisting of concrete and tiles, in a heavy traffic area around an apartment complex in the city. Ultrafine bubbles were generated by supplying air at 2 to 3 LPM and using a specially designed nozzle, whereas fine bubbles made by an impeller in a gas-liquid mixing self-priming pump were produced with an average diameter of 165.4 nm and 6.81 × 107 particles mL-1. Using a high pressure washer gun that can perform high-pressure cleaning at 150 bar and 30 LPM, ultrafine bubbles were used to wash dust adsorbed on the surface of the road structures. The experimental analysis was divided into before and after washing. The samples were analyzed by applying ISO 8502-3 to measure surface contamination of dust adsorbed on the surface. Using the transparent tape attached to the surface, the removal rate was calculated by measuring the weight of the dust, and the number of particles was calculated using the gravimetric method and the software, ImageJ. The results of the experiment showed that the number of dust particles adsorbed on the tile wall surface before and after washing were 3,063 ± 218 particles mL-1 and 20 ± 5 particles mL-1, respectively, with weights of 580 ± 82 mg and 13 ± 4 mg. Particles on the surface of the concrete structure before and after washing were 8,105 ± 1,738 particles mL-1 and 39 ± 6 particles mL-1, respectively, with weights of 1,448 ± 190 mg and 118 ± 32 mg.

Study on the simulation of a spark ignition engine using BOOST (상용 소프트웨어를 이용한 스파크 점화 기관의 시뮬레이션에 관한 연구)

  • Jeong, Chang-Sik;Woo, Seok-Keun;Ryu, Soon-Pil;Yoon, Keon-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.733-742
    • /
    • 2016
  • In recent years, gas engines fueled with LNG or synthetic gas have been attracting considerable attention for marine use owing to their potential to facilitate better fuel economy and to reduce emissions. It has been confirmed that gas engines using the Otto cycle, which involves premixed combustion, can satisfy Tier III regulations without the EGR or SCR system. The objective of this study is to acquire simulation technologies for predicting gas engine performances in industrial fields. Using the commercial software BOOST, the simulation is conducted on a gasoline engine rather than a marine engine due to the gasoline engine's easier accessibility. This study consists of two stages. In the first stage published previously, the optimal modeling techniques for representing the behavior of the gas in the intake and exhaust systems were determined. In the current study, we formulated a method to evaluate the combustion and heat transfer processes in the cylinder and to ultimately determine the major performance parameters, given that the analytical model derived from the previous stage has been applied. Through this study, we were able to determine a combustion and heat transfer model and a valve discharge coefficient that are less reliant on empirical data: we were also able to formulate a methodology through which relevant constants are decided. We confirmed that the values of transient cylinder pressure variation, indicated mean effective pressure, and air supply can be successfully predicted using our modeling techniques.

Evaluation of Operational Options of Wastewater Treatment Using EQPS Models (EQPS 모델을 이용한 하수처리장 운전 평가)

  • Yoo, Hosik;Ahn, Seyoung
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.401-408
    • /
    • 2018
  • EQPS (Effluent Quality Prediction System, Dynamita, France) was applied to analyze the appropriateness of the design of a bioreactor in A sewage treatment plant. A sewage treatment plant was designed by setting the design concentration of the secondary clarifier effluent to total nitrogen and total phosphorus, 10 mg/L and 1.8 mg/L, respectively, in order to comply with the target water quality at the level of the hydrophilic water. The retention time of the 4-stage BNR reactor was 9.6 hours, which was 0.5 for the pre-anoxic tank, 1.0 for the anaerobic tank, 2.9 for the anoxic tank, and 5.2 hours for the aerobic tank. As a result of the modeling of the winter season, the retention time of the anaerobic tank was increased by 0.2 hours in order to satisfy the target water quality of the hydrophilic water level. The default coefficients of the one step nitrification denitrification model proposed by the software manufacturer were used to exclude distortion of the modeling results. Since the process modeling generally presents optimal conditions, the retention time of the 4-stage BNR should be increased to 9.8 hours considering the bioreactor margin. The accurate use of process modeling in the design stage of the sewage treatment plant is a way to ensure the stability of the treatment performance and efficiency after construction of the sewage treatment plant.

Development of NORSOK T-100-based telecom management system for off-shore installation (NORSOK T-100 기반의 해양플랜트용 TMS 응용 소프트웨어 개발)

  • Mun, Seong-Mi;Jang, Won-Seok;Park, Su-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.210-216
    • /
    • 2016
  • Malfunctioning of telecom systems can have serious implications on the safe navigation and operation of vessels and off-shore plants. Most safety-related accidents incur significant monetary damages and pollution due to complicated arrangements of the working environments and facilities. Therefore, an automated monitoring system that can collect data from configured telecom equipment connected to a network based on IP is required to ensure safe navigation and operation of such crucial institutions. This paper reports a list of such system requirements, system functions, and user-centered requirements based on the NORSOK T-100 (a standard of telecom management system). These findings were made through research with the newly designed and developed telecom management system (TMS). The TMS was tested by a testbed configured with CCTV, PA/GA, and other network equipment.

A novel energy-efficient bridgeless boost AC to DC converter (효율을 고려한 새로운 AC/DC 컨버터)

  • Yoon, Kyoung-Kuk;Kim, Seong-Hwan;Kim, Deok-Ki
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.223-227
    • /
    • 2016
  • Power supplies make the load compatible with its power source. DC power supplies are extensively used with most electrical and electronic appliances such as computers, television, and audio sets. The presence of non-linear loads results in a low power factor and higher harmonics in the power system. Several techniques for power-factor correction and harmonic reduction have been reported in the literature. This paper proposes a bridgeless boost converter that improves the power factor and reduces the harmonic content in input line currents as compared to full-bridge rectifiers. This bridgeless boost converter eliminates the need of a line-voltage bridge rectifier in conventional boost converter and thereby reduces conduction losses. The effectiveness of the proposed scheme is verified by computer simulations by using the PSIM software.

Transient analysis of marine propulsion motor and shaft under abnormal conditions (이상상태 발생 시 선박용 추진전동기 및 추진축의 과도상태 해석)

  • Oh, Sae-Gin;Kim, Jong-Su;Kim, Seung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.34-38
    • /
    • 2016
  • Recently, electric propulsion systems are been increasingly used in large cruise ships and merchant vessels. When abnormal electrical conditions occur in the motor of an electric propulsion ship, they can cause serious damage to the motor and propeller shaft. Research on abnormal conditions of propulsion motors used in electric propulsion vessels and electric ships difficult to find. In this study, a mathematical model of the electric propulsion system is proposed to analyze transient phenomena that occur in the case of electric propulsion motor or propeller shaft malfunction. A synchronous motor was used in the MATLAB computer simulation of this study. In the event of electrical malfunction of the electric propulsion motor at rated operation, over current occurs in the condition of 1 phase ground, over torque occurs at 3 and 2 phases ground and over current and torque occur when exciting power fails at rated operation.

Improved DC-DC Bidirectional Converter (개선된 DC-DC 양방향 컨버터)

  • Kim, Seong-Hwan;Hur, Jae-Jung;Jeong, Bum-Dong;Yoon, Kyoung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.76-82
    • /
    • 2017
  • Since the introduction of electronically controlled engines and electric propulsion ships, the need for an uninterruptible power supply for emergency power supply devices that use batteries has gained importance. The bidirectional converter in such emergency power supply devices is a crucial component. This paper proposes, a topology for an improved DC-DC bidirectional converter that is characterized by a high voltage conversion ratio and low voltage stress of switches. To confirm the performance of the converter, a computer simulation was executed with PSIM software. The conversion ratio of the proposed converter was found to be four times higher than the conventional boost converter in step-up mode and one-fourth that of the conventional buck converter in step-down mode, and the voltage stress of the switches was one-fourth of the high-side voltage. Moreover, the proposed converter was confirmed to be able to distribute equal currents between two interleaved modules without using any extra current-sharing control method because of the charge balance of its blocking capacitors.

A harmonic reduction scheme for 12-pulse diode rectifiers by auxiliary voltage supply (보조전원장치에 의한 12-펄스정류기의 고조파 저감)

  • Kim, Sung-Hwan;Kim, Jong-Su;Oh, Sae-Gin;Yoon, Kyoung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.916-922
    • /
    • 2014
  • Diode rectifiers have been widely used for an AC to DC converter. But a big problem is that they include large harmonics components in the input currents. A 12-pulse configuration with phase shifting transformer is useful for reducing them. however, it still includes the ($12{\pm}1$)th (m; integer) harmonics in the input currents. In this paper, we propose a single-phase square wave auxiliary voltage supply which is inserted in the middle DC bus. It reduces harmonics especially the 11th and 13th and the harmonic characteristic becomes almost equivalent to a 24-pulse rectifier. Theoretical analysis of the combined 12-pulse diode rectifier with the auxiliary supply is presented and a control method of the auxiliary supply is proposed. The reduction in the input current harmonics is verified by simulation using software PSIM.

A Study on Models for Technical Security Maturity Level Based on SSE-CMM (SSE-CMM 기반 기술적 보안 성숙도 수준 측정 모델 연구)

  • Kim, Jeom Goo;Noh, Si Choon
    • Convergence Security Journal
    • /
    • v.12 no.4
    • /
    • pp.25-31
    • /
    • 2012
  • The SSE-CMM model is how to verify the level of information protection as a process-centric information security products, systems and services to develop the ability to assess the organization's development. The CMM is a model for software developers the ability to assess the development of the entire organization, improving the model's maturity level measuring. However, this method of security engineering process improvement and the ability to asses s the individual rather than organizational level to evaluate the ability of the processes are stopped. In this research project based on their existing research information from the technical point of view is to define the maturity level of protection. How to diagnose an information security vulnerabilities, technical security system, verification, and implementation of technical security shall consist of diagnostic status. The proposed methodology, the scope of the work place and the current state of information systems at the level of vulnerability, status, information protection are implemented to assess the level of satisfaction and function. It is possible that measures to improve information security evaluation based on established reference model as a basis for improving information security by utilizing leverage.

Comparative study of application method of OSMU(One-source Multi-use) in digital contents creation (디지털 영상콘텐츠의 원소스 멀티유스(One-Source Multi-Use) 제작방식 비교 연구)

  • Choi, Jeung-Il
    • Journal of Digital Contents Society
    • /
    • v.9 no.4
    • /
    • pp.551-560
    • /
    • 2008
  • The basic strategy of OSMU(One-source Multi-use) in digital image is a marketing that applying one source to other genres for leverage based on that cross-referencing in different genre enabled that one material(one-source) has synergy effect when reproduced to various products(multi-use) as cultural sources are available through on-line and digital format. Recently, according to the characteristics of culture industry with Window Effect, many culture contents such as movies, games, animations and characters are carefully planned at its design stage to get the maximum effect. Especially, the fact that one leading-trend source makes it easier to produce additional products with the least cost is observed and it enables organized management which resulted in low marketing and PR cost. This paper confirmed that OSMU strategy in Korea mainly get started from online to offline comparing to Japan and USA.

  • PDF