• Title/Summary/Keyword: 소음.진동 모니터링

Search Result 88, Processing Time 0.027 seconds

Noise Test and Evaluation of a 750 kW Wind Turbine Generator (750 kW 풍력발전기의 소음 실증)

  • Kim, Seock-Hyun;Kim, Tae-Hyung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.124-131
    • /
    • 2006
  • This study introduces an environmental noise evaluation procedure for wind turbines(W/T) and the evaluation result of a 750 kW wind turbine(W/T) system. Test and evaluation are performed according to the international standard IEC 61400-11 on J48 W/T which is under operation in Daekwanryung W/T test site. With the meteorological data and W/T operational data, noise data are monitored and analysed. An integrated monitoring system is constructed in the test site and is utilized for the evaluation. From the measured noise data, acoustic power level, directivity and tonality of the W/T are estimated under the wind speeds required fly the International standard. The purpose of the study is to establish an W/T noise evaluating system satisfying the international standard and to obtain noise data for home made 750 kW W/T.

The Development of Seismic Monitoring for a Base-Isolated Building System (지진격리 구조물의 지진모니터링 시스템 개발)

  • 김성훈;조대승;박해동;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.247-251
    • /
    • 2001
  • Nowadays, base isolation systems such as lead-rubber bearing, elastomer bearing and sliding bearing have been installed to the various structures to prevent the disaster from seismic. The performance of base isolation system have been well proved by model-scale experiments and numerical analysis. However. the seismic response data measured at real large base-isolated structures is still insufficient. This paper presents a seismic monitoring system, acquiring real-time acceleration signals up to 32 channels, displaying time history and spectrum of the signals, storing the acquired data at a PC hard disk, and replaying the saved data. Moreover, the system can be operated without any limitation for monitoring period by automatic management of stored data file. The developed system has been installed at a real base-isolated building using lead-rubber bearings and we expect its seismic response data with ground motion signal can be well licquired in case of earthquake occurrence.

  • PDF

Vibration Characteristics of the Tower Structures of Wind Turbine Generators (풍력발전기 타워 구조의 진동 특성)

  • Kim, Seock-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.49-59
    • /
    • 2009
  • Vibrations of the tower structures of 750kW and 6kW wind turbines(WT) are investigated by measurement and analysis. Acceleration responses of the WT towers under various operation condition are monitored in real time by the remote monitoring system using LabVIEW. Using the monitoring system, resonance condition of the tower structures is diagnosed with the wind speed data within the operating speed range. To predict the tower resonance frequency, 750 kW tower is modeled as an equivalent beam with a lumped mass and Rayleigh energy method is applied. For 6 kW WT, Rayleigh-Ritz analysis is carried out on the tower-cable coupled system. Calculated tower bending frequency is in good agreement with the measured value. Using the analysis model, parametric study is available in order to prevent the severe resonance.

  • PDF

The Study on The Evaluation of The Ground Vibration of Cast in Place Concrete Pile Method Effect to Precision Equipment (현장타설 말뚝 공법의 지반진동이 정밀장비에 미치는 영향성 평가)

  • Hong, Byung-Kuk;Kim, Young-Chan;Jang, Kang-Seok;Yoon, Je-Won;Sim, Sang-Deok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.97-102
    • /
    • 2011
  • The size of TV and TFT-LCD are bigger and bigger for the next generation exposure equipment install that existing fab are getting a lot of additions. When the new fab build an extension that the shortening of the construction and non-vibration are use cast in place concrete pile method. In this study when lay the foundation of existing fab adjoin use vibration monitoring system are rotator type all casing method among cast in place concrete pile method. The evaluation of ground vibration of rotator type all casing method effect to precision equipment and vibration area of influence.

  • PDF

Vibration Characteristics of the Tower Structure of a 750kW Wind Turbine Generator (750kW 풍력발전기 타워 구조의 진동 특성)

  • Kim, Seock-Hyun;Nam, Y.S.;Eun, Sung-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.429-434
    • /
    • 2004
  • Vibration response of the tower structure of a 750kW wind turbine generator is investigated by measurement and analysis. Acceleration response of the tower under various operation condition is monitored in real time by vibration monitoring system using LabVIEW. Resonance state of the tower structure is diagnosed in the operating speed range. To predict the tower resonance frequency, tower is modeled as an equivalent beam with a lumped mass and Rayleigh energy method is applied. Calculated tower bending frequency is in good agreement with the measured value and the result shows that the simplified model can be used in the design stage of the wind turbine tower.

  • PDF

Health Monitoring Method for Monopile Support Structure of Offshore Wind Turbine Using Committee of Neural Networks (군집 신경망기법을 이용한 해상풍력발전기 지지구조물의 건전성 모니터링 기법)

  • Lee, Jong Won;Kim, Sang Ryul;Kim, Bong Ki;Lee, Jun Shin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.4
    • /
    • pp.347-355
    • /
    • 2013
  • A damage estimation method for monopile support structure of offshore wind turbine using modal properties and committee of neural networks is presented for effective structural health monitoring. An analytical model for a monopile support structure is established, and the natural frequencies, mode shapes, and mode shape slopes for the support structure are calculated considering soil condition and added mass. The input to the neural networks consists of the modal properties and the output is composed of the stiffness indices of the support structure. Multiple neural networks are constructed and each individual network is trained independently with different initial synaptic weights. Then, the estimated stiffness indices from different neural networks are averaged. Ten damage cases are estimated using the proposed method, and the identified damage locations and severities agree reasonably well with the exact values. The accuracy of the estimation can be improved by applying the committee of neural networks which is a statistical approach averaging the damage indices in the functional space.

Fiber Optic Smart Monitoring of Railway Structures (광섬유센서를 이용한 철도구조물의 모니터링)

  • Kim, Ki-Soo;Cho, Sung-Gyu;Kim, Myeong-Se;Kim, Hak-Yeon;Seo, Ki-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.754-760
    • /
    • 2008
  • For monitoring of railway structures, optical fiber sensors are very convenient. The fiber sensors are very small and do not disturb the structural properties. They also have several merits such as electro-magnetic immunity, long signal transmission, good accuracy and multiplicity of one sensor line. Strain measurement technologies with fiber optic sensors have been investigated as a part of smart structure. In this paper, we investigated the possibilities of fiber optic sensor application to the monitoring of railway structures. We expect that the fiber optic sensors have much less noises than electrical strain gauges because of electro-magnetic immunity while railways operate electric power of 22000 volts. Fiber optic sensors showed good durability and long term stability for continuous monitoring of the railway structures as well as good response to the structural behaviors during construction.

  • PDF

The development of MR damper control modules for a vibration and noise decrease in Washing machine system (세탁기 진동소음의 저감을 위한 MR 댐퍼 컨트롤 모듈 개발)

  • Son, Kyung-Min;Kim, Min;Kim, Gwan-Hyung;Byun, Gi-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.185-187
    • /
    • 2012
  • In this paper, the MR fluid damper to the application of the paramagnetic (paramagnetic) particles dispersed in the MR fluid inside the magnet current caused by the MR damper using the principles of the internal fluid delivery yield stress variation is characterized in Silky. In other words, the current strength of the MR fluid damper according to the internal friction coefficient varies phenomenon is to use. The MR fluid damper to control the MCU that you want to use Microchip's dsPIC chips, and current control in order to improve performance by using the PWM and UART communication to an external monitor to monitor the entire system was designed. In this study using MR fluid dampers and dsPIC chip dehydration process happens when a washing machine vibration and noise, vibration and noise reduction sikidorok washing machine protection systems are proposed.

  • PDF

Development of the Noncontact Vibrometer for the Monitering System of Infrastructures (시설물 모니터링을 위한 비접촉식 진동측정시스템의 개발)

  • Jeong, Yo-Chan;Kwark, Jong-Won;Choi, Eun-Seok;Chin, Won-Jong;Lee, Jung-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.563-566
    • /
    • 2005
  • This study deals with the development of noncontact vibration measuring system for monitoring the safety of structures as bridges, buildings, stadiums, tall chimneys, and dams where vibration measurements are very difficult because of various restrictions. Final object is to develope the system and be commercial by theoretical and experimental studies using IT technology for three years.

  • PDF

Web-based Remote Monitoring System for Machine Tools (웹 기반의 공작 기계 원격 모니터링 시스템)

  • Ryu, C.S.;Noh, K.J.;Hong, D.S.;Jung, S.H.
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.11a
    • /
    • pp.77-80
    • /
    • 2003
  • 본 논문은 웹 기반의 원격 보수유지 시스템을 구현하기 위한 첫 단계의 일부로서 원격 모니터링을 위한 웹 기반 기술 구축에 관한 것이다. 원격 작업장에 있는 정밀 기계 장비(CNC)를 대상으로 하여 작업장이 아닌 장소에서도 온도, 진동, 소음, 영상 데이터 등을 모니터하고 또한 장비의 상태를 진단할 수 있는 시스템 구축에 대한 것이다. 원격 사용자는 인터넷을 통해 어디에서나 생산 현장에 있는 로칼 서버에 접속하여 해당 장비를 모니터 및 상태 진단이 가능한 시스템을 구현하였다.

  • PDF