• Title/Summary/Keyword: 소음 정도,

Search Result 573, Processing Time 0.024 seconds

Development of Directional Digital Hearing Aid Performance Testing System (지향성 보청기 성능 검사 장치 개발)

  • Jarng, Soon-Suck;Kwon, You-Jung;Lee, Je-Hyeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.469-474
    • /
    • 2005
  • The most recent trend on digital hearing aid is to increase the ratio of signal to noise by directivity or to develop noise reduction algorithm inside DSP IC chip. This paper designed, fabricated and tested a digital hearing aid directivity testing device in which a micro-mouse-1ike the stepping motor with a speaker rotates around an examinant. Both ears of the examinant were fixed with ITE hearing aids in order to response to receiving sound. The experimental results were compared with a boundary element method program for verification. The diameter of the directivity testing device was 2 [m] and the micro-mouse was precisely controlled by PICBASIC micro processor.

  • PDF

Minimum Thickness of Flat Plate Slab Satisfying Floor Vibration Criteria (수직진동 사용성을 고려한 플랫 플레이트 슬래브의 최소두께 제안)

  • Lee, Min-Jung;Kim, Dong-Hyun;Han, Sang-Whan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.574-581
    • /
    • 2006
  • Flat plate slab systems are more economical rather than reinforced concrete frame systems because flat plate slab system reduces story height. Furthermore flat plate systems are more popularly needed in construction practice due to flexibility of plan. Korean Concrete Provisions 2003 provide the minimum thickness of the slab that satisfies serviceability requirement to the static displacement. However, floor thickness in residence buildings may not satisfy the floor vibration criteria although the thickness satisfies the serviceability requirements in current design provisions. This study estimates the dynamic properties of floor vibration for existing flat plate slabs, and proposes the slab thickness satisfying the floor vibration criteria. The dynamic response analysis using finite element method and reliability analysis are carried out for this Purpose.

Design and Performance Test of Rubber Engine Mount for Isolation Large Structures (방진고무를 이용한 대용량 엔진마운트의 제작 및 성능시험)

  • 유춘화;김충식;박상규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.93-97
    • /
    • 1993
  • 방진고무는 진동을 방지하여 다른 구조물의 진동전달 차단은 물론, 장비의 수명연장 및 효율을 증가시키기 위한 목적으로 사용되는데 이러한 방진고무 의 동적특성을 일반화하는 것은 어렵기 때문에 방진고무 시편의 동특성 해 석시험 결과치를 기준으로 원하는 성능에 부합하도록 방진고무의 재질을 선 정하고 사양에 의한 엔진마운트를 설계 제작하여야 한다. 이번에 제작한 UEM 엔진마운트는 해상용, 육상용 설비에 적용 가능하며, 특히 해상용에 적 용하고 외부 환경에 의한 부식으로부터 방진고무 및 기자재를 보호하기 위 하여 하우징을 특수재질로 제작하였고, 수직.수평력을 고려하여 큰 하중에 견딜 수 있도록 원추형 형상설계와 강성을 보강하였다. 특히, 원추형 형상으 로 제작하여 하중을 일정하게 분산시키고, 사용 가능한 선형영역을 확대 시 켰으며, Buffer(Steel Bar)를 이용하여 높은 파고 등에 의한 외부 충격량에 따른 큰 변위의 발생으로부터 설비를 보호할 수 있다. 본 논문에서는 물리적 특성이 같은 방진고무를 사용하고, 적층 수만 다르도록 두가지 모델 UEM-155와 UEM-255를 설계 제작하여 수직.수평방향의 정적시험, 동적시 험, 현장 장착시험 등을 수행함으로써 기업에서 요구한 사양에 적합한가를 고찰하였다.

  • PDF

A Study on the Characteristics of Elastomers for Vibration Isolation of Sports Utility Vehicle (스포츠 레저용 차량의 진동절연을 위한 고무제품의 특성에 관한 연구)

  • 사종성;김찬묵
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.671-675
    • /
    • 2001
  • Elastomers, which are engine mounts and body mounting rubbers, are traditionally designed for NVH use in vehicles, and they are designed to isolate specific unwanted frequencies. According to the measurement of the characteristics of engine mounts and body mounting rubbers, dynamic stiffness changes with respect to the driving miles accumulated in engine mounts and initial load in body mounting. This study looks at the variability in same engine mount properties, and the desired dynamic stiffness may increased with driving miles accumulated. And the dynamic stiffness of body mounting rubber changes very stiff above 150Hz.

  • PDF

Control of Acoustic Response of A/C Rectangular Plate Using Piezo Electric Material (압전 소자를 이용한 항공기용 사각박판에 대한 음향 반응제어)

  • Jung, Do-Hee;Park, Seen-Ok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.633-636
    • /
    • 2004
  • Acoustic response control of a corner-pinned plate using piezoelectric wafers was studied, both theoretically and experimentally. Three different sizes of aluminum alloy plates were used and available ball joints were employed to hold the plate at the four comers. The plate with the largest aspect ratio showed the largest and most clear responses to the acoustic excitation in the range of frequencies $(0\sim200Hz)$, and sound pressure levels $(80\sim100dB)$ as predicted. The reduction of the acoustic response of the plate by piezoelectric actuator was very significant, more than expected, but abatement of the sound transmission through the plate was only slightly altered by the piezoelectric actuator. This work is an original work extending earlier work with doors excited by acoustic fields. The important difference is the used of ball joints to simulate the joints.

  • PDF

Research for performance improvement of impact hammer drill (충격 헤머 드릴의 성능향상을 위한 연구)

  • Park, Cheol-Woo;Kim, Jea-Hwan;Han, Sang-Yong;Guan, Nam-Jin;Kang, Chun-Gu;Jung, Young-Chae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.333-336
    • /
    • 2004
  • This paper presents performance of the impact hammer drill with coefficient of restitution, lubrication and friction, pressure leakage, damper efficiency and the general quality test. The novel measurement systems are introduced in order to get the reasonable data. The mechanism of strikers with inner pressure is revealed in the general quality test. Due to these factors we are able to make the computational analysis correctly.

  • PDF

The Design of Wireless Underwater Telephone -Analysis of Underwater Background Noise for Wireless Underwater Telephone Design - (수중 무선 전화기의 설계 - 수중무선전화기 설계를 위한 수중소음분석을 중심으로-)

  • 박문갑;윤갑동;김석제;윤종락
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.4
    • /
    • pp.302-307
    • /
    • 2001
  • The underwater background noise measured in Geoje and Tongyoung diving fishing ground from May to December, 2000 and analyzed to get optimum carrier frequency and transmitter power level for underwater wireless telephone design. The results obtained are summarized as follows: 1. At the Geoje and Tongyoung diving fishing ground, the lowest ambient noise band was 25~30kHz with 57dB and 52dB re 1$\mu$Pa, respectively. 2. At the Geoje and Tongyoung diving fishing ground, the lowest noise band during fishing activity was 67dB and 62dB re 1$\mu$Pa, respectively. 3. At the Geoje diving fishing ground, the noise of water jetter which is a digging machine for subbottom shells was 102dB re 1$\mu$Pa. 4. Considering the design parameters of underwater wireless telephone, it is found that the optimum carrier frequency band is around 30kHz and the transmitter source level should be at least 131dB re 1$\mu$Pa for 500m range telephone.

  • PDF

THE STUDY ON THE NOISE IN THE VESSEL -Effect of the Noise Control by the Noise Arresting Rooms- (선박소음에 관한 연구 -방음실에 의한 소음제어효과실험-)

  • PARK Jung-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.3
    • /
    • pp.215-221
    • /
    • 1976
  • In this study, noise arresting effect of the noise control room from the transmission of surrounding noise was tested when the packing noise control rooms were set up in the test room in which the prerecorded noise from an engine room was reradiated at the same level as the original pressure. The inner space of control room A is $3.389m^3(1.19\times1.19\times2.14m)$ having walls furnished with plywood board 9mm in thickness and noise control room door$(60\times45cm) $ and illumination lamp are placed. In case of the control room B, noise absorption board(10mm fiber board which holds the corntype concavity with diameter of 5mm, depth 5mm, space 15mm) is adhered to the internal ceiling and styrol foam boards(20mm) to the walls. The other struction is same as the control room A. Type C is the same as B except wool board(Glass Fiber, 33mm) on the walls. Type D is same as type A except that the thickness of wall is 12mm and wood pyramid type cone$(5\times5\times13cm)$ is adhered to the ceiling ana walls(Fig. 1). When the recorded noise and vibrated noise were controlled in various levels. The noise pressure which passed through the control rooms was measured by sound level meter(Bruel & Kjar 2205, measuring range 37-140dB). In order to calculate the absorption rate in the control rooms the noise pressure was measured at different distances when the recorded noise pressure was radiated. The followings are the results obtained from the experiment. 1. When the noise pressure of the test room was 60dB, transmission rate of type A was $69.7\%$ and increased $3.3\%$ per 10dB. At the same condition, the rate was $53.9\%$ and increased $4.5\%$ per 10dB in type D. Type D was the most effective in noise arresting of the four and the effect was D,C,B and A in order(Fig.2). 2. When the oscillator sound and vessels noise were radiated in 1,000Hz, at one meter distance to the type A and D, the oscillator sound pressure were 77dB and 73dB, while the vessels noise pressure were 73.3dB and 66.2dB respectivley(Fig.3). 3. Refering to the influence of the frequency to the lower oscillator sound(1,000Hz) pressure, both type C and D were almost same at 140cm but type C was 0.3dB lower than type D at 20cm distance(Fig.4).

  • PDF

Hearing Loss in the Workers Exposed to Organic Solvents and Noise (유기용제와 소음에 폭로된 근로자들의 청력 손실)

  • 김영기;이용환
    • Journal of Life Science
    • /
    • v.9 no.2
    • /
    • pp.136-145
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of organic slovents and noise on hearing loss. We selected organic solvents exposed group of 32 cases, noise exposed group of 31 cases, both noise and solvent exposed group of 31 cases, and control group of 53 cases and studied the relation between exposure level of noise and organic solvents and degree of hearing loss. The results were as follows. The subjects under investigation were exposed to noise and organic solvents under threshold limit values and the amount of urinary hippuric acid excretion were also under biological exposure indices. In case of noise, both noise and organic solvents exposed group and noise exposed group were more exposed than organic solvents exposed group(p<0.05). When urinary hippuric acid excretion were concerned, both noise iud organic solvents exposed group and organic solvents exposed group showed higher values than noise exposed group(p<0.05). In comparison of mean auditory threshold values by frequency, on the air conduction test, both noise and organic solvents exposed group showed significantly higher hearing loss than noise exposed group in 500Hz of right ear, 500 and 2000Hz of left ear(p<0.05). Forty-three cases among 147 subjects were regarded as hearing loss group and average age(42.6years) of hearing loss group was higher than normal groups average age of 38.0 years. Urinary hippuric acid excretions of hearing loss group were significantly higher than normal group(p<0.05). Thirty-eight percent(12cases) of noise exposed group, 40.6 $\%$(13cases) of organic solvents exposed group, 51.6 $\%$(16cases) of both noise and organic solvents exposed group, and 3.8 $\%$(2cases) of unexposed group were regarded as hearing losers. Exposed groups showed higher incidence of hearing loss than unexposed group but there were no significant differences among the exposed groups. The variables showing significant correlation with hearing loss were age and the amount of hippuric acid in urinary excretion. When age were adjusted for the purpose of seeing the effects of hearing losses due to organic solvent, urinary excretion of hippuric acids was the only variable with significant correlation with hearing loss (p<0.05). When odds ratio to hearing loss between control and exposed groups was considered, noise exposed group showed 6.1 times (95 $\%$ CI: 3.3-8.7), organic solvents exposed group showed 7.4 times (95 $\%$ CI: 3.5-14.6) and both noise and organic solvents exposed group showed 17.2 times(95% CI: 5.6-31.8) higher values than unexposed group(p<0.01). Above results suggest that health screening test of hearing loss is also needed in organic solvents exposed workers.

  • PDF

Sound Insulation Strategy for the Tunnel Noise in a High Speed Train (고속철도차량의 터널 소음을 위한 차음 전략)

  • Kim, Seock-Hyun;Lee, Ho-Jin;Kim, Jung-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.315-322
    • /
    • 2012
  • In a tunnel, interior noise of a high speed train increases by 5dB~7dB. The reason is that the sound intensity of the acoustic field in the tunnel significantly increases by the reflected waves occurred in the closed space. Especially, the incident acoustic power largely increases on the outside of the compartment side panel and large transmission of noise is available through the side panel and the glass window. In this paper, the sound insulation strategy in the tunnel is proposed for the next generation high speed train under development. Specimens of the aluminum extruded panels, layered panels and double glazed window are manufactured and intensity transmission loss is measured according to ASTM E2249-02. Based on the measured data, problems in the sound insulation performance are diagnosed and the sound insulation strategy is reviewed on each panel and layered structures.