• 제목/요약/키워드: 소음의 감쇠

검색결과 537건 처리시간 0.025초

실시간 하이브리드 실험법을 이용한 동조액체기둥감쇠기가 설치된 구조물의 지진응답 제어성능 평가 (Performance Evaluation of Controlling Seismic Responses of a Building Structure with a Tuned Liquid Column Damper using the Real-Time Hybrid Testing Method)

  • 정희산;이성경;박은천;민경원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.669-673
    • /
    • 2007
  • In this study, real-time hybrid test using a shaking table for the control performance evaluation of a U-shaped TLCD controlling the response of earthquake-excited building structure is experimentally implemented. In the test, the building structure is used as a numerical part, on which a U-shaped TLCD adopted as an experimental part was installed to reduceits response. At first, the force that is acting between a TLCD and building structure is measured from the load cell attached on shaking table and is fed-back to the computer to control the motion of shaking table. Then, the shaking table is so driven that the error between the interface acceleration computed from the numerical building structure with the excitations of earthquake and the fed-back interface force and that measured from the shaking table. The control efficiency of the TLCD used in this paper is experimentally confirmed by implementing this process of shaking table experiment on real-time.

  • PDF

능동동조질량감쇠기와 수정 PPF 제어기를 이용한 구조물의 능동진동제어 (Active Vibration Control of Structure Using Active Tuned Mass Damper and Modified PPF Controller)

  • 김기영;곽문규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.550-555
    • /
    • 2007
  • This paper is concerned with the active vibration control of building structure by means of the active tuned mass damper and the modified positive position feedback controller. To this end, one-degree-of-freedom spring-mass-damper system equipped with ATMD is considered. The stability condition for the addressed system when applying the proposed PPF controller is derived by Routh-Hurwitz stability criterion. The stability condition shows that the modified PPF controller is absolutely stable if the controller gain is positive, so that the modified PPF controller can be used without difficulty. Theoretical study shows that the modified PPF controller can effectively suppress vibrations as the original PPF controller does in smart structure applications. To investigate the validity of the modified PPF controller, a simple experimental structure with an ATMD system driven by DC motor was built. The modified PPF control algorithm was implemented on Atmel 128 microcontroller. The experimental result shows that the modified PPF controller can also suppress vibrations for the real structure.

  • PDF

보단부 회전형감쇠기를 이용한 대형구조물의 진동제어 (Vibration Control of Large Scale Structure with Beam-End Rotation Type Friction Damper)

  • 이상현;우성식;정란;조승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.452-458
    • /
    • 2007
  • The vertical extension of a building in general remodeling process increases both gravity and seismic loads by simply adding masses to the building. In this study, a vertical extension structural module (VESM) is proposed for enhancing seismic performance of the existing buildings by utilizing the story-increased parts. The proposed VESM is composed of steel column, steel beam, and beam-end rotational damper. The steel columns are connected to the shear walls and transfer the wall rotation in out-of plane to the steel beam, and then the beam-end rotational damper dissipates the earthquake-induced energy. Numerical analysis result from a cantilever beam of which end-rotation is restricted by rotational damper indicates that the displacement, base shear, and base overturning moment of the existing structures showing cantilever behavior can be significantly reduced by using the proposed method. Also, it is observed that friction-type rotational damper is effective than viscous one.

  • PDF

마찰형 감쇠를 갖는 구조물의 응답 스펙트럼 (Response Spectra of Structure Installed Frictional Damping System)

  • 박지훈;윤경조;민경원;이상현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.893-897
    • /
    • 2006
  • Structures with additional frictional damping system have strong nonlinearity that the dynamic behavior is highly affected. by the relative magnitude between frictional force and excitation load. In this study, normalized response spectra of the structures with non-dimensional friction force are obtained through nonlinear time history analyses of the mass-normalized single degree of freedom systems using 20 ground motion data recorded on rock site. The variation of the control performance of frictional damping system is investigated in terms of the dynamic load and the structural natural period, of which effects were not considered in the previous studies. Least square curve fitting equations are presented for describing those normalized response spectrum and optimal non-dimensional friction forces are obtained for controlling the peak displacement and absolute acceleration of the structure based on the derivative of the curve fitted design spectrum.

  • PDF

격자구조로 배열된 실린더에 의한 음파감쇠 (Sound Attenuation by Cylinders Arranged in a Lattice)

  • 김현실;김상렬;김재승;김봉기;이성현
    • 한국소음진동공학회논문집
    • /
    • 제21권11호
    • /
    • pp.1013-1019
    • /
    • 2011
  • Sound attenuation of periodically arranged cylindrical rods is studied numerically and experimentally. Cross section of the cylinder is circular and arrays are in a square lattice. Cylinders are made of steel, and consist of five groups with different diameters from 27.2 mm to 48 mm. Each group has 5 rows, while number of cylinders in a row varies from 17 to 31. The area filling fraction is about 60~61 %, which leads to the stop bandgap(2.9 kHz ~ 8.4 kHz). Sound attenuation is computed using two-dimensional BEM, and measurement is done by using a speaker and microphones in a semi-anechoic room. Comparison of the results by BEM and experiment shows that attenuation spectra are qualitatively in agreement, although experiment gives higher attenuations than BEM. After results by BEM are scaled up in accordance with cylinder diameter, it is observed that attenuation curves are in good agreement, which confirms that analysis by BEM is done correctly. It is also found that the measured bandgaps are shifted toward lower frequency by 0.5 kHz ~ 1.2 kHz, when compared to the predictions obtained from infinitely repeated two-dimensional cylinder arrays.

유체봉입 마운트의 유로 조절에 따른 진동감쇠 성능향상 (Dynamic Analysis of Switchable Hydraulic Engine Mount with an Inertia Track and a Decoupler)

  • 안영공
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.80-86
    • /
    • 2017
  • This paper describes switching method of the cross-sectional area of the fluid passage way to improve the performance of a hydraulic engine mount with an inertia track and a decoupler. The mount has nonlinear dynamic characteristics depending on the vibrational frequency and amplitude. For the convenience of analysis, two linear motion equations were derived on the basis of the mechanical model according to the low-and high-frequencies. The properties of the transmissibility and dynamic stiffness derived from the equations were investigated according to switching the cross-sectional area of the inertia track and decoupler. Switching method of the cross-sectional area can be derived from the transmissibility plot. In comparison between transmissibility of passive and switchable mounts with an inertia track and a decoupler, the performance of the switchable mount is improved greatly than the passive mount. The resonant peak is remarkably reduced in the high frequency region.

전단벽식 구조의 휨거동을 이용한 마찰감쇠기의 제어성능 (Control Performance of Friction Dampers Using Flexural Behavior of RC Shear Wall System)

  • 정희산;문병욱;박지훈;이성경;민경원;변지석
    • 한국소음진동공학회논문집
    • /
    • 제18권8호
    • /
    • pp.856-863
    • /
    • 2008
  • High-rise apartments of shear wall system are governed by flexural behavior like a cantilever beam. Installation of the damper-brace system in a structure governed by flexural behavior is not suitable. Because of relatively high lateral stiffness of the shear wall, a load is not concentrate on the brace and the brace cannot perform a role as a damping device. In this paper, a friction damper applying flexibility of shear wall is proposed in order to reduce the deformation of a structure. To evaluate performance of the proposed friction damper, nonlinear time history analysis is executed by SeismoStruct analysis program and MVLEM(multi vertical linear element model) be used for simulating flexural behavior of the shear wall. It is found that control performance of the proposed friction damper is superior to one of a coupled wall with rigid beam. In conclusion, this study verified that the optimal control performance of the proposed friction damper is equal to 45 % of the maximum shear force inducing in middle-floor beam with rigid beam.

3층 샌드위치보의 진동해석 (Vibration Analysis of Three Layer Sandwich Beam)

  • 박철휴;김원철;양보석
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.157-170
    • /
    • 1998
  • 본 연구에서는 진동수에 종속된 GHM (Golla-Hughes-McTavish) 내부보조좌표를 사용하여, 3층 샌드위치보의 유한요소모델을 정식화하는 새로운 기법을 제안하였다. 내부보조좌표를 3층 샌드위치보에 사용하면, 비감쇠질량과 강성행렬의 운동방정식은 정성감쇠행렬이 포함되므로써 행렬의 요소들이 복잡하게 확장되어 진다. 따라서 이 방법은 실제의 많은 응용에 있어서 바람직하지 못한 유한요소모델의 행렬요소들의 증가에 따른 많은 단점을 갖게 된다. 따라서, 본 논문에서는 행렬요소들의 증가에 따른 여러 단점들을 제거하기 위하여, 행렬요소 감소방법을 GHM방정식과 합성된 운동방정식을 유도하는 새로운 방법을 제안한다.

  • PDF

보단부 회전형감쇠기를 이용한 건축구조물의 내진성능보강 (Seismic Performance Enhancement of Building Structures with Beam-end Rotation Type Dampers)

  • 우성식;이상현
    • 한국소음진동공학회논문집
    • /
    • 제18권6호
    • /
    • pp.589-597
    • /
    • 2008
  • The vertical extension of a building in general remodeling process increases both gravity and seismic loads by simply adding masses to the building. In this study, a vertical extension structural module(VESM) is proposed for enhancing seismic performance of the existing buildings by utilizing the story-increased parts. The proposed VESM is composed of steel column, steel beam, and beam-end rotational damper. The steel columns are connected to the shear walls and transfer the wall rotation in out-of plane to the steel beam, and then the beam-end rotational damper dissipates the earthquake-induced energy. Numerical analysis result from a cantilever beam of which end-rotation is restricted by rotational damper indicates that the displacement, base shear, and base overturning moment of the existing structures showing cantilever behavior can be significantly reduced by using the proposed method. Also, it is observed that friction-type rotational damper is effective than viscous one.

수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안 (Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-Horizontal Area Ratio)

  • 우성식;이상현;정란;이정우;조승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.653-658
    • /
    • 2008
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the Case01 to 19, the standard deviation($s_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the Case21 to 61, the standard deviation ($s_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

  • PDF