• Title/Summary/Keyword: 소요실

Search Result 185, Processing Time 0.028 seconds

A Study on the Characteristics of Area and Spatial Elements Based on the Building Size of Childcare Center (보육시설 평면사례분석을 통한 시설규모별 소요실 및 면적특성 분석)

  • Park, Jung-A;Choi, Mock-Wha;Kim, Young-Aee
    • Journal of the Korean housing association
    • /
    • v.22 no.1
    • /
    • pp.65-73
    • /
    • 2011
  • The purpose of this study is to find out the characteristics of area and spatial elements according to the building size and provide the guidelines for space planning of the child care center. This study used the content analysis method and analysis was made on the floor plans for 51 cases and the floor plans were converted to Autocad drawings to analyze the area. The results of this study were as follows; 1) Child care centers over 70% were single-attached building types which made it possible for creating outdoor environments for children. However, most small-size centers which had under 50 children did not have the facilities for outdoor activities. 2) In terms of spatial elements, the basic spaces of the small-size center were the classroom, bathroom, kitchen, office and reference room. The medium or large size centers had extra rooms for special activities and service spaces in addition to the basic spaces. 3) Classroom area per child was 2.65 m2 on average. Space composition ratio on average for care, staff, and service was programmed by 57%, 9%, 34% respectively. Small-size center had relatively more care space when compared to the others. In the case of large-size centers, there was a tendency that service space was increased, but care space was decreased.

Program development for playback time estimation (플레이백 시간 예측 프로그램 개발)

  • Chae, Dong-Seok;Yang, Seung-Eun;Lee, Jae-Seung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.492-494
    • /
    • 2012
  • 저궤도 위성은 위성과 지상과의 통신시간이 제한되어 있으므로 제한된 시간에 위성의 대용량메모리(Mass Memory)에 저장된 데이터를 전송받아야 하는데, 이를 위해 저장되는 데이터 량을 정확히 예측할 수 있어야 하고, 저장된 데이터 량에 따라 지상으로 전송하는데 소요되는 시간을 예측할 수 있어야 한다. 본 논문은 위성에 저장되고 있는 Telemetry 종류에 따라 대용량메모리에 저장되는 데이터 량을 예측하고, 저장된 데이터 량에 따라 지상으로 전송하는데 소요되는 시간을 계산하기 위해 개발된 플레이백 시간 예측 프로그램에 대해 서술한 것이다.

Improvement of indoor mushroom kit (소비촉진을 위한 가정재배용 버섯키트개발 연구)

  • Jo, Woo-Sik;Rew, Young-Hyun;Choi, Sung-Kuk;Yoon, Jae-Tak
    • Journal of Mushroom
    • /
    • v.5 no.1
    • /
    • pp.29-33
    • /
    • 2007
  • This study for establishment of cultivation technique was carried out in home, Pleurotus ostreatus, Ganoderma lucidum. The mushroom kit allows you to grow some of the mushrooms used by the finest chefs in the world easily and quickly almost anywhere in your own home or office. Mushroom kits may be placed on a coffee table, counter, or desk. They will produce mushrooms virtually anywhere room temperature is maintained. Now we have the opportunity not only to enjoy watching these exotic mushrooms grow but also to enjoy eating the freshest organic mushrooms possible. To study for the possibility of indoor cultivation of P. ostreatus, and G. lucidum, we invested cultivation status with two kinds of sawdust, cotton waste and rice straw in washroom, kitchen, living room, and bedroom. It took 2~4 days to make primordia formation in a block of P. ostreatus, and G. lucidum was 11 days. Weight of P. ostreatus on cotton waste, rice straw, and willow sawdust were 2,060g, 90g, and 770g, respectively. and weight of G. lucidum on oak sawdust was 172g. Th best result was achieved in washroom, among used washroom, kitchen, living room, and bedroom.

  • PDF

The Influence of Stairway Pressurization Conditions on the Stack Effect in Super-tall Buildings (초고층건물 계단실 단독 급기가압 제연조건이 연돌효과에 미치는 영향)

  • Park, Yong-Hwan;Kim, Beom-Gyu
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.109-115
    • /
    • 2010
  • Maximum pressure difference in central core type 80th super_tall buildings was estimated as 75 Pa during no outside wind due to the winter stack effect. Maximum pressure difference of 225 Pa can be obtained depending on the location of air injection fan during the stairway pressurization at fire. Bottom_only air injection system provided the best results in the sense of required air flow rates and pressure distributions. Top_only air supply system was estimated as the worst for this country. It revealed that the decrease of the temperature in the stairway due to the cold outside air injection reduced the required flow rates of the fan and significantly changed the distribution of pressure differences.

Big Data based Classroom Assignment Algorithm and its Application to the Academics System (데이터에 근거한 강의실 자동 배정 알고리즘 설계와 학사관리 시스템 적용사례)

  • Chin, Sang-Kyu;Kim, Seung-Hwan;Lee, Soon-Kyo;Cheong, Taesu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.348-351
    • /
    • 2016
  • 대학에서는 매학기 개설된 수업에 대해 강의실 배정작업을 진행하고 있으며 대부분의 대학에서는 년4회(1 2학기, 여름, 겨울 계절학기) 수작업으로 반복적인 강의실 배정 작업을 수행하고 있다. 강의실 배정작업은 교수가 선호하는 강의실 또는 교과목특성(실험과목 및 대형 강의)이 반영된 강의실 등 다양한 조건에 의해 강의실을 배정하고 있으며 수작업으로 일일이 강의실을 배정 하는 데에는 상당한 시간이 소요되고 있다. 몇몇 대학에서는 강의실 배정작업을 개선하기 위해 교수 및 강의실의 특성을 고려한 강의실 자동 배정 시스템을 구축을 시도 하였으나, 많은 변수로 인해 여전히 수작업으로 강의실을 배정하고 있다. 이에 본 연구에서는 강의실 자동 배정 시스템을 구축하기 위한 방법으로 최근 3년간 기 배정된 강의실 빅 데이터 자료를 기반으로 작성된 강의실 자동 배정 알고리즘을 제시하고 실적용한 고려대학교 시스템 구축 사례를 살펴보고자 한다.

Safety Evaluation of Concrete Bridges for Passage of Crane Vehicle Exceeding Weight Limit (제한 중량을 초과하는 기중기 차량 통행에 대한 콘크리트 교량의 안전성 평가)

  • Lee, Sung-Jae;Yu, Sang Seon;Park, Younghwan;Paik, Inyeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.92-101
    • /
    • 2020
  • It is necessary to develop a rational method for evaluating the safety of bridges for the passage of inseparable crane vehicles exceeding the limit weight. In this study, the same method applied to the development of the recently introduced reliability-based highway bridge design code - limit state design method is applied to the calibration of the live load factor for the crane vehicle. Structural analysis was performed on the concrete bridge and the required strengths of the previous design code, the current design code and AASHTO LRFD were compared. When comparing the unfactored live load effect, the live load of the crane was greater than that of the current and previous design code. When comparing the required strength by applying the calibrated live load factor, the previous design code demands the largest strength and the current design code and the crane live load effect yields similar value. The results of safety evaluation of the actual bridges on the candidate route for the crane passage secured the same reliability as the target reliability index required by the design code and the strength of the cross section of the actual bridge is calculated greater than the required strength for the passage of the crane, which confirms the safety for the passage of the crane.

야외시험장의 구성 및 평가

  • 정연춘
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.2
    • /
    • pp.69-78
    • /
    • 1991
  • 전자파장해 측정에 사용되는 대표적인 측정시설에는 접지면(ground plane)을 갖춘 야외시험장 (open area test site), 전자파반무향실(semianechoic chamber), TEM(transverse Electromagnetic) cell, 평행판선로(parallel plate line), 헬름홀츠코일(Helmholtz coil), 전자파잔향실(reverberating chamber) 등이 있으며, 이러한 시설은 시험대상기기의 크기, 주파수대역, 적용규격의 규제치, 측정하고자 하는 전자기장의 형태 및 편파면, 그리고 시험신호의 전기적 특성(주파수영역 또는 시간영역) 등을 고려하여 선택되고 구성되 어야 한다. 실제로 시험장소를 건설하는데 막대한 비용이 소요되고, 큰 측정오차를 유발시킬 수 있기 때문에 매우 신중 하게 설계, 구성하여야 한다.

  • PDF

Automation of electrical acoustic experimental apparatus for the directivity measurement of sound (소리의 지향성 측정을 위한 전기음향실험기기의 자동화)

  • Jarng Soon Suck;Ko Jae Ha
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.231-234
    • /
    • 2004
  • 디지털 보청기를 착용한 사람의 지향성 측정 및 시뮬레이션 비교를 위해서 실제 실험 장치(무향실)와 여러 전기음향 계측기기를 이용한 실험을 수행하는 과정에서 많은 소요 시간의 문제점이 발생하였다. 그래서 실험 시간을 단축하기 위해 본 전기음향 실험기기의 자동화 및 고속화를 연구하였다 지향성 실험을 위해 간이형 무향실이 회전하도록 설계하였고, 이에 따른 자동제어를 위한 프로그래밍을 연구하였다.

  • PDF

A Study on the Prediction Model of the Warship Construction Period through Statistical Analysis (통계적 분석기법을 통한 함정 건조기간 예측모델에 관한 연구)

  • Choi, Daewook;Ma, Jungmok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.497-502
    • /
    • 2020
  • For the Navy to acquire the desired vessels in time, it is necessary to plan the schedule accurately for warships. On the other hand, until now, there has been only a subjective prediction of the period of warship construction through a survey by a group of experts. No academic studies have been conducted based on actual data. Therefore, this study presents a model for predicting the construction period of a warship through linear regression based on actual data. Experts first identified the factors that can affect the warship construction period. Actual data of the factors were collected, and regression analysis was performed to estimate the ship construction period. As a result, the key factors selected that influence the construction period of a ship were the number of operational test items, number and type of equipment, and the number and type of R&D equipment. The resulting regression model revealed 96.5% accuracy in terms of internal validity.

Efficient Integrated Real-time Discharge Measurement System Operating Strategy applying Non-face-to-face technology (비대면 기술을 적용한 효율적인 자동유량측정시스템 운영 방안)

  • Oh, Dong Heon;Baek, Jong Seok;Cho, Sang Uk;Cha, Jun Ho;Seo, Hae Yeop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.482-482
    • /
    • 2021
  • 자동유량측정시스템은 하천 유량을 실시간으로 측정하기 위한 수문조사시설로 전국 하천 64개 주요 지점에 설치·운영 중이며 실시간으로 운영되는 시스템의 특성상 내·외부 요인으로 인해 자료의 결측이 발생할 수 있다. 주요 결측 요인으로는 계측장비의 고장 및 오작동, 낙뢰로 인한 전원부문제, 시스템 컨트롤러 단순 오류 등이며, 현재 이로 인해 결측이 발생한 경우 현장 방문을 통한 조치 외에는 복구가 불가한 실정이다. 본 연구에서는 현장 유지관리 개선을 통해 자료 결측 최소화 방안을 마련하고자 최근 5년간(2015년~2019년) 수행된 유지관리 점검내역을 검토하였다. 현장 유지관리는 정기적으로 수행되는 정기점검, 수중점검과 장애 발생 시 수행되는 현장점검으로 구분되며 최근 5년간 수행된 점검(1,735회) 중 정기적인 점검을 제외한 현장점검의 경우 총 764회(46%) 수행된 것으로 나타났으며 현장점검 중 유지관리 방법 및 장비 개선 적용 사례를 통해 최소 1일~3일 소요되던 점검 시간이 즉시 조치가 가능한 것으로 나타났다. 시스템 확대 및 기존 장비의 노후로 현장점검은 지속적으로 증가하고 있으며 최근 사회적 상황을 고려하였을 때 사물인터넷(IoT)을 활용한 시설물 개선 등으로 비대면 점검 수행이 가능해짐에 따라 점검 소요시간을 단축하여 보다 효율적인 시설물 운영, 예산 절감, 자료의 연속성 확보 등이 가능할 것으로 판단된다.

  • PDF