• Title/Summary/Keyword: 소성 영역크기

Search Result 54, Processing Time 0.017 seconds

Catalytic Combustion of Methane over $AMnAl_{11}O_{19}$(A=La, Sr, Ba) and $CeO_2/LaAMnAl_{11}O_{19}$ ($AMnAl_{11}O_{19}$(A=La, Sr, Ba) 및 $CeO_2/LaAMnAl_{11}O_{19}$를 이용한 메탄의 촉매 연소)

  • Kim, Seongmin;Lee, Joon Yeob;Cho, In-Ho;Lee, Dae-Won;Lee, Kwan-Young
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.633-638
    • /
    • 2011
  • Mn substituted La, Sr or Ba-hexaaluminate were prepared by $(NH_4)_2CO_3$ co-precipitate method and calcined at $1,200^{\circ}C$ for 5 h. Catalysts were characterized by X-ray diffraction and $N_2$ physisorption and scanning electron microscope (SEM). Compared to $SrMnAl_{11}O_{19}$ and $BaMnAl_{11}O_{19}$, $LaMnAl_{11}O_{19}$ in which La located at mirror plane showed better crystallinity and high surface area, 13 $m^2/g$. $LaMnAl_{11}O_{19}$ revealed well developed plate-like structure which is characteristic structure of hexaaluminate. The catalytic activity of methane combustion increased in the following order: $LaMnAl_{11}O_{19}$ > $SrMnAl_{11}O_{19}$ > $BaMnAl_{11}O_{19}$ and was dependent on surface area of catalysts. 60 wt% $CeO_2/LaMnAl_{11}O_{19}$ calcined at $700^{\circ}C$ showed enhanced methane activity and methane was oxidized completely at low temperature ($700^{\circ}C$). It was confirmed that addition of ceria seems to be effective for the low and middle temperature combustion of methane. But, after calcination at high temperature of $1,200^{\circ}C$, it lost the promoting effect of ceria due to increase of ceria particle size and it had a limit to applying to the high temperature catalytic combustion.

Effect of Different Energy Frames on the Impact Velocity of Strain Energy Frame Impact Machine (에너지 프레임 종류에 따른 변형에너지 프레임 충격시험장치의 충격속도)

  • PARK, Seung Hun;PARK, Jun Kil;TRAN, Tuan Kiet;KIM, Dong Joo
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.363-375
    • /
    • 2015
  • This research investigated the effects of diameter and material of energy frame on the impact velocity or strain rate of Strain Energy Frame Impact Machine (SEFIM). The impact speed of SEFIM have been clearly affected by changing the diameter and material of the energy frame. The reduced diameter of the energy frame clearly increased the impact velocity owing to the higher strain at the moment of coupler breakage. And, titanium alloy energy frame produced the fastest speed of impact among three materials including steel, aluminum and titanium alloys because titanium alloy has faster wave velocity than steel. But, aluminium energy frame was broken during impact tests. In addition, the tensile stress versus strain response of high performance fiber reinforced cementitious composites at higher and wider strain rates between 10 and 72 /sec was successfully obtained by using four different energy frames.

Analytical and Experimental Study on the Quality Stability of Multi Roll Forming Process (멀티 롤 포밍 공정의 품질 안정성에 대한 해석 및 실험적 연구)

  • Son, Jae-Hwan;Han, Chang-Woo;Ryu, Kyung-Jin;Kang, Hae-Dong;Kim, Chul-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6977-6984
    • /
    • 2015
  • It is faced with the necessity of multi roll forming process of the ball slide rail which is made by adding the separate manufacturing processes, piercing, bending, trimming, to the roll forming process of a continuous plastic deformation, to improve the quality. However, the vibration and noise of the press machine in this process leads to the quality degradation of slide rail manufactured in this process. In this study, the roll was designed considering the optimal strain rates by the roll forming program with finite element method. And to estimate the static stability of the multi process the Von-Mises stress and deformation on the press was calculated with a structural analysis program. Also, to avoid driving systems in the resonance region their natural frequencies in the 1st and 2nd mode were calculated through the modal analysis. To verify its dynamic stability improvement the magnitudes of noise and vibration in the existing and studied system were compared using a microphone and accelerometers. And the widths and surface roughnesses of the rails which had been produced in the existing and studied process were measured. Therefore, it is known that multi roll forming process is stable in the analytical and experimental study.

Failure Pattern of Pineal and Ectopic Pineal Germ Cell Tumor after Gamma Knife Radiosurgery (송과선 및 이소성 송과선 생식세포종의 감마 나이프 수술 후 재발 양상)

  • Cho, Heung-Lae;Sohn, Seung-Chang
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.92-100
    • /
    • 2000
  • Purpose :This study was performed to determine the optimal treatment velum of Patients treating with radiation therapy for intracranial germ cell tumor. Materials and Methods : From 1993 to 1998, 19 patients with intracranial germ cell tumors treated by gamma knife radiosurgery were analyzed. The location of tumor was as follows; 9 cases on pineal region, 1 case on suprasellar region, and 9 cases of multiple lesion. 7 patients were pathologically verified; 5 cases of germ cell tumor and 2 cases of non germinomatous germ cell tumor. Tumor volume was ranged from 2.4 cm$^{3}$ to 74 cm$^{3}$. Irradiation dose was 10 Gy to 20 Gy with 50% isodose curve. Follow up period was 10 months to 54 months. Results : Recurrences were observed in 14 cases among 19 (74%) patients. Complete remission and partial remission were achieved in 2 (11%) and 10 (53%) respectively. No response was observed in 7 (36%). 2 cases were recurred within original tumor bed. 6 cases were recurred beyond but contiguous with tumor bed. Ventricular relapses separated from pretreatment tumor bed were 3. Spinal recurrences were 4. Among 8 recurred cases of which tumor volume is smaller than 20 cm$^{3}$, 2 were recurred within original tumor bed, 4 were recurred beyond but contiguous with tumor bed, and 1 spinal recurrence. Meanwhile, 6 cases of which tumor volume larger than 20 cm3, 1 case was recurred beyond but contiguous with tumorbed, 2 ventricular recurrences separated with original tumor bed, and 3 spinal recurrences. 5 cases which did not show any recurrence sign showed characteristics of single lesion, tumor volume smaller than 20 cm$^{3}$ and normal tumor marker. All of 4 cases of spinal recurrences happened in the case having ventricular invasion or lesion. Among 9 cases having multiple lesion, only 3 cases recurred within original tumor bed or around tumor bed, the other 6 cases recurred separated from pretreatment tumor bed. Conclusion : Gamma knife radiosurgery is not recommended for the treatment of intracranial germ cell tumor. It is because of small treatment volume and inadequate radiation dose that are characteristics of gamma knife radiosurgery. Tumor volume, ventricular invasion or ventricular lesion in multiple lesion are important factors to be considered for the wide field radiation therapy Tumor volume smaller than 20 cm$^{3}$, single lesion, no ventricular lesion or invasion, and normal tumor marker are ideal indications for small involved field radiation therapy. Prophylactic spinal irradiation seems to be necessary when there is ventricular lesion, ventricular invasion, and multiple lesions. When the tumor volume is larger than 20 cm$^{3}$, multiple lesions, abnormal tumor marker, and whole ventricular irradiation or partial brain irradiation would be possible and neoadjuvant chemotherapy would be most beneficial in these group.

  • PDF