• Title/Summary/Keyword: 소산 효과

Search Result 202, Processing Time 0.027 seconds

The study of analysis of mutagen in drinking water (음용수 중 변이원성 물질(MX)에 관한 연구)

  • Yoo, Eun-Ah;Won, Jung-In
    • Analytical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.290-300
    • /
    • 2006
  • Disinfection by-products(DBPs), such as volatile trihalomethanes and the nonvolatile organochlorine acids, created by chlorination have been extensively studied. However MX which contributes 20-50% of the mutagenic activity in drinking water began to people's attention since 1990. Its chemical name is 3-chloro-4-dichloromethyl-5-hydroxy-2(5H)-furanone. According to WHO guidelines its concentration should be controlled, but its value has not been set up. Due to analytical difficulties in measuring this compound at such a low concentrations and lack of information on toxicity to human. Because concentration (ng/L) of MX in drinking water is low traditional testing methods are ineffective. Therefore this study compared LLE and SPE and have chosen SPE to improve preconcentration. MX has been identified in chlorinated drinking water samples in several countries but not in korea Therefore this study analyzed concentration of MX in different water sources and in spring water. This study examined the causes of changing MX content. Chlorine dosage, seasons, water temperature and distance from the source was all discoverd to be relavant. MX was analyzed in various treatment to find optimum disinfection methods. The outcome was that the concentration of MX was minimized when using biological activated carbon-O3 and granular activated carbon.

Comparative study of laminar and turbulent models for three-dimensional simulation of dam-break flow interacting with multiarray block obstacles (다층 블록 장애물과 상호작용하는 3차원 댐붕괴흐름 모의를 위한 층류 및 난류 모델 비교 연구)

  • Chrysanti, Asrini;Song, Yangheon;Son, Sangyoung
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.spc1
    • /
    • pp.1059-1069
    • /
    • 2023
  • Dam-break flow occurs when an elevated dam suddenly collapses, resulting in the catastrophic release of rapid and uncontrolled impounded water. This study compares laminar and turbulent closure models for simulating three-dimensional dam-break flows using OpenFOAM. The Reynolds-Averaged Navier-Stokes (RANS) model, specifically the k-ε model, is employed to capture turbulent dissipation. Two scenarios are evaluated based on a laboratory experiment and a modified multi-layered block obstacle scenario. Both models effectively represent dam-break flows, with the turbulent closure model reducing oscillations. However, excessive dissipation in turbulent models can underestimate water surface profiles. Improving numerical schemes and grid resolution enhances flow recreation, particularly near structures and during turbulence. Model stability is more significantly influenced by numerical schemes and grid refinement than the use of turbulence closure. The k-ε model's reliance on time-averaging processes poses challenges in representing dam-break profiles with pronounced discontinuities and unsteadiness. While simulating turbulence models requires extensive computational efforts, the performance improvement compared to laminar models is marginal. To achieve better representation, more advanced turbulence models like Large Eddy Simulation (LES) and Direct Numerical Simulation (DNS) are recommended, necessitating small spatial and time scales. This research provides insights into the applicability of different modeling approaches for simulating dam-break flows, emphasizing the importance of accurate representation near structures and during turbulence.

Bactericidal Activity of Strongly Acidic Electrolyzed Water on Various Vegetables and Kitchen Apparatus (채소 및 주방기구에 대한 강산성전해수의 살균효과)

  • Kim, Yun-Jung;Choi, Kyoo-Duck;Shin, Il-Shik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.5
    • /
    • pp.776-781
    • /
    • 2010
  • The properties and bactericidal activities of strongly acidic electrolyzed water (SEW) against food-borne pathogenic bacteria, vegetables and kitchen apparatuses were investigated. The available chlorine concentration, pH and oxidation reduction potential (ORP) of SEW were $35{\pm}1.2\;ppm$, $2.3{\pm}0.2$, and $1,140{\pm}20.4\;mV$, respectively. Five strains of food-borne bacteria with initial cell number of 7.00 log CFU/mL were not detected except Bacillus cereus after treatment with SEW for 60 sec. The numbers of Bacillus cereus were reduced to 2.08{\pm}1.00 log CFU/mL at the same condition. In vegetables, SEW treatment after washing strongly in alkalic electrolyzed water (AEW) showed better bactericidal effects than SEW only. The viable cell on stainless steel bowl ($3.86{\pm}2.49\;\log\;CFU/100\;cm^2$) and cup for water ($2.40{\pm}1.80\;\log\;CFU/100\;cm^2$) were not detected by SEW treatment (35 ppm of available chlorine concentration) for 30 sec, but survival of more than 1.00 log CFU/$100\;cm^2$ of viable cell was shown by washing of sodium hypochlorite solution at the same condition. On the other hand, the coliform group bacteria ($5.08{\pm}4.00\;CFU/100\;cm^2$) were detected on rubber globe only, and more than 2.00 log CFU/$100\;cm^2$ of viable cell and coliform group bacteria on it survived, though it was washed with flowing SEW for 30 sec.

Comparison of Characteristics on Electrolyzed Water Manufactured by Various Electrolytic Factors (전해인자에 따른 전기분해수의 특성 비교)

  • Kim, Myung-Ho;Jeong, Jin-Woong;Cho, Young-Je
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.416-422
    • /
    • 2004
  • Efficacy of surface sterilization and physicochemical properties of electrolyzed water manufactured depending on electrolyte, materials, and type of electrolytic diaphragm used were investigated. Physical properties of electrolyzed water manufactured from diaphragm system showed the highest effectiveness under at distance between diaphragms of 1.0 mm and 20% NaCl supplying rate of 6 mL/min. ORP, HClO (should defined) content, and pH at above conditions were 1,170 mV, 100 ppm, and 2.5, respectively. Two-stage electrolyzed system was more effective than one-stage one. Electrolyzed water manufactured from non-diaphragm system at 4 mL/min supplying rate of 20% NaCl was similar to the most effective diaphragm system, whereas ORP, HClO content, and pH were 800 mV, 200 ppm, and 9, respectively. Sealed electrolyzed water could be preserved more than one month at room temperature with ORPs of 750 and 1,150 mV in non-diaphragm and diaphragm systems, respectively, and at HClO content of 100 ppm. Physicochemical properties of electrolyzed water manufactured from electrolytic diaphragm of $IrO_{2}$ and Pt+Ir were more effective than that of Pt. ORP and HClO contents of electrolyzed water manufactured from various electrolytes were high in order of NaCl>KCl>$CaCl_{2}$, whereas no differences were observed among electrolytes in sterilization efficacy. Twelve kinds of microorganisms tested (initial total count, $10^{5}-10^{6}CFU/mL$) were sterilized within 1-2 min by electrolyzed water.

Sensitivity of Aerosol Optical Parameters on the Atmospheric Radiative Heating Rate (에어로졸 광학변수가 대기복사가열률 산정에 미치는 민감도 분석)

  • Kim, Sang-Woo;Choi, In-Jin;Yoon, Soon-Chang;Kim, Yumi
    • Atmosphere
    • /
    • v.23 no.1
    • /
    • pp.85-92
    • /
    • 2013
  • We estimate atmospheric radiative heating effect of aerosols, based on AErosol RObotic NETwork (AERONET) and lidar observations and radiative transfer calculations. The column radiation model (CRM) is modified to ingest the AERONET measured variables (aerosol optical depth, single scattering albedo, and asymmetric parameter) and subsequently calculate the optical parameters at the 19 bands from the data obtained at four wavelengths. The aerosol radiative forcing at the surface and the top of the atmosphere, and atmospheric absorption on pollution (April 15, 2001) and dust (April 17~18, 2001) days are 3~4 times greater than those on clear-sky days (April 14 and 16, 2001). The atmospheric radiative heating rate (${\Delta}H$) and heating rate by aerosols (${\Delta}H_{aerosol}$) are estimated to be about $3\;K\;day^{-1}$ and $1{\sim}3\;K\;day^{-1}$ for pollution and dust aerosol layers. The sensitivity test showed that a 10% uncertainty in the single scattering albedo results in 30% uncertainties in aerosol radiative forcing at the surface and at the top of the atmosphere and 60% uncertainties in atmospheric forcing, thereby translated to about 35% uncertainties in ${\Delta}H$. This result suggests that atmospheric radiative heating is largely determined by the amount of light-absorbing aerosols.

The Effects of Winch-curtain Ventilation on the Indoor Environment of a Fattening Swine House (윈치커튼 환기가 비육돈사의 실내 환경에 미치는 영향)

  • Kim, Hyeon-Tae;Song, Jun-Ik;Choi, Hong-Lim
    • Journal of Animal Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • The study was conducted to investigate the effects of climate on indoor environment of a swine house with natural. This study was tested in the beef swine stall at Young-in, Kyung-ki do. The test was experimented for the effect of interior environment by the outdoor environment and the interior-pan. The results are as follows. 1. In test 1 ($T_{out}$ : $25.7^{\circ}C$, without fan), an indoor air flow pattern was showed that entered from sidewall winch-curtain to went out of a indoor by the ridge winch-curtain. And the velocity of a section of the center was measured two times as large as the velocity of the floor. It is the acceleration of the velocity by thermal buoyancy. And, the entered air was rapidly dissipated by flow energy. So that in the swain livestock with sidewall winch-curtain is effected by thermal buoyancy. And the air temperature of the indoor was distributed more higher as compared with the outdoor temperature. This result is caused by the sensible heat from swine and the ventilation is restricted. 2. In test 2 (($T_{out}$ : $25.7^{\circ}C$, with fan), the velocity of a section of the center was measured more higher as compared with the test 1. And the variance of air velocity was distributed higher as compared with the test 1. This result is showed dead region of air flow with a fan operation. And, the variance of gas density was distributed lower as compared with the test 1.

Radiation, Energy, and Entropy Exchange in an Irrigated-Maize Agroecosystem in Nebraska, USA (미국 네브라스카의 관개된 옥수수 농업생태계의 복사, 에너지 및 엔트로피의 교환)

  • Yang, Hyunyoung;Indriwati, Yohana Maria;Suyker, Andrew E.;Lee, Jihye;Lee, Kyung-do;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.1
    • /
    • pp.26-46
    • /
    • 2020
  • An irrigated-maize agroecosystem is viewed as an open thermodynamic system upon which solar radiation impresses a large gradient that moves the system away from equilibrium. Following the imperative of the second law of thermodynamics, such agroecosystem resists and reduces the externally applied gradient by using all means of this nature-human coupled system acting together as a nonequilibrium dissipative process. The ultimate purpose of our study is to test this hypothesis by examining the energetics of agroecosystem growth and development. As a first step toward this test, we employed the eddy covariance flux data from 2003 to 2014 at the AmeriFlux NE1 irrigated-maize site at Mead, Nebraska, USA, and analyzed the energetics of this agroecosystem by scrutinizing its radiation, energy and entropy exchange. Our results showed: (1) more energy capture during growing season than non-growing season, and increasing energy capture through growing season until senescence; (2) more energy flow activity within and through the system, providing greater potential for degradation; (3) higher efficiency in terms of carbon uptake and water use through growing season until senescence; and (4) the resulting energy degradation occurred at the expense of increasing net entropy accumulation within the system as well as net entropy transfer out to the surrounding environment. Under the drought conditions in 2012, the increased entropy production within the system was accompanied by the enhanced entropy transfer out of the system, resulting in insignificant net entropy change. Drought mitigation with more frequent irrigation shifted the main route of entropy transfer from sensible to latent heat fluxes, yielding the production and carbon uptake exceeding the 12-year mean values at the cost of less efficient use of water and light.

Interannual Variation of the TOMS Total Ozone and Reflectivity over the Globe (전지구에 대한 TOMS 오존전량과 반사율의 경년 변화)

  • Yoo, Jung-Moon;Jeon, Won-Sun
    • Journal of the Korean earth science society
    • /
    • v.21 no.6
    • /
    • pp.703-718
    • /
    • 2000
  • In order to investigate interannual variation of total ozone and reflectivity over the globe, Nimbus-7/TOMS data were used on the monthly mean and its anomaly for the period of 1979-92. This study also examined MSU channel 4(Ch4; lower-stratosphere) brightness temperature data and two model reanalyses of NCEP and GEOS to compare the ozone variation with atmospheric thermal condition. In addition, the MSU channel 1(Ch1 ; lower-troposphere) brightness temperature was used to compare with the reflectivity. The ozone showed strong annual cycle with downward trend(-6.3${\pm}$0.6 DU/decade) over the globe, and more distinct response to volcanic eruption than El Ni${\tilde{n}$o. The relationship between total ozone and MSU Ch4 observation, and between the ozone and model reanalyses of lower stratosphere temperature showed positive correlation(0.2-0.7) during the period of 1980-92. Reflectivity increased interannually by 0.2${\pm}$0.06%/decade over the globe during the above period and reflected El Ni${\tilde{n}$o(1982-83, 1991-92) well. Its variability in annual cycle was remarkably smaller in tropics than in higher latitudes. This is inferred due to cloud suppression and tropical upwelling regions. Reflectivity correlated negatively(-0.9) to the Ch1 temperature over the globe, but positively(0.2) over tropical ocean. The positive value over the ocean results from the effect of microwave emissivity which increases the Ch1 temperature with enhanced hydrometeor activity. Significant correlations between total ozone and the Ch4 temperature, and between reflectivity and the Ch1 Suggest that the TOMS data may use valuably to better understand the feedback mechanism of climate change.

  • PDF

Evaluating Impact Resistance of Externally Strengthened Steel Fiber Reinforced Concrete Slab with Fiber Reinforced Polymers (섬유 보강재로 외부 보강된 강섬유 보강 콘크리트 슬래브의 충격저항성능 평가)

  • Yoo, Doo-Yeol;Min, Kyung-Hwan;Lee, Jin-Young;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.293-303
    • /
    • 2012
  • Recently, as construction technology improved, concrete structures not only became larger, taller and longer but were able to perform various functions. However, if extreme loads such as impact, blast, and fire are applied to those structures, it would cause severe property damages and human casualties. Especially, the structural responses from extreme loading are totally different than that from quasi-static loading, because large pressure is applied to structures from mass acceleration effect of impact and blast loads. Therefore, the strain rate effect and damage levels should be considered when concrete structure is designed. In this study, the low velocity impact loading test of steel fiber reinforced concrete (SFRC) slabs including 0%~1.5% (by volume) of steel fibers, and strengthened with two types of FRP sheets was performed to develop an impact resistant structural member. From the test results, the maximum impact load, dissipated energy and the number of drop to failure increased, whereas the maximum displacement and support rotation were reduced by strengthening SFRC slab with FRP sheets in tensile zone. The test results showed that the impact resistance of concrete slab can be substantially improved by externally strengthening using FRP sheets. This result can be used in designing of primary facilities exposed to such extreme loads. The dynamic responses of SFRC slab strengthened with FRP sheets under low velocity impact load were also analyzed using LS-DYNA, a finite element analysis program with an explicit time integration scheme. The comparison of test and analytical results showed that they were within 5% of error with respect to maximum displacements.

Behavior of Steel Fiber-Reinforced Concrete Exterior Connections under Cyclic Loads (반복하중을 받는 강섬유 보강 철근콘크리트 외부 접합부의 거동 특성)

  • Kwon, Woo-Hyun;Kim, Woo-Suk;Kang, Thomas H.K.;Hong, Sung-Gul;Kwak, Yoon-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.711-722
    • /
    • 2011
  • Beam-column gravity or Intermediate Moment frames subjected to unexpected large displacements are vulnerable when no seismic details are provided, which is typical. Conversely, economic efficiency of those frames is decreased if unnecessary special detailing is applied as the beam and column size becomes quite large and steel congestion is caused by joint transverse reinforcement in beam-column connections. Moderate seismic design is used in Korea for beam-column connections of buildings with structural walls, which are to be destroyed when the unexpected large earthquake occurs. Nonetheless, performance of such beamcolumn connections may be substantially improved by the addition of steel fibers. This study was conducted to investigate the effect of steel fibers in reinforced concrete exterior beam-column connections and possibility for the replacement of some joint transverse reinforcement. Ten half-scale beam-column connections with non-seismic details were tested under cyclic loads with two cycles at each drift up to 19 cycles. Main test parameters used were the volume ratio of steel fibers (0%, 1%, 1.5%) and joint transverse reinforcement amount. The test results show that maximum capacity, energy dissipation capacity, shear strength and bond condition are improved with the application of steel fibers to substitute transverse reinforcement of beam-column connections. Furthermore, several shear strength equations for exterior connections were examined, including the proposed equation for steel fiber-reinforced concrete exterior connections with non-seismic details.