• 제목/요약/키워드: 소산 효과

Search Result 202, Processing Time 0.023 seconds

Evaluation of Flexural Behavior of Masonry Members Reinforced with Engineered Cementitious Composite (고인성 복합체로 보강한 조적부재의 휨 거동 평가)

  • Yang, Seung-Hyeon;Kim, Sun-Woong;Kim, Jae-Hwan;Kang, Suk-Pyo;Hong, Seong-Uk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.37-45
    • /
    • 2021
  • This paper is a basic study to evaluate the possibility of earthquake-resistant reinforcement by reinforcing engineered cementitious composite in masonry members. In order to examine the performance according to the fiber mixing rate of the engineered cementitious composite, a test specimen was prepared according to the formulation design, and flow ability, compressive strength, flexural strength, length change rate, and direct tensile strain were measured. In addition, non-reinforced masonry members, masonry members reinforced with engineered cementitious composite, and masonry members in which glass fibers and wire mesh were separately reinforced with engineered cementitious composites were manufactured, and flexural strength and maximum displacement were measured. All specimens reinforced with engineered cementitious composite showed more than 16 times the effect of maximal strength compared to that of no reinforcement, and as a result of examining the crack shape, the energy dissipation ability was excellent, confirming the possibility of seismic reinforcement.

Estimation of Nonlinear Site Effects of Soil Profiles in Korea (국내 지반에서의 비선형 부지효과 예측)

  • Lee, Hong-Sung;Yun, Se-Ung;Park, Du-Hee;Kim, In-Tai
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.3
    • /
    • pp.13-23
    • /
    • 2008
  • In a nonlinear site response analysis which is performed in time domain, small strain damping is modeled as viscous damping through use of various forms of Rayleigh damping formulations. Small strain damping of soil is known to be independent of the loading frequency, but the viscous damping is greatly influenced by the loading frequency. The type of Rayleigh damping formulation has a pronounced influence on the dependence. This paper performs a series of nonlinear analyses to evaluate the degree of influence of the viscous damping formulation on Korean soil profiles. Analyses highlight the strong influence of the viscous damping formulation for soil profiles exceeding 30 m in thickness, commonly used in simplified Rayleigh damping formulation overestimating energy dissipation at high frequencies due to artificially introduced damping. When using the full Rayleigh damping formulation and carefully selecting the optimum modes, the artificial damping is greatly reduced. Results are further compared to equivalent linear analyses. The equivalent linear analyses can overestimate the peak ground acceleration even for shallow profiles less than 20 m in thickness.

Hysteretic Damage Model for Reinforced Concrete Joints Considering Bond-Slip (부착-슬립을 고려한 철근콘크리트 접합부의 이력 손상 모델 개발)

  • Kim, Do-Yeon;Choi, In-Kil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.517-528
    • /
    • 2008
  • This paper presents a hysteretic damage model for reinforced concrete (RC) joints that explicitly accounts for the bond-slip between the reinforcing bars and the surrounding concrete. A frame element whose displacement fields for the concrete and the reinforcing bars are different to permit slip is developed. From the fiber section concept, compatibility equations for concrete, rebar, and bond are defined. Modification of the hysteretic stress-strain curve of steel is conducted for partial unloading and reloading conditions. Local bond stress-slip relations for monotonic loads are updated at each slip reversal according to the damage factor. The numerical applications of the reinforcing bar embedded in the confined concrete block, the RC column anchored in the foundation, and the RC beam-column subassemblage validate the model accuracy and show how including the effects of bond-slip leads to a good assessment of the amount of energy dissipation during loading histories.

Proposal and Performance Verification of a Seismic Adapter for Steel Brace Connections for In-plane Reinforcement of School Buildings (학교 건축물의 면내보강을 위한 강재브레이스 접합용 내진어댑터의 상세 제안 및 성능검증)

  • Seokjae Heo;Lan Chung;In-Kwan Paik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.162-171
    • /
    • 2023
  • In this study, The details for a seismic adapter designed to easily connect concrete structures and reinforcement materials for the in-plane reinforcement of aged structures were proposed. Proposed seismic adapter was tested for performance using a dynamic simulation on a 2-story column-beam structure, scaled to half of the real size. The experimental results showed that the reinforced test specimens using the seismic adapter improved their energy dissipation capacity by 3.5 times compared to the non-reinforced specimens. It was confirmed that the seismic adapter experienced no damage within its general usage range, thus proving its effectiveness. Subsequently, upon loading until the limit of deformation (a deformation angle of 3.3%), it was observed that one of the M10 bolts connecting the adapter and the reinforcement at the lower part of the first floor broke. Considering this finding, when applying seismic retrofitting in real situations, emphasis should be placed on the design of the bolts and anchors connecting the seismic adapter. This aspect warrants further research for validation.

Experimental Study on the Characteristics of Turbulent Wall Pressure Fluctuation Over Compliant Coatings (유연재 코팅 평판의 난류 변동압력 특성에 관한 실험적 연구)

  • Park, Kyung-Hoon;Lee, Seung-Jae;Shin, Ku-Kyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.6
    • /
    • pp.293-300
    • /
    • 2007
  • Turbulent boundary layer over an underwater vehicle is formed when it moves underwater and wall pressure fluctuation within the turbulent boundary layer generates flow-induced noise by exciting the elastic hull of the underwater vehicle. One of the methods to reduce this flow noise is to attach a compliant layer on the surface of the vehicle. In order to observe the possibility of noise reduction in the water when the compliant layer treatments are applied on the surface, three types of specimens those are a bare steel plate, a steel plate coated with neoprene and a steel plate with polyurethane coating material are tested at various flow speeds in a low noise cavitation tunnel. This paper presents the results of measurements and analysis of wall pressure fluctuations which is a main source of flow noise, within the turbulent boundary layer on three specimens. Its results could be shown that about 10dB reduction of wall fluctuation pressure at high frequencies was achieved due to the dissipation of turbulent energy by the compliant coating while it makes the turbulent boundary layer thicker and changes the behavior of turbulent flow in the layer.

A Critical Liquefaction Resistible Characteristic of Saturated Sands Based on the Cyclic Triaxial Test Under Sinusoidal Loadings (정현하중재하 진동삼축시험에 기초한 포화사질토의 액상화 한계저항특성)

  • 최재순;김수일
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.8
    • /
    • pp.147-158
    • /
    • 2004
  • Laboratory dynamic tests are carried out to assess the liquefaction potential of saturated sands in most countries. However, simple results such as the maximum cyclic shear stress and the number of cycles at initial liquefaction are used in the experimental assessment of liquefaction potential, even though various results can be obtained from the dynamic test. In addition, it seemed to be inefficient because more than three dynamic tests with different stress ratio have to be carried out to draw a liquefaction resistance experimental curve. To improve the present assessment method fur liquefaction potential, a new critical resistible characteristic far soil liquefaction is proposed and verified through conventional cyclic triaxial tests with Jumunjin sand. In the proposed method, various experimental data such as effective stress path, stress-strain relationship, and the change of excess pore water pressure can be used in the determination of cumulative plastic shear strains at every 1/4 cycle. Especially, the critical cumulative plastic shear strain to initiate liquefaction can be defined in a specific point called a phase change point in the effective stress path and it can be calculated from a hysteric curve of stress-strain relationship up to this point. Through this research, it is found that the proposed cumulative plastic shear strain can express the dissipated energy to resist dynamic loads and consider the realistic soil dynamic behavior of saturated sands reasonably. It is also found that the critical plastic shear strain can be used as a registible index of soils to represent the critical soil dynamic state, because it seems to include no effect of large deformation.

Experimental Study on the Performance Improvement of Velcro Reinforcement through Internal Filling (내부충진을 통한 벨크로 보강재의 성능향상에 대한 실험적 연구)

  • Jeong, Yeong-Seok;Kwon, Minho;Kim, Jin-Sup;Nam, Gwang-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.347-355
    • /
    • 2021
  • During the earthquake, for multi-story structure, if the first floor is soft, the deformation will concentrate on that floor causing a serious damage to the column members which might leads to the collapse of the whole structure like Piloti structure during the Pohang earthquake in Korea. According to the 2016 National Disaster Management Research Institute's "Investigation of Seismic Reinforcement and Cost Analysis of Domestic Non-seismic Buildings", the rate of seismic resistance of private reinforced concrete buildings was 38.3 %. Among them, it was reported that the seismic-resistance ratio of the two to five-story structures was less than 50 %. Accordingly, the government is trying to improve the seismic rate through support projects, but the conventional seismic reinforcement methods are still expensive, and emergency construction is difficult. Therefore, in this study, the field applicability was evaluated by improving the reinforcement method using Velcro, which was developed through the research project of the Ministry of Land, Transport and Maritime Affairs in 2014. In order to improve the performance of the Velcro reinforcement method, introducing the initial tension of Velcro using high foaming rigid urethane filling between the Velcro and concrete of the columns was applied. Additionally, an experiment was conducted to evaluate the ductility of Velcro specimen from the concrete confinement effect. As a result, the ductility of the Velcro specimen was improved compare to Normal specimen. However, the energy dissipation capacity of VELCRO2 is better than VELCRO1, yet the maximum ductility of those two specimens did not show a significant difference. Therefore, the improvement of the internal filler material is still needed to have a better maximum ductility.

Evaluation of Seismic Performance of High Strength Reinforced Concrete Exterior Beam-Column Joints Using High Ductile Fiber-Reinforced Mortar (고인성섬유 복합모르타르를 활용한 고강도 철근콘크리트 외부 보-기둥 접합부의 내진성능평가)

  • Ha, Gee-Joo;Shin, Jong-Hak
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.4
    • /
    • pp.419-428
    • /
    • 2013
  • In this study, experimental research was carried out to evaluate the constructability and seismic performance of high strength R/C exterior beam-column joints regions, with or without the shear reinforcement, using high ductile fiber-reinforced mortar. Five specimens of retrofitted the exterior beam-column joint regions using high ductile fiber-reinforced mortar are constructed and tested for their retrofit performances. Specimens designed by retrofitting the exterior beam-column joint regions (BCJNSP series) of existing reinforced concrete building showed a stable mode of failure and an increased its maximum load-carrying capacity by 1.09~2.03 times in comparison with specimen of BCJNS due to the effect of enhancing dispersion of crack control at the time of initial loading and bridging of fiber from retrofitting new high ductile materials during testing. Specimens of BCJNSP series attained its maximum load carrying capacity by 0.92~0.96 times and increased its energy dissipation capacity by 1.62 times when compared to standard specimen of BCJC with a displacement ductility of 4.

Effect of inhibition on Browning and Microbial Growth of Minimally Processed Lettuce (최소가공 처리에 의한 양상추의 갈변 및 미생물 증식억제 효과)

  • Cha Hwan-Soo;Kim Soon-1m;Kim Byeong-Sam;Kim Sang-Hee;Park Seon-Ju;Cho Han-Sun;chd Hye-Yeon
    • Food Science and Preservation
    • /
    • v.11 no.3
    • /
    • pp.331-335
    • /
    • 2004
  • This study was carried out to improve quality of minimally processed lettuce with various treatments. The treatments for preventing enzymatic browning were using different chemical immersion solutions and controlling microbial growth were using chlorine, electrolyzed water, and organic acid. The solution with ascorbic acid 1$\%$ and citric acid 1 $\%$ showed a positive effect on antibrowning of minimally processed lettuce. In the inhibition of microorganisms growth, 200 ppm NaCIO solution was more effective than fermented pollen solution and Na-dichloroisocyanurate solution. In electrolyzed water system, no-diaphragm system showed inhibitory effect of microorganisms growth. Also, total microorganisms count of minimally processed lettuce with ascorbic acid and citric acid solution was lower by about 4 log cycle after 4 days storage at l0$^{\circ}C$.

Microbial Analysis of Baechu-kimchi during Automatic Production Process (배추김치의 자동화 제조 공정 중 미생물 분석)

  • Kim, Ji-Sun;Jung, Jee-Yun;Cho, Seung-Kee;Kim, Ji-Eun;Kim, Tae-Jip;Kim, Beom-Soo;Han, Nam-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.281-286
    • /
    • 2010
  • The objective of this study was to analyze the microbial populations in the raw ingredients of kimchi and their changes during an automated commercial manufacturing process. High population numbers of total aerobic bacteria, lactic acid bacteria, Leuconostoc sp., and yeast were detected in garlic, ginger, red pepper powder and this result revealed that these ingredients were the major source of microbials in kimchi. Additionally, during the salting process of Chinese cabbage, rapid microbial growth was observed and the consecutive washing process was determined to be ineffective, lowering the microbial count by only one log reduction. Yeast was also detected in various ingredients. These results strongly suggest that, in order to lower the microbial population numbers in kimchi, the side-ingredients and salting process should be subjected to the appropriate sanitization or sterilization processes at the HACCP level. Beside, treatment of salted Chinese cabbage with sodium hypochlorite solutions after the salting step is recommended. To inhibit yeast growth, appropriate chemical treatment and approval of additive uses to control microbials should be considered. These experimental results and suggestions will be used to improve the kimchi manufacturing process in factories.