A Study on Measures to Improve Smoke Control Performance in Case of Fire in a Clean room as an LCD Manufacturing Process (LCD 제조공정 클린룸의 화재시 CFD를 이용한 제연성능 개선대책에 관한 연구)

  • Son, Bong-Sei;Jang, Chan-Hee
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.41-47
    • /
    • 2012
  • As a core process in the manufacture of state-of-the-art industrial technologies such as semiconductor and LCD, a clean room is the most important process which can affect the performance and quality of products drastically. Nevertheless, scientific research on comprehensive safety measures from a fire protection standpoint is not being carried out in Korea. This study aims to derive measures to improve smoke control systems by identifying performance and problems of smoke systems installed in clean rooms as an LCD manufacturing process and analyzing fire and evacuation simulations considering several scenarios. As a result of analysis of fires and smoke in a clean roomas an LCD manufacturing process, it is found to be necessary to stop air handling units through interlocking in case of a fire and exhaust smoke out of the room through the top of FAB in consideration of buoyancy of smoke. It is also found to be necessary to install quick response sprinkler heads and accessories to accelerate the response time, because the heat-accumulating performance of sprinkler heads decreases in this application. Despite its low density of dwelling due to the automation process, clean room is characterized by an array of complex production equipment and working environment requiring dustproof clothes, which makes it difficult to acquire evacuation safety performance. Thus, thorough control of danger factors in processes and periodic education and training are required. It is also necessary to establish a level of domestic technologies equivalent to the level of standards of advanced countries in fire protection.

Assessment of Fire Risk Rating for Wood Species in Fire Event (화재 발생 시 목재 수종의 화재위험성 등급 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.423-430
    • /
    • 2021
  • In order to evaluate the fire risk and fire risk rating of wood for construction materials, this study focused on fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) according to Chung's equations-III and -IV. Western red cedar, needle fir, ash, and maple were used as the specimens. The fire characteristics were investigated using a cone calorimeter (ISO 5660-1) equipment on the specimen. The FPI-III measured after the combustion reaction was 0.86 to 12.77 based on polymethylmethacrylate (PMMA). The FGI-III was found to be 0.63 to 5.26 based on PMMA. The fire rating according to the FRI-IV, which is the fire rating index, was 0.05 to 6.12, and the western red cedar was 122.4 times higher than that of the maple. The fire risk rating according to the FRI-IV increased in the order of maple, ash, needle fir, PMMA and western red cedar. The CO peak concentration of all specimens was measured as 103 to 162 ppm, and it was 2.1 to 3.2 times higher than 50 ppm, the permissible exposure limits of the US occupational safety and health administration. Materials such as western red cedar, which have a low bulk density and contain a large amount of volatile organic substances, have a low FPI-III and a high FGI-III, so they have a high fire risk rating.

A Study on Flammability Risk of Flammable Liquid Mixture (가연성 액체 혼합물의 인화 위험성에 관한 연구)

  • Kim, Ju Suk;Koh, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.701-711
    • /
    • 2020
  • Purpose: In this study, the risk of flammability of a liquid mixture was experimentally confirmed because the purpose of this study was to confirm the increase or decrease of the flammability risk in a mixture of two substances (combustible+combustible) and to present the risk of the mixture. Method: Flash point test method and result processing were tested based on KS M 2010-2008, a tag sealing test method used as a flash point test method for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was Japan's TANAKA. The flash point was measured with a test equipment that satisfies the test standards of KS M 2010 with equipment produced by the company, and LP gas was used as the ignition source and water as the cooling water. In addition, when measuring the flash point, the temperature of the cooling water was tested using cooling water of about 2℃. Results: First of all, in the case of flammable + combustible mixtures, there was little change in flash point if the flash point difference between the two substances was not large, and if the flash point difference between the two substances was low, the flash point tended to increase as the number of substances with high flash point increased. However, in the case of toluene and methanol, the flash point of the mixture was lower than that of the material with a lower flash point. Also, in the case of a paint thinner, it was not easy to predict the flash point of the material because it was composed of a mixture, but as a result of experimental measurement, it was measured between -24℃ and 7℃. Conclusion: The results of this study are to determine the risk of mixtures through experimental studies on flammable mixtures for the purpose of securing the effectiveness of the details of the criteria for determining dangerous goods in the existing dangerous goods safety management method and securing the reliability and reproducibility of the determination of dangerous goods Criteria have been presented, and reference data on experimental criteria for flammable liquids that are regulated in firefighting sites can be provided. In addition, if this study accumulates know-how on differences in test methods, it is expected that it can be used as a basis for research on risk assessment of dangerous goods and as a basis for research on dangerous goods determination.

Counter-terrorism Safety Measures in Public Facilities (다중이용시설의 대테러 안전대책)

  • Kim, Du-Hyun;Ahn, Kwang-Ho
    • Korean Security Journal
    • /
    • no.22
    • /
    • pp.37-64
    • /
    • 2010
  • Since the September 11, 2001, the motives and objectives of terrorism that have been targeted at hard targets such as key national facilities have now shifted towards soft targets such as subways, department stores, and tourist hotels; the attacks on these soft targets are steadily increasing. Simultaneous, unconventional, and indiscriminate terrorist attacks on civilians has also increased. In November, 2010, nearly forty states of the G20 and B20 (Business 20) will join in international summits to be hosted in Seoul. This coming July, an additional 350 troops will be deployed to Afghanistan for the sustainment of public security. Such events are sensitive topics, and there is the possibility of terrorist movement. Korea has successfully hosted various international events such as the APEC and ASEM Summits, and the 2002 Korea-Japan World Cup. The experiences from these events must be applied to ensure the safety of public facilities against the dangers of terrorism. First, counter-terrorism center must be established for the long-term, above the General Officer level to ensure the safety and efficiency of multilateral, international summits, as well as promoting policies and legislation aimed at preventing terrorism. Second, a terrorist threat management system must be secured and safety measures must be emphasized. Third, a fundamental structure must be established for the prevention of terrorism on public facilities, as well as legal and government action against the new threat of IED. Fourth, the police and fire fighting networks' must have a firm rapid response posture on the scene of an attack. Fifth, the state of mentality on the recognition of terrorist threats must be changed and restructured by promoting to and educating the population. Sixth, prevention measures must be established via research and academia. Seventh, for the guarantee of security in public facilities, safety management should employ cutting edge technology such as the 3D SICS and further develop and apply such technology. All methods and resources must be fully utilized for the establishment and strengthening terrorism prevention measures.