Analysis of RSET According to Exit Installation Standards for the Exterior of a Food Manufacturing Plant Building (식품공장 건축물 바깥쪽으로의 출구 설치기준에 따른 RSET 분석)

  • Park, Ha-Soung;Lee, Jae-Wook;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.201-208
    • /
    • 2024
  • In this study, we investigated whether the evacuation time according to the exit installation standards specified in the building code during a food factory fire is compatible with the evacuation time based on the performance-based design specified by the fire department, in order to determine if evacuation safety is ensured. We used the Pathfinder program to confirm the evacuation time, and experimented with three scenarios for exit installation standards towards the outside of the building: 60m, 80m, and 100m. The target building in the experiment corresponded to the building code's exit installation standard of 100m from each dwelling. The experimental results showed tt in the cases of 80m and 100m, ASET exceeded RSET, indicating tt evacuation safety was not ensured, while in the case of 60m, evacuation safety was maintained. Through this study, it was confirmed tt even when the exit installation standards towards the outside of the building are met, evacuation safety may not be guaranteed.

The Study on the Developing Process and the Tasks from Now of the Fire Industry in Korea (한국소방산업의 발전과정과 향후과제의 고찰)

  • Kim, Tae-Hwan;Nam, Sang-Ho
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.112-124
    • /
    • 2008
  • The extra session of the 17th National Assembly convened lastly had passed the law on the promotion of the fire industry. Therefore, the development of the fire industry discussed insignificantly in accordance with the establishment of the law. In this important time, this study was intended to derive tasks for development through researching the concept and developing process of the fire industry and forecasting the industry. For defining the concept of the fire industry, this study researched meaning, the present status and features of the industry. For study of developing process of the fire industry, this study analysed fire law and system, fire codes, fire products and development of fire market. The analyses were processed as a unit of every 10 years from 1960's. Consequently, this study presented some tasks for development of the fire industry such as fire inspection system, fire products circulation system, separated ordering system, managing system of fire facilities and technical R & D of the fire industry based on analysing and forecasting the fire industry.

A Study on the Safety Management Standards and Safety Indicators Private Lodging in Farming and Fishing Villages in Rural Area (농어촌민박의 안전관리 기준 및 안전지표에 관한 연구)

  • Suh, hey-sung;Lee, Yong-soo;Kim, Youna-ah
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • Various support is provided for the increase in the number of private lodging users in farming and fishing villages and related government policies. However, the bed-and-breakfast accommodation in rural areas lack safety standards or safety indicators for the service pension Gangneung, carbon monoxide leak accident in December 2018, 2020 East Sea in January, Pension. Large gas explosion, accident and is threatening the security of their citizens. Unlike lodging facilities, private lodging in farming and fishing villages is allowed to operate with certain requirements such as fire extinguishers and fire alarms. The purpose of this study is to present safety standards and safety indicators for lodging facilities in farming and fishing villages, which are necessary for the operation management and inspection of local governments and the government related to lodging in farming and fishing villages. Through the study, safety management areas of private lodging in farming and fishing villages were divided into facility safety, fire safety, food safety and living safety, and detailed inspection indicators were presented. There is an academic implication that research on safety management of lodging facilities has been expanded through safety research in areas related to private lodging in farming and fishing villages. It has practical implications in that it provides management standards and indicators that can be used for safety management of private lodging in farming and fishing villages. The limitations of this study are that more studies on private lodging in farming and fishing villages are expected to be conducted through the results of this study, and the lack of research on accommodation safety has prevented more detailed indicators from being derived.

Improvement of cultural heritage disaster management - The Case of Sungnyemun's Collapse in Fire - (문화재 재난관리의 필요성과 발전방향 - 숭례문 화재사고사례를 중심으로 -)

  • Han, Beum-Deuk
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.10
    • /
    • pp.189-197
    • /
    • 2008
  • The present study purposed to assert the necessity of cultural property disaster control through analyzing the fire of the Sungnyemun and to suggest directions for the development of cultural property disaster control in the future. For these purposes, we reviewed literature such as research papers and books on cultural property disaster control, and presented problems in current cultural property disaster control and solutions for the problems through case study of the fire of the Sungnyemun. In a word, the fire of the Sungnyemun is a representative case showing difficulty in disaster prevention activities for wooden cultural properties. Accordingly, we need to recognize the necessity of cultural property disaster control and to prepare measures. For this, first, it is essential to reinforce preventive systems against cultural property disasters. Second, early actions should be taken in consideration of the characteristics of each cultural property. Third, for cultural property disaster control, it is important to maintain cooperative relations among the Cultural Properties Administration, National Emergency Management Agency, and relevant local self.governing bodies. Lastly, standards for cultural property fire protection systems should be tightened by improving related laws, and institutional bases should be intensified through preparing grounds for aggravated punishment for crimes against cultural properties such as arsons.

A Study on Required Safe Egress Time (RSET) Comparison and Error Calculation in Relation to Fire Room Range Set Conditions of Performance Based Fire Safety Designers (성능위주설계자들의 화재실 범위 설정 방식에 따른 소요피난안전시간(RSET) 비교 및 오차산정에 관한 연구)

  • Baek, Sona;Choi, Jun-Ho;Hong, Won-Hwa;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.73-78
    • /
    • 2016
  • The Installation, Maintence, and Safety Control of Fire-fighting Systems Act of South Korea regulates that over 30-storey high-rise buildings including underground spaces should vitally perform the Performance-based Design to minimize property damage and personal injury as a fire risk assessment in advance. Therefore a PBD designer such as a fire safety professional engineer evaluate occupant's life safety by a scientific methodology. In order to evaluate the life safety, fire safety designers calculate the Required Safety Egress Time (RSET) which does not have the legal criteria regarding the standard method of calculation yet. So this way has been showing different results depending upon the designer's choice, knowledges and experiences. In this study, RSET calculation methods by six designers respectively were analysed from the thirteen reports of real performance based design projects conducted in Busan for a last five years. In particular, the Response Time calculation methods which have the most powerful effect for figuring the RSET are compared with the other designer's to deduce an error value.

A Study on Fire Safety Measure for Korean Utility Tunnels Based on Analysis of Fire Safety Performance for Utility Tunnel in Advanced Countries (해외 공동구의 방재성능분석을 통한 국내 공동구에 적합한 방재대책에 관한 연구)

  • 박형주;김상욱
    • Fire Science and Engineering
    • /
    • v.15 no.4
    • /
    • pp.71-77
    • /
    • 2001
  • The pipes and cables buried below ground which may have helped to improved city landscapes is becoming direct and indirect cause for various disaster in Korea due to potential possibility of fire. Various types of fire in utility tunnels should be analysed in order to improve its fire safety level, therefore mail problems and shortcomings are checked out as a result of this analysis. By performing both tunnel fire risk analysis and fire safety level comparison in advanced countries, effective measure and approach to required standardization may be presented to bath tunnel structure and its containing cables in order to diminished up to a desirable rate in a near future.

  • PDF

Analysis of Evacuation Time According to Variation of Evacuation Stairs' Width in Large-Scale Goshiwons (대규모 고시원의 피난계단 폭의 변화에 따른 피난소요시간 분석)

  • Oh, Su-cheol;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.641-651
    • /
    • 2022
  • This research compares and analyzes evacuation time depending on the change in stair width in case of fire at Goshiwons. For this, a simulation has been conducted based on possible evacuation time according to the calculation method for the number of people admittable to a specific target for fire fighting equipped with accommodation. Currently, Gosiwon, which is classified as an accommodation facility (a total floor area of 500 m2 or more), uses blind spots prescribed by the Fire Services Act, Building Act, and Parking Act to build a high-rise building on a small area of land, and most Gosiwon is transformed into a modified accommodation. This is in line with the owner's operating profit, so it is expected to show a continuous increase. Securing the golden time of Gosiwon evacuation time is the last bastion of Gosiwon residents who belong to the economically disadvantaged in our society, and we hope this study will serve as a starting point for discussions on revising related laws and regulations to establish a social safety net As a result of the evacuation simulation analysis, the evacuation time was the least when the width of the group and the evacuation stairs were expanded to 200cm, and the evacuation time of the existing building was reduced by up to 166.3 seconds by comparing 648.4 seconds and scenario 6. This analysis can be meaningful, in that the width of the evacuation stairs revision of related laws and regulations for the safety of multiplex available premises.

Analysis of Soil Changes in Vegetable LID Facilities (식생형 LID 시설의 내부 토양 변화 분석)

  • Lee, Seungjae;Yoon, Yeo-jin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.204-212
    • /
    • 2022
  • The LID technique began to be applied in Korea after 2009, and LID facilities are installed and operated for rainwater management in business districts such as the Ministry of Environment, the Ministry of Land, Infrastructure and Transport, and LH Corporation, public institutions, commercial land, housing, parks, and schools. However, looking at domestic cases, the application cases and operation periods are insufficient compared to those outside the country, so appropriate design standards and measures for operation and maintenance are insufficient. In particular, LID facilities constructed using LID techniques need to maintain the environment inside LID facilities because hydrological and environmental effects are expressed by material circulation and energy flow. The LID facility is designed with the treatment capacity planned for the water circulation target, and the proper maintenance, vegetation, and soil conditions are periodically identified, and the efficiency is maintained as much as possible. In other words, the soil created in LID is a very important design element because LID facilities are expected to have effects such as water pollution reduction, flood reduction, water resource acquisition, and temperature reduction while increasing water storage and penetration capacity through water circulation construction. In order to maintain and manage the functions of LID facilities accurately, the current state of the facilities and the cycle of replacement and maintenance should be accurately known through various quantitative data such as soil contamination, snow removal effects, and vegetation criteria. This study was conducted to investigate the current status of LID facilities installed in Korea from 2009 to 2020, and analyze soil changes through the continuity and current status of LID facilities applied over the past 10 years after collecting soil samples from the soil layer. Through analysis of Saturn, organic matter, hardness, water contents, pH, electrical conductivity, and salt, some vegetation-type LID facilities more than 5 to 7 years after construction showed results corresponding to the lower grade of landscape design. Facilities below the lower level can be recognized as a point of time when maintenance is necessary in a state that may cause problems in soil permeability and vegetation growth. Accordingly, it was found that LID facilities should be managed through soil replacement and replacement.

A Study on Identifying Problems by the Comparative Analysis of High-Rise Apartment Evacuation Design Codes (고층 아파트 피난설계기준 비교분석을 통한 문제점 도출 연구)

  • Hwang, Eun-Kyoung;Seo, Dong-Goo
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.47-52
    • /
    • 2017
  • The recent tragic outbreak of fire at the Grenfell Tower in the United Kingdom compels all branches of government to reexamine and reassess the safety measures against fires in high-rise buildings from a broad perspective. Accordingly, this study examined what problems stem from the current evacuation codes by comparative analysis of the high-rise apartment evacuation codes that range over various individual laws before introducing a new evacuation code. The outcome of this study can be utilized as basic data for amending the existing evacuation codes for high-rise buildings. The codes related to high-rise building evacuation include the Building Act, the Housing Act, the Skyscraper Disaster Management Act, and the Fire-Fighting System Act. Some local governments have also drawn up their own codes and put them into practice. Comparative analysis of the major evacuation codes has helped identify a variety of problems, such as different codes being applied to each individual law and ordinance, the use of additional codes other than the provisions of laws and ordinances, and the in effectiveness of evacuation codes. Most of these problems occur when diverse codes are applied to a single building, which means that cooperation among the relevant ministries is urgently needed to improve the related codes in the future.

A Study on the Estimation Method of the Repair Rates in Finishing Materials of Domestic Office Buildings (국내 업무시설 건축 마감재의 수선율 산정 방안에 관한 연구)

  • Kim, Sun-Nam;Yoo, Hyun-Seok;Kim, Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.52-63
    • /
    • 2015
  • Business facilities among domestic architectures have rapidly been constructed along with domestic economic development. It is an important facility taking the second largest proportion next to apartment buildings among current 31 building types of fire department classification of 2012 year for urban architectures. The expected service life of business facilities is 15 years, but 70% of those in urban areas have surpassed the 15 year service life as of the present 2014. Thus, the demand for urgent rehabilitation of such facilities is constantly increasing due to the aging and performance deterioration of the facilities'main finishing materials. Especially, the business facilities are being used for the lease of company office or private office, and such problems as aging and performance deterioration of the facilities could cause less competitive edge for leasing and real estate value depreciation for the O&M (Operation & Management) agent and the owner, respectively. Therefore, an effective planned rehabilitation as a preventive measure according to the standardized repair rate by the number of years after the construction is in need in order to prevent the aging and performance deterioration of the facilities(La et al. 2001). Nonetheless, domestic repair/rehabilitation standards based on the repair rate are mainly limited to apartment buildings and pubic institutions, resulting in impractical application of such standards to business facilities. It has been investigated and analyzed that annual repair rate data for each finishing material are required for examination of the applicability of the repair rate standard for the purpose of establishment of a repair plan. Hence, this study aimed at developing a repair rate computation model for finishing materials of the facilities and verifying the appropriateness of the annual repair rate for each finishing material through a case study after collecting and analyzing the repair history data of six business facilities. The results of this study are expected to contribute to the planning and implementation of more efficient repair/rehabilitation budget by preventing the waste of unpredicted repair cost and opportunity cost for the sake of the business facilities' owners and O&M agents.