• Title/Summary/Keyword: 소규모수도시설

Search Result 28, Processing Time 0.022 seconds

Characteristics of Radon Reduction of Small-scale Water Supply System (소규모수도시설 지하수의 라돈저감 특성)

  • Cho, Byong-Wook
    • The Journal of Engineering Geology
    • /
    • v.29 no.1
    • /
    • pp.37-50
    • /
    • 2019
  • It is possible that radon removal in groundwater of small-scale water supply system (SWSS) is caused by atmospheric storage and aeration facilities installed in the water tank. Radon removal rates at water tank and tap of the 32 SWSS during summer season ranged from -69.3% to 62.7% (average 25.7%) and from -64.3% to 83.1% (average 30.3%) while those of 16 SWSS during autumn season ranged from 21.3% to 78.0% (average 42.8%) and from 17.7% to 66.9% (average 44.8%). The reason of higher radon removal rate in the autumn season compared with the summer season is due to higher atmospheric storage effect by lower groundwater use rate. The radon removal rates at the water tank from 12 SWSS were 47.4~94.0% (average 78.9%), in which the removal rates at the atmospheric storage are also included. Atmospheric storage and aeration can be used to reduce radon concentration in SWSS groundwater. For more efficient use of radon reduction, further studies are necessary to assess the radon removal rate considering variation conditions of radon concentration in groundwater, size and forms of water tank, change in groundwater usage rate, aeration capacity and ventilation facilities.

Development of Guidelines for Physical Security Systems of Small-scale Water Supplies (소규모수도시설의 보안시설 설치지침 개발)

  • Kim, Youngil;Yi, Sangjin;Lee, Doojin;Lee, Wontae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.723-730
    • /
    • 2013
  • Due to the event of hazardous chemical injection into a water storage tank in Hongseong, Chungcheongnam-do in 2012, the Korean Ministry of Environment has revised the enforcement rules of the Water Supply and Waterworks Installation Act to install surveillance equipments such as closed-circuit television(CCTV). However, the enforcement rules still do not provide concrete provision for installation of physical security equipments. Thus we studied vulnerability of small-scale water supplies in Korea and developed guidelines for the physical security system of the facilities. The guidelines include selection and recommendation of the physical security approaches and measures to detect, delay and response to the presence of an intruder in small-scale water supplies. The security features include protection utilities(e.g., fencing and fence topping), exterior intrusion detectors and alarms, locks and padlocks, surveillance utilities(e.g., CCTV), and others.

Fluoride and nitrate removal by electro-coagulation for decentralized water treatment plants (전기응집을 이용한 소규모 수도시설의 불소 및 질산성질소 이온의 제거)

  • Han, Song-Hee;Chang, In-Soung;Back, Soun-Ok;Joung, Seun-Young;Lee, Cheol-Ku
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.115-116
    • /
    • 2010
  • 광역상수도의 경우 수자원공사 및 지방상수도 사업자들에 의해 전문적으로 수질을 관리하고 음용수를 보급하고 있으나 소규모 수도시설의 경우 전문능력을 갖춘 관리자가 아닌 마을의 대표자가 맡아 관리함에 따라 안정성 및 유지관리의 어려움이 자주 제기되고 있다.[1] 또한 소규모 수도시설의 경우 취수원으로 지하수나 계곡수를 이용하여 여과나 염소소독을 거쳐 음용수로 이용함에 따라 중금속 및 무기이온 등 각종 오염물질이 효과적으로 제거되지 않아 이를 사용하는 주민들이 불편함을 겪고 있는 실정이다. 환경부의 법정 수질 검사에 따르면 부적합 판정을 받은 곳의 대부분은 마을상수도와 소규모 급수시설인 것으로 나타났으며 초과 항목으로는 무기이온 중 특히 불소와 질산성질소 인 것으로 나타났다.[2] 이러한 문제점을 해결하고자 기존의 고도 정수처리 시설인 막여과, 오존처리, 활성탄 흡착 공정 등을[3-5] 적용하고 있으나 소규모 수도시설에 적용하기에는 유지관리, 규모, 경제적 측면 등 여러 한계점을 지니고 있다. 따라서 본 연구에서는 이러한 문제점을 해결하기 위한 방안으로 전기응집기술을 이용하여 음용수 수질기준을 초과하는 무기이온 중 불소와 질산성 질소를 제거하고자 하였다. 전기응집기술은 제거효율이 높고, 운전이 용이하며 부가적인 화학약품의 첨가가 불필요하다.[6,7] 또한 기존의 고도정수처리 기술에 비해 전기응집 공정은 처리효율과 경제적인 측면 모두를 만족시키고 있어 소규모 수도시설의 불소와 질산성질소를 효과적으로 제거할 수 있는 방안으로 판단된다. 본 연구에 사용된 실험장치는 직류전원공급장치 (DC power supply), 반응조, 전극으로 구성되어 있다. 직류전원공급장치는 최대전압 30 Volt, 최대 전류 30 Amper 까지 조절 가능하였으며 반응조의 크기는 14.5cm(w) ${\times}$ 9cm(L) ${\times}$ 22cm(H) 이고 실용적 1.5L이다. 반응조의 상부에는 전극이 고정될 수 있도록 0.5cm 간격의 홈을 만들어 제작 하였다. 전극은 가용성 전극인 알루미늄 (Al), 스테인레스스틸(SUS304)를 이용하였다. 이를 통해 전류밀도, 전극간격 등의 변수를 두어 최적의 전기응집 운전 조건을 파악하였으며 이는 소규모 수도시설의 수질개선 향상에 도움이 될 수 있을 것으로 판단된다.

  • PDF

Damage of Waterworks Facilities on the Iwate-Miyagi Nairiku Earthquake Disaster in 2008 (2008년 이와테.미야기 내륙지진에 의한 상수도 피해와 제언)

  • Han, Youn-Hee;Ishibashi, Yoshinobu;Katou, Nao;Lee, Sang-Hoon
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.78.2-78.2
    • /
    • 2010
  • 2008년 6월 14일, 일본 이와테(암수(岩手)) 미야기(궁성(宮城)) 내륙 지진이 발생하였다. 평야지역에서의 피해는 경미하였지만, 산간지역은 괴멸적인 피해를 입은 것이 가장 큰 특정이다. 특히, 산간지역의 간이수도 등, 소규모 수도 시설의 지하수원이 고갈되고 정수시설의 경사면이 붕괴되는 등의 피해를 입었다. 또, 지진발생 후, 원수의 높은 탁도와 색도가 시간이 경과한 시점에서도 낮아지거나 없어지지 않았던 곳이 많았다. 이번 연구보고에서는, 간이수도 등의 피해와 상호지원 체제의 상황을 보고함과 동시에 소규모 수도시설의 지진 재해에 대한 제언을 제시하고자 하였다.

  • PDF

Cognition on Quality and Cost of Small Drinking Water Plants in Gyungbuk Region (경북지역 소규모수도시설 이용자의 수질.비용에 대한 인식)

  • Kang, Mee-A;Yang, Myeong-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.675-682
    • /
    • 2010
  • Groundwater is an essential drinking water source in Gyungbuk, South Korea. The primary source of nitrate in groundwater is from nitrogen fertilizers. Efficient management of a small drinking water plant requires a good understanding of its status such as the objective and the cognition of users. The objective of this study is to understand user situation and produce useful user-friendly policy based on user cognition. Most people who participated in this study, should take their groundwater from a good quality source. Even though they would like to have a good facility for getting safe water, they were reluctant to do it due to the cost used. It means that people who drink groundwater have no idea that health safety is affected by groundwater quality. The volume used depended upon personal activities such as agriculture and stockbreeding. We can easily find groundwater with nitrate that exceeds drinking water standards. Therefore, we have to carry out groundwater management with two categories ; 1) drinking water only and 2) others according to objectives in small drinking water systems.

Establishment of monitoring system and droughts response plan between uppermost stream and intake station (상류부 하천-취수원 연계 모니터링 및 가뭄 대응방안 구축)

  • Shin, Jieun;Kim, Jitae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.344-344
    • /
    • 2021
  • 세계적으로 기후변화 현상으로 인해 극심한 이상 가뭄이 빈번하게 발생하고 있다. 물 공급 소외지역의 경우 가뭄으로 인해 주민들이 불편을 겪고 있으며, 특히 마을상수도 및 소규모수도시설에 의존하는 최상류부 유역의 취수원은 상대적으로 가뭄에 취약하다. 본 연구의 대상 지역은 강원도 춘천시 물로천의 제1지류 유역으로 주민들이 하천 계곡수를 생활용수의 주 공급원으로 사용하고 있다. 해당지역은 갈수기에 생활용수 부족 문제를 겪고 있는 지역으로 가뭄 대응을 위한 구조적 대책으로 다단식 Sand댐을 설치할 예정이다. 현장조사 결과 물로천의 물은 취수조로 일부 유입되며, 자갈 등을 이용하여 부유물 등이 필터링되어 물탱크로 흘러내리며 중력에 의해 각 가정으로 자연 유하하는 것으로 나타났다. 본 연구에서는 대상지역의 하천, 취수조, 물탱크 3개 지점에 압력식 자동 수위 관측기를 설치하였으며, 2시간 간격의 수위를 측정할 수 있도록 설정하여 매달 유속 측정을 통해 수위-유량 관계 곡선식을 바탕으로 유량을 산정하였다. 도출된 일별 유량 자료와 SWAT 모형의 매개변수 검·보정한 후 이를 장기간으로 확장 적용하여 약 10년간의 장기 유출량을 산정하였다. 일별 장기 유출량 자료를 통해 평균 유량 감수곡선과 감수곡선식을 도출하였고, 무강우에 따른 최대 공급가능일수를 산정하였다. 본 연구에서는 하천-취수원 연계 모니터링 및 하천 유량에 따른 공급가능일수 등을 제시하여 가뭄 취약지역의 주민 불편을 최소화하고 가뭄에 대응할 수 있을 것으로 판단된다. 최종적으로 추후 Sand댐 건설 전후 비교 자료로 사용될 수 있으며, 소규모수도시설의 가뭄 관리를 위한 모니터링 체계 및 대응 방안을 구축하였다.

  • PDF

Fluoride and nitrate removal in small water treatment plants using electro-coagulation (전기응집을 이용한 소규모 수도시설의 질산성질소와 불소이온 제거)

  • Han, Song-Hee;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.767-775
    • /
    • 2011
  • In this study we verified if the electro-coagulation process can treat properly the nitrate and fluoride that are not removed well in the conventional small water treatment plants which usually employ chlorination and filtration only. As we gave a change of electrode material and gap-distance between electrodes, removal efficiency of the nitrate and fluoride was determined by electro-coagulation process which were equipped with aluminum and stainless steel (SUS304) electrodes. In addition, electrode durability was investigated by determination of electrodes mass change during the repetitive experiments. Removal efficiency was great when aluminum was used as an anode material. Nitrate removals increased as electric density and number of electrodes increased, but fluoride removal was less sensitive to both parameters than nitrate. After 10 minutes of contact time with the current density from $1{\times}10^{-3}$ to $3{\times}10^{-3}A/cm^{2}$, nitrate and fluoride concentration ranged from 9.2 to 1.2mg/L and from 0.02 to 0.01mg/L, which satisfied the regulation limits. Regardless of the repeating number of experiments, removal efficiency of both ions were almost similar and the change of electrode mass ranged within ${\pm}$0.5%, indicating that the loss of the electrode mass is not so much great under the limited circumstances.

한외여과막을 이용한 소규모정수처리시스템 -간이상수도용 막여과장치를 중심으로-

  • 신성철;배동목;김정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.146-149
    • /
    • 1998
  • 우리 나라는 1994년 말 현재 654개소에 28,434개소의 수도사업체가 있으며, 이중 간이상수도는 26,363개소로 총 93%를 차지하고 있다. 간이상수도와 같은 소규모 수도사업체에서는 재정적인 기반이 취약하며, 기술자 등이 인재확보가 어려운 형편이다. 이에 따라 대부분의 경우 수도시설의 일상적인 유지관리에 많은 불편이 따르고 있을 뿐만 아니라 적정 수질을 확보하기가 곤란한 실정이다. 간이상수도에서 수질이 좋은 물을 효율적으로 공급하기 위해서는 기존의 정수처리 시스템으로는 어려운 형편이다. 즉, 우리 나라 간이상수도의 정수처리과정은 소독을 기본으로 하여 응집침전, 급속모래여과, 등의 고액분리조작을 주체로 하고 있어 각 과정에 대한 유지관리에 많은 노력이 필요하다. 이에 따라 간이상수도에서는 보다 효율적으로 수질관리가 이루어질 수 있는 장치 및 시스템의 개발이 절실하다.

  • PDF

A Study on the Establishment of Water Supply and Demand Monitoring System and Drought Response Plan of Small-scale Water Facilities (소규모수도시설의 공급량-수요량 모니터링 체계 구축 및 가뭄 대응 방안 연구)

  • Choi, Jung-Ryel;Chung, Il-Moon;Jo, Hyun-Jae
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.469-481
    • /
    • 2019
  • In addition to structural stabilization measures such as the construction of Sand Dam, non-structural management measures such as reasonable water demand and supply volume management are needed to prevent limited water supply damage due to drought. In this study, water supply-demand monitoring system was established for drought response in Seosang-ri basin in Chuncheon, the main source of domestic water for small water facilities. The flow rate of the stream was measured for monitoring the supply volume, and the daily flow rate was calculated by using it to calibrate the parameters of the SWAT (Soil and Water Assessment Tool). To monitor demand, the daily usage was calculated by measuring the change in the water level of the water tank. The relationship between the finally calculated daily supply and demand amount was analyzed to identify the shortage of water.