• Title/Summary/Keyword: 세포배양장치

Search Result 45, Processing Time 0.03 seconds

Design of an Actuator Using Electro-active Polymer (EAP) Actuator with Composite Electrodes (복합재료 전극을 가진 전기활성고분자 구동기의 설계)

  • Kim, Dong-Uk;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.32 no.5
    • /
    • pp.211-215
    • /
    • 2019
  • The cell culture process under in vitro condition is much different from the actual human body environment. Therefore, in order to precisely simulate the human body environment, a dynamic cell culture device capable of delivering mechanical stimulation to cells is essential. However, conventional dynamic cell culture devices require relatively complicated devices such as tubes, pumps, and motors, and the mechanical stimuli delivered is also simple. In this study, an electro-active polymer actuator as a driving component is introduced to design simply driven dynamic cell culture device without complicated components. The device is capable of delivering relatively complex mechanical stimuli to the cells.

Culture Cells Apparatus for the Mobile Phone EMF Effects (배양세포에 대한 휴대폰 전자파 영향 연구를 위한 장치 개발)

  • 손태호;장성근
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.200-202
    • /
    • 2003
  • 배양세포에 휴대폰 전자파를 조사시켜 전자파의 영향을 연구할 수 있는 장치를 개발 제작하였다. 이 장치는 궁극적으로 이동통신용 전자파의 인체영향 평가를 위한 기초장비이며, 무선통신 산업화에 도움을 주고자 함을 목적으로 하고있다. 국내 CDMA 통화주파수인 835㎒를 발진한 신호는 세포의 종류와 인가할 세포의 SAR 레벨에 따라 다르게 전력 증폭된다. 증폭된 전자파는 CO₂ incubator 내에 설치된 TEM 균일 전자파 조사장치에 인가되고 그 안에 위치하는 petri dish내 배양세포에 균일하게 조사되도록 설계하였다. 전자파 균일 조사장치 내 전자계를 해석하고 세포의 전기적 특성에 따른 입력전력과 SAR의 관계를 구하였다.

  • PDF

Analysis of current density distribution and in vitro exposure system for ELF exposed cell experiments (ELF 전자파 피폭 세포실험을 위한 배양기의 전류밀도 분포해석 및 Invitro 노출장치 설계)

  • 김대근;정재승;안재목
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.297-301
    • /
    • 2000
  • ELF 전자파의 생물학적인 영향 평가를 위한 in vitro 세포 실험에서 노출장치의 설계는 코일내피 유도기전력(E)과 전류밀도(J) 해석과 함께 이루어져야 한다. 균일 자기장 속에서 세포를 배양할 경우애도 배양기내의 전도성 매질로 인해 균일한 E와 J가 분포하지 않는다. 따라서 균일한 ELF 자기장 노출장치로부터 발생되는 샘플 매질 내에서의 E나 J를 정확히 예측하는 것은 in vitro 세포실험의 성공여부를 가늠 할 정도로 매우 중요한 정보가 된다. 이에 본 논문에서는 in vitro 실험에 적합한 ELF in vitro 노출 장치를 설계하고 노출 장치에 대한 전자기학적 평가를 수행하였다. 코일 내에서 샘플 매질의 유무와 샘플 내에서도 세포가 놓여질 임의의 위치에 따라 E와 J를 예측하고 검증을 위한 측정과 시뮬레이션을 시도하였다. 노출장치는 헬름 홀쯔 코일로 제작되었고 자기장의 세기는 1-2OG 범위 내에서 가변이 가능하다. 또한 코일내의 자기장의 분포가 균일(uniform), 비균일(nonuniform)만 두 가지모드를 각각 제작하여 보았다.

  • PDF

High Density Culture of Hybridima Using Cell sedimentation System (세포 침전장치를 이용한 하아브리도마 세포의 고농도 배양)

  • 최대부;조보연
    • KSBB Journal
    • /
    • v.4 no.2
    • /
    • pp.143-149
    • /
    • 1989
  • A cell sedimentaion system was designed and employed for the high culture of hydridoma. An upward divering cell settler allowed a good sedimentation of hybridoma but the accumulation of cell mass on the settler's wall side was a potential prolem. Although a cyinderical cell settler was useful to solve this problem, this device was employable only at low dilytion rate. A modified cell settler could support the high density culture of hybridoma at a concentration of $5{\times}10^6$ cell/ ml during 1 week, producting 380mg of monclonal antibody.

  • PDF

Analysis of Current Density Distribution and In Vitro Exposur System fot ELF Exposed Cell Experiments (ELF 전자파 피폭 세포실험을 위한 배양기의 전류밀도 분포 해석 및 In Vitro 노출장치 설계)

  • 김대근;정재승;안재목
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.84-91
    • /
    • 2001
  • In in vitro cell experiments for the biological assessment of electromagnetic (EM) field, exposure system (ES) must be analyzed in terms of current density (J) and induced electric field intensity (E). Although in uniform B field, E and J in the sample medium are not distributed uniformly because of conductivity in sample dish. Thus, the precise estimation for E and J induced by uniform ELF within sample media is very important keys for successful in in vitro experiments. In this paper, we designed in vitro ELF ES with electromagnetic analysis using MATLAB simulator. Then we calculated from the measured B field to verify induced E & J distribution for random locations of cells within media in two cases of samples existence or not. ES with B field ranging from 0 to 20G consists of Helmholz coil and current generator based on the microprocessor. Also, we developed ELFES for each B field generation as uniform and non-uniform modes.

  • PDF

In Vitro Culture Following Purfication of Mouse Spermatogenic Cells (생쥐 정자세포의 분리와 체외 배양에 관한 연구)

  • 김묘경;김진회;이상민;정/하해숙;이훈택;정길생
    • Korean Journal of Animal Reproduction
    • /
    • v.20 no.1
    • /
    • pp.43-52
    • /
    • 1996
  • This study was carried out to establish the in vitro short-term culture system of developing male germ cells by purifing germ cells of various stages. The decapulated testicular cells were incubated with collagenase (lmg/ml) and try psin (2.5mg/ml) in HBSS. After separating male germ cell, the separated germ cells were stained with heamatoxylin/eosin and determined developing stages under light microscopy. The purity of pachtene spermatocytes a and round spermatid were 85%, respectively. Yield of total male germ cells was highly variable between individuals, with a mean value of 3.5 to 4.5 ${\times}$ 10$^7$ cells/testis. Viability of the cell was over 97% after separation. In DMEM medium, the optimal cell number for culture is approximately 1 x 10$^5$ cells/dish, but low cell den-sities than 1 ${\times}$ 10$^5$ cell/dish showed a decreased cell viability. Furthermore, about :36.8% of pac-hytene cells was successfully cultured for 6 days and some of cells were developed to secondary spermatids and round spermatids. Therefore, our data suggested that this culture conditions will be utilize as a feasible tools to produce tran-sgenic livestock using techniques such as intrac-ytoplasmic injection and cell fusion.

  • PDF

전자계산기 자동제어에 의한 효모 발효의 포도당 유가배양

  • 박홍우;박두홍;박종문;조규헌;최차용
    • Proceedings of the Korean Society for Applied Microbiology Conference
    • /
    • 1979.10a
    • /
    • pp.245.1-245
    • /
    • 1979
  • PDP 전자 계산기를 발효소에 연결하여 자동 제어하의 효모 유가 배양을 수행하였다. 필요한 부대 장치들을 만들어 성공적으로 사용하고 feed-back자동 제어를 수행할 수 있게 발효도중 임의의 시간에 발효 조건을 모니터하도록 하였다. 연속 세포 농도 측정을 위한 플로우ㆍ셀을 자체 제작하여 사용함과 동시에 기포 제거를 따로 할 필요가 없도록 하였다. 측정 시그날을 위한 증푹기도 자체 제작하였던 바 우수한 성능을 보여 주었다. 이 경험으로 다른 모든 측정 장치의 개발과 전자 계산기에의 연결에 값진 경험을 주었다.

  • PDF

Hollow Fiber Membrane Bioreactor (실관 막 생물 반응기)

  • Kim, In Ho
    • Applied Chemistry for Engineering
    • /
    • v.5 no.6
    • /
    • pp.911-916
    • /
    • 1994
  • Hollow fiber membrane has been successfully developed as an artificial kidney device in the 1970's. In the early 1970's animal cells were introduced into a hollow fiber membrane cartridge and well propagated in the cartridge. Since then, hollow fiber membrane was utilized as a bioreactor in order to immobilize enzymes as well as to culture microbial cells and plant cells. In this review, the present status and the prospect of hollow fiber membrane bioreactor are investigated in view of cell density and product productivity.

  • PDF

포토레지스트를 이용한 선택적 세포배양기술 연구

  • Kim, Min-Su;Jo, Won-Ju;Choe, Jeong-Yeon;Im, Jeong-Ok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.247-247
    • /
    • 2010
  • 전계효과 트랜지스터를 이용한 바이오센서는 하나의 칩 위에 많은 센서 소자를 집적할 수 있으므로, 같은 종류의 센서를 다수 배열함으로써 다차원화할 수 있고, 다른 종류의 센서를 여러개 배열함으로써 다기능화할 수 있다. 또한 지능회로와 함께 집적하여 지능화하거나, 관련회로 및 장치들을 함께 집적함으로써 시스템화할 수 있기 때문에 최첨단 센서로 각광을 받고 있다. 그러나, 전계효과 트랜지스터를 이용한 바이오센서는 게이트 영역에 생체 분자를 고정시키는 것이 어렵고, 고정되더라도 생체 분자의 양이 미량이어서 재현성이 떨어지며, 생체 분자가 발생시키는 시그널이 적어 전류 세기 변화에 대한 검출감도가 저하되는 문제점이 있다. 본 연구에서는 반도체 리소그래피 공정을 이용하여 생체 분자를 물리 화학적 처리 없이 게이트 영역에 집중적으로 고정시킬 수 있는 기술에 대해 연구하였다. 산화막이 증착된 기판 위에 포토레지스트를 도포한 뒤 리소그래피공정을 이용하여 패터닝 하였으며 기판 위에 human embryonic kidney(HEK)-293 세포를 배양하였다. 연구결과, 친수성인 포토레지스트보다 소수성인 산화막 영역에 다수의 세포가 선택적으로 집중 배양됨을 확인하였다. 따라서 본 연구결과를 바이오센서에 적용할 경우 센서의 검출감도를 향상시킬 수 있을 것으로 기대된다.

  • PDF

Development and Application of a Novel Mammalian Cell Culture System for the Biocompatibility and Toxicity of Polymer Films and Metal Plate Biomaterials (고분자필름과 금속막 의료소재에 대한 생체적합성 및 독성 평가를 위한 새로운 세포배양시스템의 개발 및 적용)

  • Kwak, Moon Hwa;Yun, Woo Bin;Kim, Ji Eun;Sung, Ji Eun;Lee, Hyun Ah;Seo, Eun Ji;Nam, Gug Il;Jung, Young Jin;Hwang, Dae Youn
    • Journal of Life Science
    • /
    • v.26 no.6
    • /
    • pp.633-639
    • /
    • 2016
  • Biomaterials including polymer, metal, ceramic, and composite have been widely applied for medical uses as medical fibers, artificial blood vessels, artificial joints, implants, soft tissue, and plastic surgery materials owing to their physicochemical properties. However, the biocompatibility and toxicity for film- and plate-form biomaterials is difficult to measure in mammalian cells because there is no appropriate incubation system. To solve these problems, we developed a novel mammalian cell culture system consisting of a silicone ring, top panel, and bottom panel and we applied two polymer films (PF) and one metal plate (MP). This system was based on the principal of sandwiching a test sample between the top panel and the bottom panel. Following the assembly of the culture system, SK-MEL-2 cells were seeded onto Styela Clava Tunic (SCT)-PF, NaHCO3-added SCT (SCTN)-PF, and magnesium MP (MMP) and incubated at 37℃ for 24 hr and 48 hr. An MTT assay revealed that cell viability was maintained at a normal level in the SCT-PF culture group at 24 or 48 hr, although it rapidly decreased in the SCTN-PF culture group at 48 hr. Furthermore, the cell viability in the MMP culture group was very similar to that of the control group after incubation for 24 hr and 48 hr. Together, these results suggest the sandwich-type mammalian culture system developed here has the potential for the evaluation of the biocompatibility and toxicity of cells against PF- and MP-form biomaterials.