• Title/Summary/Keyword: 세트업 오차

Search Result 2, Processing Time 0.016 seconds

Location Error of the Dens in a Two-Dimensional Set-up Verification During Head and Neck Radiotherapy (뇌.두경부 방사선치료 시 전자조사문영상장치를 이용한 세트업 오차 확인에서 제2경추 치상돌기 위치의 임상적 의의)

  • Kim, Dong-Hyun;Kim, Won-Taek;Ki, Yong-Gan;Nam, Ji-Ho;Lee, Mi-Ran;Jeon, Ho-Sang;Park, Dal;Kim, Dong-Won
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.107-114
    • /
    • 2011
  • Purpose: To assess the degree and clinical impact of location error of the dens on the X-axis during radiotherapy to brain and head and neck tumors. Materials and Methods: Twenty-one patients with brain tumors or head and neck tumors who received three-dimensional conformal radiation therapy or intensity-modulated radiation therapy from January 2009 to June 2010 were included in this study. In comparison two-dimensional verification portal images with initial simulation images, location error of the nasal septum and the dens on the X-axis was measured. The effect of set-up errors of the dens was simulated in the planning system and analyzed with physical dose parameters. Results: A total of 402 portal images were reviewed. The mean location error at the nasal septum was 0.16 mm and at the dens was 0.33 mm (absolute value). Location errors of more than 3 mm were recorded in 43 cases (10.7%) at the nasal septum, compared to 133 cases (33.1%) at the dens. There was no case with a location error more than 5 mm at the nasal septum, compared to 11 cases (2.7%) at the dens. In a dosimetric simulation, a location error more than 5 mm at the dens could induce a reduction in the clinical target volume 1 coverage (V95: 100%${\rightarrow}$87.2%) and overdosing to a critical normal organ (Spinal cord V45: <0.1%${\rightarrow}$12.6%). Conclusion: In both brain and head and neck radiotherapy, a relatively larger set-up error was detected at the dens than the nasal septum when using an electronic portal imaging device. Consideration of the location error of the dens is necessary at the time of the precise radiation beam delivery in two-dimensional verification systems.

NIRS Calibration Equation Development and Validation for Total Nitrogen Contents Field Analysis in Fresh Rice Leaves (벼 생엽의 질소함량 현장분석을 위한 NIRS 검량식 개발 및 검증)

  • Song, Young-Eun;Lee, Deok-Ryeol;Cho, Seong-Hyun;Lee, Ki-Kwon;Jeong, Jong-Seong;Gwon, Yeong-Rip;Cho, Kyu Chae
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.58 no.3
    • /
    • pp.301-307
    • /
    • 2013
  • This study was evaluated high end research grade Near Infrared Reflectance Spectrophotometer (NIRS) to field grade multiple Near Infrared Reflectance Spectrophotometer (NIRS) for rapid analysis at fresh rice leaf at sight with 238 samples of fresh rice leaf during year 2012, collected Jeollabuk-do for evaluate accuracy and precision between instruments. Firstly collected and build database high end research grade NIRS using with 400 nm ~ 2500 nm during from year 2003 to year 2009, seven years collected fresh rice leaf database then trim and fit to field grade NIRS with 1200 nm ~ 2400 nm then build and create calibration, transfer calibration with special transfer algorithm. The result between instruments was 0.005% differences, rapidly analysis for chemical constituents, Total nitrogen in fresh rice leaf within 5 minutes at sight and the result equivalent with laboratory data. Nevertheless last during more than 8 years collected samples for build calibration was organic samples that make differentiate by local or yearly bases etc. This strongly suggest population evaluation technique needed and constantly update calibration and maintenance calibration to proper handling database accumulation and spread out by knowledgable control laboratory analysis and reflect calibration update such as powerful control center needed for long lasting usage of fresh rice leaf analysis with NIRS at sight. Especially the agriculture products such as rice will continuously changes that made easily find out the changes and update routinely, if not near future NIRS was worthless due to those changes. Many research related NIRS was shortly study not long term study that made not well using NIRS, so the system needed check simple and instantly using with local language supported signal methods global distance (GD) and neighbour distance (ND) algorithm. Finally the multiple popular field grades instruments should be the same results not only between research grade instruments but also between multiple field grade instruments that needed easily transfer calibration and maintenance between instruments via internet networking techniques.