• Title/Summary/Keyword: 세척일

Search Result 2,183, Processing Time 0.028 seconds

Determination of Soil Washing Condition for Light Hydrocarbon Contaminated Soils (Light Hydrocarbon에 오염된 토양의 용매추출조건에 관한 연구)

  • Hwang, Keon-Joong;Atalay, Asmare
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.82-90
    • /
    • 1997
  • This study was conducted to establish an ideal condition for obtaining maximum extraction efficiencies using an array of soil types and under a wide variety of conditions. Nine characteristic compounds were studied: benzene, toluene, ethylbenzene, o-xylene, m-xylene, p-xylene, n-propylbenzene, 1,2,4-trimethylbenzene, and n-butylbenzene which were found in gasoline. Increasing the moisture content resulted in decreased recovery, and recovery of hydrocarbons from wet soils was significantly lower than from dry soils. For the batch extraction process, 4 hours of extraction time was sufficient to give optimum recovery of the contaminants. With methanol as an extraction solvent, maximum recovery time appeared to be reached quicker for BTEX components than with 2-propanol. The 2 to 1 ratio of solvent/soil was chosen as a compromise to provide for the indicated minimum solvent use and high extraction efficiency. The 0.4 mg/g soil contamination was adequate to show quantitative recovery. The percent recovery of BTEX was concentration dependent more than the semivolatile compounds. Methanol and 2-propanol consistently gave higher efficiency than water. Methanol was superior to 2-propanol in removing contaminants from silty clay loam soil. Using the most efficient extraction procedure, the average recovery of the light hydrocarbons from the three soils was 66 percent. Recoveries were also dependent on soil type, solvent type, extraction time, solvent amount, contaminant concentration, and compounds volatility. This study provided a useful screening technique for procedures that can be used to remediate soils contaminated with light hydrocarbons.

  • PDF

Infection control of dental implant hand drivers using ethanol solution (에탄올을 이용한 치과 임플란트 핸드 드라이버의 감염 관리에 대한 연구)

  • Yu, Song-Yi;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.158-167
    • /
    • 2020
  • Purpose: The purpose of this study was to study the effects of the utilization of ethanol solution in infection control of dental implant hand drivers, a common practice in dental prosthodontic clinics. Materials and Methods: Infection control methods were divided into two groups. One swabbed with 83% ethanol gauze and the other immersed in 83% ethanol solution for 30, 60, 90, 120, 150, 180 and 300 second intervals after inoculation of the dental implant hand drivers with Staphylococcus aureus. After measuring the number of colony forming units and analyzing the optical density, the effects of infection control in the experimental group were compared with the positive control group without infection control after inoculation with bacteria and the negative control group without inoculation with bacteria after sterilization. Results: The number of colony forming units and optical density analysis showed a statistically significant difference compared to the positive control. On the other hand, there was no statistically significant difference between the negative control and the group immersed in the 83% ethanol solution for more than 150 seconds. Conclusion: It is recommended to use the ethanol solution as a pre-cleaning process before sterilization, since the intermediate-level disinfection method using ethanol solution alone for the infection control of the dental implant hand driver cannot clinically secure the sterility.

Usefulness of Automated PCR Test for the Detection of Mycobacterium Tuberculosis in Fresh Biopsy Tissues (신선조직 검체에서 결핵균 검출을 위한 자동화 중합효소연쇄반응 검사의 유용성)

  • Choi, Woo Soon;Shin, So Young;Kim, Jong Ok;Kim, Myung Sook;Lee, Hye Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.54-59
    • /
    • 2006
  • Background: Although there have been several studies regarding the clinical value of an automated TB-PCR study using sputum, bronchial washing, and other body fluid samples for the detection of pulmonary tuberculosis, there are only a few reports on the use of fresh tissue samples. Materials and methods: The acid-fast bacilli stain(AFB), tuberculosis culture, automated TB-PCR study, and histopathology examination were performed in 42 fresh tissue samples. Results: Among the 42 cases, 18 cases were diagnosed with tuberculosis based on the clinical findings. Sixteen of the 18 cases were TB-PCR positive and of these 16 cases, only 2 cases were positive in the AFB stain or culture study. However, all 18 cases showed the histopathology findings of chronic granulomatous inflammation that was compatible with tuberculosis. Based on the clinical findings, the sensitivity, specificity, positive predictability, and negative predictability of the automated TB-PCR study were 88.9%, 100%, 100%, and 92.3% respectively. Conclusion: An automated TB-PCR assay is an important diagnostic tool for diagnosing tuberculosis in fresh tissue samples.

EVALUATION OF SODIUM DICHLOROISOCYANURATE AS A ROOT CANAL IRRIGATION SOLUTION;Cl- CONCENTRATION, pH, CYTOTOXICITY AND ANTIMICROBIAL EFFECT IN VITRO (이염화이소시아뉼산나트륨 제재의 근관세척액 사용 가능성 평가;염소이온농도, 세포독성, 항균성 및 pH)

  • Lee, Woo-Cheol;Kang, Bong-Sun;Kim, Cheol-Ho;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.425-430
    • /
    • 2003
  • The purpose of this study was to evaluate the clinical applications of the Sodium Dichloroisocyanurate effervescent tablet as a routine root canal irrigant by performing several in vitro tests such as $Cl^{-}$ content. cytotoxicity. antimicrobial effect as well as its pH level compared to the equivalent concentration of sodium hypochlorite solution. 1. Sodium Dichloroisocyanurate demonstrated lower level of $Cl^{-}$ concentration than each dilution of sodium hypochlorite solution. Both solution has increased level of $Cl^{-}$ as the concentration of each solution increased. There was no significant change of $Cl^{-}$ concentration in sodium hypochlorite as time goes by. However. $Cl^{-}$ concentration in Sodium Dichloroisocyanurate was increased. 2. The antimicrobial effects of both solutions were increased when their concentrations were increased. One day after dilution. antimicrobial effect of Sodium Dichloroisocyanurate was slightly higher than sodium hypochlorite. however. there was no difference in 1 week dilution solution. One month dilution solution of sodium hypochlorite still retain its activity. but antimicrobial effect of Sodium Dichloroisocyanurate was drastically decreased 1 month after dilution. 3. The cytotoxicity of Sodium Dichloroisocyanurate was rather higher than same concentration of sodium hypochlorite solution until 1 week after dilution. Then in 1 month. cytotoxicity of Sodium Dichloroisocyanurate was decreased than that of 1 week dilution solution. especially 4% Sodium Dichloroisocyanurate solution has almost no toxicity. However. 1% and 2% sodium hypochlorite solution has unchanged moderate degree of cytotoxicity after the dilution. Furthermore. 4% sodium hypochlorite solution showed high level of toxicity. 4. The pH level of Sodium Dichloroisocyanurate showed that the solution was weak acid (pH5). On the other hand. sodium hypochlorite was revealed as a strong alkaline solution (pH12). There was no change in pH following the dilution of each solution. As results. Sodium Dichloroisocyanurate solution fully satisfy the basic requirements as a root canal irrigation solution. However. we strongly recommend to use this solution clinically in low concentration and try to apply into the root canal within 1 week after dilution.

Manufacture and Characteristics of Concrete Sidewalk Blocks Using Photocatalyst Agent (광촉매제를 사용한 콘크리트 보도블록의 제조 및 특성)

  • Jung, Yong-Wook;Chang, Chun-Ho;Kim, Jong-Kyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.423-430
    • /
    • 2019
  • In this study, the flexural strength, absorption rate, methylene blue photo catalyst decomposition performance and anti-fouling performance were evaluated according to the photo catalyst mixing rate and block surface wash status by applying photo catalyst to the surface layer of concrete sidewalk block. The results showed that the flexural strength of the block that mixed photo catalyst only in the surface layer of the concrete block was 5.32MPa of the general block (SNW) of 5% photo catalyst, compared to 5.46MPa of the non-mixed concrete block of the reference concrete block. Surface washing block (SW) 5.26MPa, 10% photo catalyst general block (SNW) 5.26MPa, and 5.15MPa surface washing block (SW). It has been shown that the presence of surface washing and the mixing rate of photo catalyst in the concrete block have no effect on the flexural strength. Moreover, the photoreaction performance of concrete sidewalk blocks showed that the methylene blue removal rate of specimens with 5% TiO2 was 34.2%, the methylene blue removal rate of specimens with 10% TiO2 was 37.1%, and the removal rate of the methylene blue of specimens with 5% TiO2 was about 37.9% and 10% mixed specimens with TiO2 was about 37.6%.

Removal of Nitrogen Using by SOD Process in the Industrial Wastewater Containing Fluoride and Nitrogen from the Zirconium Aolly Tubing Production Factory of the Nuclear Industry (원자력산업 지르코늄합금 튜브 생산공장에서 배출되는 불소.질소 함유 폐수의 황산화탈질을 이용한 질소처리)

  • Cho, Nam-Chan;Moon, Jong-Han;Ku, Sang-Hyun;Noh, Jae-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.855-859
    • /
    • 2011
  • The main pollutants from zirconium alloy tubing manufacturing process in nuclear industry are nitrate ($NO_3-N$) and fluoride (F-)Nitric acid, and hydrofluoric acid is used for acid pickling. The process for the removal of nitrate and fluoride is composed of 1st chemical coagulation, SOD (Sulfur Oxidation Denitrification) process using sulfur-oxidizing denitrification, and 2nd chemical coagulation. The characteristic of the wastewater treatment is an application of SOD process. The SOD Process is highly received attention because it is significantly different from existing processes for sulfur denitrification. A JSC (JeonTech-Sulfur- Calcium) Pellet is unification of sulfur and alkalinity material. According to result of SOD process in wastewater treatment plant, the removal efficiency of T-N was over 91% and the average concentration of T-N from influent was 147.55 mg T-N/L and that from effluent was 12.72 mg T-N/L. Therefore, SOD process is a useful to remove nitrogen from inorganic industrial wastewater and a new development of microbial activator was shown to be stable for activation of autotrophic bacteria.

A Study on Persulfate Oxidation to Remove Chlorinated Solvents (TCE/PCE) (과황산(persulfate) 산화반응을 이용한 염소계 화합물(TCE, PCE) 분해에 관한 연구)

  • Song, Kyoung-Ho;Do, Si-Hyun;Lee, Hong-Kyun;Jo, Young-Hoon;Kong, Sung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.549-556
    • /
    • 2009
  • In situ chemical oxidations (ISCO) are technologies for destruction of many contaminants in soil and groundwater, and persulfate has been recently studied as an alternative ISCO oxidant. Trichloroethylene (TCE) and tetrachloroethylene (PCE) were chosen for target organic compounds. The objective of this study is to demonstrate the influence of initial pH (3, 6, 9, 12), oxidant concentrations (0.01, 0.05, 0.1, 0.3, 0.5 M), and contaminants concentrations (10, 30, 50, 70, 100 mg/L) on TCE/PCE degradation by persulfate oxidation. The maximum TCE/PCE degradation occurred at pH 3, and the removal efficiencies with this pH condition were 93.2 and 89.3%, respectively. The minimum TCE/PCE degradation occurred at pH 12, and the removal efficiencies were 55.0 and 31.2%, respectively. This indicated that degradation of TCE/PCE decreased with increasing the initial pH of solution. Degradation of TCE/PCE increased with increasing the concentration of persulfate and with decreasing the concentration of contaminants (TCE/PCE). The optimum conditions for TCE/PCE degradation were pH 3, 0.5 M of persulfate solution, and 10 mg/L of contaminant concentration. At these conditions, the first-order rate constants ($k_{obs}$) for TCE and PCE were 1.04 and 1.31 $h^{-1}$, respectively.

Uncertainty evaluation of the analysis of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in hair by GC-NCI-MS/MS (GC-NCI-MS/MS를 이용한 모발 중 대마 대사체 분석의 측정불확도 평가)

  • Kim, Jin-Young;Lee, Jae-Il;Cheong, Jae-Chul;Suh, Yong-Jun;In, Moon-Kyo
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • We described an estimation of measurement uncertainty in quantitative analysis of 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THC-COOH), the metabolite of ${\Delta}^9$-tetrahydrocannabinol, in hair samples by using the bead-assisted liquid-liquid extraction and gas chromatography-tandem mass spectrometric (GC-NCI-MS/MS) detection. Traceability of measurement was established through the use of reference materials, calibrated volumetric tubes, volume measuring devices, and measuring instruments. The analytical results were compared and the different contributions to the uncertainty were evaluated. Inter-day variation was performed by using statistical analysis of several indicative factors. Measurement uncertainty associated with the analyte in real forensic hair samples were estimated using QC data. The major factor of contribution to combined standard uncertainty was inter-day repeatability, while those associated with preparation of analytical standard and also sample of weight were insignificant considering the degree of contribution. Relative uncertainty of relative extended standard uncertainty divided into the measured concentration of the analyte was 17% in a hair sample. The uncertainty of result evaluation will be invaluable to improve quality of the analysis.

Studies on the browning inhibition of yam(Dioscorea aimadoimo) during hot air dehydration (단마(Dioscorea aimadoimo)의 열풍건조 시 갈변 억제 방안 연구)

  • Chung, Yong-Yul;Jeong, Woo-Sik;Chung, Shin-Kyo
    • Applied Biological Chemistry
    • /
    • v.39 no.5
    • /
    • pp.384-388
    • /
    • 1996
  • This research was conducted to investigate the effective methods for browning inhibition on yam (Dioscorea aimadeimo) during dehydration by physical and chemical pretreatments. Moisture, crude protein, crude fiber and N-free extract contents of yam were 81.17%, 1.43%, 0.29% and 15.81%, respectively. Yams were sliced to 0.5 cm thickness and placed to single and poly layer in plastic tray, and then changes of their weights were measured during air dehydration at $50^{\circ}C,\;65^{\circ}C,\;and\;80^{\circ}C$. The dehydration time reaching to optimum moisture level for the pulverization of the yam slices were 10, 6, 3 hours(single layered) and 12, 7, 5 hours(multi layered) at the respective temperature. To inhibit browning at $80^{\circ}C$ air dehydration, water and steam blanching, microwave treatment effects were investigated on yam slices for 30 sec. and 60 sec. Steam blanching for 30 sec. was comparatively effective to inhibit browning of yam slices. Yam slices were immersed in single and combined browning inhibitor solutions and evaluated for browing degree during dehydration by the values of Hunter L, a, b and ${\Delta}E$. The most effective pretreatment to inhibit browning of yam slices was immersion In the solution containing 500 ppm of citric acid and 1000 ppm of cysteine for 1 min.

  • PDF

A Study on Environmental Monitoring of Fluorouracil and Decontamination Reagents (Fluorouracil의 환경감시 및 제거약제에 관한 연구)

  • Lee, Su-Gil;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.4
    • /
    • pp.47-52
    • /
    • 2009
  • This study has been to examine the occupational exposure levels of Fluorouracil (5-FU) in a hospital and to investigate the most effective cleaning reagent for control. Fluorouracil is one of the cytotoxic drugs which are therapeutic agents used to treat cancer. The health practitioners working in the cytotoxic work room and oncology ward areas are exposed to adverse health risks like cytogenetic and DNA damage from cytotoxic drugs exposure by frequent skin contact from contaminated surfaces. Four kinds of cleaning reagents has been examined to degrade the 5-FU. It was found that 5-FU was only degraded soon after the reaction in 0.5%(w/v) NaClO solution. Therefore, 0.5%(w/v) NaClO solution has been chosen to decompose any residues on the contamination surfaces. A substantial level of contamination was found on the surfaces of cytotoxic work room and oncology ward areas. The contamination ranges of the surfaces in cytotoxic work room and oncology ward areas were from 2.0 to $13.8{\mu}g/m^2$ and 5.39 to $11.53{\mu}g/m^2$ respectively. Consequently, regulation of the occupational exposure limit, procedure of special cleaning, and the use of personal protective equipment are recommended during the manipulation and administration of the drugs to avoid skin contamination from cytotoxic drugs like 5-FU.