Statistical Analysis on the Structure of the Front Door in Apartment House (공동주택 세대 현관 방화문 구조에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.23-24
    • /
    • 2021
  • Since 2011, apartment houses account for about 41% of the fires in residential facilities for the past 10 years. Fire-resistant performance of fire doors is becoming more important to prevent the spread of fire in apartment houses. This research analyzed the structure of fire door through each 10 DB based on the quality inspection report of Continuous Acquisition & Life-cycle Support(CALS) from 2016 to 2020, which passed the fire performance test based on the laws and notices of domestic fire door. Therefore, based on the results of the analysis of DB in the future, we will conduct a study on structural improvement and addition for fireproof performance improvement of fire door.

  • PDF

Statistical Analysis on the Structure and Performance of the Front Door in Apartment Housing (공동주택 세대 현관 방화문 구조 및 성능에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.115-123
    • /
    • 2022
  • Statistics on the occurrence of fires in residential facilities over the past 10 years, show that approximately 40% are fires in apartment buildings. To prevent the spread of fire and support evacuation in apartment housing, the fire resistance performance and performance design of fire doors are becoming more important. This study established a database using 395 quality inspection reports from 2016 to 2020, which passed the fire performance test, and derived the fire door performance-influencing factors through an analysis of the structure (12 elements) of the fire door. As a result, the effect of core material, adhesive, hinge type, blowing agent, etc. was confirmed in 287 pass cases. On the other hand, it was confirmed that the occurrence of flames and crevices in the 108 cases of failure were the major failure factors in the fire door fire resistance test. Fire doors are composed of composite materials to prevent failure of fire resistance performance, and efficient design and quality control are required through standardization of components.

Economic and Evacuation Time Analysis of Horizontally-installed Indoor Emergency Exit (하향식 피난구의 경제성 및 피난 소요시간 분석)

  • Liu, Yue;Kim, Sun-Kuk;Kim, Ki-Hyuk;Lee, Dong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.4
    • /
    • pp.363-373
    • /
    • 2018
  • Evacuation facilities are installed so that people can evacuate high-rise apartment houses when it is impossible to escape fire through the front door. The households of apartment houses may escape the building in two ways, which will reduce loss of lives. This study examined the characteristics of two-way evacuation facilities, including a light-weight partition wall, shelter space at the balcony and horizontally-installed indoor emergency exit. Then, it proposed a horizontally-installed outdoor emergency exit that improved the problems of the examined facility types, and analyzed its economic-feasibility. When a horizontally-installed emergency exit instead of a traditional type to escape from fire is used, people may be more autonomous in deciding whether active evacuation is possible or not. Thus, the time required to evacuate the building with 4 different evacuation methods using the stairs and horizontally-installed emergency exit was simulated in consideration of the impact of evacuation methods that people choose on the time required for evacuation using pathfinder. Then, the simulation results were compared and analyzed. Any appropriate evacuation method to reduce the time required for evacuation was predicted, analyzed and decided. As a result of this study, it was analyzed that the high - rise apartment top - down type evacuation zone can shorten the total evacuation time compared to the staircase type.