• Title/Summary/Keyword: 세대내 벽체

Search Result 5, Processing Time 0.02 seconds

공동주택 경량벽체 내화성능기준 설정

  • An, Jae-Hong;Yeo, In-Hwan;Jo, Gyeong-Suk;Choe, Dong-Ho;Min, Byeong-Ryeol
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.214-215
    • /
    • 2013
  • 공동주택을 기둥식 구조에서 공간을 구획하는 비내력 벽체로 사용되는 경략벽체에 요구되어지는 다양한 성능조건 중 내화성능 기준을 등급으로 구분하여 제시하고자 한다. 공동주택 경량벽체를 세대간 벽과 세대내 벽으로 구분하여 각각의 내화성능 요구수준에 맞는 성능등급을 설정하였으며, 이를 내화실험을 통하여 성능을 확인하였다.

  • PDF

A Study on the Fire Resistance and Sound Insulation Performance of Apartment House Interior Finish Wall Lightweight Drywall (공동주택 세대내 경량벽체 내화 및 차음 성능기준 설정)

  • An, Jae-Hong;Yeo, In-Hwan;Kim, Kyoung-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.2
    • /
    • pp.143-149
    • /
    • 2014
  • Recently, the structure system for apartment buildings in Korea has been changing from wall to post-beam structure. This study examines the fire resistance and sound insulation of light-weight dried wall, a component of post-beam structure. For the fire resistance and sound insulation in Korea, the Compartment wall of apartment house in the case of building regulation has regulations specify the detailed requirement of fire compartment walls in apartment, but do not specify that of interior walls. This study proposes the fire resisting rate of the interior wall into three grades in which the highest grade requires fire resistance of 30 minutes and also proposes the requirement of sound insulation performance into three grades in which the lowest grade requires 35dB.

Survey of Sound Transmission Between Dwelling Rooms and Noise Reduction Methods in Apartment Houses (공동주택 세대에서의 소음전달 실태와 저감방안)

  • Oh, Young-In;Kim, Heung-Sik;Kim, Ha-Geun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.33-44
    • /
    • 1990
  • In this paper, it represents the design requirements to make apartment houses comfortable in acoustic environments and to keep a privacy between dwellers. The sound insulation performance between rooms were tested in the fields and the conditions to satisfy the design requirements were investigated. For that purpose, the sound insulation performance between living room and bed room were investigated and noise transmittance according to the difference of arrangement in rooms were tested. Several flush doors and light-weighted walls which have difference with each material and structure were tested to suggest the methods that improve the acoustic environments.

  • PDF

Shear Strength Reduction Ratio of Reinforced Concrete Shear Walls with Openings (개구부를 갖는 철근콘크리트 전단벽의 전단강도 저감률)

  • Bae, Baek-Il;Choi, Yun-Cheul;Choi, Chang-Sik;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.451-460
    • /
    • 2010
  • There are many types of remodeling, however, engineers and architectures preferred to merge two or more separate units to one very spacious unit. Performing this type of remodeling, in the case of wall dominant apartments, requires partial removal of structural wall causing a concern of structural integrity. However, there are insufficient studies about partial removal, that is, openings. Presently, ACI standard have no clear way to evaluate the effect of opening on the structural wall. AIJ has the provision about strength reduction factor '$\gamma$'. However, this reduction factor cannot exactly evaluate the reduction effect of openings because this factor '$\gamma$' was determined through the elastic analysis. Therefore, in this study, 2 structural wall specimens were tested and many test results from previous studies were collected. Using these data, this study performed statistical analysis about strength of structural wall which have the opening in wall panel. And this study performed parametric study verifying shear strength reducing effect by opening area. In the results of statistical study, previous reduction factor show very conservative results because this equation did not consider other factors, reinforcement ratio and aspect ratio of openings, which was affect the shear strength of shear walls. Therefore we performed parametric study based on the test data and suggest new equation for shear strength reduction factor '$\gamma$'.