Analysis of Passenger Refuge Model Using EXODUS Refuge Simulator: Case of the Daegu Underground Station Fire (EXODUS 피난시물레이터를 이용한 대구지하역사화재 승객피난모델분석)

  • Lee, Chang-Hyun;Jang, Yong-Jun;Park, Won-Hee;Kim, Dong-Hyeon
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1807-1813
    • /
    • 2007
  • The study aims at analyzing an underground station refuge model using EXODUS, one of the refuge simulation programs. The model for simulation is the Daegu Subway (Joongang-ro station). The details of the accident are referred to as the simulation condition the refuge time of traveling from the $3^{rd}$ basement platform to the $1^{st}$ basement is mainly calculated, with passengers numbering 1,000 including 329 at car 1079, 320 at car 1080, and 360 who are not on board. Reference data is used to set up the position of passengers. CFAST fire simulator is also used, and a fast curve among the $t^2$ growth curves, selected as fire growth scenario. The zone is divided into a total of 24 including 18 at the $3^{rd}$ basement platform and 6 at the $2^{nd}$ basement the $1^{st}$ basement is excluded in the fire simulation, however.

  • PDF

Evaluation of the Closed-type Sprinkler Head Activation Time (밀폐형 스프링클러 헤드의 동작시간 평가)

  • Moon-Hak, Jee;Sung-Yull, Hong
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2004
  • As a predominant active fire suppression method, closed-type sprinkler systems are used for the purpose of fire control and suppression at the nuclear power plants as well as the industrial facilities. It goes without saying that the proper selection of the system guarantees the adequate actuation of the thermal device. Consequently, the appropriate evaluation should be executed for the thermal behavior with the theoretical and empirical approach. For this purpose, the comparison of activation time for the fusible-link type sprinkler head with the simplified fire case and t-square fire growth case was evaluated. At this paper, the comparison output was presented with the tendency of thermal behavior. In addition, we issued some technical comments for the most appropriate equation in case of the estimation of the sprinkler head activation time. We also raised some idea that should be incorporated for the usage of the t-square equation for the realistic application in the field of the performance-base fire protection approach.

Fire Risk Index and Grade Evaluation of Combustible Materials by the New Chung's Equation-XII (새로운 Chung's equation-XII에 의한 연소성 물질의 화재위험성지수 및 등급 평가)

  • Yeong-Jin Chung;Eui Jin
    • Applied Chemistry for Engineering
    • /
    • v.34 no.4
    • /
    • pp.388-396
    • /
    • 2023
  • The evaluation of fire risk for combustible materials was carried out using Chung's equations-X, Chung's equations-XI, and Chung's equation-XII, which were newly established. The fire risk index-XII (FRI-XII) and fire risk rating (FRR) were calculated for specimens including camphor tree, cherry, rubber tree, and elm. The combustion characteristics were determined using a cone calorimeter according to ISO 5660-1. Chung's equations caculated the fire performance index-X (FPI-X) and fire growth index-X (FGI-X) values ranged from 89.34 to 1696.75 s2 /kW and from 0.0006 to 0.0107 kW/s2 , respectively. In addition, the fire performance index-XI (FPI-XI) and fire growth index-XI (FGI-XI) varied from 0.08 to 1.48 and from 0.67 to 11.89, respectively. The fire risk index-XII (FRI-XII), which is an indicator of fire risk, showed that camphor tree had a value of 148.63 (fire risk rating: G), indicating a very high fire risk. This suggests that combustible materials with a high concentration of volatile organic compounds have lower FPI-X and FPI-XI values, higher FGI-X and FGI-XI values, and consequently higher FRI-XII values, indicating an increased fire risk.

Rating of Fire Risk of Combustible Materials by the New Chung's Equation-IX (새로운 Chung's equation-IX에 의한 연소성 물질의 화재 위험성 등급 평가)

  • Yeong-Jin Chung;Eui Jin
    • Applied Chemistry for Engineering
    • /
    • v.34 no.2
    • /
    • pp.144-152
    • /
    • 2023
  • To evaluate the fire risk of combustible materials, Chung's equations VII, VIII, and IX were newly established. The fire risk index-IX (FRI-IX) and fire risk rating (FRR) were calculated. Ginkgo, dawn redwood, toona, lime, walnut, and polymethylmethacrylate (PMMA) were selected as test specimens. The combustion characteristics were evaluated using a cone calorimeter according to ISO 5660-1. After combustion, the fire performance index-VII (FPI-VII) of the specimens, varied between 15.15 and 182.53 s2/kW, as determined by Chung's equations, and the fire growth index-VII (FGI-VII) varied between 0.0023 and 0.0165 kW/s2. The fire performance index-VIII (FPI-VIII) based on PMMA varied between 0.29 and 3.45, and the fire growth index-VIII (FGI-VIII) varied between 2.88 and 20.63. The FRI-IX, which is the fire risk rating, showed dawn redwood has a very high fire risk, with FRI-IX values of 71.14 (fire risk rating: G). Therefore, wood with a large amount of volatile organic compounds and a low bulk density showed a high value of FRI-IX by lowering FPI-VII and FPI-VIII and increasing FGI-VII and FGI-VIII.

Heat Release Rate Measurements of Residential Combustibles Using Oxygen Consumption Method (산소소모법을 이용한 주택 가연물 발열량 측정)

  • Choi, Byung-Il;Han, Yong-Shik;Kim, Myung-Bae
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.104-107
    • /
    • 2008
  • Heat release rates of main combustibles in residence area were measured by a calorimeter using oxygen consumption method. It was found that the peak heat release rates of the combustibles were 1.0MW for a refrigerator, 0.8MW for a desk, 4.2MW for a wardrobe and 0.4MW for a bed. Especially, the refrigerator and wardrobe were found to be very hazardous because of their fast fire growth rate.

Vehicle Fire Extinguishing System (차량 소화시스템)

  • Kim, Gwan-hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.293-295
    • /
    • 2019
  • 우리나라의 경우 경제 성장을 거듭함으로서 국민 소득이 향상되고 자동차 산업이 발달함에 따라 자동차의 보유 대수도 급격히 증가하고 있지만 자동차 화재에 대한 인식은 매우 낮은 편이며, 차량화재는 다양한 원인들이 서로 독립되어 있는 것이 아니고 서로 연관되어서 화재 발생 요인으로 작용하고 있기 때문에 사고의 원인을 정확히 밝혀내기 어려운 경우가 많다. 자동차 소유자들의 자동차 화재에 대한 인식은 그다지 높지 않아 차내에 휴대용 소화기조차 비치하지 않고 있는 경우가 태반이고 이러한 실정을 가만하여 볼 때 자동차 자동 소화 시스템의 개발은 필수적이라고 할 수 있다. 본 논문에서는 버스 엔진실을 대상으로 하여 화재 발생 시 인명 피해를 막으면서 승객의 안전을 증대시키기 위하여 자동소화장치 제어기를 개발하고자 한다.

  • PDF

Calculation of Uncertainty in Measuring Heat Release Rate in Room Corner Test (룸코너 시험기의 발열량 측정에 대한 불확도 산정)

  • Noh, Kwang-Chul;Kim, Chi-Hoon;Lee, Seung-Chul;Lee, Duck-Hee
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.16-22
    • /
    • 2012
  • In fire test, accurate heat release rate measurements provide important information to define the fire safety characteristics of products. The calculation of heat release rate depends on the errors of measuring parameters in experimental set-up. In this study, the uncertainty factors of heat release rate in the room corner test facility, which is installed at Korea Railroad Research Institute, were analyzed. Through the fire testings for the KTX interior materials, the uncertainties of heat release rate were calculated. Results showed that uncertainty was high in the initial stage of fire test and gradually decreased with the growth of fire. The oxygen concentration was a major factor contributing to the combined relative standard uncertainty.