• Title/Summary/Keyword: 성능에 기초한 내진 설계

Search Result 113, Processing Time 0.022 seconds

Seismic Performance of Square RC Column Confined with Spirals (나선철근으로 횡구속된 정사각형 RC 기둥의 내진성능)

  • Ko, Seong Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.88-97
    • /
    • 2012
  • The objective of this research is to investigate the seismic performance and flexure-shear behavior of square reinforced concrete bridge piers with solid and hollow cross section. Test specimens were nonseismically designed with the aspect ratio 4.5 Two reinforced concrete columns were tested under constant axial load while subjected to lateral load reversals with increasing drift levels. Longitudinal steel ratio was 2.217 percent. The transverse reinforcement ratio As/($s{\cdot}h$), corresponding to 58 percent of the minimum lateral reinforcement required by Korean Bridge Design Specifications for seismic detailing, which represent existing columns not designed by the current seismic design specifications or designed by limited ductility concept. This study are to provide quantitative reference data for the limited ductility design concept and tendency for performance or damage assessment based on the performance levels such as cracking, yielding, collapse, etc. Failure behavior, ultimate displacement/drift ratio, displacement ductility, response modification factor, equivalent viscous damping ratio, residual deformation, effective stiffness, plastic hinge length, strain of reinforcements and nonlinear analysis are investigated and discussed in this paper.

Design of Viscoelastic Dampers to Meet Performance Objectives (성능목표를 달성하기 위한 점탄성 감쇠기의 설계)

  • 김진구;최현훈
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.2
    • /
    • pp.329-339
    • /
    • 2002
  • This research presents a systematic design procedure for supplemental viscoelastic dampers required to satisfy the given performance objectives using capacity spectrum method. To obtain required damper size, the amount of supplemental damping was computed from effective damping minus equivalent damping and inherent damping of structure. In the case of viscoelastic damper, iterative procedure is required because of the inherent stiffness of the damper. To verify the design method proposed in this study, parametric studies were performed for single degree of freedom systems with design variables. The method was also applied to a 10-story steel framed structure and the earthquake responses were obtained. According to time history analysis result the controlled displacements turned out to be close to the target displacement regardless of the design parameters.

Introduction and Necessity of concept of Demand for Performance-Based Design (성능기반설계에서의 요구성능의 개념 정의 및 필요성)

  • Lee, Byung-Goog;Park, Tae-Hyo;Lee, Sang-Youl
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.125-128
    • /
    • 2008
  • Studies for structure design has conducted in many research institutions. A basic concept of Performance-Based Design for structures was presented in seismic fields. Hereafter, Demand were defined to communicate owner's demand to designer by several research institution. Performance-Based Design is guaranteed by an accurate analysis from hazard affected to structures and from social, economical and environmental effects. It is essential to define Performance Level and Performance Objective to grasp accurate demand for structures. In this study, Performance Level and Performance Objective in ATC-40, FEMA-273 and Eurocode were defined to introduce Performance-Based Design.

  • PDF

Evaluation of Proper Supplemental Damping for a Multi-Story Steel Frame Using Capacity Spectrum Method (능력스펙트럼법을 이용한 다증 철골조 건물의 적정 감쇠기 선정)

  • 김진구;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.103-111
    • /
    • 2001
  • 본 연구에서는 능력스펙트럼법을 이용하여 성능목표를 만족하기 위하여 필요한 점성 감쇠기? 양을 간단하고 직접적인 방법으로 산정하는 방법에 관하여 연구하였다. 먼저 능력스펙트럼법을 이용하여 구조물의 비탄성 응답을 구하고 구조물의응답과 목표변위의 차이를 이용하여 필요한 유효감쇠비를 구하였다. 그리고 이러한 유효감쇠비를 이용하여 필요한 점성감쇠기의 양을 선정하였다. 본 연구에서 제안한 방법의 타당성을 검증하기 위해 10층의 철골조 건물에 세 가지 유형의 층지진하중을 가하고 제안된 절차에 따라 필요한 감쇠기의 양을 구하였다. 해석결과에 따르면 제안된 방법에 의하여 설계된 점성 감쇠기를 해석 모델에 설치하고 시간이력 해석을 수행한 결과 최대응답은 목표변위와 잘 일치함을 발견하였다.

  • PDF

Calculation of Optimum Damping Ratio of Viscous Dampers Using Capacity Spectrum Method (능력스펙트럼법을 이용한 점성 감쇠기의 적정 감쇠비 산정)

  • 김진구;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • 에너지 소산장치가 설치된 건무의 비선형 시간이력해석은 복잡하고 많은 시간이 소모된다. 본 연구에서는 비선형 정적해석법인 능력 스펙트럼을 이용하여 구조물의 주어긴 거동 한계를 만족할 수 있는 감쇠기의 양을 산정하는 방법에 관하여 연구하였다. 먼저 능력스펙트럼법을 이용하여 건물의 비선형 정적응답을 구하고 건물의 응답과 목표변위의 차이를 이용하여 유효감쇠비를 구하고 이러한 유효 감쇠비를 이용하여 필용한 점성 감쇠기의 양을 구하였다. 본 연구에서는 단자 유도계에서 건물의 주기, 요구되는 탄성강도에 대한 항복강도의 비, 항복 후 강성비 등을 변수로 하여 연구를 수행하였다. 제안된 방법에 따라 설계된 점성 감쇠기를 설치한 예제 구조물의 시간이력 해석에 의한 최대 응답은 설계의 초기단계에서 사용한 목표변위와 잘 일치하였다.

  • PDF

Equations for Estimating Energy Dissipation Capacity of Flexure-Dominated RC Members (철근콘크리트 휨재에 대한 에너지 소산능력 산정식의 개발)

  • 엄태성;박홍근
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.989-1000
    • /
    • 2002
  • As advanced earthquake design methods using nonlinear static analysis are developed, it is required to estimate precisely the cyclic behavior of reinforced concrete members that is characterized by strength, deformability, and energy dissipation. In a recent study, a simplified method which can estimate accurately the energy dissipation capacity of flexure-dominated RC members subjected to repeated cyclic load was developed. Based on the previously developed method, in the present study, simple equations that can be used for calculating the energy dissipation capacity were derived and verified by the comparison with experimental results. Through parametric study using the proposed equations, effects of axial load, reinforcement ratio, rebar arrangement, md ductility on the dissipated energy were investigated. The proposed equations can accurately estimate the energy dissipation capacity compared with the existing empirical equations, and therefore they will be useful for the nonlinear static analysis/design methods.

Seismic Performance and Flexural Over-strength of Hollow Circular RC Column with Longitudinal Steel Ratio 2.017% (축방향철근비 2.017%인 중공 원형 RC 기둥의 내진성능과 휨 초과강도)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Three small scale hollow circular reinforced concrete columns with aspect ratio 4.5 were tested under cyclic lateral load with constant axial load. Diameter of section is 400 mm, hollow diameter is 200 mm. The selected test variable is transverse steel ratio. Volumetric ratios of spirals of all the columns are 0.302~0.604% in the plastic hinge region. It corresponds to 45.9~91.8% of the minimum requirement of confining steel by Korean Bridge Design Specifications, which represent existing columns not designed by the current seismic design specifications or designed by seismic concept. The longitudinal steel ratio is 2.017%. The axial load ratio is 7%. This paper describes mainly crack behavior, load-displacement hysteresis loop, seismic performance such as equivalent damping ratio, residual displacement and effective stiffness and flexural over-strength of circular reinforced concrete bridge columns with respect to test variable. The regulation of flexural over-strength is adopted by Korea Bridge Design Specifications (Limited state design, 2012). The test results are compared with nominal strength, result of nonlinear moment-curvature analysis and the design specifications such as AASHTO LRFD and Korea Bridge Design Specifications(Limited state design).

Nonlinear Behavior of Seismic-Strengthened Domestic School Building (국내 기존 학교건축물의 내진보강 후 비선형 거동특성)

  • Ryu, Seung Hyun;Yun, Hyun Do;Kim, Sun Woo;Lee, Kang Seok;Kim, Yong Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.243-253
    • /
    • 2011
  • This paper describes an analytical study on seismic performance of domestic reinforced concrete (RC) school building not designed by seismic provision. The seismic index and the seismic performance of the building were evaluated through Japanese standard and Midas Gen, respectively. Seismic index (Is) of the RC school buildings in the X-direction is below 0.4. Based on the seismic index, for seismic-strengthening the building, infill shear wall or steel brace with a capacity of 1,300 kN was used. According to nonlinear static analysis results, the contribution of the seismic-strengthening to the shear resistance of the school building was measured to be greater than 30%. However, as expected, shear strength of school building strengthened with infill wall dropt rapidly after peak load and much narrower ductile behavior range was observed compared to steel brace strengthened building. Also, the building strengthened with steel brace showed 30% larger spectral displacement than that strengthened with infill shear wall. In nonlinear dynamic analysis, for the time history analysis, the maximum displacement showed tendency to decrease as amount of reinforcement increased, regardless of strengthening method. It was recommended that variable soil properties and earthquake record should be considered for improving seismic performance of buildings in seismic zone.

Results of Fatigue Test of Lead Rubber Bearing (지진격리장치(LRB)의 피로시험 결과)

  • 이민구;강형택;유환구
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.442-448
    • /
    • 2003
  • 최근 장대교량의 건설이 증가하고 지진에 대한 관심이 고조되면서 교략의 내진설계와 면진설계가 교량설계의 주요항목으로 자리잡게 되었다. 특히 최근 ILM교량과 같은 다경간 장대교의 경우 지진시 교량의 상부구조와 하부구조를 격리시켜 주기를 변화시키는 LRB를 이용한 면진설계가 주로 이루어지고 있다. 그러나 아직까지 국내에는 Mt5의 거동과 기본성능에 대한 실험데이터가 절대적으로 부족하며, 따라서 그 특성을 엄밀히 검증하지 못한 채 고속도로 및 국도상의 교량에 LRB를 다수 사용하고 있는 현실이다. 본 연구에서는 실교량에 사용될 LRB에 대하여 기본성능 중의 하나인 피로마모시험을 수행함으로써 온도하중과 같은 반복하중에 대한 LRB의 피로거동을 모사하고 피로시험 전.후의 기본성능의 변화를 파악하였다. 이러한 LRB의 기본성능에 대한 실험온 LRB의 성능에 대한 검증과 함께 LRB의 거동에 대한 불확실성을 줄일 수 있는 기본 자료로 축적할 수 있으며, 현재 한국도로공사 도로교통기술원에서 마련중인 지진격리장치(LRB) 성능시험기준(안)의 정립에 기초 자료로참고하고자 한다.

  • PDF

Seismic Design of Rib-Reinforced RBS (Reduced Beam Section) Steel Moment Connections Based on Equivalent Strut Model (등가 스트럿 모델에 의한 리브 보강 RBS 철골모멘트접합부의 내진설계)

  • Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.5
    • /
    • pp.493-502
    • /
    • 2001
  • This paper describes a seismic design procedure for rib-reinforced RBS(Reduced Beam Section) steel moment connections. Engineers often use rib plates to enhance seismic performance of steel moment connections. thinking that the 2nd moment of inertia is increased so that the tensile stress in the beam flange groove weld is reduced However the force transfer mechanism in the rib connections is completely different from that as predicted by the classical beam theory ; a clear diagonal strut action is present in the rib. By treating the rib as a strut the writer has recently proposed an equivalent strut model that could be used as the basis of a practical design procedure. In this paper the proposed equivalent strut model is briefly presented first. A step-by-step design procedure is then recommended based on the proposed model.

  • PDF