• Title/Summary/Keyword: 성능시험 기준

Search Result 1,040, Processing Time 0.031 seconds

Development of Dose Evaluation Algorithm for Film Badge Using ISO Reference Radiations (ISO 표준방사선장을 이용한 필름배지의 선량평가 알고리즘 개발)

  • Kim, Jang-Lyul;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 1995
  • Since provisions on the technical criteria for personnel dosimetry was amended three years ago, several improvements in the technique of monitoring personnel doses by TLD have taken place, but for the photograpfic film as a personnel monitor, additional investigations should be carried out for its accuracy of dose estimates because of its wide use in the radiation involved industries. So, this paper describes the methods to develope dose evaluation algorithm for photographic film using ISO reference radiations by i) empirical formula, ii) degree-of-fit method, and iii) matrix approximation. These methods show a good agreement between irradiated and calculated dose within tolerance level represented in ANSI N13. 11, and can be used for the dose evaluation of X, ${\gamma}$ and/or radiation fields.

  • PDF

Bearing Capacity Study for Small-Scale Testing of Rotary Pile with Helix Plate (축소모형 로타리 파일의 나선날개에 따른 지지성능에 관한 연구)

  • Shin, Eun-Chul;Kim, Kyeong-Sig;Moon, Hyeong-Rok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.1
    • /
    • pp.37-46
    • /
    • 2016
  • Rotary pile consists a single or multiple helix plate and it is installed into the ground using the rotation of the helix plate. Rotary pile in soft ground is able to be supported by pile shaft and helix plate. When the pile is installed into hard layer relatively, the end bearing capacity is possible to be increased by the lower helix plate. In this paper, small-size rotary piles were manufactured with using steel pipe which is reduced to 1/5 size of the rotary pile on the construction field. Pile load test was carried out on the foundation soil which was formed by weathered soft soil. The bearing capacity of small-scale piles depends on the number of helix plate, the length of plate diameter, and an interval of plates, respectively. The bearing capacity of pile increases about 40% with 3 helix plate and it is also confirmed that the bearing capacity is improved about 10% as the increment of plate interval.

A Study of the Deterioration Restraining Agent Drainage method of Construction (열화억제형 방수공법에 대한 검토)

  • Oh, Dai-Chul;Kim, Eun-Kyum;Kim, Dae-Sang
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1267-1272
    • /
    • 2007
  • In the case of the railway bridge, there are following the progress of works after the drainage method of a bridge surface - vibration proof rubber establishment, track gravel construction and rail construction etc. But these works are not enforced consecutively by the execution and economical reason. This is the reason of the long period of exposure after drainage execution. In many case, from the deterioration phenomenon by long term exposure of surface, there are a lot of occasions that do not keep primitive penetration depth waterproof primitive time. It is the most important that select the drainage method that have durability - it is not fallen in long-term exposure of surface. The major objective of this study is to deduce objective analysis result through examination about the Deterioration Restraining Agent method and to master KNOW-HOW of DRA drainage method. Through the study, minimize economical damage by frequent repair and reinforcement and present the reasonable standard of judgement fot drainage method of construction.

  • PDF

Study on the improvement in Cv of a Main Oxidizer shut-off Valve (CC 산화제 개폐밸브 유량계수 향상에 관한 연구)

  • Hong, Moon-Geun
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.140-148
    • /
    • 2009
  • MOV(Main Oxidizer shut-off Valves) control the combustion of launch vehicle systems by the supply and the isolation of liquid oxygen to a main combustion chamber in launch vehicle systems. Moreover, in the steady operational state, the MOV should secure a constant flow rate of liquid oxygen for combustion instability in the combustion chamber. Concerning the development of MOV, TM(Technology Model) has been manufactured and normal operations of the valve have been verified. However, the Cv of TM has been proved to be too low as compared with a design specification value. Therefore, CFD analysis have been performed by modification of the configurations of TM in order to increase sufficiently Cv of EM(Engineering Model), which is the following model of TM. The modifications of TM configurations such as partial scale-up of valve, increase of stroke length, and outlet angle of 120o would result in a considerable augmentation of Cv. It has been verified by flow capacity tests that the improved Cv of EM is min. 212, which is higher than Cv of TM, 161 by about 32%.

  • PDF

Evaluation of Curving Performance and Running Safety of New High-Power Electric Locomotive (신형 고출력 전기기관차의 곡선추종성 및 주행안전성 평가)

  • Ham, Young Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.6
    • /
    • pp.827-832
    • /
    • 2013
  • In this study, curve responsiveness was assessed based on the lateral force and running safety was evaluated based on the wheel unloading ratio and derailment coefficient, which is the ratio of the wheel load and the lateral force. The evaluation of the curving performance and running safety of the new high-power electric locomotive showed that the derailment coefficient appeared higher when the wheel-set was set to the front of the train instead of being placed backward, and the maximum value of the derailment coefficient was recorded as 0.572 on the Gyeongbu line. Furthermore, the lateral force increased in curved sections, and it appeared to be proportional to the curve radius. Meanwhile, a maximum axis lateral force of 77.6 kN was recorded on the Taebaek line, and the wheel unloading ratio was 47.6% on the Yeongdong line. Finally, the running safety at the maximum speed as well as the through-curve performance of the curve radius satisfied the required standards.

An Empirical Comparison Study on Attack Detection Mechanisms Using Data Mining (데이터 마이닝을 이용한 공격 탐지 메커니즘의 실험적 비교 연구)

  • Kim, Mi-Hui;Oh, Ha-Young;Chae, Ki-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2C
    • /
    • pp.208-218
    • /
    • 2006
  • In this paper, we introduce the creation methods of attack detection model using data mining technologies that can classify the latest attack types, and can detect the modification of existing attacks as well as the novel attacks. Also, we evaluate comparatively these attack detection models in the view of detection accuracy and detection time. As the important factors for creating detection models, there are data, attribute, and detection algorithm. Thus, we used NetFlow data gathered at the real network, and KDD Cup 1999 data for the experiment in large quantities. And for attribute selection, we used a heuristic method and a theoretical method using decision tree algorithm. We evaluate comparatively detection models using a single supervised/unsupervised data mining approach and a combined supervised data mining approach. As a result, although a combined supervised data mining approach required more modeling time, it had better detection rate. All models using data mining techniques could detect the attacks within 1 second, thus these approaches could prove the real-time detection. Also, our experimental results for anomaly detection showed that our approaches provided the detection possibility for novel attack, and especially SOM model provided the additional information about existing attack that is similar to novel attack.

Fundamental Evaluation and Hydration Heat Analysis of Low Heat Concrete with Premixed Cement (저발열형 Premixed Cement를 사용한 콘크리트의 기초물성 평가 및 수화열 해석에 관한 연구)

  • Yoon, Ji-Hyun;Jeon, Joong-Kyu;Jeon, Chan-Ki;Kim, Ki-Hyung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • This study carried out to evaluate the hydration heat analysis and fundamental characteristics such as air content, slump, compressive strength and dry shrinkage according to concrete with premixed cement, ternary concrete and OPC concrete for using concrete with premixed cement. The results of experiment are founded that concrete with premixed cement have sufficient performances such as workability, compressive strength and dry shrinkage. Also, the results of hydration heat analysis are founded that concrete with premixed cement have more performance than ternary concrete and OPC concrete at a point of view for the quality control such as thermal crack reducing and economic benefit. Therefore, it is desirable that concrete with premixed cement should be used to rise durability performance and convenience of maintenance.

A Development of OMS/MP Templete of Guided Weapons on Board Ship (함정탑재 유도무기에 대한 OMS/MP 템플릿 개발)

  • Kwon, Yong-Soo;Lee, Kyoung-Haing
    • Journal of the military operations research society of Korea
    • /
    • v.33 no.2
    • /
    • pp.17-29
    • /
    • 2007
  • This work describes a basic process of OMS/MP in guided weapons on board ship. The OMS/MP which provided basic data of ROC & RAM analysis must be prepared by user But data acquisition Quantified by specific operational environment of ship and related preparing instructions which are not established are now insufficient of reliable weapon systems acquisition. The OMS/MP is an important area that become measures of Acceptance Test and doctrine considering future battlespace environment From a development of the OMS/MP template that describe systematically and as quantitative of shipped guided weapons, combat developer oriented product development & reliable weapon system acquisition are ta be accomplished. This research developed OMS/MP preparation templete that presented quantified OMS/MP derivation and RAM target value calculation process which provide optimum weapon systems design concept to research developers

A Study on Experiment for Improvement of Water Quality in Concrete Block Using Illite and TiO2 Powder (일라이트와 이산화티탄을 활용한 콘크리트 블록의 수질환경개선을 위한 실험연구)

  • Her, Jae-Won;Kang, Kyung-Soo;Kim, Young-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • In order to conduct the "A Study on Experiment for Improvement of Water Quality in Concrete Block Using illite and $TiO_2$ Powder", as a result of the preliminary mortar experiment, water quality purification characteristic test, pollution-resistance test, fish poison test, and the related KS-equivalent tests after manufacturing the actual concrete block, the following conclusion were deduced. As a result of the concrete block functional evaluation equivalent to KS, all the conditions showed higher compressive strength. Even though increase of absorption rate, according to illite replacement in vesicular structure, was expected as a problem, it was replaced after mixing with Titanium dioxide, and then Titanium dioxide was settled in large pores of illite so there was no problem in absorption rate.

The Research for Malfunction and Installation Status of Power Quality Counterplan Equipment of Elevator (엘리베이터의 전원품질용 기기 설치 현황 및 오동작에 관한 조사)

  • Kim, Gi-Hyun;Yi, Geon-Ho;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.107-113
    • /
    • 2006
  • The number of confine-disease for elevator increases every year and then sudden stop, error of level indication stand; those can bring to uneasiness of elevator passenger and malfunction accidents related life accident are increasing. So we researched power quality counterplan equipment(SPD, Filter, Reactor) at site elevator controller room and malfunctions of elevator movement. We could confirm installation of power quality counterplan equipment recently and unchanging the number of malfunction. This data will be used the analysis for mutual relation between Power Quality(Sag, Interruption, ESD, ect.) and malfunction of elevator movement by testing the elevator equipment with EN12016(2004) and IEC standard level.