• Title/Summary/Keyword: 성능시험 기준

Search Result 1,040, Processing Time 0.026 seconds

Verification Test for GBAS Correction Information of KARI IMT (KARI IMT 시스템의 GBAS 보정정보 검증시험)

  • Yun, Young-Sun;Lim, Joon-Hoo;Cho, Jeong-Ho;Heo, Moon-Beom
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.153-161
    • /
    • 2011
  • Korea Aerospace Research Institute (KARI) has implemented an integrity monitor testbed (IMT) to provide archived GPS data and test results for integrity monitoring algorithm development. To verify that the system is implemented based on international standard requirements, this paper represents the basic functional verification test results of the implemented testbed as a GBAS reference station. It compares the IMT generated GBAS message fields with those of PEGASUS, which is a baseline toolset accepted by international GBAS experts, to show the validity of the correction information. It also verifies the integrity and availability of the system through analysis on GBAS user data in the range and position domain.

Effect of Tip-Clearance on the Performance of a Supersonic Impulse Turbine (초음속 충동형 터빈의 팁간극에 따른 성능변화 연구)

  • Jeong, Eun-Hwan;Lee, Hang-Gi;Park, Pyun-Goo;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.117-121
    • /
    • 2008
  • The effect of tip clearance on the performance of a supersonic impulse turbine was investigated experimentally. Test was performed using high pressure air in wide ranges of pressure ratio and rotational speeds. Test revealed that efficiency gradient of the subject turbine at a reference test point was a very low value of 0.05. Turbine efficiency was varied non-linearly with respect to tip clearance. It has been found that efficiency gradient is proportional to the cube of rotational speed at a fixed turbine pressure ratio. It also has been found that efficiency gradient shows its minimum at a reference test pressure ratio irrespective of rotational speeds.

  • PDF

Performance Analysis of the GPS Receiver System under Electromagnetic Test of the KSL V-I Upper-stage (KSLV-I 상단조립체의 전자파시험에서 GPS 수신기 시스템의 성능분석)

  • Moon, Ji-Hyeon;Kwon, Byung-Moon;Shin, Yong-Sul;Choi, Hyung-Don
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.161-169
    • /
    • 2008
  • This paper introduces test configuration and operation method for the GPS receiver system under electromagnetic test of KSLV-I upper-stage as a system qualification level and describes performance analysis of the test results. The GPS receiver system has clearly passed the electromagnetic test specifications of component level which is based on MIL-STD-461E through several design changes. Under electromagnetic test as a system qualification level, the GPS receiver system normally operates in spite of electromagnetic interferences with other systems. Performance of the GPS receiver system is also, not degraded on the condition of electromagnetic field incidence and electrostatic discharge. The KSLV-I GPS receiver system, as a result, is verified on the electromagnetic condition of the KSLV-I upper-stage.

  • PDF

Evaluation of Fracture Behaviours of Cementitious Composites by High-velocity Projectile Impact (고속 비상체 충격에 의한 시멘트 복합체의 파괴거동 평가)

  • Min, Ji-Young;Cho, Hyun-Woo;Lee, Jang-Hwa;Kim, Sung-Wook;Moon, Jae-Heum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.55-62
    • /
    • 2015
  • An importance of infrastructures' protection against crash or blast loading has been an emerging issue as structures are becoming much bigger and population densities in downtown are growing up. However, there exists no such a standard to evaluate the protection performance of construction material itself. Prior to building standards for protection assessment techniques, this study performed gas-gun propelled projectile impact tests with series of contact-type monitoring systems to investigate the applicability of each sensing type. Through the impact tests, failure modes and protection performances of both normal concrete and UHPC (Ultra High Performance Concrete) reinforced by steel fibers were also evaluated. The results showed that LVDT could be applicable for the impact test among contact-type sensors and UHPC with fibers had a remarkable potential to improve protection against impact loading.

압력변환기의 성능평가

  • 임순재;배문섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1990.04a
    • /
    • pp.36-40
    • /
    • 1990
  • 최근 산업고도화의 일환으로 공장자동화와 무인화가 추진되고 있으며, 여기에는 여러가지 변환기가 응용되고 있다. 또 변환기도 종합적인 계측, 제어를 위하여 종래의 기계적 구조를 이용한 것으로부터 전기식으로 바뀌어 가고 있으며, 이에 동반하여 개발된 변환기의 올바른 성능평가 방법이 필수 기술로써 요구되고 있는 실정이다. 올바른 성능평가의 방법은 그 결과의 활용에 있어서, 해당제품에 대한 소비자의 요구사항과의 합치여부를 결정짓는 기준일 뿐 아니라 실험결과의 국제적인 비교의 기준이 되므로 매우 중요한 기술이다. 또 성능평가도 이제까지는 보톤 상온의 환경에 대해서만 고려하였지만, 예상되는 사용환경 전부에 대하여 실시하는 것이 바람직하다. 따라서 본 연구에서는 변환기 또는 센서의 성능평가방법으로 스트레인 게이지를 이용한 압력변환기를 선정하여 그 사용 환경에 대한 성능시험 방법을 제시하고, 실제물에 적용결과를 나타냈다.

The Experimental Study for the Combustion-Property of Sandwich Panels using ISO 5660 Cone Calorimeter (콘칼로리미터를 사용한 샌드위치패널 연소특성에 대한 실험적 연구)

  • Park, Soo-Young;Kim, Dae-Hoi;Im, Hong-Soon
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.33-41
    • /
    • 2006
  • Nowadays in Korea, KS F 2271(Testing method for incombustibility of internal finish material and element of buildings) has been using for the evaluation of fire safety performance of sandwich panels. The test method in Japan and in Korea was based on the same way. When the Japanese standard building code was revised in 2000, the test method in the ISO 5660-1 was adopted for the test method for combustion performance of internal finishing materials and elements of buildings. According to this, the revision version of draft substituting the test method in the KS F 2271 for one in the ISO 5660-1(Cone Calorimeter method) is informed in Korea. In this study, combustion properties of sandwich panels were tested using the cone calorimeter method. Ignition time, peak heat release rate and total heat released of four sandwich panels and four core materials (thermal insulation material), which are widely used in Korea, were tested. Test results were analyzed for each specimen. Finally, test results were classified by Japanese standard building code and Canadian NBC revised.

Development of a Charge&Discharge Test system for Super Capacitor (슈퍼커패시터 성능평가를 위한 충방전 시험 시스템 개발)

  • Kim, Geum-Soo;MOON, Jong-Hyun;Kim, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.494-495
    • /
    • 2011
  • 초고용량의 커패시터는 신재생 에너지 이용의 증가와 더불어 이용 영역이 점차 넓어지고 있어 유망신규시장의 창출이 기대된다. 따라서, 슈퍼커패시터의 성능을 측정하여 시험할 수 있는 충방전 순환 시험기가 필수적이라 할 수 있다. 이를 위해 슈퍼커패시터의 기본 충/방전 특성을 기준으로, 충전과 방전시의 고속계측이 가능하도록 용량 및 내부저항 측정을 위한 회로와 전압유지특성을 측정하기 위한 회로를 설계하였다. 5V, 100A Proto-type의 충방전 시험 시스템 구축으로 특성 평가결과, 전압 및 전류 측정 정밀도 ${\pm}$ 0.1%이내로 확인하였고, 데이터 모니터링 및 로깅을 위한 프로그램을 제작하였다. 또한 전체시스템 구성과 실험결과를 통해, 본 연구에서 개발하고자 하는 슈퍼커패시터용 충방전 시험 시스템이 실제 응용 가능함을 확인하였다.

  • PDF

Study on Material Segregation of Grout and Filling Characteristic of Grouting for Post-Tensioned Concrete Beam (PC 그라우트의 재료분리 및 PC 빔 그라우팅 충전성에 관한 연구)

  • Lee, Jun-Ki;Choi, Joon-Ho;Yoon, Jeong-Seob;Cho, In-Sung
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.419-426
    • /
    • 2010
  • This paper discusses a series of experiments including material improvement in order to ensure quality of grouting for the post-tensioned structure. In presstressed concrete, grouting refers to the construction procedure of filling empty space of duct enclosing the prestress tendons using cementitious material, To date, adequate quality control of the grouting has not been established in Korea because the relationship between the grouting and durability of post-tensioned structure is not well-recognized. The Korean standard does not consider the important material characteristic, wick effect, which is caused by tendons in the ducts, and furthermore current standard testing method does not quantify reasonable material segregation. As a result, the grout material, which satisfies the current material standards, may well exhibit excessive bleeding of water or shrinkage during construction. In this study, international codes and standards related to grouting were surveyed. The mix proportions of the constituents and novel admixtures were suggested to meet equivalently with these standards. Performance of this enhanced grout was compared with common domestic grouts using the international standard testing method. A series of mock-up specimens considering geometry of PC beam was constructed and grout flow pattern was observed as the grout was injected. It was observed that the grouting performance was highly influenced by material properties and filling characteristic can be varied depending on geometry of ducts.

A Study on the External Fault Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System (가정용 연료전지시스템 계통연계형 전력변환장치의 외부사고 성능평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.131-131
    • /
    • 2009
  • 최근 환경규제가 강화되면서 친환경적인 전력생산 요구 등의 외부환경 변화에 따른 우리나라의 전력구조가 기존의 중압 집중형 발전을 탈피한 분산전원 발전에 대한 관심이 증대되고 있는 실정이다. 특히, 분산전원으로서의 전력생산은 공급의 안전성, 경쟁력 및 에너지의 지속성 등이 요구되어지는데, 재생에너지가 가지고 있는 에너지 지속성의 한계 및 설치의 제약성을 탈피할 수 있는 시스템으로 현재 연료전지시스템이 가장 근접해 있는 실정이다. 즉, 도시가스 인프라가 우수하고 인구조밀 지역이 많은 우리나라의 특성상 각 가정 및 건물에 쉽게 설치하고 공급의 안전성을 갖는 건물용 연료전지는 최근 가장 각광받고 있는 분산전원 시스템 중의 하나이다. 올해부터 모니터링사업의 일환으로 수용가에 설치 될 연료전지 시스템이 얼마나 안정적으로 전기와 열을 각 가정에 공급하고 시스템의 안전성을 확보하는 가는 건물용 연료전지의 분산전원으로서의 가능성 및 국민의 수용성을 증대시키는 중요한 역할을 할 것이다. 연료전지시스템은 상용전력과 연계되어 있기 때문에 시스템의 안정성 뿐만 아니라 상용전력의 변화에 대응하여 안정적인 운전을 하는지에 대한 평가가 필수적이다. 이에 따라 본 연구에서는 가정용 연료전지시스템의 성능 및 안전성평가의 일환으로 계통연계형 전력변환장치의 성능 및 안전성을 평가 하고자 한다. 연료전지 검사를 위한 계통연계형 전력변환장치의 시험평가 항목으로는 크게 정상특성성능시험, 보호기능성능시험, 과도응답특성성능시험 및 외부사고성능시험 등으로 나뉘어진다. 본 연구에서는 외부사고 성능시험 항목들인 출력측 단락시험, 계통전압 순간정전?순간강하시험 및 부하차단 시험 등을 통하여 외부사고에 대한 성능 및 안전성을 평가하였다. 외부사고 성능시험의 주 목적은 시스템의 이상 운전이 아니라 외부의 영향에 따른 시스템의 안전성 및 전력품질을 평가한다. 출력측 단락시험을 수행하기 위해서 전력변환장치를 정격 출력 전압, 정격 출력 주파수 및 정격 출력에서 운전한 후, 교류 전원장치는 단락 전류를 검출하여, 사고 발생 후 0.3초 이내에 개방하도록 설정하였다. 여기서, 단락 저항 Rsc를 정격 전류의 10배 이상에 해당하는 부하와 같은 값으로 설정하였다. 스위치 SWSC를 폐로하여 단락 상태를 만들며, 이 때 전력변환장치의 출력전류와 차단 또는 정지 시간을 측정하였다. 실험 결과에 대한 판정기준은 단락전류를 검출하여 0.5초 이내에 개폐기 개방 또는 게이트 블록 기능이 동작하여 시스템을 안정하게 정지시키고 시스템 어떤 부위에도 손상이 없어야 한다. 실험 결과 파워컨디셔너의 출력전류 및 차단 또는 정지된시간이 40ms로 나타났고, 출력전류의 파형도 매우 안정함을 볼 수 있었다. 이와 같이 모든 실험을 수행한 결과 외부사고에 대하여 시스템이 안전하게 정지하는 등 연료전지 시스템의 안전성을 확인하였다.

  • PDF