• Title/Summary/Keyword: 성능비교

Search Result 19,661, Processing Time 0.058 seconds

Matching Points Filtering Applied Panorama Image Processing Using SURF and RANSAC Algorithm (SURF와 RANSAC 알고리즘을 이용한 대응점 필터링 적용 파노라마 이미지 처리)

  • Kim, Jeongho;Kim, Daewon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.144-159
    • /
    • 2014
  • Techniques for making a single panoramic image using multiple pictures are widely studied in many areas such as computer vision, computer graphics, etc. The panorama image can be applied to various fields like virtual reality, robot vision areas which require wide-angled shots as an useful way to overcome the limitations such as picture-angle, resolutions, and internal informations of an image taken from a single camera. It is so much meaningful in a point that a panoramic image usually provides better immersion feeling than a plain image. Although there are many ways to build a panoramic image, most of them are using the way of extracting feature points and matching points of each images for making a single panoramic image. In addition, those methods use the RANSAC(RANdom SAmple Consensus) algorithm with matching points and the Homography matrix to transform the image. The SURF(Speeded Up Robust Features) algorithm which is used in this paper to extract featuring points uses an image's black and white informations and local spatial informations. The SURF is widely being used since it is very much robust at detecting image's size, view-point changes, and additionally, faster than the SIFT(Scale Invariant Features Transform) algorithm. The SURF has a shortcoming of making an error which results in decreasing the RANSAC algorithm's performance speed when extracting image's feature points. As a result, this may increase the CPU usage occupation rate. The error of detecting matching points may role as a critical reason for disqualifying panoramic image's accuracy and lucidity. In this paper, in order to minimize errors of extracting matching points, we used $3{\times}3$ region's RGB pixel values around the matching points' coordinates to perform intermediate filtering process for removing wrong matching points. We have also presented analysis and evaluation results relating to enhanced working speed for producing a panorama image, CPU usage rate, extracted matching points' decreasing rate and accuracy.

Theoretical Study on Optimal Conditions for Absorbent Regeneration in CO2 Absorption Process (이산화탄소 흡수 공정에서 흡수액 최적 재생 조건에 대한 이론적 고찰)

  • Park, Sungyoul
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.1002-1007
    • /
    • 2012
  • The considerable portion of energy demand has been satisfied by the combustion of fossil fuel and the consequent $CO_2$ emission was considered as a main cause of global warming. As a technology option for $CO_2$ emission mitigation, absorption process has been used in $CO_2$ capture from large scale emission sources. To set up optimal operating parameters in $CO_2$ absorption and solvent regeneration units are important for the better performance of the whole $CO_2$ absorption plant. Optimal operating parameters are usually selected through a lot of actual operation data. However theoretical approach are also useful because the arbitrary change of process parameters often limited for the stability of process operation. In this paper, a theoretical approach based on vapor-liquid equilibrium was proposed to estimate optimal operating conditions of $CO_2$ absorption process. Two $CO_2$ absorption processes using 12 wt% aqueous $NH_3$ solution and 20 wt% aqueous MEA solution were investigated in this theoretical estimation of optimal operating conditions. The results showed that $CO_2$ loading of rich absorbent should be kept below 0.4 in case of 12 wt% aqueous $NH_3$ solution for $CO_2$ absorption but there was no limitation of $CO_2$ loading in case of 20 wt% aqueous MEA solution for $CO_2$ absorption. The optimal regeneration temperature was determined by theoretical approach based on $CO_2$ loadings of rich and lean absorbent, which determined to satisfy the amount of absorbed $CO_2$. The amount of heating medium at optimal regeneration temperature is also determined to meet the difference of $CO_2$ loading between rich and lean absorbent. It could be confirmed that the theoretical approach, which accurately estimate the optimal regeneration conditions of lab scale $CO_2$ absorption using 12 wt% aqueous $NH_3$ solution could estimate those of 20 wt% aqueous MEA solution and could be used for the design and operation of $CO_2$ absorption process using chemical absorbent.

A Study on the Governance of U.S. Global Positioning System (미국 글로벌위성항법시스템(GPS)의 거버넌스에 관한 연구 - 한국형위성항법시스템 거버넌스를 위한 제언 -)

  • Jung, Yung-Jin
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.35 no.3
    • /
    • pp.127-150
    • /
    • 2020
  • A Basic Plan for the Promotion of Space Development (hereinafter referred to as "basic plan"), which prescribes mid- and long-term policy objectives and basic direction-setting on space development every five years, is one of the matters to be deliberated by the National Space Committee. Confirmed February 2018 by the Committee, the 3rd Basic Plan has a unique matter, compared to the 2nd Basic Plan. It is to construct "Korean Positioning System(KPS)". Almost every country in the world including Korea has been relying on GPS. On the occasion of the shooting down of a Korean Air flight 007 by Soviet Russia, GPS Standard Positioning Service has been open to the world. Due to technical errors of GPS or conflict of interests between countries in international relations, however, the above Service can be interrupted at any time. Such cessation might bring extensive damage to the social, economic and security domains of every country. This is why some countries has been constructing an independent global or regional satellite navigation system: EU(Galileo), Russia(Glonass), India(NaVic), Japan(QZSS), and China(Beidou). So does South Korea. Once KPS is built, it is expected to make use of the system in various areas such as transportation, aviation, disaster, construction, defense, ocean, distribution, telecommunication, etc. For this, a pan-governmental governance is needed to be established. And this governance must be based on the law. Korea is richly experienced in developing and operating individually satellite itself, but it has little experience in the simultaneous development and operation of the satellites, ground, and users systems, such as KPS. Therefore we need to review overseas cases, in order to minimize trial and error. U.S. GPS is a classic example.

Dehumidification and Temperature Control for Green Houses using Lithium Bromide Solution and Cooling Coil (리튬브로마이드(LiBr) 용액의 흡습성질과 냉각코일을 이용한 온실 습도 및 온도 제어)

  • Lee, Sang Yeol;Lee, Chung Geon;Euh, Seung Hee;Oh, Kwang Cheol;Oh, Jae Heun;Kim, Dea Hyun
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.337-341
    • /
    • 2014
  • Due to the nature of the ambient air temperature in summer in korea, the growth of crops in greenhouse normally requires cooling and dehumidification. Even though various cooling and dehumidification methods have been presented, there are many obstacles to figure out in practical application such as excessive energy use, cost, and performance. To overcome this problem, the lab scale experiments using lithium bromide(LiBr) solution and cooling coil for dehumidification and cooling in greenhouses were performed. In this study, preliminary experiment of dehumidification and cooling for the greenhouse was done using LiBr solution as the dehumidifying materials, and cooling coil separately and then combined system was tested as well. Hot and humid air was dehumidified from 85% to 70% by passing through a pad soaked with LiBr, and cooled from 308K to 299K through the cooling coil. computational Fluid Dynamics(CFD) analysis and analytical solution were done for the change of air temperature by heat transfer. Simulation results showed that the final air temperature was calculated 299.7K and 299.9K respectively with the deviation of 0.7K comparing the experimental value having good agreement. From this result, LiBr solution with cooling coil system could be applicable in the greenhouse.

Diagnostic Accuracy of PET and MR for Detecting Liver Metastasis from Colorectal Cancer (대장-직장암의 간전이에서 FDG PET과 MR의 진단 성능)

  • Park, Eun-Kyung;Kang, Won-Jun;Eo, Jae-Seon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.249-256
    • /
    • 2006
  • Purpose: Although computed tomography (CT) is widely used for diagnosing liver metastasis from colorectal cancer, diagnostic accuracy of CT is not satisfactory. Magnetic resonance (MR) imaging and F-18 FDG PET has been reported to be superior to CT. However, studies on direct comparison of PET and MR are scarce. We compared the diagnostic accuracy of FDG PET and MR in detecting liver metastasis from colorectal cancer. Materials and Methods: Among 363 colorectal cancer patients who underwent F-18 FDG PET (ECAT, Siemens-CTI, Knoxville; Gemini, Philips, Milpitas, U.S.), 26 patients (M:F=17:9, age=$62{\pm}11$) underwent MR to evaluate suspicious metastatic liver lesions. Finally, 35 liver lesions detected by CT from 26 patients were enrolled for analysis. PET and MR results were compared with pathologic reports, clinical findings or follow-up results. Results: Of the 35 lesions, 18 lesions (51.4%) were diagnosed as liver metastases, while remaining 17 (48.6%) as benign. The sensitivity and the specificity of PET were 94.4% and 94.1%, respectively, compared to 100% and 82.4% for MR. MR and PET was concordant in 30 lesions (85.7%: 17 metastatic (94.4%) and 13 benign (76.5%) lesions. ROC curve analysis revealed maximal SUV of 3.1 as the optimum standard in differentiating metastatic from benign liver lesions (AUC=0.897, p<0.001, sensitivity 83.3%, specificity 94.1%). For small lesions less than 1 cm ln diameter (n=20), diagnostic accuracy of PET was comparable to that of MR. Conclusion: F-18 FDG PET showed good diagnostic performance in detecting liver metastasis from colorectal cancer, which was comparable to MR.

Cost-effectiveness of Myocardial Perfusion SPECT for Diagnosis of Coronary Artery Disease in Korea: Comparison with Exercise ECG and Coronary Angiography (우리 나라에서 관동맥질환을 진단하는 약물부하 심근관류 SPECT의 비용효과 성능: 운동부하심전도와 관동맥조영술과 비교)

  • Lee, Dong-Soo;Kang, Keon-Wook;Jang, Myung-Jin;Cheon, Gi-Jeong;Lee, Myoung-Mook;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.207-221
    • /
    • 2000
  • Purpose: Cost-effectiveness of myocardial SPECT for the diagnosis of coronary artery disease was investigated considering the present and amended costs of myocardial SPECT and exercise ECG in Korea. Materials and Methods: Four diagnostic tactics such as 1) coronary angiography (CAG) after exercise ECG, 2) CAG after myocardial SPECT, 3) direct CAG, and 4) CAG after myocardial SPECT following exercise ECG were chosen. Costs were calculated using the present costs of various tests and effects represented by Quality Adjusted Life Year (QALY) were estimated. Difference of QALY (${\Delta}QALY$) was calculated by subtracting QALY of diagnosed/treated cases from QALY of undiagnosed cases. $Cost/{\Delta}QALY$ was calculated and compared between four different tactics according to pre-test probability. Results: When pre-test probability was equal to or larger than 0.6, direct CAG was the most cost-effective. When pre-test probability was between 0.2 and 0.6, CAG after myocardial SPECT following exercise ECG was the most cost-effective. CAG after myocardial SPECT was the second most cost-effective. Cost-effectiveness was similar when the costs of exercise ECG were doubled or quadrupled. CAG after exercise ECG was always the least cost-effective. Conclusion: Myocardial SPECT with or without preceding exercise ECG was the most cost-effective method to diagnose coronary artery disease in the present or expected amended cost system.

  • PDF

Detection for Residual Thyroid Tissue and Metastatic Lesion after Total Thyroidectomy in Patients with Differentiated Thyroid Cancer: Comparison between Tc-99m Pertechnetate Sean and High Dose I-131 Therapy Sean (분화 갑상선암 환자의 수술후 잔여갑상선조직 및 전이병소의 진단: Tc-99m Pertechnetate 스캔과 고용량 옥소 치료 후 I-131 스캔의 비교)

  • Lee, Joo-Ryung;Ahn, Byeong-Cheol;Jeong, Shin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.120-127
    • /
    • 2003
  • Purpose: To evaluate diagnostic sensitivity of nuclear imaging in the detection of residual thyroid tissue and metastatic lesion, we have compared neck scintigrams with Tc-99m pertechnetate (Tc-99m scan) and high dose I-131 iodide (I-131 scan) in patients with differentiated thyroid cancer. Subjects and Methods: One hundred thirty-five thyroidectomized patients for differentiated thyroid cancer were enrolled in this study. Twenty-three had a previous history of radioiodine therapy. Planar and pin-hole images of anterior neck with Tc-99m were acquired at 20 minutes after injection, followed by I-131 scan three days after high-dose radioiodine therapy within 7 days interval. Patients were asked to discontinue thyroid hormone replacement more than 4 weeks. Results: All subjects were in hypothyroid state. Seventy out of 135 patients (51.9%) showed concordant findings between Tc-99m and I-131 scans. I-131 scan showed higher number of uptake foci in all of 65 patients showing discordant finding. Tc-99m scan showed no thyroid bed uptake in 34 patients, whereas 23 of them (67.6%) showed bed uptake in I-131 scan. Tc-99m scan did not show any uptake in thyroid bed in 11 of 112 patients without previous history of radioiodine therapy, but 9 of them showed bed uptake in I-131 scan. Tc-99m scan showed no bed uptake in all of the 23 patients with previous history of radioiodine therapy, in contrast 14 of them (60.9%) showed bed uptake in I-131 scan. Conclusion: These results suggest that Tc-99m scan has poor detectability for residual thyroid tissue or metastatic lesion in thyroidectomized differentiated thyroid cancer patients, compared to high dose I-131 therapy scan. Tc-99m scan could not detect any remnant tissue or metastatic lesion in patients with previous history of radioiodine treatment, especially.

A Study on the Reduction of Kidney Uptake of 18F-FDG due to the Water Intake at the Time of Additional Examination in the PET/CT scan (PET/CT 검사에서 추가 검사 시 수분섭취에 따른 18F-FDG의 신장 섭취 감소에 대한 고찰)

  • Lee, Yi Lang;Kim, Sang Gyu;Ham, Jun Chul;Nam-Koong, Hyuk;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.47-51
    • /
    • 2016
  • Purpose By ingestion of 18F-FDG of kidney of PET/CT during the inspection, if additional examination is required, depending on whether you want to water intake, we want to confirm a change in the rate of decrease of F-18 FDG of the kidney. Materials and Methods The 80 patients without kidney disease were performed PET/CT examination. Device was analyzed after setting the kidney to a three-dimensional region of interest. In patients require additional examination, and inspection after 30 minutes, a PET/CT torso examination after the water of the 500 cc ingested at a time. After the addition of both water intake group and no hydration group of kidney of SUV, it was compared with PET/CT torso scan. Results High and low of the kidney SUV did not show a significant difference in the rate of decrease. Reduction rates of background (BKG) of additional examination was 2.8% and reduction rates of SUV was 49.7% (Hydration) : -6.8% (No hydration), so did show a significant difference. In the image blind test, the average point score of hydration and no hydration was 34.25 : 17.25. Conclusion An undercurrent of 18F-FDG in the kidney at the time of torso examination, it was confirmed that the reduction rate after the addition of water intake is high. It is considered that can be expected to improve the quality of an image due to a decrease in elongation through the kidneys examination with additional fluid intake as needed intake.

  • PDF

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

High LO-RF Isolation W-band MIMIC Single-balanced Mixer (높은 LO-RF 격리 특성의 W-band MIMIC Single-balanced 믹서)

  • An Dan;Lee Bok-Hyung;Lim Byeong-Ok;Lee Mun-Kyo;Lee Sang-Jin;Jin Jin-Min;Go Du-Hyun;Kim Sung-Chan;Shin Dong-Hoon;Park Hyung-Moo;Park Hyim-Chang;Kim Sam-Dong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.6 s.336
    • /
    • pp.67-74
    • /
    • 2005
  • In this paper, high LO-RF isolation W-band MIMIC single-balanced mixer was designed and fabricated using a branch line coupler and a $\lambda$/4 transmission line. The simulation results of the designed 94 GHz balun show return loss of -27.9 dB, coupling of -4.26 dB, and thru of -3.77 dB at 94 GHz, respectively. The isolation and phase difference were 23.5 dB and $180.2^{\circ}$ at 94 GHz. The W-band MIMIC single-balanced mixer was designed using the 0.1 $\mu$m InGaAs/InAlAs/GaAs Metamorphic HEMT diode. The fabricated MHEMT was obtained the cut-off frequency(fT) of 189 GHz and the maximum oscillation frequency(fmax) of 334 GHz. The designed MIMIC single-balanced mixer was fabricated using 0.1 $\mu$m MHEMT MIMIC Process. From the measurement, the conversion loss of the single-balanced mixer was 23.1 dB at an LO power of 10 dBm. Pl dB(1 dB compression point) of input and output were 10 dBm and -13.9 dBm respectively. The LO-RF isolations of single-balanced mixer was obtained 45.5 dB at 94.19 GHz. We obtained in this study a higher LO-RF isolation compared to some other balanced mixers in millimeter-wave frequencies.