• Title/Summary/Keyword: 성능기초설계

Search Result 898, Processing Time 0.023 seconds

The Evaluation of Seismic Performance for Concrete-filled Steel Piers (콘크리트 충전 강교각의 내진 성능 평가)

  • 정지만;장승필;인성빈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.5
    • /
    • pp.53-58
    • /
    • 2002
  • A recent development, a concrete-filled steel(CFS) pier is an alternative to a reinforced concrete bridge pier in an urban area, because of its fast construction and excellent ductility against earthquakes. The capacity of CFS piers has not been used to a practical design, because there is no guide of a seismic design for CFS piers. Therefore, the guide of a seismic design value is derived from tests of CFS piers in order to apply it to a practical seismic design. Steel piers and concrete-filled steel piers are tested with constant axial load using quasi-static cyclic lateral load to check ductile capacity and using the real Kobe ground motion of pseudo-dynamic test to verify seismic performance. The results prove that CFS piers have more satisfactory ductility and strength than steel piers and relatively large hysteretic damping in dynamic behaviors. The seismic performance of steel and CFS piers is quantified on the basis of the test results. These results are evaluated through comparison of both the response modification factor method by elastic response spectrum and the performance-based design method by capacity spectrum and demand spectrum using effective viscous damping. The response modification factor of CFS piers is presented to apply in seismic design on a basis of this evaluation for a seismic performance.

Seismic Performance Evaluation of Reinforced Concrete Moment Framed Low-story School buildings (철근콘크리트 모멘트 골조 저층형 학교건축물의 내진성능 평가)

  • Hwang, Ji-Hyun;Park, Tae-Won;Han, Ju-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4580-4586
    • /
    • 2013
  • Many school buildings are not applied seismic code because of small size structures. But it must be designed to show enough structural performance when subject to earthquake due to the fact that most of school buildings are generally used as public shelters when the natural disasters. In this study, the seismic risk of the reinforced concrete school building structure which is the most common types of school structures was evaluated by using the seismic performance evaluation methods. As a result, model structures don't have enough seismic performance.

Tensile Load Transmission Capacity of H-shaped Beam by Stud Connectors (스터드 커넥터로 연결된 H형강보의 인장하중 전달성능)

  • Lee, Myung Jae;Choi, Wan Chol;Kim, Won Ki;Kim, Jae Hee;Lee, Sang Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.267-274
    • /
    • 2004
  • The objective of this study is to evaluate tensile load transmission capacity of H-shaped beam about design load by stud connector. The basic test of stud connecter was conducted and two specimens of full-scale size were tested under monotonic tensile loading condition. The parameter of tests is the size of the H-shaped beams. The results show that tensile load transmission capacity of H-shape beam about design load by stud connectors is excellent observing to the design code of steel structures of Architectural Institute of Korea.

Preliminary Design of Human Powered Aircraft by the Consideration of Aerodynamic Performance (공기역학적 성능을 고려한 인간동력항공기 개념 설계)

  • Kang, Hyungmin;Kim, Cheolwan
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.180-185
    • /
    • 2013
  • In this study, preliminary design of human powered aircraft was performed by considering the aerodynamic performance. For this, overall weight including the aircraft and pilot was determined. Then, the main wing and horizontal/vertical tail were designed with appropriate selection of the airfoils and planform shapes. Based on these, three dimensional flow was calculated to obtain lift and drag coefficients and the position of center of gravity (CG). Consequently, it was shown that the lift and power of the aircraft satisfied the constraints of the minimum required lift and the pilot's available power. Also, the CG of the aircraft was located at aerodynamic center (AC) of the main wing, which guaranteed 26% of the static margin.

Wide-angle Optical Module Design for Mobile Phone Camera Using Recursive Numerical Computation Method (재귀적 수치 계산법을 적용한 모바일 폰용 광각 광학계 설계)

  • Kyu Haeng Lee;Sung Min Park;Kye Jin Jeon
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.4
    • /
    • pp.164-169
    • /
    • 2024
  • We applied recursive numerical computation to create a basic design of a camera optical module for mobile phones. To enhance the resolution performance for a 38-degree field of view, we constructed the optical system with six non-spherical lenses. However, to increase its applicability to a compact mobile phone, we limited the overall length to 5 mm in the design. Using the data obtained from the basic design, we proceeded with optimization design using the Zemax design tool. The optimized optical system achieved a resolution performance with a modulation transfer function value of more than 19% for a 280 lines/mm pattern and image distortion within 1.0% for all wavelength rays. In this paper, we verify the feasibility of using recursive numerical computation for the basic design of a compact mobile phone camera.

An Experimental Study For Improvement of Joint Detail of Steel Pier - Foundation (강재교각 기초부의 연결상세 개선을 위한 실험적 연구)

  • Kim, Hee-Ju;Ham, Jun-Su;Yang, Sung-Don;Hwang, Won-Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.5
    • /
    • pp.491-501
    • /
    • 2012
  • Generally, a steel pier-foundation has been designed and constructed with a anchor frame. However, because of the complicated design and construction, the foundation's size has become large and has been overdesigned. In this study, three specimens were made and the tests were conducted to suggest a new shape in regard to the pier-foundation's joint details using the high performance steel. One of the specimens was made up of the general anchors and the anchor frame. Another specimen consisted of the high tension anchors and the studs, and the other specimen was composed of the high tension anchors and the inner steels. After the performance of each specimen was compared and analyzed, the behavior characteristics according to the joint were analyzed.

Synthesis of GBSB Neural Associative Memories Using GEVP (GEVP를 이용한 GBSB 연상 메모리의 설계)

  • Park, Yon-Mook;Park, Joo-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.2872-2875
    • /
    • 1999
  • 본 논문은 주어진 적합한 이진 패턴들의 집합이 점근적으로 안정한 평형점들로써 저장되는 최적으로 성능을 갖는 GBSB (generalized brain-state-in-a-box)의 설계가 고려된다. GBSB 모델의 정성적 특성에 기초하여, 설계 문제가 제약 조건을 가한 최적화 문제로 공식화된다. 다음으로, 우리는 이 문제를 GEVP (generalized eigenvalue Problem)라고 불리는 최적화 문제로 변환한다. 제안된 방법을 예증하기 위함과 기존의 방법과의 비교를 위해서 설계 예제가 주어진다.

  • PDF

증류탑의 제어 시스템 설계

  • 양대륙
    • ICROS
    • /
    • v.2 no.1
    • /
    • pp.93-100
    • /
    • 1996
  • 본 논문에서는 증류탑 제어 구조의 선택과 선택된 조작변수를 이용한 조성제어 전략에 대하여 고찰해 보았다. 제어구조 설계시 증류탑의 양끝에서 물질 수지와 에너지 수지제어를 조합해 주는 두 파라미터에 의해, 예상되어지는 제어구조를 동적 구조 변환 기법을 사용하여 쉽게 분석할 수 있으며, Combined balance 방법으로부터 시작하여, 증류탑에 대한 3가지의 새로운 방법을 소개하였다. 제어구조를 결정하는데 ITAE와 같은 닫힌 루프 성능지표에 기초한 최적 combined balance 구조는 multiloop dual 조성 제어에 대해 다른 구조보다 뛰어난 성능을 보이고 있다. 이 방법은 새로운 증류탑의 제어구조를 설계할 때나, 기존의 증류탑 성능을 향상시키는 데에 사용할 수 있다. 이상과 같이 제어구조가 결정된 후 사용할 수 있는 여러 가지 제어전략을 소개하였다. 제어전략의 선택은 사용자의 목적에 따라 적절한 것을 선택하면 되는데, 대부분의 경우는 적당한 제어구조를 Combined balance 구조로서 결정하게 되면 간단한 형태의 전통적 제어기를 사용해도 무방하며 제어구조의 선택이 선행되지 않으면 MPC와 같은 고급 제어전략을 사용하여 상호작용 등에 의하여 생기는 문제를 해결하는 것이 바람직하다.

  • PDF

A Computational Study on the Performance Prediction of the Two-Stage Axial Compressor (2단 축류압축기 성능예측에 대한 수치해석적 연구)

  • Choi, Chang-Ho;Kim, Jin-Han;Yang, Soo-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.77-83
    • /
    • 2002
  • A computational study on the performance prediction of a two-stage axial compressor has been performed. A quasi-steady mixing-plane method is used on the rotor/stator interface to simulate the unsteady interaction phenomena. Detail flow mechanisms, for example, choke, stall, shock/boundary interaction, etc., have been observed and discussed in conjunction with performance characteristics. Calculational data agree reasonably well with the experimental data in terms of the performance characteristics showing the applicability of computational methods to the design validation of multistage axial compressors instead of experimental methods. But it is found that the stall margin of the original compressor was rather small, thus the design modification adopting a simple 1D/2D method has been conducted and its corresponding computations are also carried out. As a result of the redesign process, the stall margin becomes wide enough, but the overall performance is unsatisfactory, therefore, it seems that the redesign of the blades using 3-D methods is needed in the future work.

Design and Structural Analysis of Electric Saver Box (전력절감기함의 설계 및 구조해석)

  • Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2435-2440
    • /
    • 2012
  • In this paper, Solidworks was used to do a conceptional design of an box of an electric saver in order to manufacture an electric saver having a different performance and model. Based on this, analysis was made considering weight concentrated on an box. 3-dimensional finite element analysis code, ANSYS was applied to obtain stress, strain and deformation in order to secure durability and these data was reflected to a detailed drawing.