• Title/Summary/Keyword: 성능검증

Search Result 9,148, Processing Time 0.038 seconds

Dehumidification and Temperature Control for Green Houses using Lithium Bromide Solution and Cooling Coil (리튬브로마이드(LiBr) 용액의 흡습성질과 냉각코일을 이용한 온실 습도 및 온도 제어)

  • Lee, Sang Yeol;Lee, Chung Geon;Euh, Seung Hee;Oh, Kwang Cheol;Oh, Jae Heun;Kim, Dea Hyun
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.337-341
    • /
    • 2014
  • Due to the nature of the ambient air temperature in summer in korea, the growth of crops in greenhouse normally requires cooling and dehumidification. Even though various cooling and dehumidification methods have been presented, there are many obstacles to figure out in practical application such as excessive energy use, cost, and performance. To overcome this problem, the lab scale experiments using lithium bromide(LiBr) solution and cooling coil for dehumidification and cooling in greenhouses were performed. In this study, preliminary experiment of dehumidification and cooling for the greenhouse was done using LiBr solution as the dehumidifying materials, and cooling coil separately and then combined system was tested as well. Hot and humid air was dehumidified from 85% to 70% by passing through a pad soaked with LiBr, and cooled from 308K to 299K through the cooling coil. computational Fluid Dynamics(CFD) analysis and analytical solution were done for the change of air temperature by heat transfer. Simulation results showed that the final air temperature was calculated 299.7K and 299.9K respectively with the deviation of 0.7K comparing the experimental value having good agreement. From this result, LiBr solution with cooling coil system could be applicable in the greenhouse.

Barium Compounds through Monte Carlo Simulations Compare the Performance of Medical Radiation Shielding Analysis (몬테카를로 시뮬레이션을 통한 바륨화합물의 의료방사선 차폐능 비교 분석)

  • Kim, Seonchil;Kim, Kyotae;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.403-408
    • /
    • 2013
  • This study made a tentative estimation of the shielding rate of barium compound by thickness through monte carlo simulation to apply medical radiation shielding products that can replace existing lead. Barium sulfate($BaSO_4$) was used for the shielding material, and thickness of the shielding material specimen was simulated from 0.1 mm to 5 mm by applying $15{\times}15cm^2$ of specimen area, $4.5g/cm^3$ of density of barium sulfate, and $11.34g/cm^3$ density of lead. Entered source was simulated with 10kVp Step in consecutive X-ray energy spectrum(40 kVp ~ 120 kVp). Absorption probability in 40 kVp ~ 60 kVp showed same shielding rate with lead in 3 mm ~ 5 mm of thickness, but it was identified that under 2 mm, the shielding rate was a bit lower than the existing lead shielding material. Also, the shielding rate in 70 kVp ~ 120 kVp energy band showed similar performance as the existing lead shielding material, but it was tentatively estimated as fairly low shielding rate below 0.5 mm. This study estimated the shielding rate of barium compound as the thickness function of x-ray energy band for medical radiation through monte carlo simulation, and made comparative analysis with existing lead. Also, this study intended to verify application validity of the x-ray shielding material for medical radiation of pure barium sulfate. As a result, it was estimated that the shielding effect was 95% higher than the existing lead 1.5 mm in at least 2 mm thickness of barium compound in medical radiation energy band 70 kVp ~ 120 kVp, and this result is considered valid to be provided as a base data in weight lightening production of radiation shielding product for medical radiation.

A Study on the Reduction of Kidney Uptake of 18F-FDG due to the Water Intake at the Time of Additional Examination in the PET/CT scan (PET/CT 검사에서 추가 검사 시 수분섭취에 따른 18F-FDG의 신장 섭취 감소에 대한 고찰)

  • Lee, Yi Lang;Kim, Sang Gyu;Ham, Jun Chul;Nam-Koong, Hyuk;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.47-51
    • /
    • 2016
  • Purpose By ingestion of 18F-FDG of kidney of PET/CT during the inspection, if additional examination is required, depending on whether you want to water intake, we want to confirm a change in the rate of decrease of F-18 FDG of the kidney. Materials and Methods The 80 patients without kidney disease were performed PET/CT examination. Device was analyzed after setting the kidney to a three-dimensional region of interest. In patients require additional examination, and inspection after 30 minutes, a PET/CT torso examination after the water of the 500 cc ingested at a time. After the addition of both water intake group and no hydration group of kidney of SUV, it was compared with PET/CT torso scan. Results High and low of the kidney SUV did not show a significant difference in the rate of decrease. Reduction rates of background (BKG) of additional examination was 2.8% and reduction rates of SUV was 49.7% (Hydration) : -6.8% (No hydration), so did show a significant difference. In the image blind test, the average point score of hydration and no hydration was 34.25 : 17.25. Conclusion An undercurrent of 18F-FDG in the kidney at the time of torso examination, it was confirmed that the reduction rate after the addition of water intake is high. It is considered that can be expected to improve the quality of an image due to a decrease in elongation through the kidneys examination with additional fluid intake as needed intake.

  • PDF

A Study on the Performance of Cloud-based VDI Adoption: Comparing between IS administrators and business users (클라우드 기반 VDI 도입 성과에 관한 연구 - 시스템 관리자와 일반 사용자의 비교를 중심으로 -)

  • Kim, Il-Han;Kwon, Sun-Dong
    • Management & Information Systems Review
    • /
    • v.37 no.2
    • /
    • pp.149-167
    • /
    • 2018
  • The purpose of this study is to analyze the performance of Virtual Desktop Infrastructure(VDI) adoption. VDI performance was measured by IS manager (system quality, security, and managerial operation) and business user (usability, access, and user satisfaction). The survey questionnaires were developed for measuring VDI performance. 84 data samples were collected from the companies that had adopted cloud-based VDI. This research model was verified by Smart-PLS and SPSS. The research findings were as follows: First, the companies using VDI experienced actual performance, but they did not attain their expectation. Second, as results of comparing between IS managers and business users, IS administrators had considerably higher performance than business users, which indicates that there were big differences in performance perception among users. Compared with prior research such as technical trend, system construction, and performance improvement, this study has the following implications. First, by comparing the expected performance with the actual performance of the companies that have implemented and operating VDI, it was suggested how a company that wants to adopt VDI can manage the expectation level of VDI and achieve higher actual performance. Second, because the perception of VDI performance differs between business users and system managers, it is meaningful that a fair evaluation of VDI performance requires a balanced consideration of business users and system managers.

Removal Efficiency of Ammonia and Toluene using Mobile Scrubber (이동형 스크러버를 이용한 암모니아 및 톨루엔의 제거 효율)

  • Kim, Jae-Young;Kim, Jang-Yoon;Lee, Yeon Hee;Kim, Min Sun;Kim, Min-Su;Kim, Hyun Ji;Ryu, Tae In;Jeong, Jae Hyeong;Hwang, Seung-Ryul;Kim, Kyun;Lee, Jin Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2018
  • BACKGROUND: The mobile vortex wet scrubber was developed to remove the harmful chemicals from accidental releases. However, there was a disadvantage that it was limitedly used for volatile organic compounds (VOCs) such as toluene according to the physicochemical properties. This study compared the removal efficiencies of an improved mobile scrubber on toluene and ammonia by applying diverse adsorption and absorption methods. METHODS AND RESULTS: The removal efficiencies on harmful chemicals were examined using various adsorption and absorption methods of water vortex process (C), phosphoric acid-impregnated activated carbon adsorption (PCA), pH-controlled water (pH 2.5) vortex process absorption with sulfuric acid (SWA) after ammonia exposure, granular activated carbon adsorption (GCA), and activated carbon mat adsorption (CMA) after toluene exposure. As a result, the best removal efficiency was shown in the SWA for ammonia and GCA for toluene. Also, the SWA and GCA methods were compared with different concentration levels. In the case of ammonia exposure (5, 10 and 25%), there was no difference by concentration levels, and the concentration in the outlet gradually increased, with pH change from acid to base. In the case of toluene exposure (50, 75 and 100%), the outlet concentration was higher relative to the exposure concentration in the initial 10 min, but the outlet concentration was remained steady after 10 min. CONCLUSION: The newly improved mobile scrubber was also effective in removing VOCs through adsorption techniques (activated carbon, activated carbon fiber, carbon mat filter etc.), as well as removing acid-base harmful chemicals by neutralization reaction.

P300 speller using a new stimulus presentation paradigm (새로운 자극제시방법을 사용한 P300 문자입력기)

  • Eom, Jin-Sup;Yang, Hye-Ryeon;Park, Mi-Sook;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.16 no.1
    • /
    • pp.107-116
    • /
    • 2013
  • In the implementation of a P300 speller, rows and columns paradigm (RCP) is most commonly used. However, the RCP remains subject to adjacency-distraction error and double-flash problems. This study suggests a novel P300 speller stimuli presentation-the sub-block paradigm (SBP) that is likely to solve the problems effectively. Fifteen subjects participated in this experiment where both SBP and RCP were used to implement the P300 speller. Electroencephalography (EEG) activity was recorded from Fz, Cz, Pz, Oz, P3, P4, PO7, and PO8. Each paradigm consisted of a training phase to train a classifier and a testing phase to evaluate the speller. Eighteen characters were used for the target stimuli in the training phase. Additionally, 5 subjects were required to spell 50 characters and the rest of the subjects were to spell 25 characters in the testing phase. Classification accuracy results show that average accuracy was significantly higher in SBP as of 83.73% than that of RCP as of 66.40%. Grand mean event-related potentials (ERPs) at Pz show that positive peak amplitude for the target stimuli was greater in SBP compared to that of RCP. It was found that subjects tended to attend more to the characters in SBP. According to the participants' ratings on how comfortable they were with using each type of paradigm on 7-point Likert scale, most subjects responded 'very difficult' in RCP while responding 'medium' and 'easy' in SBP. The result showed that SBP was felt more comfortable than RCP by the subjects. In sum, the SBP was more correct in P300 speller performance as well as more convenient for users than the RCP. The actual limitations in the study were discussed in the last part of this paper.

  • PDF

User Centered Interface Design of Web-based Attention Testing Tools: Inhibition of Return(IOR) and Graphic UI (웹 기반 주의력 검사의 사용자 인터페이스 설계: 회귀억제 과제와 그래픽 UI를 중심으로)

  • Kwahk, Ji-Eun;Kwak, Ho-Wan
    • Korean Journal of Cognitive Science
    • /
    • v.19 no.4
    • /
    • pp.331-367
    • /
    • 2008
  • This study aims to validate a web-based neuropsychological testing tool developed by Kwak(2007) and to suggest solutions to potential problems that can deteriorate its validity. When it targets a wider range of subjects, a web-based neuropsychological testing tool is challenged by high drop-out rates, lack of motivation, lack of interactivity with the experimenter, fear of computer, etc. As a possible solution to these threats, this study aims to redesign the user interface of a web-based attention testing tool through three phases of study. In Study 1, an extensive analysis of Kwak's(2007) attention testing tool was conducted to identify potential usability problems. The Heuristic Walkthrough(HW) method was used by three usability experts to review various design features. As a result, many problems were found throughout the tool. The findings concluded that the design of instructions, user information survey forms, task screen, results screen, etc. did not conform to the needs of users and their tasks. In Study 2, 11 guidelines for the design of web-based attention testing tools were established based on the findings from Study 1. The guidelines were used to optimize the design and organization of the tool so that it fits to the user and task needs. The resulting new design alternative was then implemented as a working prototype using the JAVA programming language. In Study 3, a comparative study was conducted to demonstrate the excellence of the new design of attention testing tool(named graphic style tool) over the existing design(named text style tool). A total of 60 subjects participated in user testing sessions where their error frequency, error patterns, and subjective satisfaction were measured through performance observation and questionnaires. Through the task performance measurement, a number of user errors in various types were observed in the existing text style tool. The questionnaire results were also in support of the new graphic style tool, users rated the new graphic style tool higher than the existing text style tool in terms of overall satisfaction, screen design, terms and system information, ease of learning, and system performance.

  • PDF

A Study on the Necessity of Verification and Certification System of Inspection and Diagnostic Equipment for Infrastructure using Advanced Technologies (첨단 시설물 점검 및 진단장비 검·인증제도 도입 필요성에 대한 연구)

  • Hong, Sung-Ho;Kim, Jung-Gon;Cho, Jae-Young;Kim, Twae-Hwan
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.163-177
    • /
    • 2020
  • Purpose: While it is very important to maintain facilities recently, the introduction and its application of high technology in the facility maintenance industry has increased. It is necessary for high technology to secure reliability through the verification and certification system of diagnostic equipment to have an effective impact in the field, but there is difference between the industry's perspective and realistic level of technology apart from social demand for the system of the system. This paper dealt with the introduction of a verification and certification system for rational facility diagnostic equipment with the opinion survey on managers about the current situation. Method: Survey is carried out targeting managers in the maintenance and construction regarding the necessity and urgency of introducing a verification and certification system to promote the introduction and its application of high technology of diagnostic equipment and facility inspection. Also, the introduction to a verification and certification system was reviewed for advanced facility diagnostic equipment through foreign research about similar systems and comparative analysis of similar systems related to the certification of 21 domestic equipment. Result: It showed that, regarding the application of high technology, it is necessary for most managers to introduce high technology such as drones, robots, etc., in the maintenance industry, and when high technology is introduced, it will have a considerable effect in the field. On the other hand, the current technology level in Korea is relatively low, so it turned out to take a certain amount of time for the application of technology. Also, it was found that the management of reliable facility diagnostic equipment will be possible through the introduction of the verification and certification system for facility diagnosis equipment. Meanwhile, the survey is conducted on similar systems about foreign and domestic diagnosis and measuring equipment, etc., but there is no system to verify and certify equipment applied with high technology directly to facility diagnosis maintenance. However, because Japan has a system of verifying the performance of diagnostic equipment and South Korea has 21 similar inspection and diagnostic equipment certification systems among 186 certification systems, it is considered to be possible to design systems which utilize them. Conclusion: According to the managers' opinion, it seems that the introduction of the system supporting the application of 4th industrial technology for the equipment and the use of the equipment with high reliability has sufficient validity. However, because our high technology level is undervalued compared to the urgency, the system for checking high technology facilities and certifying diagnostic equipment should be to be implemented in form of escalation considering technical use and verification level. Apart from the introduction of the verification and certification system, it is necessary for special investment, support and efforts to promote advanced facility diagnostic equipment.

Wildfire Severity Mapping Using Sentinel Satellite Data Based on Machine Learning Approaches (Sentinel 위성영상과 기계학습을 이용한 국내산불 피해강도 탐지)

  • Sim, Seongmun;Kim, Woohyeok;Lee, Jaese;Kang, Yoojin;Im, Jungho;Kwon, Chunguen;Kim, Sungyong
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_3
    • /
    • pp.1109-1123
    • /
    • 2020
  • In South Korea with forest as a major land cover class (over 60% of the country), many wildfires occur every year. Wildfires weaken the shear strength of the soil, forming a layer of soil that is vulnerable to landslides. It is important to identify the severity of a wildfire as well as the burned area to sustainably manage the forest. Although satellite remote sensing has been widely used to map wildfire severity, it is often difficult to determine the severity using only the temporal change of satellite-derived indices such as Normalized Difference Vegetation Index (NDVI) and Normalized Burn Ratio (NBR). In this study, we proposed an approach for determining wildfire severity based on machine learning through the synergistic use of Sentinel-1A Synthetic Aperture Radar-C data and Sentinel-2A Multi Spectral Instrument data. Three wildfire cases-Samcheok in May 2017, Gangreung·Donghae in April 2019, and Gosung·Sokcho in April 2019-were used for developing wildfire severity mapping models with three machine learning algorithms (i.e., Random Forest, Logistic Regression, and Support Vector Machine). The results showed that the random forest model yielded the best performance, resulting in an overall accuracy of 82.3%. The cross-site validation to examine the spatiotemporal transferability of the machine learning models showed that the models were highly sensitive to temporal differences between the training and validation sites, especially in the early growing season. This implies that a more robust model with high spatiotemporal transferability can be developed when more wildfire cases with different seasons and areas are added in the future.

Development of Rapid Analytical Method of Forbidden Medicines in Dietary Supplements Using LC-ESI-Tandem MS (LC-ESI-tandem MS를 이용한 기능성표방식품 중 부정유해물질 신속검사체계 개발)

  • Kim, Hee-Yun;Jang, Young-Mi;Joo, Hyun-Jin;Jung, Young-Hyun;Lee, Myoung-Sook;Park, Jong-Seok;Lee, Kwang-Ho;Lee, Hwa-Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.372-379
    • /
    • 2007
  • A high-performance liquid chromatography-electrospray ionization (HPLC-ESI) tandem MS was developed for the rapid and simultaneous determination of forbidden medicines in dietary supplements. Thirteen medicinal components such as PDE-5 inhibitors and their analogues, and the newly identified dimethylsildenafil and xanthoanthrafil, were included in this study. After tentative standardization of molecular ions in both polarities using thirteen references on the mass spectrometer, with ESI-continuous infusion via the syringe pump method, the relative intensity of the ions present in the resulting spectra was quantitatively compared. From the results, the ion mode was selected depending on each reference's characteristics. A HPLC method coupled with the ESI mode was developed considering the matrix effect and interference depending on the type of sample. The validation test of the developed method was followed by carrying out precision, accuracy, recovery, sensitivity and linearity, etc. The method showed sufficiently high sensitivity, reproducibility, and specificity, and produced 4 times faster results when compared with the existing HPLC/UV method for the determination of forbidden compounds in dietary supplements.