• Title/Summary/Keyword: 섬유 개수

Search Result 51, Processing Time 0.024 seconds

Fiber Orientation Impacts on the Flexural Behavior of Steel Fiber Reinforced High Strength Concrete (섬유의 방향성이 강섬유 보강 초고강도 콘크리트의 휨거동 특성에 미치는 영향)

  • Kang, Su-Tae;Kim, Yun-Yong;Lee, Bang-Yun;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.731-739
    • /
    • 2008
  • To evaluate the fiber orientation characteristics and estimate its effect on the flexural strength of steel fiber reinforced ultra high strength concrete with directions of concrete placing, we developed an image processing technique and carried out the flexural test to quantify the effect of fiber orientation characteristics on the flexural strength as well. The image processing technique developed in this study could evaluate quantitatively the fiber orientation property by the use of dispersion coefficient, the number of fibers in a unit area, and fiber orientation. It was also found that the fiber orientation characteristics were dependent on the direction of concrete placing. Fiber orientation characteristic was revealed to strongly affect the ultimate flexural strength, while hardly affecting the first cracking strength. Theoretical model for flexural strength was applied to compare with test results, which exhibited a good agreement.

Correlation Between Flexural Toughness and Cracking Characteristics of Micro-fiber Reinforced Mortar According to Fiber Contents (마이크로 섬유보강 모르타르의 휨 인성과 균열 특성의 상관관계)

  • Shin, Kyung-Joon;Jang, Kyu-Hyou;Kim, Eui Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.249-257
    • /
    • 2008
  • Various methods have been used to reinforce the cementitious material such as mortar and concrete that have weak tensile strength. Major reinforcing method is to mix matrix with fibers which have strong tensile strength. Recently, micro-fiber reinforced mortar has been studied which removes coarse aggregate and uses micro-fiber with small diameter in order to homogenize the matrix properties and maximize the performance of fiber. Performance of micro-fiber reinforced mortar showing multiple cracking behavior is hardly represented only by the flexural toughness. Therefore, This paper reports the cracking behavior as well as mechanical behavior for various mixtures which have different fiber type and mixture proportions to find the proper parameter representing the cracking characteristic. Correlations between flexural toughness and various cracking characteristics such as cracking area, width and number are explored. As a result, it is found that flexural toughness, volume of fiber and number of cracks are suitable for representing the characteristics of micro-fiber reinforced mortar.

Realistic Prediction of Post-Cracking Behaviour in Synthetic Fiber Reinforced Concrete Beams (합성섬유보강 콘크리트 보의 균열 후 거동 예측)

  • 오병환;김지철;박대균;원종필
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.900-909
    • /
    • 2002
  • Fibers play a role to increase the tensile strength and cracking resistance of concrete structures. The post cracking behavior must be clarified to predict cracking resistance of fiber reinforced concrete. The purpose of this study is to develop a realistic analysis method for the post cracking behavior of synthetic fiber reinforced concrete members. For this purpose, the cracked section is assumed to behave as a rigid body and the pullout behavior of single fiber is employed. A probabilistic approach is used to calculate effective number of fibers across crack faces. The existing theory is compared with test data and shows good agreement. The proposed theory can be efficiently used to describe the load-deflection behavior, moment-curvature relation, load-crack width relation of synthetic fiber reinforced concrete beams.

Comparsions for Flexural Performance of Amorphous Steel Fiber Reinforced Concrete (비정질강섬유보강콘크리트의 휨성능 비교분석)

  • Kim, Byoung-Il;Lee, Sea-Hyun
    • Resources Recycling
    • /
    • v.24 no.3
    • /
    • pp.66-75
    • /
    • 2015
  • The flexural performance of amorphous steel fibers having environmental and economy benefits due to relatively short manufacturing process were evaluated as well as that of hooked steel fibers by varing fiber length and volume fraction. Fiber lengths were 10 mm, 20 mm, 30 mm and fiber volume fractions were varied from 0.3% to 1.2%. Test results with flexural performance showed that mixing design needs to be careful because of relatively high volume of amorphous steel fiber compared to hooked steel fibers. High flexural strength was obtained from both longer fiber length and higher volume fraction. Residual strength and toughness of amorphous steel fiber were similar to that of hooked steel fiber, even though rapid dropping of applied load right after concrete matrix breaking. It can be judged that relatively high ability of energy dissipation around first cracking area relatively overcome rapid dropping of loading.

Tensile Characteristics of High-Ductile Cementless Composite According to Aspect Ratio of Fiber (섬유의 형상비에 따른 고연성 무시멘트 복합재료의 인장특성)

  • Choi, Jeong-Il;Park, Se Eon;Kang, Su-Tae;Oh, Sungwoo;Lee, Bang Yeon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.160-166
    • /
    • 2018
  • The purpose of this study is to investigate experimentally the effects of aspect ratio of polyethylene fiber on the compressive strength and tensile behavior of alkali-activated cementless composite. Two mixtures were determined according to aspect ratio values of polyethylene fibers, and the compressive strength and tension tests were performed. Test results showed that the effect of aspect ratio of fiber on the compressive strength was negligible and the tensile strength, ductility, and number of cracks of the mixture including the fiber with high aspect ratio were higher than those of the mixture including the fiber with low aspect ratio. On the other hand, the crack spacing and crack width were low in the mixture including the fiber with high aspect ratio.

Tensile Deformation Characteristics of ECC Predicted with a Modified Fiber Bridging Curve (수정된 섬유 가교 특성을 고려한 ECC의 인장변형특성)

  • Kim, Jeong-Su;Lee, Bang-Yeon;Kim, Jin-Keun;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.541-548
    • /
    • 2009
  • A theoretical prediction model of fiber bridging curve was established based on the assumption that fibers are uniformly distributed on the crack surface. However, the distance between fibers and their orientation with respect to crack surface can greatly affect the prediction of fiber bridging curve. Since, the shape of fiber bridging curve is a critical factor for predicting the tensile stress-strain relationship of ECC, it is expected that the assumption of uniform distribution of fiber may cause a significant error when predicting the tensile behavior of ECC. To overcome this shortcoming, a new prediction method of stress-strain relation of ECC is proposed based on the modified fiber bridging curve. Only effective fibers are taken into account considering the effects of their orientation and distance between them. Moreover, the approach for formulating the tensile stress-strain relation is discussed, where a procedure is presented for obtaining important parameters, such as the first crack strength, the peak stress, the displacement at peak stress, tensile strain capacity, and the crack spacing. Subsequent uniaxial tensile tests were performed to validate the proposed method. It was found that the predicted stress-strain relations obtained based on the proposed modified fiber bridging curve exhibited a good agreement with experimental results.

Anti Photoaging Effects of Hyaluronic Acid following Oral Administration in SKH-1 Hairless Mice (SKH-1 Hairless Mice에서의 히알루론산 경구 투여를 통한 피부 광노화 개선 효과)

  • Lee, Sung-jin;Seo, YoonHee;Yun, Min-kyu;Yu, Heui-jong;Choe, Soo-Young
    • The Korean Journal of Food And Nutrition
    • /
    • v.28 no.6
    • /
    • pp.941-946
    • /
    • 2015
  • Photoaging is the main extrinsic aging factor that is induced due to UVB. Many studies have revealed that application of hyaluronic acid to the skin is effective in healing photoaging. However, the effect of hyaluronic acid through oral administration is unclear. The aim of this research was to investigate the effect on skin photoaging after oral administration of hyaluronic acid. During a ten week study, hyaluronic acid was fed to hairless mice, which were illuminated by UV radiation. After ten weeks, wrinkle indicator and histological changes were determined. Compared with the control group, the sample group had a decrease in wrinkle depth, thickness, and number. Especially, the HA 160 mg/kg group had a similar value of wrinkle depth ($19.44{\pm}0.75{\mu}m$), number ($654.00{\pm}98.34$), and thickness ($1.35{\pm}0.08mm$), when compared with the RA (retinoic acid) group ($19.28{\pm}0.95{\mu}m$, $653.57{\pm}83.54$, and $1.34{\pm}0.07mm$ respectively). Also, the treated group showed improved elastosis and decreased collagen degradation resulting from UV irradiation. Thus, we can conclude that hyaluronic acid has a positive effect in improving skin photoaging induced by UV radiation. Hyaluronic acid therefore has the potential to be an ingredient in skin health function foods.

Evaluation of Shear Strength of Perfobond Rib in Ultra High Performance Concrete (초고성능 콘크리트에 대한 Perfobond Rib 전단연결재 거동 평가)

  • Kang, Jae-Yoon;Jung, Woo-Tai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.5015-5020
    • /
    • 2015
  • Push-out test is performed on perfobond shear connectors applying ultra high performance concretes with compressive strength higher than 80 MPa to evaluate their shear resistance. The test variables are chosen to be the diameter and number of dowel holes and, the change in the shear strength of the perfobond rib connector is examined with respect to the strength of two types of UHPC: steel fiber-reinforced concrete with compressive strength of 180 MPa and concrete without steel fiber with compressive strength of 80 MPa. The test results reveal that higher concrete strength and larger number of holes increased the shear strength, and that higher increase rate in the shear strength was achieved by the dowel action.

Crack Initiation and Temperature Variation Effects on Self-sensing Impedance Responses of FRCCs (FRCCs의 자가센싱 임피던스 응답에 미치는 균열 발생 및 온도 변화 영향성)

  • Kang, Myung-Soo;Kang, Man-Sung;Lee, Han Ju;Yim, Hong Jae;An, Yun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.69-74
    • /
    • 2018
  • Fiber-Reinforced Cementitious Composites (FRCCs) have electrical conductivity by inserting reinforced conductive fibers into a cementitious matrix. Such characteristic allows us to utilize FRCCs for crack monitoring of a structure by measuring electrical responses without sensor installation. However, the electrical responses are often sensitively altered by temperature variation as well as crack initiation. The temperature variation may disturb crack detection on the measured electrical responses. Moreover, as sensing probes for measuring electrical reponses increase, undesired contact noises are often augmented. In this paper, a self-sensing impedance circuit is specially designed for reducing the number of sensing probes. The crack initiation and temperature variation effects on the self-sensing impedance responses of FRCCs are experimentally investigated using the self-sensing impedance circuit. The experiment results reveal that the electrical impedance response are more sensitively changed due to temperature variation than crack initiation.

Study of Mechanical Properties and Porosity of Composites by Using Glass Fiber Felt (유리섬유 부직포 사용에 따른 복합재의 기공률 및 물성에의 영향 분석)

  • Lee, Ji-Seok;Yu, Myeong-Hyeon;Kim, Hak-Sung
    • Composites Research
    • /
    • v.35 no.1
    • /
    • pp.42-46
    • /
    • 2022
  • In this study, when the carbon fiber composite was manufactured, the correlation between the porosity and mechanical properties according to the number of glass fiber felts laminated together and the stacking sequence was confirmed. The carbon fiber composite was manufactured by stacking glass fiber felts, which are highly permeable materials, and using vacuum assisted resin transfer molding (VARTM). Porosity was measured by photographing the cross-section of the specimen with an optical microscope and then using porosity calculation code of MATLAB, and mechanical properties were measured for tensile strength, modulus by tensile test. Furthermore, Pearson correlation coefficient between porosity and mechanical properties was calculated to confirm the correlation between two variables. As a result, the number of glass fiber felt increased and the distance from the center of laminated composites increased, the porosity increasing were confirmed. In addition, tensile strength/modulus showed a weak positive correlation with porosity. Also, in order to confirm the effect of only porosity on tensile strength and modulus, mechanical properties calculated by CLPT (Classical Laminate Plate Theory) and experimental values were compared, and the difference in tensile strength showed a strong positive correlation with porosity and the difference in modulus showed a weak positive correlation with porosity.