• Title/Summary/Keyword: 설정압

Search Result 189, Processing Time 0.02 seconds

Development of Device Measuring Real-time Air Flow in Greenhouse (온실 공기유동 계측 시스템 개발)

  • Noh, Jae Seung;Kwon, Jinkyoung;Kim, Yu Yong
    • Journal of Bio-Environment Control
    • /
    • v.27 no.1
    • /
    • pp.20-26
    • /
    • 2018
  • This study was conducted to develop a device for measuring the air flow by space variation through monitoring program, which acquires data by each point from each environmental sensor located in the greenhouse. The distribution of environmental factors(air temperature, humidity, wind speed, etc.) in the greenhouse is arranged at 12 points according to the spatial variation and a large number of measurement points (36 points in total) on the X, Y and Z axes were selected. Considering data loss and various greenhouse conditions, a bit rate was at 125kbit/s at low speed, so that the number of sensors can be expanded to 90 within greenhouse with dimensions of 100m by 100m. Those system programmed using MATLAB and LabVIEW was conducted to measure distributions of the air flow along the greenhouse in real time. It was also visualized interpolated the spatial distribution in the greenhouse. In order to verify the accuracy of CFD modeling and to improve the accuracy, it will compare the environmental variation such as air temperature, humidity, wind speed and $CO_2$ concentration in the greenhouse.

Analysis of Groundwater Flow into Underground Storage Caverns by Using a Boundary Element Model (경계요소모형을 이용한 지하 저장공동의 지하수 유입량 분석)

  • Chung, Il-Moon;Lee, Jeong-Woo;Cho, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.7 s.156
    • /
    • pp.537-544
    • /
    • 2005
  • For the proper management of high pressurized gas storage caverns, analysis of groundwater flow field and inflow quantity according to the groundwater head, gas storage pressure and water curtain head should be performed. The finite element method has been widely used for the groundwater flow analysis surrounding underground storage cavern because it can reflect the exact shape of cavern. But the various simulations according to the change of design factors such as the width of water curtain, shape of cavern etc. are not easy when elements were set up. To overcome these limitations, two dimensional groundwater flow model is established based on the boundary element method which compute the unknown variable by using only the boundary shape and condition. For the exact computation of drainage rate into cavern, the model test is performed by using the exact solution and pre-developed finite element model. The test result shows that the model could be used as an alternative to finite element model when various flow simulations are needed to determine the optimizing cavern shape and arrangement of water curtain holes and so forth.

Development of Decompressed Dryer for Mushroom (버섯의 감압건조기 개발)

  • 김영민;김유호;조영길;최희석;조광환
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.267-272
    • /
    • 2003
  • 본 연구에서는 버섯의 건조시간을 줄여 건조 후 버섯의 품질을 향상시키기 위하여 버섯의 감압건조기를 개발하였으며 연구 결과는 다음과 같다. 가. 버섯의 감압건조기의 시작기를 제작하였고, 시작기의 구조는 건조실, 감압블로워, 흡ㆍ배기구 솔레노이드 밸브, 제습장치, 송풍기, 전기히터로 구성되어 있으며, 건조실의 내부 압력이 표준대기압-900hPa, 열풍온도는 상온에서 5$0^{\circ}C$까지 조절할 수 있도록 제작하였다. 나. 시작기를 이용하여 표고버섯을 대상으로 건조특성시험을 실시한 결과, 열풍온도 5$0^{\circ}C$, 건조실 내부압력 900-940hPa에서 건조시간은 11.5h으로 대기압과 비교하여 6.5h 단축되는 것으로 나타났다. 또한, 건조 전ㆍ후의 색차, 수축률, 복원률의 품위가 우수한 것으로 나타났으며 F-test 유의성 검증 결과, 5%의 유의수준에서 갓주름의 색차, 갓직경의 수축률, 복원률에서 유의차가 있는 것으로 나타났다. 다. 열풍온도 5$0^{\circ}C$, 건조실 내부압력 900-940hPa로 표고버섯과 아가리쿠스에 대하여 건조성능시험을 실시한 결과, 표고버섯의 경우 건조시간은 13h으로 열풍식 농산물 건조기와 비교하여 건조시간이 4.5h 단축되는 것으로 나타났으며, 아가리쿠스의 경우 건조시간이 17.5h로 나타났다. 라. 성능시험 결과, 시작기가 열풍식 농산물건조기와 비교하여 건감률, 색택, 수축률, 복원률 등의 품위가 전반적으로 우수한 것으로 나타났다. 마. 시작기의 건조비용을 분석한 결과, 건조시간은 단축되었지만 시설투자비가 높아 건조비용이 표고버섯의 경우 2,461원/kg으로 열풍식 농산물건조기 보다 13% 높은 것으로 나타났지만, 추후 고품질 건조버섯 생산을 위한 기초자료로 활용이 가능할 것으로 판단된다.라갈수록 낮은 온도분포를 나타내고 있는 것은 상부에는 외부공기가 유입되면서 온도가 떨어지는 반면 하부에는 외부공기 유입이 적기 때문으로 사료된다. 또한 열풍실의 길이방향 위치별 온도 분포에서도 같은 현상으로 나타났고, 버너쪽과 송풍기쪽의 온도편차는 나타나지 않아 균일 건조를 기대할 수 있다. 마. 열풍온도를 45$^{\circ}C$로 설정하고 조사거리와 방사체 길이를 각각 119, 1,470mm로 하여 벼의 건조성능시험을 열풍건조기(대비구)와 비교시험 결과 시험구에서 건감률, 건조소요에너지가 각각 0.58%(w.b.), 470kcal/kg - water로 대비구보다 각각 건감율은 23% 높았고, 건조소요에너지는 2%의 절감되었다. 바. 건조기에서 발생되는 소음은 버너쪽 근처에서는 대비구 94.12㏈의 87%에 불과하였으나, 거리가 멀어질수록 차이는 크지 않았다. 이것은 버너에서 멀어질수록 외부적인 요인이 소음에 영향을 미쳤기 때문인 것으로 생각된다. 사. 시작기와 대비구간의 경제성에서 시작기의 구입가격이 20% 비싸기 때문에 시간당 고정비가 높았으나, 건조성능이 우수하여 건조비용이 69,350원/톤으로 대비구보다 14% 절감되는 것으로 나타났다.작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간을 연장시키는 경향을 보이며 큰 자기폭풍일수록 현저했다. 주상에서 관측된 이러한 특성은 서브스톰 확장기 활동이 자기폭풍의 발달과 밀접한 관계가 있음을 시사한다.se that were all

  • PDF

Radiation Dose and Image Evaluation for Position Change in Low Extremity Teleography (하지전신계측검사에서 자세의 변화에 따른 방사선량 및 영상평가)

  • Kim, Yeongcheon;Song, Jongnam;Choi, Namgil;Jeong, Yeon;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.409-415
    • /
    • 2014
  • In this study, radiation doses of major organs in various postures in lower extremity teleography were measured and compared to investigate the utility of the test methods. Ten adult males who underwent lower extremity teleography at a tube voltage of 73 kVp, tube current of 32 mAs, and SID of 180 cm. Using rando phantom, glass dosimeter was attached to the eye lens, thyroid gland, and genital gland to measure the radiation dose in each area 5 times in each anteroposterior posture and posteroanterior posture. The results were compared and analyzed through Paired T-test. The images from the anteroposterior posture and posteroanterior posture were evaluated through the blind test on a scale of 5. As a result, the posteroanterior method could reduce the dose than the anteroposterior posture method: less dose for the eye lens by 6%, thyroid gland by 6%, and genital gland by 26%. Since there was no significant difference in image evaluation, the posteroanterior posture is considered better than the anteroposterior posture in lower extremity teleography.

Numerical Modeling of Coupled Thermo-hydro-mechanical Behavior of MX80 Bentonite Pellets (MX80 벤토나이트 펠렛의 열-수리-역학적 복합거동 모델링)

  • Lee, Changsoo;Choi, Heui-Joo;Kim, Geon-Young
    • Tunnel and Underground Space
    • /
    • v.30 no.5
    • /
    • pp.446-461
    • /
    • 2020
  • Numerical simulations of CIEMAT column test in Spain are performed to investigate the coupled thermo-hydro-mechanical (THM) behavior of MX80 bentonite pellets using TOUGH2-FLAC3D. The heater power and injection pressure of water in the numerical simulations are identical to those in the laboratory test. To investigate the applicability of the thermo-hydraulic (TH) model used in TOUGH2 code to prediction of the coupled TH behavior, the simulation results are compared with the observations of temperature and relative humidity with time. The tendencies of the coupled behavior observed in the test are well represented by the numerical models and the simulator in terms of temperature and relative humidity evolutions. Moreover, the performance of the models for the reproduction and prediction of the coupled TH behavior is globally satisfactory compared with the observations. However, the calculated stress change is relatively small and slow due to the limitations of the simple elastic and swelling pressure model used in numerical simulations. It seems that the two models are insufficient to realistically reproduce the complex coupled THM behavior in the bentonite pellets.

An Experimental Study on Pumpability Characteristics of High Strength Concrete Mixed Polymix (폴리믹스 혼입 고강도 콘크리트의 펌프압송 성상에 관한 실험적 연구)

  • Lee, Joo-Ho;Moon, Hyung-Jae;Kim, Jeong-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.509-516
    • /
    • 2012
  • The aims of this research is to develop a fire resistant admixture to enhance high-pressured pumping of high-strength concrete (HSC) with a compressive strength of 60~80 MPa. Generally, the efficiency of HSC high-pressured pumping is dramatically reduced due to entanglement of short fibers added to prevent fire spalling. Therefore, the fire resistant admixture that can facilitate pumping of fire resistant HSC is urgently needed presently. The fire resistant HSC mix is comprised of Polypropylene fiber, Nylon fiber and Polymer powder. The test results showed that the slump-flow was improved by approximately 70% of the HSC without fire resistant admixture. However, the air void content was increased slightly due to the addition. The standard design compressive strength at 28-days was satisfied, while its flexural strength was similar to the concrete without the admixture. Since the flexural strength was 12~15% of its compressive strength, the general trend of flexural to compressive strength ratio in normal concrete was maintained. Even though its elastic modulus was decreased by adding the admixture, the study results showed that the concrete can be used for construction since all of the test results exceeded the code requirements.

LPG Cylinder Leak Experiment from Multiple Leak Scenarios (누출종류에 따른 LP가스용기 누출량 실증 실험)

  • Lee, Minkyung;Lee, Kang-Ok;Kim, Young Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.61-66
    • /
    • 2019
  • Unlike NG supplied through pipes, LPG is mainly used for independent storage of cylinders or small storage tanks. As LPG is widely used in islands and underdeveloped areas, accidents due to neglect of safety management are high. Houses and businesses that have LPG accidents are likely to be damaged due to relatively high population density. Therefore, the necessity of strengthening the safety management of LPG is constantly raised. Accordingly, in 1996, Korea Gas Safety Corporation conducted an LPG leak test. In this study, based on the 96-year experiment, the gas leakage measurement of LPG vessels was conducted by adding several conditions such as outside temperature and pipe condition. Through this, the trend of leakage for various scenarios of LPG leakage was examined. In the case of a gas leak, when the article which may affect the pressure such as a regulator is not connected, the leakage amount is greatly changed by the outside air temperature, and when the regulator is fastened, the influence of the outlet pressure is large. It is expected that the experiment can be used as basic data for determining gas accidents and leakages that may occur later.

Establishing the Concept of Buffer for a High-level Radioactive Waste Repository: An Approach (고준위폐기물처분장의 완충재 개념 도출: 접근방안)

  • Lee, Jae Owan;Lee, Minsoo;Choi, Heuijoo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.4
    • /
    • pp.283-293
    • /
    • 2015
  • The buffer is a key component of the engineered barrier system in a high-level radioactive waste (HLW) repository. The present study reviewed the requirements and functional criteria of the buffer reported in literature, and also based on the results, proposed an approach to establish a buffer concept which is applicable to an HLW repository in Korea. The hydraulic conductivity, radionuclide-retarding capacity (equilibrium distribution coefficient and diffusion coefficient), swelling pressure, thermal conductivity, mechanical properties, organic carbon content, and illitization rate were considered as major technical parameters for the functional criteria of the buffer. Domestic bentonite (Ca-bentonite) and, as an alternative, MX-80 (Na-bentonite) were proposed for the buffer of an HLW repository in Korea. The technical specifications for those proposed bentonites were set to parameter values that conservatively satisfy Korea's functional criteria for the Ca-bentonite and Swedish criteria for the Na-bentonite. The thickness of the buffer was determined by evaluating the means of shear behavior, radionuclide release, and heat conduction, which resulted in the proper buffer thickness of 0.25 to 0.5 m. However, the final thickness of the buffer should be determined by considering coupled thermal-hydraulic-mechanical evaluation and economics and engineering aspects as well.

Study on Exposure Dose According to Change of Source to Image Distance and Additional Filter Using Abdomen Phantom (복부팬텀을 이용한 SID 변화와 부가필터 유무에 따른 피폭선량에 관한 연구)

  • Kim, Ki-Won;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.407-414
    • /
    • 2016
  • This study is to minimize the patient dose and maintain the image quality according to change of source to image receptor distance and applying additional filter. In this study, we used the DR system, the tissue-equivalent abdomen phantom and the aluminium filter. The exposure conditions were set to 80 kVp using AEC mode. The collimation size was $16{\times}16inch$. The exposure dose were measured 10 times when the SID was changed with 100, 110, 120 and 130 cm, respectively. The pirana 657 for dosimeter was located on center of radiation irradiation. The acquired images were analyzed by using the image J. In the results, the tube current was increased with increasing the SID but ESD was decreased with increasing the SID. The decrease of ESD attribute to use of filter that remove the photon of lower energy. In the histogram results using image J, there were differences between the ESD and the exposure conditions according to change of SID. However, there were not differences in histogram. Therefore, the exposure dose could reduced when set the longer SID. For pediatric exam, the exposure dose could reduced when used the aluminium filter.

The Evaluation of CR and DDR chest image using ROC analysis (ROC평가 방법을 이용한 CR과 DDR 흉부 영상의 비교)

  • Park, Yeon-Ok;Jung, Eun-Kyung;Park, Yeon-Jung;Nam, So-Ra;Jung, Ji-Young;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.25-30
    • /
    • 2007
  • ROC(Receiver Operating Characteristic)curve is the method that estimate detected insignificant signal from the human's sense of sight, it has been raised excellent results. In this study, we evaluate image quality and equipment character by obtaining a chest image from CR(Computed Radiography) and DDR(Direct Digital radiography) using the human chest phantom, The parameter of exposure for obtaining chest image was 120 kVp/3.2 mAs and the SID(Source to Image Distance) was 180cm. The images were obtained by CR(AGFA MD 4.0 General plate, JAPAN) and DDR(HOLOGIC nDirect Ray, USA). Using some pieces of Aluminum and stone for expressing regions, then attached them on the heart, lung and thoracic vertebrae of the phantom. 29 persons hold radiology degrees were participated in ROC analysis. As a result of the ROC analysis, TPF(true positive fraction) and FPF(false positive fraction) of DDR and CR are 0.552 and 0.474 and 0.629 and 0.405, respectively. By using the results, the ROC curve of CR has higher image quality than DDR. According to the theory, DDR has the higher image quality than CR in chest X-ray image. But, CR has the higher image quality than DDR. quality of DDR inserted the enhance board. The results confirmed that image post-processing is important element decipherment of clinical.

  • PDF