• Title/Summary/Keyword: 설정압

Search Result 189, Processing Time 0.026 seconds

Evaluation on Organ Dose and Image Quality by Changing kVp and Ion Chamber Combination while Taking Digital Chest Lateral Decubitus PA Projection (디지털 흉부 측와위 후전방향 검사 시 Ion chamber조합 설정과 관전압 변화에 따른 장기선량 및 화질 평가)

  • Lee, Jin-Soo;Park, Hyong-Hu
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.1
    • /
    • pp.316-323
    • /
    • 2015
  • In this study, we analyzed radiation dose and MTF with setting of Ion chamber and changing kVp so that we are able to suggest acquiring optimized diagnostic images and minimizing patient dose. we assumed right lateral decubitus position among chest decubitus projection and set 7 combination of Ion chamber. By changing kVp(100, 110, 120, 130kVp), we exposed x-ray five times respectively and calculated average value after measuring entrance dose. we input the entrance dose value to PCXMC Monte carlo simulation tool and calculated organ dose and effective dose. Then we did physical image evaluation with MTF for the purpose to compare image quality. As a result, the high kVp, entrance dose is reduced. As change of ion chamber, when selecting second ion chamber, both organ dose and effective dose were the lowest. In contrast, selecting first ion chamber was the highest. MTF is superior to set second Ion chamber and using 120 kVp. Consequently, when taking chest right lateral decubitus using Digital radiography, the optimized combination which have both reducing dose efficiently without declining image quality and aquring good qualified image is set 120 kVp and selecting second Ion chamber.

Research on Pitot-static Probe Heater Design for Aircraft (항공기 장착용 동정압 프로브의 열선 설계에 대한 연구)

  • Choi, In-Ho;Park, Yong-Min;Kim, Sung-Chan;Song, Jae-Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.488-491
    • /
    • 2011
  • 본 논문에서는 항공기에 장착되는 동정압 프로브의 열선 설계에 대한 내용이다. 항공기에 장착되는 동정압 프로브는 방빙/제빙 기능이 매우 중요하고 기본 설계 단계에 해석에 의해서 설계가 수행되어야 한다. 여기서는 동정압 프로브를 해석하기 위한 설정 조건과 해석 방법 및 해석결과에 대하여 기술하였다.

  • PDF

Pressure Differentials in the Elevator Lobby Depending on the Reference Pressures of the Pressurizing Dampers (급기가압 댐퍼의 설정 기준압에 따른 부속실 차압 특성 연구)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.12-17
    • /
    • 2007
  • This paper investigated pressure differentials in the elevator lobby depending on reference pressures of the pressurizing damper using FDS fire modeling. The results showed the temperatures and pressures in the contained fire room with small leak gaps can increase significantly. Setting reference pressure of the pressurizing dampers to 0 Pa can cause reduction of real pressure differentials and air velocity to resist smoke flow. This would cause smoke movement from fire room to elevator lobby which should be safe area for evacuation.

An Analytical Investigation of a Hydraulic Clutch System of Powershift Transmission (파워시프트 변속기 유압클러치시스템의 해석적 연구)

  • Lee, J.C.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • This study presents an analytical model of hydraulic clutch system of a power shift transmission to analyze pressure modulation characteristics. A typical hydraulic clutch system was modeled by using AMESim in which the parameters of major components were measured for simulation. Test apparatus was established using the components of power shift and power shuttle clutches with instrumental equipment. The results of simulation and experiment were so close that the proposed analytical model in this study was validated. However the cylinder model analogized clutch dynamics need to be improved in future study. The effects of parameters of orifice diameter, accumulator stroke and oil temperature on pressure modulation were analyzed respectively. The results of parameter sensitivity analysis show that modulation time and set pressure can be easily adjusted by changing parameter values. It is also found that the hydraulic clutch system used in this study is so susceptible to oil temperature that cooling equipment is necessary.

  • PDF

Analysis of the cause by Pre Exposure Tube Voltage and Actual Exposure Tube Voltage deviation in Mammography Examination (유방 촬영검사에서 사전조사 관전압과 실제조사 관전압 편차에 따른 원인 분석)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.79-85
    • /
    • 2017
  • The purpose of this study is to investigate the cause analysis according to the difference between the pre exposure tube voltage and actual exposure tube voltage in mammography in connection with breast pressure thickness, breast size and body mass index and to find the improvement. The study tracked 377 women age 40 and older among the mammography examiners conducted by the National Health Insurance Corporation. It was analyzed that breast pressure thickness, breast size and body mass index according to the difference between the pre exposure tube voltage and actual exposure tube voltage among the parameters of dose report been sent to the picture archiving communication system with reference to the image with cranio-caudal projection in mammography. As are result, it shows that the thicker the breast thickness, smaller the breast size and lower body mass index, the higher the difference of tube voltage. In conclusion, the minimum tube voltage of mammography machine should be reset in order to set the tube voltage according to breast pressure thickness and breast size that are suitable for our country in mammography, in addition, it was considered that radiologist should make an effort to reduce radiation exposure and make a good quality image with reducing the difference of mammography condition by making a correct exposure condition in case of examining the patients with thin breast pressure and small breast size.

Improved Image Quality and Radiation Dose Reduction in Liver Dynamic CT Scan with the Protocol Change (Liver CT 검사에서 프로토콜 변화에 따른 선량 감소와 영상의 질 개선에 관한 연구)

  • Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.107-114
    • /
    • 2015
  • The purpose is reducing radiation dose while maintaining of image quality in liver dynamic CT(LDCT) scan, by protocols generally used and the tube voltage set at a low level protocol compared to the radiation dose and image quality. The target is body mass index, 18.5~24 patients out of 40 patients who underwent the ACT(abdominal CT). Group A(tube voltage : 120kVp, SAFIRE strength 1) of 20 people among 40 people, to apply the general abdominal CT scan protocol, group B(tube voltage : 100kVp, apply SAFIRE strength 0~5) was 20 people, set a lower tube voltage. Image quality evaluation was setting a region of interest(ROI) in the liver parenchyma, aorta, superior mesenteric artery (SMA), celiac trunk, visceral fat of arterial phase. In the ROI were compared by measuring the noise, signal to noise ratio(SNR), contrast to noise ratio(CNR), CT number. In addition, qualitative assessments to evaluate two people in the rich professional experience in Radiology by 0-3 points. We compared the total radiation dose, dose length product(DLP) and effective dose, volume computed tomography dose index(CTDIvol). The higher SAFIRE in the tube voltage 100 kVp, noise is reduced, CT number was increased. Thus, SNR and CNR was increased higher the SAFIRE step. Compared with the tube voltage 120kVp, noise, SNR, CNR was most similar in SAFIRE strength 2 and 3. Qualitative assessment SAFIRE strength 2 is the most common SAFIRE strength 2 the most common qualitative assessment, if the tube voltage of 100kVp when the quality of the images better evaluated was SAFIRE strength 1. Dose was reduced from 21.69%, in 100kVp than 120kVp. In the case of a relatively high BMI is not LDCT scan, When it is shipped from the factory tube voltage is set higher, unnecessary radiation exposure when considering the reality that is concerned, when according to the results of this study, set a lower tube voltage and adjust the SAFIRE strength to 1 or 2, the radiation without compromising image quality amount also is thought to be able to be reduced.

3.2 kW Mono Block Type Portable X-ray Generator (모노탱크 탑재형 고주파 포터블 X-선 발생 장치)

  • Oh Junyong;Sung Kibong;Kim Hackseong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.430-434
    • /
    • 2004
  • 본 논문에서는 관전류 직접제어 방식을 채택한 3.2kW(80kV,40mA)급 최소형, 최경량 Portable X-선 장치를 제안한다 본 장치는 X-선 발생을 위한 고전압 발생 단에 모노탱크 블록 사용하였고, 고주파 고전압용 인버터에는 스위칭 전력소자로서 Mini block type의 MOS-FET를 채용, 80kHz로 스위칭 함으로서 고전압 변압기를 비롯한 고전압 발생부의 크기와 무게를 최소화하였다. X-ray Power의 출력이 높아짐에 따라, X-ray tube의 필라멘트 인버터의 출력용량 또한 증가되었다. 본 논문에서는 설정 관전류에 대한 정밀한 제어를 위하여 2단계 모드로 필라멘트 예열을 행하여 관전류 응답특성을 개선하였으며 제안한 휴대용 X-선 발생장치의 부하변동에 따른 X-선 관전압과 관전류의 개선된 특징을 실험파형을 통하여 입증하였다.

  • PDF

Mono Block Type Portable X-ray Generator (모노 블록형 휴대용 X-선 발생 장치)

  • Oh J.Y.;Sung K.B.;Park J.R.;Kim H.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.750-754
    • /
    • 2003
  • 본 논문에서는 X-선 관전류를 직접 검출하여 제어하는 2.4kW(80kv,30mA)급 최소형, 최경량 휴대용 X-선 발생 장치를 제안한다. 본 장치는 X-선발생을 위한 고전압 발생단에 모노탱크 블록 사용하였고, 고주파 고전압용 인버터에는 스위칭 전력소자로서 MOS-FET를 채용, 70kHz로 스위칭 함으로서 고전압 변압기를 비롯한 고전압 발생부의 크기와 무게를 최소화하였다. 또한, 설정 관전류에 대한 정밀한 제어를 위하여 2단계 모드로 필라멘트 예열을 행하여 관전류 응답특성을 개선하였으며 제안한 휴대용 X-선 발생장치의 부하변동에 따른 X-선 관전압과 관전류의 개선된 특징을 실험파형을 통하여 입증하였다.

  • PDF

Analysis of dynamic downpull force on underflow type floating gate (부력식 수문의 동적 하향력 분석)

  • Lee, Ji Haeng;Han, Il Yeong;Choi, Heung Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.78-78
    • /
    • 2018
  • 자동수문이란 설정된 관리수위 이하에서는 수문이 개방되지 않고, 유량이 증가하여 관리수위 이상이 되면 수문이 개방되어 관리수위까지 방류하게 되면 다시 수문이 닫히게 되어 자동으로 관리수위를 유지한다는 것을 의미한다. 이러한 연직 자동수문의 방류특성이 수동식 연직수문과 다른 점은 유량에 따라서 수문 개방고의 증감과 수문개폐가 자동으로 이루어진다는 것이다. 따라서 자동수문의 운영 중 수문개방고의 거동과 자동개폐 시점을 예측하는 것은 정밀한 수문설계를 위해 매우 중요하다. 수문 개방 시 흐름이 정지되어있다고 가정하면, 정수압 상태의 부력이론에 의한 부력수문의 개방고는 어렵지 않게 계산할 수 있다. 그러나, 흐름이 정지되어 있다가 수문의 하단으로 방류가 시작되면 수문 선단을 포함한 주변에 압력 차이로 인해 동수압 하중이 발생하게 되어 수문에 진동을 유발하고, 수문개방을 억제하는 힘이 발생하여 수문 운영에 큰 영향을 미친다. 본 연구에서는 부력식 수문의 모형실험을 통하여 정수압 상태의 부력이론에 의한 수문 개방율과 측정에 의한 수문 개방율을 비교하였으며, 압력계수를 이용하여 이론과 측정 수문 개방고의 차이는 동적하중에 의한 효과임을 확인하였다. 모형실험에서 측정된 자료와 수치모형 ANSYS - Fluent의 사용성을 검증하였고, 부력식 수문의 형상에 따른 동적하중을 분석하였다. 수문 형상비는 0.24~1.09로 설정하였고, 분석결과 부력식 수문은 수문 개방율이 커짐에 따라 압력계수는 감소하는 경향을 보였으며, 동적하중은 증가하는 경향을 보였다. 또한, 부력식 수문의 형상비에 따라서는 형상비가 증가함에 따라 동적하중이 감소하는 관계를 확인하였다.

  • PDF

Optimal Slit Length Limit of Tight Skirts in Movement and Physiological Response (동작에 따른 타이트 스커트 최소 적정 트임량과 생리적인 반응)

  • Kim, Hee-Eun;Lee, Jung-Sug
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.12
    • /
    • pp.1390-1396
    • /
    • 2003
  • 본 연구는 타이트 스커트의 트임의 개수가 왼쪽 옆선에 1개 있을 때와 왼쪽 옆선, 오른쪽 옆선에 각각 1개씩 모두 2개 있을 때 평지 보행, 계단 승강, 버스 승강 등과 같은 일상동작에 잘 적응할 수 있는 타이트 스커트의 적정 트임 길이를 설정하는 것을 목표로 하였다. 아울러 각 동작시의 트임 길이에 따른 생리적인 반응을 의복압, 산소 섭취량을 통해 알아보고자 하였다. 평균보폭은 4m 구간을 평상시대로 걸을 때의 발자국간 평균거리를 이용하였으며 국민표준체위조사보고서(1997)에 의한 평균체형을 가진 9명의 피험자를 정하였다. 스커트의 형태는 무릎길이인 타이트 스커트로 정하였다. 스커트의 트임은 왼쪽 옆선에 1개 있는 경우와 왼쪽 옆선, 오른쪽 옆선에 각각 1개씩 있는 경우의 2종류이다. 트임이 1개인 스커트는 2cm 간격으로, 트임이 2개인 스커트는 1cm 간격으로 트임 위치를 표시하여 길이를 조정하였다. 적정 트임 길이는 Likert 척도에 의한 만족도 평가로 측정하였으며 의복압은 air-bag system으로, 산소 섭취량은 Quark $B^2$ 으로 측정하였다. 본 연구의 결과는 다음과 같다. 1. 스커트의 최소 적정 트임 길이는 트임 1개일 때 평지 보행시 4cm, 계단 승강시 12cm ,버스 승강시 18cm이며, 트임 2개일 때 평지 보행시 2cm, 계단 승강시 8cm, 버스 승강시 15cm로 나타났다. 2. 의복압의 경우, 동일 트임 길이에서 트임 1개의 의복압이 트임 2개의 의복압보다 높았지만 트임 개수에 따른 전체 트임 길이로 보면 트임 1개의 의복압이 트임 2개의 의복압 보다 낮게 나타났다. 동작별로는 버스 승강의 의복압이 가장 높고 계단 승강, 평지 보행 순으로 낮아졌다. 3. 산소 섭취량의 경우, 동일 트임 길이에서 트임 1개와 트임 2개의 산소 섭취량은 거의 비슷하였다. 트임 개수에 따른 전체 트임 길이로 보면 트임 1개의 산소 섭취량이 트임 2개의 산소 섭취량보다 낮게 나타났다. 동작별로는 버스 승강의 산소 섭취량이 가장 높고 계단 승강, 평지 보행 순으로 낮아졌다.