Operational Characteristics of Wind Turbine Generator Systems in Hangwon Wind Farm (행원 풍력발전단지에서 풍력발전시스템의 운전특성)

  • Ko, Kyung-Nam;Kang, Mun-Jong;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • This paper reveals both the operational situation and the cause of the error occurred in wind turbine generator system of Hangwon wind farm in Jeju island. The four wind turbines were selected for this work, and the monitored period was for six months. Wind resource in the wind farm was analyzed, and the estimated energy production was compared with the actual energy production. As a result, with a decrease of system error, the estimated energy production was in good agreement with the actual energy production. The errors occurring in components such as gearbox and hydraulic motor affected the Availability of the wind turbine. Also, poor external conditions such as a strong wind, lightning and gust caused a standstill of wind turbines.

An Analysis of the Impact of Wind Power Generation on SMP (풍력발전이 SMP에 미치는 영향)

  • Ryu, Seung-Hyun;Um, Shin-Young;Kim, Su-Duk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.208-211
    • /
    • 2009
  • 제4차 전력수급기본계획(2008-2022)과 제3차 신 재생에너지 기술개발 및 이용.보급계획에 의거하여 전력산업기반기금을 통해 우선 구매되는 풍력발전이 계통한계가격(SMP, System Marginal Price)에 미치는 영향을 점검하였다. 제4차 전력수급기본계획(2008-2022)에서 향후의 전원설비건설계획과 전력수요를 참고하고, 제3차 신 재생에너지 기술개발 및 이용 보급계획에 의거, 풍력발전보급계획을 반영하였다. 발전변동비의 변화는 미래의 화석연료변동에 따를 것으로 보아 명목상승률 3%, 6%, 그리고 8%의 경우를 검토하였다. 현재는 풍력발전용량이 전체발전용량에 비해 미미해서 SMP에 큰 변화를 가져다주지 못하고 있지만 2014년에는 SMP가 결정되는 구간이 LNG발전기에서 유연탄발전기로 옮겨감에 따라 SMP차이가 최대 20.02[\/KWh](발전 비용 명목 상승률8%)에 달하다가 2020년에는 다시 0[\/KWh](발전비용 명목상승률8%)으로 줄어드는 것으로 분석되었다.

  • PDF

A study on load shedding considering wind power effect in Che-ju island (제주계통 연계선 고장 시 풍력을 고려한 부하차단 용량 계산에 관한 연구)

  • Hwang, Kyo-Ik;Chun, Yeong-Han
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.304-306
    • /
    • 2005
  • 풍력 발전에 대한 관심이 증대 되면서 우리나라도 제주도와 강원도를 중심으로 풍력에 대한 계통연계를 시도 하고 있다. 특히 제주도의 경우 풍속이 적절하여 현재 총 15.8MW 설비의 풍력 발전 설비를 갖고 있으며 높은 이용률을 보이고 있다. 2007년 까지 추가 건설 계획 중인 용량은 85MW로 계속적으로 설비를 확대 하고자 한다. 계획 중인 풍력 용량이 완공되면 제주도 전체 설비의 14%에 달하게 된다. 이런 용량의 증가는 풍력 발전기의 불규칙적인 특성상 제주도의 전력 시스템에 영향을 줄 것으로 보인다. 제주도는 연평균 전력의 30%정도를 내륙과의 연계 선에 의지하고 있어 현재도 5단계의 부하차단 시스템을 운영하고 있다. 따라서 본 논문에서는 풍력발전기의 갑작스런 출력 변동 시 계통에 미치는 영향을 분석하고 증대된 풍력 발전기에 의한 영향을 안정화하기 위한 적정 부하 차단량을 산정하고자 한다.

  • PDF

Failure Rate Calculation for the Reliability Evaluation of Distribution Transformers (배전변압기 신뢰성 평가를 위한 고장률 산출)

  • Song, Min Kook;Kim, Dong Hee
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1505-1506
    • /
    • 2015
  • 본 논문은 신뢰성 평가의 핵심을 이루는 고장률 계산을 통하여, 배전변압기의 정량적인 신뢰성 척도 산출에 대한 것이다. 배전변압기는 사용시간의 경과와 더불어 환경 조건 등 여러 가지 요인으로 그 성능이 서서히 열화되고 마침내 고장에 이르게 된다. 따라서 배전변압기의 신뢰성에 대한 적절한 평가 도구가 없으면 배전변압기 설비 운영에 대한 피드백이 체계적으로 이루어지지 못하게 된다. 이러한 문제점을 해결하기 위해 신뢰성 평가에 대한 정량적인 척도 산출이 필요하며, 이를 위해 본 연구에서는 배전변압기의 신뢰성 모형 설계를 수행하였다. 고장률 계산을 위해 일반적으로 널리 이용되는 확률론적 모델을 가정하였으며, 실제 운전 및 고장실적 데이터를 기반으로 한 배전변압기의 고장률을 산출하고, 이를 바탕으로 배전변압기의 수명 및 신뢰성 척도를 확보하였다.

  • PDF

Instrumented Indentation Technique: New Nondestructive Measurement Technique for Flow Stress-Strain and Residual Stress of Metallic Materials (계장화 압입시험: 금속재료의 유동 응력-변형률과 잔류응력 평가를 위한 신 비파괴 측정 기술)

  • Lee, Kyung-Woo;Choi, Min-Jae;Kim, Ju-Young;Kim, Kwang-Ho;Kwon, Dong-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.306-314
    • /
    • 2006
  • Instrumented indentation technique is a new way to evaluate nondestructive such mechanical properties as flow properties, residual stress and fracture toughness by analyzing indentation load-depth curves. This study evaluated quantitatively the flow properties of steels and residual stress of weldments. First, flow properties can be evaluated by defining a representative stress and strain from analysis of deformation behavior beneath the rigid spherical indenter and the parameters obtained from instrumented indentation tests. For estimating residual stress, the deviatoric-stress part of the residual stress affects the indentation load-depth curve, so that by analyzing the difference between the residual-stress-induced indentation curve and residual-stress-free curve, the quantitative residual stress of the target region can be evaluated. The algorithm for flow property evaluation was verified by comparison with uniaxial tensile test and the residual stress evaluation model was compared to mechanical cutting and ED-XRD results.

SPSA Approach to Image Reconstruction in Electrical Impedance Tomograhpy (전기 임피던스 단층촬영법에서 SPSA를 이용한 영상복원)

  • 김호찬;부창진;이윤준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.23-28
    • /
    • 2004
  • In EIT, various image reconstruction algorithms have been used in order to compute the internal resistivity distribution of the unknown object with its electric potential data at the boundary. Mathematically the EIT image reconstruction algorithm is a nonlinear ill-posed inverse problem. In this paper, a SPSA approach is proposed for the solution of the EIT image reconstruction. Results of numerical experiments of EIT solved by the SPSA approach are presented and compared to that obtained by the modified Newton-Raphson(mNR) method.

Determination of Maintenance Period and Failure Probability for Turbine Using Maintenance Record (터빈설비의 정비이력을 이용한 고장확률 예측 및 정비주기 설정에의 응용)

  • Song, Gee-Wook;Koo, Jae-Raeyang;Choi, Woo-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1325-1330
    • /
    • 2010
  • The breakdown of any critical component of a turbine results in the outage of power plants. Unexpected failure decreases equipment utilization and causes enormous economic losses. Currently, we conduct conservative preventive maintenance for a maintenance period that is proposed by a vendor. In the rapidly changing business environment, reliability-based maintenance is required in order to remain competitive and reduce maintenance costs while maintaining the reliability of equipment. In order to determine an appropriate maintenance period for guaranteeing reliability, we must determine the failure probability by carefully analyzing the failure history of the equipment. In this study, we created a database of failure history for power-plant turbines, predicted the best repair time using the Weibull function, and investigated how the appropriate maintenance cycle can be determined.

Fire Test of Old Type Interiors of Subway Vehicle in ISO 9705 Room (ISO 9708 룸 설비를 이용한 구형 지하철 내장재 화재시험)

  • Lee, Duck-Hee;Park, Won-Hee;Jung, Woo-Sung;Hwang, Jung-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.5
    • /
    • pp.481-487
    • /
    • 2010
  • A room scale fire test was done for interior materials from a subway vehicle installed within an ISO 9705 fire test room. The interior materials are the old ones which were made before the new fire safety guideline of subway vehicles. The output of ignition burner was increased in controlled steps to CEN/TS 45545-1. The objectives of this interior fire test are to assess the fire performance in terms of ignition and flame spread on interior lining materials and to provide data on an enclosure fires involving subway vehicle interior materials that grow to flashover. Temperatures, heat flux and heat release rate variations verse time of the test are measured. Heat release rate is compared with that of calculated by modified flaming area based summation method. These test results will be used for verification of CFD fire simulation of full subway vehicle.

Characteristics of fluorescent lamp back light controller using IGBT (IGBT를 이용한 형광등 백라이트 제어기 특성)

  • Ka, Chool-Hyun;Kim, Soon-Gi
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.38-41
    • /
    • 2005
  • IGBT를 이용한 형광등 백라이트 제어기를 설계 제작하여 특성 실험을 한 결과, 타 방식의 백라이트 제어기 비하여 고효율, 고역률, 고품질의 특성을 가지는 한편, 스위칭 시에 발생하는 피크 전류 및 노이즈로 인한 인접 전기전자기기에 영향을 미치지 않도록 함으로써 안정성이 뛰어나며, 또한 기존의 슬라이닥스를 이용한 전원장치를 대체하는 한편 원격제어를 손쉽게 구현할 수 있는 장점을 가지고 있다. 또한 본 제어기는 제로크로싱 동기를 채택하여 온 오프 시에 발생하는 피이크 전류를 방지함으로서 제품의 안전성을 극대화시킬 수 있는 장점을 가지고 있어 차후 산업용 전원 장치 및 각종 가변 전원을 필요로 하는 대상에도 광범위하게 응용될 수 있을 것이다.

  • PDF

수배전 시스템의 에너지 절약$\cdot$이용합리화 3. 액티브 콘덴서

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.264
    • /
    • pp.84-89
    • /
    • 1998
  • 지금까지 수전설비의 역률조정에는 진상콘덴서가 사용되었고 콘덴서뱅크의 투입-해별에 따라 Step 모양으로 제어하여, 역률 개선효과는 0.98$\~$0.97정도가 일반적이었다.그러나 자에너지(에너지 절약$\cdot$이용합리화)에 대한 관심이 높아지는 가운데, 부하기기에 대해서는 파워일렉트로닉스 기술을 이용한 인버터화 등에 의하여 자에너지화가 도모되고 있다. 또한 코제너레이션의 설치에 의한 설비 전체로서의 에너지의 유효활동도 이루어져, 역률조정에서도 변동이 적고 가능한 한 고역률을 유지할 것을 요망하고 있다. 또 자에너지화에 크게 기여하고 있는 인버터 등에서 발생하는 전기공해라고도 할 수 있는 고조파전류가 많이 발생하고, 이 고조파전류의 유입으로 진상콘덴서의 과열$\cdot$이음발생 등의 이상을 일으키는 경우가 최근에 많이 발생하고 있다. 이와 같은 배경에서 액티브필터 제어기술을 적용하여 전력용콘덴서를 사용하지 않는 무효전력보상장치인 액티브 콘덴서(active condenser)를 제품화하여 시장에 내놓았다. 액티브 콘덴서는-무효전류 연속제어에 의하여 전원역률을 1.0으로 유지 -고속응답성 -대용량 IGBT(Insulted Gate Bipolar transistor)소자의 채용에 의한 소형화 -고조파의 영향을 받지 않음 등 지금까지의 진상콘덴서에는 없는 우수한 장점이 있어, 자에너지와 고조파문제에 유효한 수단이 되고 있다.

  • PDF