• Title/Summary/Keyword: 설비용량

Search Result 713, Processing Time 0.028 seconds

Power Generation Cost Comparison of Nuclear and Coal Power Plants in Year 2001 under Future Korean Environmental Regulations -Sensitivity and Uncertainty Analysis- (미래의 한국의 환경규제여건에 따른 2001년도의 원자력과 석탄화력 발전단가비교 -민감도와 불확실도 분석-)

  • Lee, Byong-Whi;Oh, Sung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.18-31
    • /
    • 1989
  • To analyze the impact of air pollution control on electricity generation cost, a computer program was developed. POGEN calculates levelized discounted power generation cost including additional air pollution control cost for coal power plant. Pollution subprogram calculates total capital and variable costs using governing equations for flue gas control. The costs are used as additional input for levelized discounted power generation cost subprogram. Pollution output for Rue Gas Desulphurization direct cost was verified using published cost data of well experienced industrialized countries. The power generation costs for the year 2001 were estimated by POGEN for three different regulatory scenarios imposed on coal power plant, and by levelized discounted power generation cost subprogram for nuclear power. Because of uncertainty expected in input variables for future plants, sensitivity and uncertainty analysis were made to check the importance and uncertainty propagation of the input variables using Latin Hypercube Sampling and Multiple Least Square method. Most sensitive parameter for levelized discounted power generation cost is discount rate for both nuclear and coal. The control cost for flue gas alone reaches additional 9-11 mills/kWh with standard deviation less than 1.3 mills/kWh. This cost will be nearly 20% of power generation cost and 40% of one GW capacity coal power plant investment cost. With 90% confidence, the generation cost of nuclear power plant will be 32.6-51.9 mills/kWh, and for the coal power plant it will be 45.5-50.5 mills/kWh. Nuclear is favorable with 95% confidence under stringent future regulatory requirement in Korea.

  • PDF

Present Status of Hydrogen Refueling Station in KIER (KIER 수소충전소 구축 현황)

  • Seo, Dong-Joo;Seo, Yu-Taek;Seo, Yong-Seog;Park, Sang-Ho;Roh, Hyun-Seog;Jeong, Jin-Hyeok;Yoon, Wang-Lai
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.21-24
    • /
    • 2006
  • 수소의 소규모 분산 생산 기술은 본격 적 인 수소 인프라가 도입되기 전에 연료전지 자동차의 수소 충전용이나 분산 발전형 연료전지의 수소 공급을 위해 필요하다. 생산 용량은 수소 기준으로 $20{\sim}100 Nm^3/hr$ 정도로 현재로선 천연가스의 수증기 개 질법이 가장 경제적인 공정으로 알려져 있다. 소규모 생산에 따른 열효율 저하를 줄이 기 위해 단위 공정들이 통합된 컴팩트 개질 시스템의 개발이 필요하다. 연료전지 자동차용 수소 인프라 조기 구축을 위하여 수소충전소 구축과 국산화 천연가스 수증기 개질기 개발을 병행하여 진행하였다. 수소 충전소 구축 부분은 충전소 부지 확보, 건물 건축, 각종 유틸리 티 설치의 토목 부분과 천연가스 개질형 수소 제조 유닛 설치, 수소 압축, 저장, 디스펜싱 시스템 설치를 포함하고 있으며 고압 설비에 대한 인허가 대응 및 안전대책 작업도 진행하였다. 구축된 수소충전소는 향후 연료전지 자동차 연계 실증 프로그램에 활용할 수 있다. 국산화 핵심 기술 개발을 위하여 열 및 시스템 통합 설계에 의 해 천연가스 수증기 개질기를 제작하고 내부 열교환 구조에 따른 개질기의 성능을 평가하였다. 개발된 개질기는 개질온도 $720^{\circ}C$, 수증기 대 카본 비 2.7의 운전조건에서 $23Nm^3/h$ 이상의 수소 생산이 가능하였으며 73% 이상의 개질 효율을 나타내었다. 개발된 천연가스 수증기 개질기는 향후 수소 정제용 PSA(Pressure Swing Adsorption) 시스템과 연계하여 수소충전소 국산화 엔지니어링 설계 패키지 개발의 핵심 기 술로 사용할 계획이다.시간 정도 운전한 후 시스템을 정지하였다 메탄 전환율과 일산화 탄소 농도, 열효율을 모니터링 하고 있으며, 현재까지 초기 성능을 그대로 유지하고 있다. 앞으로 일일시동-정지 운전 시험을 지속하면서 초기 시동 특성 및 부하 변동에 따른 응답 특성 개선, 그리고 연료전지와의 연계 운전을 실시할 예정이다 한다. 단위 전지 운전 온도 $130^{\circ}C$, 상대습도 37%의 운전 조건에서도 상당히 우수한 전지 성능을 보임에 따라 고온/저가습 조건에서 상용 Nafion 112 막보다 우수한 막 특성을 나타냄을 확인하였다.소/배후방사능비는 각각 $2.18{\pm}0.03,\;2.56{\pm}0.11,\;3.08{\pm}0.18,\;3.77{\pm}0.17,\;4.70{\pm}0.45$ 그리고 $5.59{\pm}0.40$이었고, $^{67}Ga$-citrate의 경우 2시간, 24시간, 48시간에 $3.06{\pm}0.84,\;4.12{\pm}0.54\;4.55{\pm}0.74 $이었다. 결론 : Transferrin에 $^{99m}Tc$을 이용한 방사성표지가 성공적으로 이루어졌고, $^{99m}Tc$-transferrin의 표지효율은 8시간까지 95% 이상의 안정된 방사성표지효율을 보였다. $^{99m}Tc$-transferrin을 이용한 감염영상을 성공적으로 얻을 수 있었으며, $^{67}Ga$-citrate 영상과 비교하여 더 빠른 시간 안에 우수한 영상을 얻을 수 있었다. 그러므로 $^{

  • PDF

Removal of Suspended Solids in Aquacultural Recirculating Water by Magnetic Fluid Separation (자성 유체분리에 의한 양어장 순환수내 부유 고형물의 제거)

  • KIM Yong-Ha;YEO Ryoung-Mo;SUH Kuen-Hack;KIM Hang-Goo;CHUNG Uoo-Chang;KIM Soon-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.5
    • /
    • pp.649-653
    • /
    • 1999
  • A magnetic fluid separation technology was confirmed to be very effective to remove the suspended solids (SS) from aquacultural recirculating water, In this study, the effects of operating variables on the characteristics of SS removal were investigated through the test runs using magnetite of 2 $\mu$m mean diameter as magnetic powder. Magnetic flocculation here formed by adsorbing fine magnetites on the surface of suspended solid was observed. The strength of magnet was of significance in determining the SS removal efficiency as well as the capacity of the equipment. In addition, the SS removal efficiency decreased with an increase in the superficial liquid velocity, but the effect became negligible when the mass ratio of magnetite to the suspended solids was higher than 1.0.

  • PDF

Flow Characteristics and Wind Loads on the Solar Panel and Floating System of Floating Solar Generato (부유식 태양광 발전기의 패널과 부유체에 작용하는 풍하중과 유동특성)

  • Ryu, Dae-Gyeom;Lee, Kye-Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.229-235
    • /
    • 2019
  • A floating photovoltaic generation system is a new concept that combines existing photovoltaic generation technology with floating technology. This is installed in the water not on conventional land and a building. The system is designed as a unit module type that can be connected to other modules according to the power generation capacity, thereby forming a large-scale power generation facility. As a renewable energy source, it is composed of a floating structure, mooring device, photovoltaic power generation facility, and underwater cable. Because this system is installed outdoors, the effect of the wind load on the structure is very large. In this study, the wind loads most affected on the floating photovoltaic generation structure were obtained by computational fluid dynamic analysis. The flow characteristics and wind loads were analyzed for a range of wind orientations and angles of inclination. The analysis showed the position and magnitude of the maximum wind load to the wind direction and the flow characteristics around the solar panel and floating system. The wind load increased with increasing angle of inclination of the panel to the ground.

Configuration of Fuel Cell Power Generation System through Power Conversion Device Design (전력변환장치 설계를 통한 연료전지 발전시스템 구성)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.129-134
    • /
    • 2021
  • Recently, the demand for electricity is gradually increasing due to the rapid industrial development and the improvement of living standards. In the case of Korea, which is highly dependent on fossil fuels due to such a surge in electricity demand, reduction and freezing of greenhouse gas emissions due to international environmental regulations will immediately lead to a contraction in industrial activities. Accordingly, there are many difficulties in competition with advanced countries that want to link the environment with the country's industrial production activities, and the development of alternative energy as a countermeasure is of great interest around the world. Among these new power generation methods, small-scale power generation facilities with relatively small capacity include photovoltaic generation, wind power generation, and fuel cell generation. Among them, the fuel cell attracts the most attention in consideration of continuous operation, high power generation efficiency, and long-term durability, which are important factors for practical use. Therefore, in this paper, the fuel cell power generation system was researched and constructed by designing the power conversion circuit necessary to finally obtain the AC power used in our daily life by using the DC power generated from the fuel cell as an input.

Numerical Modeling for Effect on Bund Overtopping Caused by a Catastrophic Failure of Chemical Storage Tanks (저장시설의 순간 전량 방출 시 방류벽의 월파 효과에 대한 수치모델링)

  • Min, Dong Seok;Phark, Chuntak;Jung, Seungho
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.42-50
    • /
    • 2019
  • As the industry develops in Korea, the use of hazardous chemicals is increasing rapidly and chemical accidents are increasing accordingly. Most of the chemical accidents are caused by leaks of hazardous chemicals, but there are also accidents in which all the substances are released instantaneously due to sudden high temperature/pressure or defection of the storage tanks. This is called catastrophic failure and its frequency is very low, but consequence is very huge when it occurs. In Korea, there were 15 casualties including three deaths due to catastrophic rupture of water tank in 2013, and 64 instances of failures from 1919 to 2004 worldwide. In case of catastrophic failure, it would be able to overflow outside the bund that reduces the evaporation rate and following consequence. This incident is called overtopping. Overseas, some researchers have been studying the amount of external overflow depending on bund conditions in the event of such an accident. Based on the previous research, this study identified overtopping fraction by condition of bund in accordance with Korea Chemicals Controls Act Using CFD simulation. As a result, as the height increases and the distance to the facility decreases while meeting the minimum standard of the bund capacity, the overtopping effect has decreased. In addition, by identifying the effects of overtopping according to atmospheric conditions, types of materials and shapes of bunds, this study proposes the design of the bund considering the effect of overtopping caused by catastrophic failure with different bund conditions.

Design of High Efficiency Permanent Magnet Synchronous Generator for Application of Waste Heat Generation ORC System (폐열발전 ORC 시스템 적용을 위한 고효율 영구자석형 동기발전기 설계)

  • Yeong-Jung Kim;Seung-Jin Yang;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2023
  • The power generation method using expensive diesel has operation problems such as high cost diesel generator and a lack of reserved power due to increase of power demand in some islands, requiring expansion of power generation facilities. To solve this problems, it is necessary to improve the efficiency of power generation facilities through an ORC(Organic Rankin Cycle) system application that uses waste heat as a heat source. Therefore, localized application technology of price competitive and highly reliable ORC power generation system is needed, and optimization technology of generators is having great effect, so this study performed two generator designs to get a high-efficiency generator with an optimized 30kW output. The comparison of simulation data for two designed models showed that a generator with SPM factor of 46.2% had an efficiency of 92.1% and a power ouput of about 23.2kW based on 12,000rpm, a generator with SPM factor of 44.46%, had a power output of 27.9kW and efficiency of 93.6% based on above rpm. For the verification of improved design model with SPM factor of 44.46%, the prototype test system with 110kW motor dynamometer was installed and got to the efficiency of 92.08% with conditions of the rated capacity 25kW at 12,000rpm, the test results of prototype generator showed the validity of generator design.

The Short-and Long-term Employment Effects of reduced Working Hours in a Putty-Clay-Model (법정근로시간 단축의 단기 및 중·장기적 고용효과 : Putty-Clay-Approach)

  • Lee, Sang-Mok
    • Journal of Labour Economics
    • /
    • v.24 no.3
    • /
    • pp.13-38
    • /
    • 2001
  • The question about whether a shorter workweek may increase employment has been a serious issue and been furiously debated among collective bargainers. The advocators recommend publicly that a reduction in standard working hours will provide benefits to the unemployed through the provision of new jobs, and also can improve the quality of life workers. The opponents argue that a shorter workweek will increase labor costs and induce firms to reduce their production levels, and consequently cut back their demand for labor. Although the debate is still continuing, considerable has been made toward achieving the goal workweek reduction. The analytical framework of this paper is a Putty-clay-model, in which the short-and long-term impacts of changes in working time on the employment associated with the interrelations of wages, prices, hourly labour productivity, the firm's labor demand, business cycle and economic growth etc. must be analyzed.

  • PDF

Actual State of Structures and Environmental Control Facilities for Tomato Greenhouses in Chungnam Region (충남지역 토마토 재배온실의 구조와 환경조절설비 실태분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.73-85
    • /
    • 2009
  • An investigation was conducted to get the basic data for establishing structural safety and environmental management of tomato greenhouses in Chungnam region. The contents of the investigation consisted of actual state of greenhouse structures and environmental control facilities. Most of greenhouses were arch type single-span plastic houses and they had too low height for growing tomatoes. Frameworks of multi-span greenhouses were suitable, but those of single-span were mostly insufficient. Every greenhouse had thermal curtain movable or covering fixed inside the greenhouse for energy saving, and heating facilities were mostly warm air heater. Irrigation facilities were mostly drip tube and controlled by manual operation or timer. Almost all of the greenhouses didn't install high level of environmental control facilities such as ventilator, air circulation fan, $CO_2$ fertilizer, insect screen, supplemental light, and cooling device.

  • PDF

Evaluation of Oven Utilization Effects at School Foodservice Facilities in Daegu and Gyeongbuk Province (대구·경북지역 학교급식소 오븐 사용 효과 평가)

  • Lee, Jung-A;Lee, Jin-Hyang;Bae, Hyun-Joo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.7
    • /
    • pp.1064-1072
    • /
    • 2010
  • The objectives of this study were to gain an overview of practices and effect evaluation of oven utilization at school foodservice facilities in Daegu and Gyeongbuk province. Out of 147 dieticians, who responded for questionnaires, 44 dieticians used the oven and 103 dieticians did not use the oven. All statistical analyses were conducted with the SPSS 14.0 statistical software program. With regard to the style of foodservice system, 74.4% were urban, 23.3% were rural, and 2.3% were remote country. Also, 23.3% of school foodservices produced meals by batch cooking. According to the results of the expected effect and using effect analysis for 27 items, the average of evaluation score about expected effect was 1.64 points and that of using effect was 1.61 points. Both expected effect and using effect had higher scores than average points in 13 items out of 27 items. Using effect had higher scores than expected effect in 4 items. In conclusion, using ovens could help to increase foodservice satisfaction of students at school foodservice, because it can improve the various cooking methods and the food safety management. Therefore, it is important to modernize and automate cooking equipment for quality improvement of school foodservice operations.