• Title/Summary/Keyword: 설비보강

Search Result 85, Processing Time 0.029 seconds

Research of Stresses Distribution and Loading Weight on Concrete Electric Pole Considering Field Condition (설치조건을 고려한 배전용 콘크리트전주의 응력분포 및 하중에 관한 연구)

  • Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.183-188
    • /
    • 2004
  • A method of double-pole construction is developing to strengthen the mechanical intensity of the electric poles. Therefore the mechanical properties of the double-pole were researched in this paper. First, considering field special quality electric poles were established. In the next tensile force was applied and stress distribution and fatigue load were examined. When a base of the pole is concrete, mechanical intensity of the double-pole increased about 1.7 times compared a single pole. In the case of general soil base, the concrete base should be needed to expect the reinforcement effect of the double-pole.

The examination of Soyosan substaion's Voltage-system change for improving worn-out facilites (노후설비 개선을 위한 미군전용 66kV 소요산변전소 전압체계 변경 검토)

  • Lee, Seockchang;Kim, Sangjun;Yun, Boohyun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.245-246
    • /
    • 2015
  • 주한미군 전력공급 변전소는 남북대치 상태라는 군사적 특수성 때문에 설비의 주기적 유지보수 및 관리가 무엇보다 중요하다. 동두천 주한미군 이전계획에 따라 소요산변전소 설비보강은 중단되었고 전력설비 노후화는 더욱 심화되었다. 이로 인해 변전소 전력설비 안정성이 저하되고, 설비고장 발생시 사회적으로 큰 파장이 예상된다. 본 논문에서는 소요변전소의 노후설비 개선 필요성과 이를 위한 여러 방안을 실제 사례를 들어 설명하고자 한다.

  • PDF

Experimental Consideration for Stability Improvement of Steel Pole (통신용 강관전주의 안정성 개선을 위한 실험적 고찰)

  • Han, Jin-Woo;Jeong, Seong-Taek
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.302-305
    • /
    • 2007
  • 현재 통신용 강관전주는 상, 하로 2 분할된 강관을 조립하여 대부분 사용하고 있다. 콘크리트전주에 비해 가볍고, 길이가 짧기 때문에 도심지 등 협소한 지역에서도 시공이 가능하며 특히 소규모 인력으로 시공이 가능하다. 하지만 전주의 단면이 작아 별도의 기초 보강을 하지 않고서는 지반의 지지력이 부족하여 전주가 기울어지거나 전도되는 현상이 빈번히 발생하고 있으며, 또한 운반을 용이하게 하기 위하여 2 분할한 강관의 조립 부분에서의 꺽임 현상이 발생하여 도시 미관을 해치고 있는 실정이다. 통신전주의 안정성을 확보하기 위해서는 전주 자체가 보유한 강도를 발휘할 수 있도록 충분한 지반지지력이 확보되어 있어야 한다. 강관전주의 휨강도 실험 및 현장 지반지지력 실험을 통해 충분한 지반지지력을 확보할 수 있는 공법을 도출해 내고, 현재 강관전주의 지반지지력 보강을 위해 사용하는 콘크리트블록 설치 방식이 아닌 시공 편리성 및 안정성을 개선한 기초콘크리트 방식을 제시하고자 한다.

  • PDF

Experimental Study on the Strength of Underground Conduit (통신용 지하매설관의 강도 특성에 관한 연구)

  • Baik Song-Hoon;fang Wang-Kyu;Chung Sung-Tak
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.230-233
    • /
    • 2004
  • 현재 KT의 관로포설 공법은 관 상부 토피 1m를 확보한 상태에서 차량하중이 작용한다는 가정하에서 제정된 것이며, 토피 1m를 확보하지 못하는 구간에는 별도의 보강공법을 적용하고 있다. 그러나 현재 관로공사의 대부분을 차지하는 도로유관공사는 도로 조성이 종료되는 시점에는 토피 1m를 확보하지만, 도로조성 공사기간 중에는 별도의 보강공사 없이 토피 60cm 내외에서 공사 차량의 하중이 관로에 그대로 전달되고 있어 관로의 찌그러짐 현상이 발생하고 있다. 본 논문은 이와 같은 조건에서도 고품질의 관로를 확보하기 위하여 현행 FC관로 뿐만 아니라 지하매설관으로 사용되는 각종 재질의 관에 대한 특성을 검토하였으며 매설관 변형실험을 통하여 도로유관공사에 적합한 관로재질을 제시하였다.

  • PDF

A Study on the Development of Software Supporting the Superstructural Design of Offshore Plant (해양플랜트 상부구조설계 지원 소프트웨어 개발에 대한 연구)

  • Kim, Hyun-Cheol;Kook, Sung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.19-27
    • /
    • 2020
  • On an offshore plant topside, various types of offshore facilities for processing energy resources, such as oil and gas, and equipment and outfitting for connecting these facilities are installed in a limited space. An offshore plant superstructure is composed of numerous supporting rack structures and reinforcements for securing and supporting offshore installations and the related equipment. This paper describes the development of design support software to support this superstructure design efficiently. The developed design support software, which was based on AVEVA Marine's PML(Programmable Macro Language), supports the parametric method for superstructure design. A method of batch 3D modeling from 2D drawings for supporting rack structure produced in the basic and detailed design was also developed using AutoLisp. In addition, through the application example of superstructure module design, the design support software introduced in this paper can be expected to reduce the design time by more than 90% compared to the use of only basic functions of AVEVA PDMS.

Experimental Study on the Flexural Performance of Steel Beams Reinforced by AFRP Sheets (아라미드 섬유 쉬트를 이용한 철골 보 부재의 휨 보강 성능에 관한 실험적 연구)

  • Kim, Kang Seok;Nah, Hwan Seon;Kim, Kang Sik;Lee, Hyeon Ju;Lee, Kang Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.61-69
    • /
    • 2011
  • Fiber Reinforced Plastic (FRP) sheets have been widely used to retrofit and rehabilitate RC structures, while in case of retrofitting steel structures, there are no codes and researches. It stems from configuration of member and characteristics of bonding behavior. This study focused on the static behavior of steel beams reinforcement by AFRP sheets. The main objective of the experimental programme was the evaluation of the force transfer mechanism, the increment of the beam load carrying capacity and the bending stiffness. A bending test was conducted on a H-shaped steel beam, with aramid FRP sheets bonded to its flanges. The mid-span deflection and the strain from three points along AFRP sheets were recorded Test results exhibit that the increment of the load-carrying capacity with reference to a mid-span deflection level of 15 mm(1/125mm of the clear span) was equal to 9.4% and for the two layers case, an elastic stiffness increment is slightly higher than one layer case.

Experimental Study of a Seismic Reinforcing System without Power Interruption and Movement for Electric Panel on the Access Floor (무정전-무이설 방식의 전기판넬 내진보강시스템 시험연구)

  • Jang, Jung-Bum;Lee, Jong-Rim;Hwang, Kyeong-Min;Ham, Kyung-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The seismic reinforcing system is developed to prevent damage to electric panels which are installed on the access floor and are essential to the operation of various basic facilities such as electric power and communication etc., from earthquakes. The seismic capacity of seismic reinforcing system is verified through the shaking table test. The seismic reinforcing system is intended for the electric panel on the access floor, and installation is possible without movement and power interruption of the electric panel. The enveloped response spectrum is adopted considering the location of the electric panel in the building as input motion for the shaking table test. The shaking table tests are carried out with two electric panels that can be considered representative of general electric panels, and two types of access floors such as wood panel and steel panel, which are commonly used in the industrial field. As a result of tests, it is confirmed that the seismic reinforcing system secures the seismic safety of electric panels by preventing the overturning of electric panels during and after the shaking table tests. In the event that the seismic reinforcing system is applied to the electric panel on the access floor, damage to the electric panel from an earthquake can be effectively prevented, which can greatly contribute to the stable operation of domestic basic facilities.

The Study on Optimizing 2011 Summer Peak Power System Operation (2011년 여름철 전력계통 최적운영에 관한 연구)

  • Lee, Sung-Moo;Kim, Jin-Yi;Choi, Hong-Seok;Cho, Jong-Man
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.160-161
    • /
    • 2011
  • 우리나라는 냉방부하로 인해 여름철에 연중 전력소모량이 크게 증가한다. 이로 인해 전력설비의 여유도가 낮아져 전력계통의 취약성이 높아진다. 전기사업자는 송 변전설비 신설 및 보강, 발전설비 조기 준공을 통해 최대전력 발생에 대비한 준비를 한다. 전력거래소는 여름철을 기준으로 신규로 운영되는 송 변전설비 및 발전설비를 고려하여 최적의 전력계통 운영방안을 수립한다. 이때 수립된 전력계통 구성은 겨울철 운영방안 수립 전까지 우리나라 전력계통의 기본 틀이 된다. 본 논문은 2011년도 여름철 최대전력 발생에 대비하여 수립한 전력계통의 최적 운영방안을 제시한다. 주로 전년도와 비교하여 올해의 계통변화 내용 및 상정고장 발생에 대비한 전압안정도 및 과부하 해소대책을 다루고 있다.

  • PDF

The Buckling Analysis of Stiffened Opening Plastes with Two Opposite Elastic Supports and Two Other Opposite Simply Supports Subjected to In-Plane Pure Bending (면내휨을 받는 2변단순지지 2변 탄성지지 유공 보강판의 좌굴해석)

  • 김일중;정동조;이용수
    • Computational Structural Engineering
    • /
    • v.8 no.4
    • /
    • pp.149-158
    • /
    • 1995
  • When hot-rolled wide flanges are used as vertical compressive or bending member, opening web are often to take a space for equipments of pipe or duct. The Web of hot-rolled wide flange steel with opening may be analyzed as a rectangular plate, subjected to in plane force, and the buckling load is governed by the ultimate force of web. The result of the theory showed close agreement with the result of the finite element analysis. It was also shown that the buckling loads of stiffened opening plates could be larger than those of the plate. The stiffened opening plates for the 4-side simply supported case showed more stiffening effect than the Two Opposite Elastic Supports and Two Other Opposite Simply Supports case. In this study, we proposed the effective opening sizes that buckling loads of stiffened opening plate could be greater than those of the plates.

  • PDF

A Study on the Cause of the Fault on Underground Distribution Line (지중배전선로 고장요인에 관한 연구)

  • Jung, Jong-Yon;Seon, Sang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.302_303
    • /
    • 2009
  • 지중배전선로 고장발생현황을 분석한 결과 설비별로는 케이블 고장이 가장 많았고, 그 다음으로 개폐기, 접속재, 변압기 순으로 고장이 많이 발생하였다. 원인별로 보면 일반인 과실과 자연열화에 의한 고장이 대부분을 차지하였다. 지중고장 유형 중 가장 많은 케이블 외상 고장은 인적 과실에 의한 고장으로 이와 같은 인적 과실에 의한 고장이 전체 지중고장의 50% 이상을 차지하며 케이블 및 접속재 열화고장 등 관리소홀에 의한 고장은 전체 지중고장의 20% 이상을 차지하였다. 인적 과실 및 관리소홀에 의한 고장은 천재지변과는 달리 설비관리 노력으로 충분히 감소시킬 수 있다. 지중고장을 감소시키기 위한 구체적인 방안으로는 선로굴착개소 순시 및 입회 철저, 굴착개소 관련 DB의 정확도 유지, 설비열화 진단 및 보강, 설비진단 신기술 개발 및 도입, 접속개소 시공품질 향상 등이 필요할 것으로 판단된다.

  • PDF