• Title/Summary/Keyword: 설계인장강도

Search Result 493, Processing Time 0.027 seconds

Experimental Investigations of Combination Effects of Installation Damage and Creep Deformation on Long-Term Design Strength of Geogrids (지오그리드의 장기설계인장강도에 미치는 시공시 손상 및 크리프 변형 복합효과에 대한 실험적 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Oh, Se-Yong;Lee, Do-Hee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.4
    • /
    • pp.23-37
    • /
    • 2005
  • The factors affecting the long-term design strength of geogrid can be classified into factors on creep deformation, installation damage, temperature, chemical degradation and biological degradation. Especially, creep deformation and installation damage are considered as main factors to determine the long-term design strength of geogrid. Current practice in the design of a reinforced soil structures is to calculate the long-term design strength of a geosynthetic reinforcement damaged during installation by multiplying the two partial safety factors, $RF_{ID}$ and $RF_{CR}$. This method assumes that there is no evaluation of synergy effect between installation damage and creep deformation of geogrids. This paper describes the results of a series of experimental study, which are carried out to assess the combined effect of the installation damage and the creep deformation for the long-term design strength of geogrid reinforcements. A series of field tests was carried out to assess installation damage of various geogrids with respect to different fill materials, and then creep tests are conducted to evaluate the creep deformation of both undamaged and damaged geogrids. The results indicated that the tensile strength reduction factors, RF, considering the combined effect between the installation damage and the creep deformation is less than that calculated by the current design method.

  • PDF

The Effect of Variation of Design Parameters on the Flexural Behavior of UHPFRC Beams (UHPFRC 보 휨 거동에 대한 설계변수 변동의 영향)

  • Yang, In-Hwan;Kim, Kyung-Chul;Park, Ji-Hun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.2
    • /
    • pp.138-145
    • /
    • 2018
  • This paper studies the bending behavior of ultra-high-performance fiber-reinforced concrete (UHPFRC) beams focused on the effect of variation in major material design parameters such as tensile strength, elastic modulus of UHPFRC, and rebar ratio. Analytical results show that the variation in the range of ${\pm}20%$ in the tensile strength of UHPFRC causes the significant difference in ${\pm}8{\sim}9%$ of bending strength compared to the reference condition. The variation of elastic modulus in UHPFRC rarely causes the effect on the bending strength of the UHPFRC section, whereas causes the difference in the slopes of moment-curvature curves, indicating different bending stiffness of UHPFRC sections. For the rebar with yield strength of 400MPa, the bending strength of SC120f is increased by 30, 67, and 99% when the rebar ratio is 1.0, 1.5, and 20%, respectively, compared to the rebar ratio of 0.5%. Therefore, it is observed that the variation of rebar ratio significantly affects the difference in bending strength of UHPFRC beams. However, as the compressive strength of UHPFRC becomes greater, the effect of rebar ratio on the increase of bending strength is decreased.

Bond Characteristics of High-Strength Concrete (고장도 콘크리트의 부착특성에 관한 연구)

  • Lee, Joon-Gu;Mun, In;Yum, Hwan-Seok;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.5
    • /
    • pp.499-506
    • /
    • 2001
  • Eight direct tension tests were conducted to study the bond characteristics and crack behavior in high-strength concrete axial members. The main variable was the concrete strength up to 61-63 MPa. The specimens consisted of two different types of the short specimens modeled the part between transverse cracks and the long specimens having numerous transverse cracks. The results obtained show that the bond strength increases in proportion to compressive strength. Thereby, in high-strength concrete the length of stress-disturbed region is shortened and the space of adjacent transverse cracks become smaller. Although the concrete strength varies from 25 MPa to 61 MPa, the split cracking loads remain constant, while transverse cracking loads vary as variation of concrete tensile strength. Accordingly, the current code provisions for development length may need reconsideration in high-strength concrete members, and it is recommended that either thicker cover or transverse reinforcement should be additionally provided for high-strength concrete members.

Geosynthetic Embankment Stability on Soft Ground Considering Reinforcement Strain (보강재의 변형을 고려한 연약지반위 섬유보강성토제체의 안정해석)

  • 이광열;정진교;황재홍;홍진원;안용수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.867-874
    • /
    • 2003
  • 섬유보강재를 이용한 성토제체의 설계에서 기존의 방법은 보강재의 변형을 무시하고 흙의 변형만을 중요시하고 있다. 보강재에 의해 보강된 성토제체의 파괴면에서 보강재와 흙의 거동은 초기응력단계에서는 일체거동현상을 나타내지만 응력의 증가에 따라 변형량에서 차이를 보인다. 이러한 문제는 토공구조물의 보강재를 설계하는데 있어서 중요한 요소로서 보강효과에 큰 영향을 미칠 수 있다. 본 연구에서는 연약지반 위에 PET Mat로 보강하여 축조한 성토제체에서 보강재와 흙의 응력 - 변형거동을 수치해석을 통하여 분석하였다. 연구결과, 파괴면에서 보강재의 변형은 보강재의 인장강도 크기에 따라 큰 차이를 보이고 있다. 외부하중에 의해 보강재에 발생하는 최대응력은 보강재의 항복인장강도를 초과하지 않으며, 보강재에 발생하는 응력이 성토체에서 발생하는 응력이상일 때 이상적인 것으로 나타났다. 또한 제체의 전단파괴에 대한 안전율은 보강재의 항복인장강도가 증가할수록 증가하는데 보강재와 흙의 변형이 일치되는 이후부터는 안전율의 증가율은 거의 미미한 것으로 나타났다.

  • PDF

Assessment of Combined Effect of Installation Damage and Creep Deformation of Geogrids (지오그리드의 시공 시 손상 및 크리프 변형의 복합효과 평가)

  • Cho Sam-Deok;Lee Kwng-Wu;Oh Se-Yong;Lee Do-Hee
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.153-161
    • /
    • 2005
  • A series of installation damage tests and creep tests are performed to assess the combined effect of installation damage and creep deformation far the long-term design strength of geogrid reinforcement. Three types of geogrids are used to investigate the influence of the geogrid types. From the experimental results, it is shown that installation damage and creep deformation of geogrids significantly depends on the polymer types of the geogrids and the larger the installation damage, the more the combined effect of installation damage and creep deformation. In addition, The results of this study show that the tensile strength reduction factor, RF, considering the combined effect between installation damage and creep deformation is less than that calculated by the current design practice which calculates the long-term design strength of geogrids damaged during installation by multiplying two partial safety factors, $RF_{ID}$ and $RF_{CR}$.

Assessments of Installation Damage and Creep Deformation of Geogrids (지오그리드의 시공시 손상 및 크리프 변형 특성 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Oh, Se-Yong;Lee, Do-Hee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.4
    • /
    • pp.29-40
    • /
    • 2004
  • The factors affecting the long-term design strength of geogrids can be classified into factors on creep deformation, installation damage, temperature, chemical degradation, biological degradation. Especially, creep deformation and installation damage are considered as main factors to determine the long-term design strength of geogrids. This paper describes the results of a series of experimental investigation, which were conducted to assess the installation damage according to different fill materials and creep characteristic of various geogrids. The results of this study show that the installation damage and creep deformation of geogrids significantly depends on a row material and a manufacturing process of geogrids.

  • PDF

Development of Mechanical Test Techniques for Irradiated Zircaloy Cladding in Hot Cell (조사 지르칼로이 피복관의 기계적 특성시험 기술 개발)

  • 김도식;홍권표;주용선;안상복;송웅섭;유병옥;김기하
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.213-213
    • /
    • 2003
  • 고온 및 고압의 가혹한 방사선 분위기에서 사용되는 핵연료 피복관은 중성자 조사 및 수소화합물의 생성 등으로 인하여 기계적 성질이 저하된다. 따라서 조사된 핵연료 피복관의 손상기준 확립과 안전성 해석을 위해서는 연성 및 강도 등 기계적 특성을 정확히 이해하여야 할 필요가 있다. 핵연료 피복관의 종 및 횡 방향 인장특성 평가를 위하여 개발된 기존의 다양한 시험법들을 비교하고, 핫셀시험에 적합한 인장시험법을 개발하였다. 피복관의 종방향 인장시편은 튜브시편 또는 게이지부 내에서 균일한 변형률 분포를 얻도록 설계된 도그본 튜브시편(그림 1)을 사용한다. 피복관의 횡방향 인장시험에 사용되는 링시편(그림 2)은 게이지부 내에서 균일한 단축 원환변형율 분포 또는 평면변형율 조건을 나타내도록 설계한다. 연소 또는 조사된 피복관으로부터 시편을 제작하기 위해서는 핫셀 내에서 작업 이 가능한 방전가공기(그림 3)를 사용한다. 피복관의 종방향 인장시험용그립(grip)은 핀-부하형이며, 횡방향 인장시험의 경우는 시험 동안 시편의 곡률이 일정하게 유지 되도록 그립의 형상 및 치수를 결정한다(그림 4). 피복관의 종 및 횡방향 강도와 변형 등 기계적 특성을 평가하기 위한 응력-변형율 곡선은 시험기의 복합 강성(K)을 고려하여 결정한다. 이상과 같이 검토된 인장시험법은 피복관의 안전성 해석(safety analysis)과 관련 규정(regulatory)에서 사용되는 피복관 손상기준(fuel damage criteria)의 개선에 필수적인 자료를 제공한다.

  • PDF

Tensile Strength Characteristics of ETFE Roof Material in Large Membrane Structuresb (초대형 막구조물 지붕용 ETFE 필름 막재의 인장특성)

  • Lee, Seung-Jae;Lee, So-Ra
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.1
    • /
    • pp.51-58
    • /
    • 2010
  • ETFE is the abbreviation of Ethylen Tetra Fluoro Etylene, a sort of colorless and transparent granules. The advantage ETFE film has daylight transmission and chemical the resistance and The thickness of ETFE film is used to from $50{\mu}m$ to $300{\mu}m$ and tensile strength of ETFE film changes from 40MPa to 60MPa and the tensile strain at break can get to about 300-400%. In this paper, ETFE film carried out the tensile proprieties, such as the tensile strain at break, the tensile strength are examined.

  • PDF

Prediction of Flexural Capacity of Steel Fiber-Reinforced Ultra High Strength Concrete Beams (강섬유 보강 초고강도 콘크리트 보의 휨강도 예측기법의 제안)

  • Yang, In Hwan;Joh, Changbin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.317-328
    • /
    • 2010
  • The method to evaluate the flexural capacity of steel fiber-reinforced ultra high strength concrete beams was proposed in this study. An experimental program was set up and fourteen beams have been tested. Test results were compared with predictions by design code and by the proposed method, respectively. It was found that predictions by using ACI 544 Committee recommendations considerably underestimate the flexural capacity. Underestimation of flexural capacity resulted from that of tensile stress block. Three-point bending test data of notched prism specimens and their inverse analysis results were incorporated into modeling of tension stress block. The ratio of the predicted to the experimental flexural capacity was in the range of 0.98 to 1.14. The present study represents that the proposed method allows more realistic prediction of flexural capacity of steel fiber-reinforced ultra high strength concrete beams.

An Experimental Study on Tensile Properties of Steel Fiber-Reinforced Ultra High Strength Concrete (강섬유 보강 초고강도 콘크리트의 인장 특성 실험 연구)

  • Yang, In-Hwan;Park, Ji-Hun;Lee, Jae-Ho
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.3
    • /
    • pp.279-286
    • /
    • 2019
  • In this study, an experimental study on the tensile properties of steel fiber-reinforced ultra high strength concrete(UHSC) with a standard compressive strength of 180MPa was performed. Steel fibers with a volume ratio of 1% were mixed to prepare direct tensile strength specimens and prism specimens for the three-point bending test. The fabricated specimens were set up in the middle section of the specimen to induce cracks, and the test was carried out according to each evaluation method. First, the stress-strain curves were analyzed by performing direct tensile strength tests to investigate the behavior characteristics of concrete after cracking. In addition, the load-CMOD curve was obtained through the three-point bending test, and the inverse analysis was performed to evaluate the stress-strain curve. Tensile behavior characteristics of the direct tensile test and the three-point bending test of the indirect test were similar. In addition, the tensile stress-strain curve modeling presented in the SC structural design guidelines was performed, and the comparative analysis of the measured and predicted values was performed. When the material reduction factor of 1.0 was applied, the predicted value was similar to the measured value up to the strain of 0.02, but when the material reduction factor of 0.8 was applied, the predicted value was close to the lower limit of the measured value. In addition, when the strain was greater than 0.02, the predicted value by SC structural design guideline to underestimated the measured value.