• Title/Summary/Keyword: 설계시험평가

Search Result 1,945, Processing Time 0.03 seconds

Improvement of Field Installation Method for Asphalt Concrete Pavement Strain Gauge (아스팔트 콘크리트 포장 변형률계 매설 방법 개선에 관한 연구)

  • Lee, Jae-Hoon;Kim, Ji-Won;Kim, Do-Hyung;Lee, Kwang-Ho
    • International Journal of Highway Engineering
    • /
    • v.5 no.3 s.17
    • /
    • pp.31-42
    • /
    • 2003
  • The KHC Test Road project was initiated on 1991 to develop Korean Pavement Design Guide. It was constructed along the Joongbu Inland Expressway line between Yeoju and Gamgok. It is two-lane wide expressway containing fifteen asphalt and twenty-five Portland cement concrete test pavement sections. Various sensors were installed in the Test Road to evaluate the behavior of test pavement sections under the influence of traffic load and environmental change. The most important issues in the sensor installation are the accurate location and long-term survivability. They are directly influenced by the sensor installation methodology. The methodology for asphalt strain gages is mainly discussed in this paper because it is the second important sensors in the KHC Test Road project. In order to find the best methodology, we evaluated existing methodology from prior experience and several conducted test installations. We have tried mound, block out, and trench cuts since 2000. Among three methods, block out was the most effective one in terms of accurate location, long-term survivability, and material homogeneity. However, this method cannot be applied to the wearing coarse so that the mound method was used as an alternative. The block out method was applied to base and intermediate layers while the mound method was used to the wearing coarse. Three hundred seventy-four asphalt strain gauges were installed on asphalt pavement sections from September 3rd to November 18th in 2002. According to the sensor measurement evaluation, 6.3% of sensor demonstrated over ranged readings for mound method installation and 2.5% did for block out method installation. We lost only two sensors during the installation. It is 99.5% survival and it is excellent survival rate according to other experience.

  • PDF

Evaluation of Correlation between Subgrade Reaction Modulus and Strain Modulus Using Plate Loading Test (평판재하시험을 이용한 지반반력계수와 변형률계수의 상관관계 평가)

  • Kim, Dae-Sang;Park, Seong-Yong;Kim, Soo-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.6
    • /
    • pp.57-67
    • /
    • 2008
  • Two test methods, nonrepetitive plate loading test (NPLT) and repetitive plate loading test (RPLT) are being used to control the quality of compaction through the evaluation of the stiffness of subgrade soils in the Korea railway industry. Subgrade reaction modulus ($k_{30}$) from the NPLT and strain modulus ($E_v$) from the RPLT are the index values to check them. The methods have similar aspects, but they differ in the modulus evaluation method, the numbers of loading stage, termination procedures, etc. This paper analyses the differences of the two test methods and evaluates the relationship between subgrade reaction modulus and strain modulus. In order to develop the relationship, total 22 tests were performed including the NPLT and the RPLT at the 6 original grounds, and 5 upper or lower subgrades in Kyungbu High Speed Railway II stage construction sites. According to the soil conditions, the relationship between subgrade reaction modulus and strain modulus was proposed with corrections by considering strain states, mean confining pressures, and Poisson's ratio.

크라이오 펌프 종합특성평가 시스템 기술개발

  • In, Sang-Ryeol;Jeong, Seung-Ho;Hwang, Pil-Seo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.93-93
    • /
    • 2011
  • 고진공 펌프 국산화의 일환으로 터보분자 펌프와 크라이오 펌프 개발이 진행 중이다. 크라이오 펌프 개발은 기계연구원, 우성진공(주), 국민대학교가 연합해서 수행하고 있다. 올해 9월말에 끝나는 1단계 마지막 3차 년도에는 두 고진공 펌프 모두 시제품을 완성하고 성능을 입증해야 한다. 이를 위해 고진공 펌프 개발과 별도로 진공 펌프 종합특성평가 시스템 개발도 표준과학연구원 주도로 진행되고 있는데 크라이오 펌프 평가 시스템은 원자력연구원이 담당하고 있다. 완성된 크라이오 펌프 성능평가 장치는 상온 기준 5${\times}$10-11 mbar의 기저압력을 보이고 있어서 초고진공 영역에서 크라이오 펌프 운전성능을 평가할 수 있는 준비를 마쳤다. 현재 크라이오 펌프 냉동기는 전반적으로 목표 설계치에 근접한 냉각성능을 나타내고 있는데 예를 들면 2차 냉각단 냉각능력이 10 K, 10 W로 대형 크라이오 펌프를 제작하기에도 충분하다. 활성탄 어레이도 여러 모델들을 자작하여 배기성능을 시험해 보았으므로, 최종적으로 3,600 L/s 급에 적합한 어레이를 만들고 이를 개발된 냉동기에 얹고 열차폐와 몸통을 씌워 펌프로서의 운전성능을 평가하는 일이 남아있다. 시제품은 상용품과 달리 기기가 차지하는 공간이 크고 부대설비가 복잡해서 운전성능 평가 장치에 부착해서 실험하기 어려울 수도 있으므로 기계연구원 현장에서 진공 게이지와 기체도입구만 부착한 마구리 플랜지를 펌프 흡기구 위에 달고 간이로 배기속도를 측정하는 것도 고려하고 있다. 이 경우는 표준용기를 사용할 때보다 배기속도가 과대평가되므로 이를 보정해 주는 방안을 마련해 놓아야 한다.

  • PDF

Pilot Application of Fire Barrier Penetration Seal Evaluation in Nuclear Power Plant (원자력발전소 방화벽 관통부 성능평가 시범 적용)

  • Park, Jun-Hyun
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.98-104
    • /
    • 2006
  • The Fire Protection Regulatory documents require the fire-resistive rating of fire barrier penetration seals be same as that of fire barriers. Pilot application of penetration seal evaluation for K nuclear plant, built before penetration seal requirements were made, was done. In this evaluation, visual inspection and estimating fire rating by comparing installed configuration with tested configuration of penetration seals, called bounding approach method, were applied. Further improvements for retrofit and maintenance are recommended with penetration seal evaluation results also. The practical use of the methodology adopted in this study and the evaluation result of K nuclear plant will be anticipated for other plant's penetration seal evaluation.

Evaluation of Dynamic Soil Properties Using Dynamic Tests (동적시험에 의한 동적지반특성 평가)

  • Lee, Myung Jae;Shin, Jong Ho;Kang, Ki Young;Chon, Chun Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.91-102
    • /
    • 1990
  • The representative tests in this study are performed at a selected site which has the soil layers to analyze the safety and economy of the dynamic analysis for the variable soil conditions. Crosshole test and downhole test of small strain level tests and triaxial test of large strain level test are performed in the soil layers, and in the rock layers, crosshole test and downhole in-situ tests and laboratory sonic test are performed to measure the dynamic shear modulus, damping ratio, and Poisson$\acute{s}$ ratio of the soil and the rock. The correlations between the dynamic soil properties from the tests and the basic soil properties are determined through the regression analysis. The representative design value of the soil is determined by probability analysis of the test results. It is determined from the nonlinear stress-strain model in soils, and the value at small strain level is computed in rocks according to the distribution of the type of soils and the affecting variables. The constitutive value is systematized to be utilized in the analysis of the test results, and computation of the input soil data.

  • PDF

Study on the Impact Analysis of Front Loader for Tractor (트랙터용 프론트 로더의 충격해석에 관한 연구)

  • Lim, Gi-Soo;Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5051-5059
    • /
    • 2015
  • Structural behaviour of the front loader for an agricultural tractor was analyzed for three impact test conditions: drop and catch, corner pull, and corner push. Rigid-body dynamic, transient structural, and static structural analyses were conducted using a commercial finite element software. Analysis of the drop and catch test dealt with the case that the bucket located at the maximum elevation was dropped and catched through three steps. Analysis of the corner pull test dealt with the case that the bucket constrained to the ground by a chain at its corner was raised suddenly. Analysis of the corner push test dealt with the case that the corner of the bucket collided with an obstacle. Results of analyses of the three test conditions showed that maximum stress occurs at the geometrically discontinuous location in the mount and is caused from local stress concentration. Results of the present research can be utilized as a guideline to achieve more reliable and safe structural design of the front loaders.

Liquid Oxygen Supercooling System in the 75 tonf-class Liquid Engine Combustion Test Facility (75톤급 액체엔진 연소시험설비의 액체산소 과냉각 시스템)

  • Seo, Daeban;Yoo, Byoungil;Lee, Jungho;Cho, Namkyung;Kim, Seunghan;Han, Yeoungmin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1080-1083
    • /
    • 2017
  • In the design of KSLV-II, there is a scenario in which supercooled liquid oxygen is supplied to prevent a geysering phenomenon in the oxidizer pipe and a cavitation phenomenon at the pump inlet. To verify this condition in the engine development test phase, a system that supplies supercooled liquid oxygen to the engine was applied in the engine combustion test facility. In this system, supercooling methods using a vacuum ejector and using helium injection to the tank were appied. Both tests were carried out for about 17 minutes. Supercooling results of about 3.3K for the ejector test and about 2.2K for the helium injection test were obtained at the 50% level of the tank.

  • PDF

An Experimental Study of Fatigue and Static Behavior for Composite Deck Member (복합재료 바닥판 부재의 정적 및 피로거동에 관한 시험적 연구)

  • Kim, Doo-Hwan;Kim, Young-Chan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.15-21
    • /
    • 2011
  • It is required to accumulate experimental datum that make the theories easy to general technicians in order to use composite material widely on construction field. Therefore, we intend to present base technologies that evaluate static and fatigue performance according to the FRP deck section and offer the basis datum for FRP deck analyses and the design standards. As results of static tests, it can be shown that specimen with fabric direction has higher rigidity than that with normal to fabric direction and convergence for the datum. Due to this reason, it has more stable behavior by structural characteristics of matrix arrangement during destruction. For the fatigue tests, we found that by increasing the number of test repetition, test specimen with fabric direction had an crack just before the destruction, and the contact surface was detached.

Experimental Study on the Infilling Characteristics of CFT Column Infilled by Pumping-Up Below (하부압입공법에 의한 콘크리트 충전강관(CFT)기둥의 충전특성에 관한 실험적 연구)

  • Kim, Myoung Mo;Jeon, Sang Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.2
    • /
    • pp.375-383
    • /
    • 2002
  • To evaluate the applicability of the construction method involving infilling CFT columns by pumping-up, a trial construction was done using 6 actual size test samples. The 12.8m-high test samples were similar to a four-story building scale. The pumping-up level was controlled at 12m. The test used two types of high performance concrete with $450kgf/cm^2$ standard design strength, and a concrete pump which is used domestically. The pressure changes in pipes or pump as well as the changes in concrete characteristics were measured during construction. in order to evaluate applicability. After the concrete hardened, the column was dismantled. The filled state of the concrete, concrete strength distribution according to column height, etc., were checked to evaluate the quality of the concrete, From the results, some basic data which characterize the pumping-up pressure were suggested. Also, the strength of hardened concrete as well as the filled state were proven to be acceptable ranges.

Statistical Analysis for Fatigue Life Evaluation of Vehicle Muffler (자동차용 머플러의 피로수명평가를 위한 통계적 분석)

  • Choi, Ji-Hun;Lee, Yong-Jun;Yoon, Jin-Ho;Kang, Sung-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.365-372
    • /
    • 2013
  • In this study, a statistical method for evaluating the fatigue life of a vehicle muffler was used to obtain reliable fatigue data using a limited number of specimens. Cyclic bending tests were conducted using specimens manufactured to be exactly the same as the mufflers installed in cars that are currently in use. To estimate the fatigue life by comparing the data obtained during the fatigue tests, the most suitable probability density function for the normal, lognormal, and Weibull distributions was selected. A goodness-of-fit test was performed on the probability distributions, and then a Weibull distribution using the least square method was selected. By using the selected Weibull distribution, the probability-moment-life curves (P-M-N curve) reflecting the fatigue characteristics were suggested as the data for the reliable design of a muffler.