• Title/Summary/Keyword: 설계시험평가

Search Result 1,945, Processing Time 0.028 seconds

Effects of Dietary Nutrient Levels on Growth Performance, Blood Urea Nitrogen, and Meat Quality in Finishing Pigs (비육돈에 있어서 영양소 및 원료 첨가수준이 다른 사료의 급여가 생산성, 혈중 요소태질소 및 육질특성에 미치는 영향)

  • Shin, Seung-Oh;Cho, Jin-Ho;Kim, Hae-Jin;Chen, Ying-Jie;Yoo, Jong-Sang;Wang, Yuan;Huang, Yan;Kim, In-Ho
    • Food Science of Animal Resources
    • /
    • v.27 no.4
    • /
    • pp.387-391
    • /
    • 2007
  • This study was conducted to evaluate effects of dietary nutrient levels on growth performance, blood urea nitrogen, and meat quality in finishing pigs. A total of ninety six pigs ($Landrace{\times}Yorkshire{\times}Duroc$) were used in this 66 day study. Dietary treatments included 1) T1 (ME 3,441 kcal/kg, CP 16.30%, Lysine 0.93%), 2) T2 (ME 3,433 kcal/kg, CP 17.00%, Lysine 1.00% and 3) T3 (ME 3,449 kcal/kg, CP 17.00%, Lysine 1.00%). During the overall period, there were no significant differences in ADG (average daily gain), ADFI (average daily feed intake), gain/feed ratio or BUN (blood urea nitrogen) among the treatments (p>0.05). The $b^*$ value of M. longissimus dorsi muscle color significantly increased (p<0.05) with T3 treatment compared to T2 treatment. However, there were no differences in the $L^*\;and\;a^*$ values, pH, M. logissimus dorsi area, drip loss, cooking loss, TBARS and WHC (water holding capacity) for pigs fed the various treatments (p>0.05). The total feed cost per kg of weight gain was not significantly different among the various dietary treatments (p>0.05). In conclusion, these results show no effects of dietary nutrient levels on growth performance and meat quality in finishing pigs, and also suggest that a high nutrient density diet may not be a beneficial feeding strategy for finishing pigs in terms of cost.

Evaluation of Odors and Odorous Compounds from Liquid Animal Manure Treated with Different Methods and Their Application to Soils (액상 가축분뇨의 처리 및 토양환원에 따른 악취 및 악취물질의 평가)

  • 고한종;최홍림;김기연;이용기;김치년
    • Journal of Animal Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.453-466
    • /
    • 2006
  • To comply with stricter regulations provoked by increasing odor nuisance, it is imperative to practice effective odor control for sustainable livestock production. This study was conducted to assess odor and odorous compounds emitted from liquid animal manure with different treatment methods such as Fresh Manure(without treatment, FM), Anaerobic Digestion(AD) and Thermophilic Aerobic Digestion(TAD) and their application to soil. Air samples were collected at the headspace of liquid manure, upland and paddy soil, and analyzed for odor intensity and offensiveness using an olfactometry; odor concentration index using odor analyser; nitrogen-containing compound such as ammonia(NH3) using fluorescence method; and sulfur containing compounds such as hydrogen sulfide(H2S), methyl mercaptan(MeSH), dimethyl sulfide(DMS) and dimethyl disulfide(DMDS) using gas chromatography-pulsed flame photometric detector, respectively. Odor intensity, offensiveness and concentration index from TAD liquid manure was statistically lower than those from FM and AD(p<0.01). Mean concentrations of H2S, MeSH, DMS, DMDS and NH3 were 65.93ppb, 18.55ppb, 5.26ppb, 0.33ppb and 10.57ppm for liquid manure with AD; and 5.15ppb, 0.97ppb, 0.80ppb, 0.56ppb and 1.34ppm for liquid manure with TAD, respectively. More than 60% of malodorous compounds related to nitrogen and sulfur were removed by heterotrophic microorganisms during TAD treatment. When liquid manure was applied onto upland and paddy soil, NH3 removal efficiencies ranged from 51 to 94% and 22 to 91% for AD and TAD liquid manure, respectively. The above results show that liquid manure with TAD is superior to AD and FM with respect to the odor reduction and odor problem caused by land applied liquid manure is directly related to the degree of odor generated by the manure treatment method.

Thickness Effects on the Fatigue Strength of Butt Welded Specimens using SM520C-TMC Steel (SM520C-TMC 강재의 피로강도에 대한 두께효과)

  • Kim, Kyoung Nam;Jung, In Su;Hwang, Nak Yeon;Jung, Kyoung Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.6 s.73
    • /
    • pp.847-855
    • /
    • 2004
  • The criterion or specification on fatigue design has been generally based on fatigue strength curve derived by tests on specimens with varying thickness (10-30mm). Making the plate thicker, however, also decreases fatigue strength. It has been noted from the test results and the results of the analysis by fracture mechanics that the effect of thickness cannot be bypassed. From the several fatigue strength curves of specimen tests, modification of fatigue strength on plate thickness has been proposed. In this study, fatigue tests on SM520C-TMC were carried out, and the effects of thickness were evaluated. Finally, in consideration of the thickness, the modification of fatigue strength was derived. Comparing the results of this paper with those of previous studies, an outline of the behavior obtained is similar to previous ones, but the rate of decrease is smaller.

Combustion and Emission Characteristics of Utility Boiler burning Anthracite-Bituminous Coal Blends (발전용 보일러에서의 유, 무연탄 혼소시 연소 및 환경특성)

  • Park, Ho-Young;Kim, Young-Joo;Park, Hyun-Joo;Kim, Sung-Chul
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.153-160
    • /
    • 2008
  • The combustion behaviors of the blends of Korean anthracite, bituminous coal and their blends were studied with a thermogravimetric analyzer. Concerning the burning profiles of the anthracite-bituminous coal blends in TGA, it has been observed the independent burning of two coals without any interaction between two coals. With the blends of 50% anthracite with 50% bituminous coal in weight basis, the combustion tests in a utility boiler have been carried out for the analysis of the combustion and operational characteristics by increasing the power output from 134 MW to 197 MW. The stable combustion has been observed in a boiler. With the increase of power output, the exhaust gas temperature was exceeded the design value of $430^{\circ}C$, so the combustion air was taken from atmosphere instead of the boiler penthouse.

Evaluation of impact resistance of high performance fiber reinforced cementitious composites under high-speed projectile crash (고속 비상체 충돌에 대한 고성능 섬유보강 시멘트 복합체의 방호성능 평가)

  • Moon, Jae-Heum;Park, Jung-Jun;Park, Gi-Joon;Cho, Hyun-Woo;Kim, Sung-Wook;Lee, Jang-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4950-4959
    • /
    • 2015
  • The importance of public infrastructures' protection against crash or blast loads has been emerging issue as structures are becoming bigger and population densities in downtown cities are growing up. However, there exists no sufficient study which considers the developments of protective building materials, that are essential for protective design and construction. To assess the protection performance and the applicability as protective materials of high performance fiber reinforced cementitious composites(HPFRCC), this study performed the impact tests with 40 mm gas-gun propelled projectile crash machine. From this study, it has observed that both high compressive strength of cement matrix and fiber reinforcement are beneficial for the improvement of impact resistance.

Experimental Study on Hydrogen Direct Reduction of Hematite in a Lab Scale Fluidized Bed Reactor by Estimating the Gas Consumption Rate

  • Hasolli, Naim;Jeon, Seong Min;Park, Young Ok;Kim, Yong Ha
    • Clean Technology
    • /
    • v.21 no.2
    • /
    • pp.96-101
    • /
    • 2015
  • Hematite reduction using hydrogen was conducted and the various process parameters were closely observed. A lab scale fluidized bed unit was designed especially for this study. The optimal values of the gas velocity, reduction time and temperature were evaluated. The values which indicated the highest reduction rate were set as fixed parameters for the following tests starting with the reduction time of 30 minutes and 750 ℃ of temperature. Among these variables the one with the highest interest was the gas specific consumption. It will tell the amount of the gas which is required to achieve a reduction rate of over 90% at the optimal conditions. This parameter is important for the scale up of the lab scale unit. 1,500 Nm3/ton-ore was found to be the optimal specific gas consumption rate at which the reduction rates exhibit the highest values for hematite.

Effect of the Size and Location of a Web Opening on the Shear Behavior of High-Strength Reinforced Concrete Deep Beams (고강도 철근콘크리트 깊은 보의 전단거동에 대한 개구부 크기 및 위치의 영향)

  • Yang, Keun-Hyeok;Eun, Hee-Chang;Chung, Heon-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.5
    • /
    • pp.697-704
    • /
    • 2003
  • The purpose of this experimental study is to investigate the relationship of the shear behavior and the variety of width, depth and location of an opening in reinforced concrete deep beams with rectangular web openings, and to present an improved shear strength equation of those members. The main parameters considered were concrete strength(fck), shear span-to-overall depth ratio(a/h), and the size and vortical position of the web openings. Twenty five deep beams were tested under two symmetric loading-points. Test results showed that the shear behavior of deep beams with web openings was influenced by a/h and the size of opening. In addition, the KCI shear design provision is a tendency to be more unconservative according to the increase in a/h and the area-ratio of opening to shear span(Ao/Ash). Based on the concrete strut action of top and bottom member of an opening and the tie action of longitudinal reinforcement, a proper design equation which closely predicts the capacity of deep beams with rectangular openings is developed.

A Study on Rotary Bending Fatigue Strength of the $CO_2$ Gas Welded Joint in Air and Sea Water ([$CO_2$] 용접이음재의 대기 및 해수중에서의 회전굽힘 피로강도에 관한 연구)

  • S.W. Kang;S.Y. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.2
    • /
    • pp.118-126
    • /
    • 2000
  • TMCP steel has been widely used to construct ships and offshore structures. When it comes to ship and offshore structures, corrosion fatigue damages caused by sea water and fatigue occurred by wave-induced forces usually go on occurring simultaneously. So the fatigue life in corrosion environment is decreased markedly in comparison with that in air. The fatigue crack in corrosion easily initiates on welded joints of structure like as the fatigue crack in air. Therefore it is very important to study the fatigue properties of those of their welded joints as well as steel plates. In this study, rotary bending fatigue tests have been performed to investigate fatigue crack initiation and behavior of fatigue crack growth on CO2 gas weld HAZ of TMCP steel. The fatigue test used the specimens with various stress concentration factors in air and 3% NaCl solution

  • PDF

Axisymmetric Nonlinear Consolidation Analysis for Drainage-installed Deposit Considering Secondary Compression (배수재가 설치된 연약지반의 2차압축을 고려한 축대칭 비선형 압밀해석)

  • Kim Yun-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.3
    • /
    • pp.133-140
    • /
    • 2005
  • In order to accelerate the rate of consolidation settlement and gain a required shear strength for a given soft clay deposit, vertical drain method combined with a preloading technique has been widely applied. In this paper, a theory of axisymmetric nonlinear consolidation fer drainage-installed deposit, which considers secondary compression (or creep) during primary consolidation, as well as the variations of compressibility and permeability during the consolidation process, has been developed. A computer program named AXICON based on Hypothesis B fur the analysis of axisymmetric nonlinear consolidation was developed by adopting finite difference method. The results of AS(ICON were compared with Hansbo's solution based on Hypothesis A, as well as in-situ settlements and pore pressures measured in test embankment of Ska-Edeby. The results indicated that Hypothesis A usually underestimated the in-situ settlement and Hypothesis B was considered to be logically correct. It was also shown that one may able to appropriately predict the real in-situ behaviors using the proposed program.

Study on Hydration Heat Analysis of Pier Foundation-Column Using Low Heat Concrete (저발열 콘크리트를 사용한 교각 기초-기둥의 수화열 해석에 관한 연구)

  • Jeon, Joong-Kyu;Kim, Sun-Gil;Jeon, Chan-Ki;Kim, Ki-Hyung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.3
    • /
    • pp.217-224
    • /
    • 2014
  • This study carried out to evaluate the hydration heat analysis and fundamental characteristics such as air content, slump and compressive strength for field application of low heat concrete with premixed cement. The results of experiment show that low heat concrete with premixed cement have sufficient performances on the workability and compressive strength. In addition, hydration heat analysis shows that low heat concrete with premixed cement make sure of target thermal cracking index. Therefore, it is desirable to apply the low heat concrete with premixed cement on pier foundation-column.