• Title/Summary/Keyword: 설계기준치

Search Result 130, Processing Time 0.032 seconds

Applicability Review of Street Dimensional Data Survey Using Point Clouds Generated from Drone Photogrammetry (드론 항공사진측량 기반 포인트 클라우드 데이터를 활용한 가로환경 조사 가능성 연구)

  • Oh, Sunghoon;Kim, Myung Jo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.401-408
    • /
    • 2021
  • With the proposal of amendments to the Pedestrian Safety Act in 2021, when the amendment bill is passed in the near future, a general dimensional investigation of the sidewalks' physical condition, which is the basis of pedestrian safety, is expected to be legislated and made mandatory. Therefore, this study presented a affordable methodology for street environment survey using entry-level drones and examined the feasibility of conducting a complete survey of pedestrian paths by local governments nationwide. To this end, various street facilities in the experimental site were measured to compare and analyze the accuracy of the point cloud data. As a result of the analysis, it was found that the measurement error range satisfies the public surveying guidelines. If the methodology presented in this study is applied, it is expected that individual local governments will be able to make a significant contribution to monitoring the physical conditions of streets to improve the pedestrian environment in the near future.

Size Distribution and Physicochemical Characteristics of MSW for Design of Its Mechanical Biological Treatment Process (폐기물전처리(MBT)시설 설계를 위한 생활폐기물의 입도분포 및 물리화학적 특성에 관한 연구)

  • Park, Jin-Kyu;Song, Sang-Hoon;Jeong, Sae-Rom;Jung, Min-Soo;Lee, Nam-Hoon;Lee, Byoung-Chul
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.1
    • /
    • pp.62-69
    • /
    • 2008
  • There has been a recent trend in Korea that treatments for combustible wastes among municipal solid waste (MSW) by those methods, such as incineration and landfill are restricted as much as possible and Mechanical Biological Treatment (MBT) are encouraged actively in order to promote resource recovery. To build and operate properly these facilities, the physicochemical characteristics of MSW should be analyzed precisely beforehand. In particular, designing a crusher or separator properly which is the main process in MBT facilities of MSW. require the information on the size distribution characteristics of MSW, but they are nor sufficient in the qualities and quantities yet as of now. Accordingly, this study aims to evaluate size distribution characteristics of MSW and its physicochemical characteristics by size. The samples of MSW were collected from detached dwelling area, apartment area, business area, and commercial area of A city in Korea. According to the result of analysis, paper records 29.78~60.02% by wet weight basis, so it was the most regardless of the regions where the wastes were generated. And in terms of element analysis, Carbon(C) was 34.77~44.39%, the largest friction, and Oxygen(O) was the next occupying 19.46~33.71%. As indices of RDFs, Chlorine(Cl) was 0.39~0.83%, so it was less than the standard, 2.0%(by dry weight basis); moreover, Sulfur(S) did not exceed the standard, 0.6%, either. In the size distribution of MSW, waste fraction ranging 50~80mm in diameter was the most in combustible waste while 30~50mm was in incombustible waste.

  • PDF

Design and Operation of the Rainwater-Greywater Hybrid System : SNU No. 39 Building (빗물-저농도 오수 하이브리드 시스템의 설계 및 운전 평가 : 서울대 39동)

  • Shim, In-tae;Park, Hyun-ju;Kim, Tschung-il;Jung, Sung-un;Han, Moo-young;Namkung, Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.676-682
    • /
    • 2016
  • In this study, rainwater-greywater hybrid system was installed and operated for 1 year in order to evaluate its water quantity, water quality, and economic efficiency in building no. 39. This system was expected to overcome each disadvantages of and maximize each advantages. Low-greywater that was washed up from shower room was treated by MBR (Membrane Bioreactor) and ozone oxidation. Rainwater that was collected from the rooftop was stored in a reservoir, and then transferred to the storage tank that was mixed with treated greywater. After 1 year operating in building no. 39, rainwater and greywater was used to supply $2,599m^3$ of toilet flushing water. In terms of water quality, rainwater was satisfied far the greywater reuse standards except for E.coli. Moreover, low greywater quality was acceptable except for E. coli, BOD, SS, and turbidity. In addition, economic analysis was obtained from benefit-cost ratio (B/C) with 1.11. It implies that the feasibility of the project was reasonable. Furthermore, various research and policy to improve the economic efficiency of water recycling facilities is required to expand the use of water recycling facilities.

Fabrication and Reliability Properties of Optical Fiber Sensor Cable for Detecting Intruders (침입자 감지용 광섬유 센서 케이블 제작 및 신뢰성 특성)

  • Kim, Jun-Hyong;Jung, Yoon-Seok;Sung, Tae-Kyung;An, Bo-Young;Park, In-Chul;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.208-208
    • /
    • 2009
  • 최근 광섬유 센서기술의 수요는 전 산업분야에 걸쳐 높아지고 있으며, 이에 비례하여 기업 간, 국가 간 경쟁이 첨예화되고 있다. 또한 소형화, 경량화, 고성능화 센서에 대한 요구도 높아지고 있어 종래의 각종 센서들의 형태와 개선을 위한 연구개발이 매우 활발하게 전개되고 있으므로 이를 대체할 수 있는 광섬유 센서의 수요가 급격히 늘어날 전망이다. 기존 침입자 감지 시스템은 태풍, 낙뢰, 폭설, 폭우 등의 기상변화나 지반 흔들림, 통행차량 진동 및 전자기 간섭 등에 영향을 받아 오작동, 오경보가 빈번히 발생된다. 이러한 문제의 해결책으로 광섬유 센서 케이블을 이용한 시스템이 대안으로 부각되고 있다. 현재 국내에서 군부대, 공항을 중심으로 펜스와 휴전선 철책에 힘입자 감지를 위하여 도입되고 있다. 광섬유 센서 케이블을 사용하는 광망경비시스템은 광섬유 센서 케이블을 그물망 형태(광망)로 만들어 경계 지역에 설치된다. 광망경비시스템의 원리는 광섬유에 광펄스를 입사시켜 순환시키는데 침입자가 광망을 절단하거나 외력을 가할 경우 발생되는 레일리 산란에 기인하는 후방산란과 접속점과 파단점에서 생기는 반사광을 OTDR(Optical Time Domain Reflectometer)로 검출하여 침입상황 및 침입위치를 탐지한다. 그러나 이러한 침입자 감지를 위한 광망경비시스템의 핵심부품인 광섬유 센서 케이블은 기존에 전량 해외수입에 의존하고 있는 실정이며, 지금까지 국내에서 생산하기 위한 제작 기술과 노하우가 초보단계에 머물러 있다. 이러한 광섬유 센서 케이블 제작에 있어서 중요한 부분이 패키징 기술이라 할 수 있다. 이는 광섬유 센서를 일반적인 피복 구조로 패키징하게 되면, 센서 고유의 특성이 패키징 과정과 운반과정, 포설과정에서 변하게 되고 센서로써의 신뢰성이 크게 저하된다. 본 연구에서는 힘입자 감지용 광섬유 센서 케이블의 설계와 제작을 위한 제조공법을 확립하고, 이를 이용해 제작된 광섬유 센서 케이블의 신뢰성 특성을 평가하였다. 설계 제작된 광섬유 센서 케이블의 구조는 멀티모드광섬유(MMF) 에 0.9 mm Tight buffer를 코팅하고, 광심선 주위에 아라미드 얀을 삽입시킨 후 고문자 수지를 적용하여 외부 피복 (jacket)을 하였다. 제작된 광섬유 센서 케이블의 외경 측정결과 기준치 ($2.95\;{\pm}\;0.03$ mm)를 모두 만족하였고, 850 nm 파장에서의 광 손실 측정 결과 4.0 dB/km 이하였다. 또한 주요 항목의 신뢰성 특성 시험결과, 인장강도는 8~10 kg의 인장력을 갖으며 온도순환시험 ($-30^{\circ}C\;{\sim}\;+75^{\circ}C$)에서의 광 손실은 0.6 dB 이하로 나타나 침입자 감지용 광섬유 센서 케이블로 적합함을 확인할 수 있었다.

  • PDF

Assessment of a Pre-conceptual Design of a Spent PWR Fuel Disposal Container (가압경수로형 사용후핵연료 처분용기의 예비 개념설계 평가)

  • Choi, Jong-Won;Cho, Dong-Keun;Lee, Yang;Choi, Heui-Joo;Lee, Jong-Youl
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.1
    • /
    • pp.41-50
    • /
    • 2006
  • In this paper, sets of engineering analyses were conducted to renew the overall dimensions and configurations of a disposal container proposed as a prototype in the previous study. Such efforts and calculation results can provide new design variables such as the inner basket array type and thickness of the outer shell and the lid & bottom of a spent nuclear fuel disposal container. These efforts include radiation shielding and nuclear criticality analyses to check to see whether the dimensions of the container proposed from the mechanical structural analyses can provide a nuclear safety or not. According to the results of the structural analysis of a PWR disposal container by varying the diameter of the container insert, the Maximum Von Mises stress from the 102 cm-container meets the safety factor of 2.0 for both extreme and normal load conditions. This container also satisfies the nuclear criticality and radiation safety limits. This decrease in the diameter results in a weight loss of a container by $\sim20$ tons.

  • PDF

Pre-conceptual Design of a Spent PWR Fuel Disposal Container (가압경수로형 사용후핵연료 처분용기의 예비 개념설계 평가)

  • CHO Dong-Keun;CHOI Jongwon;Lee Yang;CHOI Heui-Joo;LEE Jong-Youl
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.153-162
    • /
    • 2005
  • In this Paper, sets of engineering analyses were conducted to renew the overall dimensions and configurations of a disposal container proposed as a prototype in the previous study. Such efforts and calculation results can provide new design variables such as the inner basket array type and thickness of the outer shell and the lid & bottom of a spent nuclear fuel disposal container. These efforts include radiation shielding and nuclear criticality analyses to check to see whether the dimensions of the container proposed from the mechanical structural analyses can provide a nuclear safety or not. According to the results of the structural analysis of a PWR disposal container by varying the diameter of the container insert, the Maximum Von Mises stress from the 102 cm container meets the safety factor of 2.0 for both extreme and normal load conditions. This container also satisfies the nuclear criticality and radiation safety limits. This decrease in the diameter results in a weight loss of a container by ${\~}$20 tons.

  • PDF

A Study on the Cause of Noise and Vibration of an Elevator (엘리베이터 소음 및 진동의 원인에 관한 연구)

  • 이성춘;김준호;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.94-99
    • /
    • 1994
  • 최근 인구의 과밀화와 이에 따른 지가의 상승 등으로 대표적인 주거용 빌딩인 아파트의 고층화가 급속하게 진행되고 있고 아파트에 설치되는 엘리베이터도 점차 대형화, 고속화 되고 있다. 실례로 15층 아파트의 경우 11인승, 60m/min의 엘리베이터가 일반적으로 사용되는 반면, 20층 아파트의 경우 17인승, 90m/min이 주로 사용된다. 이와 같이 엘리베이터의 용량과 운행 속도가 증가함에 따라 필연적으로 소음 및 진동 문제가 발생하게 된다. 특히 아파트의 경우 침실, 공부방 등 고도의 정숙을 요하는 생활 공간이 많고, 내부 공간의 활용도를 높이기 위하여 이들 방들이 엘리베이터 기계실 또는 운행 통로와 직접 접하여 있는 경우도 있어 이 경우 소음, 진동 문제는 아주 심각한 문제로 대두된다. 본 연구소가 측정한 방에 의하면 S신도시 L아파트의 경우 아파트 최상층 방에서 실내 소음도가 46dB(A), 벽의 진동가속도가 3.4mm/s$^{2}$(RMS)으로 나타났다. 진동의 경우 생활에 직접적인 악영향을 미칠 수준은 아니지만 소음의 경우 ASHRAE 권장 주택소음 기준치가 35dB(A) 이하임ㅇㄹ 감안하면 주거에 곤란한 수준이다. 수년전, 고층 아파트가 보급될 초기에는 아파트에 엘리베이터가 설치되어있다는 그 자체만으로 충분한 장점이 되어 다소음 소음, 진동문제는 큰 불만거리가 되지 않았지만 엘리베이터가 보편화된 지금에는 엘리베이터의 편리성만으로는 점점더 크게 요구되는 정숙성이 보상되지 않는다. 따라서 전반적인 아파트의 소음, 진동 문제에 큰 비중을 차지하는 엘리베이터에 의한 소음, 진동에 관하여 체계적인 연구가 필요하다. 이에 본고에서는 엘리베이터에 의한 아파트의 소음 및 진동에 관하여 그 현황, 원인 그리고 대책에 관한여 논하고자 한다.감 방법을 연구하였고, T.Sakai는 5자유도 모델을 이용하여 엔진 공회전시 발생하는 치타음에 대해 이론과 실험을 통해 해석하고, 엔진 회전수 변동, 클러치 특성, 변속기의 드래그(drag) 토크의 영향과 치타음 저감을 위한 개선된 클러치 특성을 제시하였다. 이 외에도 Thomas C.T.와 E.P.Petkus는 특정 차량에 대한 동력전달계의 비틀림 진동 현상에 대해 연구하였다. 이러한 연구들로 볼 때, 자동차 동력전달계에서 발생하는 진동은 이론과 실험을 통해 그 해석이 가능하며 설계에 매우 유용하게 이용되고 있음을 알 수 있다. 따라서, 본 연구는 4 실린더 4 싸이클 1.5 L 엔진을 장착한 경승용차의 실차 주행실험을 통해 가속 페달의 급조작에 따른 차체의 종진동 현상을 측정하고, 엔진-변속기-타이어-차체의 반환정계 4자유도 진동모델로 시뮬레이션을 수행하여 실차 주행실험의 결과치와 비교, 분석한 후 클러치 비틀림 특성을 비롯한 자동차 동력전달계의 각 설계인자들이 차체의 종진동에 어떠한 영향을 미치는가를 해석하고자 한다.be presented.LIFO, 우선 순위 방식등을 선택할 수 있도록 확장하였다. SIMPLE는 자료구조 및 프로그램이 공개되어 있으므로 프로그래머가 원하는 기능을 쉽게 추가할 수 있는 장점도 있다. 아울러 SMPLE에서 새로이 추가된 자료구조와 함수 및 설비제어 방식등을 활용하여 실제 중형급 시스템에 대한 시뮬레이션 구현과 시스템 분석의 예를 보인다._3$", chain segment, with the activation energy of carriers from the shallow trap with 0.4[eV], in he amorphous regions.의 증발산율은 우기의 기상자료를 이용하여 구한 결과 0.05 - 0.1

  • PDF

Damage Evaluation of Track Components for Sleeper Floating Track System in Urban Transit (도시철도 침목플로팅궤도 궤도구성품의 손상평가)

  • Choi, Jung-Youl;Kim, Hak-Seon;Han, Kyung-Sung;Jang, Cheol-Ju;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.387-394
    • /
    • 2019
  • In this study, in order to evaluate the damage and deterioration of the track components of sleeper floating track (STEDEF), the field samples(specimens) were taken from the serviced line over 20 years old, and the track components were visually inspected, and investigated by laboratory tests and finite element analysis. As a result of visual inspection, the damage of the rail pad and fastener was slight, but the rubber boot was worn and torn at the edges of bottom. The resilience pads were clearly examined for thickness reduction and fatigue hardening layer. As a result of spring stiffness test of rail pad and resilience pad, the deterioration of rail pad was insignificant, but the deterioration of resilience pad exceeded design standard value. Therefore resilience pad was directly affected by train passing tonnage. As a result of comparing the deterioration state of the field sample and the numerical analysis result, the stress and displacement concentration position of the finite element model and the damage position of the field sample were coincident.

Case Study of Improvement against Leakage of a Sea Dike under Construction (해안제방 시공 중 해수유입에 대한 차수보강 사례분석)

  • Han, Sang-Hyun;Yea, Geu-Guwen;Kim, Hong-Yeon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.2
    • /
    • pp.95-103
    • /
    • 2015
  • In this study, the causes and countermeasures for the leakage of a sea dyke under construction are analyzed. In general, the seabed ground is clearly divided from the embankment but a lot of parts show abnormal zones with low resistivity from the results of electric resistivity survey. Hence the causes of the leakage are considered as following: three-dimensional shear strain behavior, irregular compulsory replacement of the soft seabed ground with low strength and quality deterioration of the waterproof sheets during the closing process. The improvement method is determined by considering the constructability in the seawater and its velocity condition, durability, economic feasibility, similar application cases and so on. Consequently, a combination of low slump mortar and slurry grouting and injection method is selected as an optimum combination. Mixing ratio and improvement pattern are determined after drilling investigation and pilot test. The improvement boundary is separated into general and intense leakage area. The construction is performed with each pattern and the improvement effects are confirmed. The confirmed effects with various tests after completion show tolerable ranges for all of the established standards. Finally, various issues such as prediction of length of the waterproof sheet, installation of it against seawater velocity, etc. should be considered when sea dykes are designed or executed around the western sea which has high tide difference.

Safety Simulation of Therapeutic I-131 Capsule Using GEANT4 (GEANT4를 이용한 치료용 I-131 캡슐의 안정성 시뮬레이션)

  • Jeong, Yeong-Hwan;Kim, Byung-Cheol;Sim, Cheol-Min;Seo, Han-Kyung;Gwon, Yong-Ju;Han, Dong-Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.57-61
    • /
    • 2014
  • Purpose Iodine (I-131) is one of the most widely used radioactive isotopes for therapeutic in the field of nuclear medicine. Therapeutic I-131 capsule is made out of lead to shield high energy radiation. Accurate dosimetry is necessarily required to perform safe and effective work for relative workers. The Monte Carlo method is known as a method to predict the absorbed dose distribution most accurately in radiation therapy and many researchers constantly attempt to apply this method to the dose calculation of radiotherapy recently. This paper aims to calculate distance dependent and activity dependent therapeutic I-131 capsule using GEANT4. Materials and Methods Therapeutic capsules was implemented on the basis of the design drawings. The simulated dose was determined by generating of gamma rays of energy to more than 364 keV. The simulated dose from the capsule at the distance of 10 cm and 100 cm was measured and calculated in the model of water phantom. The simulated dose were separately calculated for each position of each detector. Results According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of therapeutic I-131 capsule should not exceed 2.0 mSv/h and 0.02 mSv/h, respectively. The simulated doses turned out to be less than the limit, satisfying the domestic regulation. Conclusion These simulation results may serve as useful data in the prediction of hands dose absorbed by I-131 capsule handling. GEANT4 is considered that it will be effectively used in order to check the radiation dose.

  • PDF