• Title/Summary/Keyword: 선 자세

Search Result 373, Processing Time 0.023 seconds

Implementation of a Kinematic Network-Based Single-Frequency GPS Measurement Model and Its Simulation Tests for Precise Positioning and Attitude Determination of Surveying Vessel (동적네트워크 기반 단일주파수 GPS 관측데이터 모델링을 통한 측량선의 정밀측위 및 자세각결정 알고리즘 구현과 수치실험에 의한 성능분석)

  • Hungkyu, Lee;Siwan, Lyu
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.2
    • /
    • pp.131-142
    • /
    • 2015
  • In order to support the development of a cost-effective river bathymetric system, this research has focused on modeling GPS observables, which are obtained by array of five single-frequency receivers (i.e., two references and three rovers) to estimate the high accurate kinematic position, and the surveying vessel altitude. Also, by applying all GPS measurements as multiple-baselines with constraining rover baselines, we derived the socalled ‘kinematic network model.’ From the model, the integer-constrained least-squares (LS) for position estimation and the implicit LS for attitude determination were implemented, while a series of simulation tests with respect to the baseline lengths around 2km performed to demonstrate its accuracy analysis. The on-the-fly (OTF) ambiguity resolution tests revealed that ninety-nine percents of time-to-fix-first ambiguity (TTFF) can be decided in less than two seconds, when the positioning accuracy of ambiguity-fixed solutions was assessed as the greater than or equal to one and two centimeters in horizontal and vertical, respectively. Comparing to the GPS-derived attitudes, the achievable accuracy gradually descended in sequence of yaw, pitch and roll due to the antenna geometric configuration. Furthermore, the RMSE values for the baseline lengths of three to six meters were within ±1′for yaw, and less than ±10′and ±20′for pitch and roll, respectively, but those of between six to fifteen meters were less than ±1′for yaw, ±5′for pitch, and ±10′for roll.

A Design and Implementation of Fitness Application Based on Kinect Sensor

  • Lee, Won Joo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.3
    • /
    • pp.43-50
    • /
    • 2021
  • In this paper, we design and implement KITNESS, a windows application that feeds back the accuracy of fitness motions based on Kinect sensors. The feature of this application is to use Kinect's camera and joint recognition sensor to give feedback to the user to exercise in the correct fitness position. At this time, the distance between the user and the Kinect is measured using Kinect's IR Emitter and IR Depth Sensor, and the joint, which is the user's joint position, and the Skeleton data of each joint are measured. Using this data, a certain distance is calculated for each joint position and posture of the user, and the accuracy of the posture is determined. And it is implemented so that users can check their posture through Kinect's RGB camera. That is, if the user's posture is correct, the skeleton information is displayed as a green line, and if it is not correct, the inaccurate part is displayed as a red line to inform intuitively. Through this application, the user receives feedback on the accuracy of the exercise position, so he can exercise himself in the correct position. This application classifies the exercise area into three areas: neck, waist, and leg, and increases the recognition rate of Kinect by excluding positions that Kinect does not recognize due to overlapping joints in the position of each exercise area. And at the end of the application, the last exercise is shown as an image for 5 seconds to inspire a sense of accomplishment and to continuously exercise.

Optimal Trajectory Design of Descent/Ascent phase for a Lunar Lander With Considerable Sub-Phases (Sub-Phase를 고려한 달착륙선의 Descent/Ascent phase 최적 궤적 생성)

  • Jo, Sung-Jin;Min, Chan-Oh;Lee, Dae-Woo;Cho, Kyeum-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.12
    • /
    • pp.1184-1194
    • /
    • 2010
  • The descent and ascent phases for a lunar lander are composed of several phases. Accordingly, the constraints and control values adequate for each phase are required in order to generate optimal lander's trajectory. The optimal trajectories for descent and ascent phases are generated by the cost function to minimize fuel consumption & attitude variation rates. In this paper, the optimal control problem to make trajectory uses Gauss pseudo-spectral method which is one of the direct approach method. This problem generates lander's reference trajectory, states and controls.

The Effects of Sensory Integrative Therapy on Vestibulo-Proprioceptive Sensory Processing of Children With Asperger Syndrome (감각통합치료가 아스퍼거 아동의 전정.고유감각 처리능력에 미치는 효과)

  • Kim, Eun-Sung;Kim, Kyeong-Mi
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.6 no.1
    • /
    • pp.35-46
    • /
    • 2008
  • Objective : This study verifies the effects of sensory integrative (SI) therapy on vestibular- and proprioceptive sensory (BPS) processing ability of a child with Asperger Syndrome (AS). Method : A boy who is 11 years and 2 months old took the Functional Independence Measure for Children (Wee-FIM), Canadian Occupational Performance Measure (COPM), Short Sensory Profile, Bruininks-Oserestky Test of Motor Proficiency-2 (BOT-2), and Test of Playfulness (ToP) for the baseline. The child participated in 3 evaluation sessions and 8 therapy sessions based on the AB research design. Duration of each session is 50 min and the therapy session is divided into 40 minutes for treatment and 10 minutes for evaluation. Since the vestibular sense and proprioception build up one's ability of postural control, several tests were employed to evaluate the child' postural control as outcome measure; distance from front leg of chair to heel of the child with sitting (C-H distance), angle between trunk and thigh (hip joint angle) with sitting, and the 'prone-extension posture' which is a subtest of Clinical Observation of Motor and Postural Skill (COMPS) to examine postural control embodied with integration of reflex and BPS processing. Result : During the therapy, average data of the C-H distance is decreased from 27.33cm to 11.69cm, average data of the hip joint angle is also decreased from $43.3^{\circ}$ to $20^{\circ}$, and average time for the prone-extension posture is increased from 13.15seconds to 24.84seconds. Conclusion : This result indicates that the ability to postural control in sitting and to maintain the prone-extension posture can be improved by sensory integrative therapy, with enhanced BPS processing.

  • PDF

The Convergence Effects on the Grip Strength in Change of Shoulder Angle on Horizontal Plane (수평면에서 어깨각도변화에 따른 여대생의 악력에 대한 융복합적 연구)

  • Seo, Kyo-Chul;Park, Seung-Hwan;Cho, Mi-Suk
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.5
    • /
    • pp.81-86
    • /
    • 2020
  • The Purpose of this study is analysis characteristic of grasping power with each different shoulder horizontal angle. Twenty female university students with no shoulder dysfuction participated subject in three different positions of shoulder horizontal flexion with standing posture, shoulder 0° flexion, elbow 90° flexion, forearm 90° pronation, different positions is followed : shoulder 0° horizontal adduction shoulder 40° horizontal adduction, shoulder 40° horizontal abduction. The One-way repeated ANOVA test was used to determine the different in grip strength on three shoulder horizontal positions. On the average, in the hand grip strength, the horizontal neutral position is higher than horizontal adduction position with significant value. In particular, shoulder horizontal aduction was measured lowest grip strength between three positions.

Clinical Usefulness of Implanted Fiducial Markers for Hypofractionated Radiotherapy of Prostate Cancer (전립선암의 소분할 방사선치료 시에 위치표지자 삽입의 유용성)

  • Choi, Young-Min;Ahn, Sung-Hwan;Lee, Hyung-Sik;Hur, Won-Joo;Yoon, Jin-Han;Kim, Tae-Hyo;Kim, Soo-Dong;Yun, Seong-Guk
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.91-98
    • /
    • 2011
  • Purpose: To assess the usefulness of implanted fiducial markers in the setup of hypofractionated radiotherapy for prostate cancer patients by comparing a fiducial marker matched setup with a pelvic bone match. Materials and Methods: Four prostate cancer patients treated with definitive hypofractionated radiotherapy between September 2009 and August 2010 were enrolled in this study. Three gold fiducial markers were implanted into the prostate and through the rectum under ultrasound guidance around a week before radiotherapy. Glycerin enemas were given prior to each radiotherapy planning CT and every radiotherapy session. Hypofractionated radiotherapy was planned for a total dose of 59.5 Gy in daily 3.5 Gy with using the Novalis system. Orthogonal kV X-rays were taken before radiotherapy. Treatment positions were adjusted according to the results from the fusion of the fiducial markers on digitally reconstructed radiographs of a radiotherapy plan with those on orthogonal kV X-rays. When the difference in the coordinates from the fiducial marker fusion was less than 1 mm, the patient position was approved for radiotherapy. A virtual bone matching was carried out at the fiducial marker matched position, and then a setup difference between the fiducial marker matching and bone matching was evaluated. Results: Three patients received a planned 17-fractionated radiotherapy and the rest underwent 16 fractionations. The setup error of the fiducial marker matching was $0.94{\pm}0.62$ mm (range, 0.09 to 3.01 mm; median, 0.81 mm), and the means of the lateral, craniocaudal, and anteroposterior errors were $0.39{\pm}0.34$ mm, $0.46{\pm}0.34$ mm, and $0.57{\pm}0.59$ mm, respectively. The setup error of the pelvic bony matching was $3.15{\pm}2.03$ mm (range, 0.25 to 8.23 mm; median, 2.95 mm), and the error of craniocaudal direction ($2.29{\pm}1.95$ mm) was significantly larger than those of anteroposterior ($1.73{\pm}1.31$ mm) and lateral directions ($0.45{\pm}0.37$ mm), respectively (p<0.05). Incidences of over 3 mm and 5 mm in setup difference among the fractionations were 1.5% and 0% in the fiducial marker matching, respectively, and 49.3% and 17.9% in the pelvic bone matching, respectively. Conclusion: The more precise setup of hypofractionated radiotherapy for prostate cancer patients is feasible with the implanted fiducial marker matching compared with the pelvic bony matching. Therefore, a less marginal expansion of planning target volume produces less radiation exposure to adjacent normal tissues, which could ultimately make hypofractionated radiotherapy safer.

Analysis of Lower Extremity Muscle Activation According to Squat Type during Whole-Body Vibration (전신진동 운동 시 스쿼트 형태에 따른 하지근육의 근활성 효과 분석)

  • Lee, Dae-Yeon
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.10
    • /
    • pp.371-376
    • /
    • 2018
  • The purpose of this study is to clarify the effects of whole-body vibration and to provide scientific basis for effective exercise by analyzing the differences in lower extremity muscle activation according to squat position during whole body vibration. In this study, muscle activation during whole-body vibration was measured in 10 healthy males in their 20s with no orthopedic conditions during standing posture, deep squat, half squat, and heel raise squat. Muscle activation was compared by measuring the root mean square (RMS) with electromyography electrodes attached to lateral gastrocnemius, tibialis anterior, vastus lateralis, and biceps femoris. The vibration intensity was applied in combinations of the volumes of 50 and 80 and the frequencies of 10, 25, and 40 Hz in each posture. The results showed that there were differences in muscle activations of external gastrocnemius, tibialis anterior, and vastus lateralis among the position(p<.05). The heal raise squat was found to have a high muscle activation effect.

A Study on the Hydrodynamic Performance of High-Speed Vessel with Trim Tab Using Full-Scale CFD Simulation (실선 스케일 CFD 해석 기반 트림 탭이 부착된 고속선의 유체동역학적 성능 분석)

  • Lee, Jonghyeon;Park, Dong-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.656-665
    • /
    • 2021
  • In this study, trim tabs were attached to end of stern hull of a small high-speed vessel of length approximately 10 m and Froude number 1.0 to improve resistance performance and passenger comfort. Before computational fluid dynamics (CFD) simulations to assess the performance according to various geometries of the trim tab, the scale effect had been found through a previous study, so full-scale simulations were performed. The trim tab chord length was set to 0.5 %, 1.0 % and 1.5 % of LPP, and its angle to base line was varied in intervals of 5°. It decreased trim by stern and flotation: the greater the angle and length, the greater was the effect. Then it had pressure resistance decreased and shear resistance increased, and reduction ratio of total resistance varied accordingly. The results of this study indicated that the resistance performance was improved about 27 % at optimal running attitude that was the trim by stern about 1.5°.

Study on the Differences in the Results of Body Shape Test According to the Position of the Two Feet and the Usefulness of the Neck and Body Motion Image Test (두 발의 위치에 따른 체형검사 결과 차이와 체간신전 동작 이미지 검사의 유용성 연구)

  • Chang, Wan Song;Kim, Song Ja;Ryu, Seo Won;Lim, Duk Joon;Jung, Moon Young
    • Journal of Naturopathy
    • /
    • v.9 no.1
    • /
    • pp.22-26
    • /
    • 2020
  • Purposes: The purposes of this study were to investigate the relationship between the standing position of the subject and the normal standing position(NSP) and the straight standing position(SSP) and to investigate the possibility of different body shape test results depending on the status of the image inspection apparatus. Methods: The images of the NSP and SSP were compared with each other by body line BLS system. Results: At the time of examination, the position of the camera was captured at a position 2.3 m vertically from the posterior position 45 cm behind the subject. This is a privacy protection method for covering the breast of the subject. Results: The physiological characteristics of the anatomical position of the body align image test are the living body. NSP and SSP tests showed different shapes of the pelvis AS(antero-supero) and pelvis rotation in the transverse plane. Shoulder and arm displacement was observed in the trunk extension image capture. Conclusions: In the body alignment test, the pelvis position test images of NSP and SSP are evaluated differently for pelvis rotation, AS, and PS. At the extension position of the trunk, a test of the maximal extension range showed that the left and right shortening of the shoulder anterior muscles could be observed. Inducing and testing the trunk extension is also useful.