• Title/Summary/Keyword: 선형 개발

Search Result 3,512, Processing Time 0.034 seconds

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.

KOREAN MARS MISSION DESIGN USING KSLV-III (KSLV-III를 이용한 한국형 화성 탐사 임무의 설계)

  • Song, Young-Joo;Yoo, Sung-Moon;Park, Eun-Seo;Park, Sang-Young;Choi, Kyu-Hong;Yoon, Jae-Cheol;Yim, Jo-Ryeong;Choi, Joon-Min;Kim, Byung-Kyo
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.4
    • /
    • pp.355-372
    • /
    • 2006
  • Mission opportunities and trajectory characteristics for the future Korean Mars mission have designed and analyzed using KSIV-III(Korea Space Launch Vehicle-III). Korea's first space center, 'NARO space center' is selected as a launch site. For launch opportunities, year 2033 is investigated under considering the date of space center's completion with KSLV series development status. Optimal magnitude of various maneuvers, Trans Mars Injection (TMI) maneuver, Trajectory Correction Maneuver (TCM), Mars Orbit Insertion (MOI) maneuver and Orbit Trim Maneuver(OTM), which are required during the every Mars mission phases are computed with the formulation of nonlinear optimization problems using NPSOL software. Finally, mass budgets for upper stage (launcher for KSIV-III and spacecraft are derived using various optimized maneuver magnitudes. For results, daily launch window from NARO space center for successful Korean Mars mission is avaliable for next 27 minutes starting from Apr. 16. 2033. 12:17:26 (UTC). Maximum spacecraft gross mass which can delivered to Mars is about 206kg, with propellant mass of 109kg and structure mass of 97kg, when on board spacecraft thruster's Isp is assumed to have 290 sec. For upper stage, having structure ratio of 0.15 and Isp value of 280 sec, gross mass is about 1293kg with propellant mass of 1099kg and structure mass of 194kg. However, including 10% margins to computed optimal maneuver values, spacecraft gross mass is reduced to about 148kg with upper stage's mass of 1352kg. This work will give various insights, requiring performances to developing of KSIV-III and spacecraft design for future Korean Mars missions.

Development of Source Template ICRT Dose Planning Software for Uterine Cervix Using the HDR: $^{192}Ir$ (강내조사를 위한 고선량률 근접조사 선원맞춤형 선량계획)

  • Choi, Tae-Jin;Oh, Young-Kee;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.112-118
    • /
    • 2009
  • The source position and source dwelling time in a given source arrangement in the applicators is very high effect to determine the expose time which in general is derived from the brachytherapy planning system. In high dose rate (HDR) intracavitary radiation therapy (ICRT), the treatment is often performed in based out-patient during the whole fractionation irradiations. However, the patient should be waited on coutch for ICR treatment in first start fraction as unconvinent and immobilized state until perform the dose plannings. In our experiments, the HDR source contributed dose for$55.89{\pm}4.20%$ for straight tandem source, $38.14{\pm}4.46%$ for the right ovoid soucre on the fornix and$5.97{\pm}0.50%$ for left ovoid source. It also showed the $60.33{\pm}6.53%$ for the tandem, $33.10{\pm}6.74%$ for right ovoid and $6.58{\pm}0.30%$ for the left ovoid source in 10 degrees of applicator. The authors designed the source template dose planning software for ICRT of uterine cervix results average $-0.55{\pm}2.15%$ discrepancy of the full charged brachytherapy dose planning. Developed Source temperate ICRT plaanning software guide a minimized the complains and operating times within a ${\pm}3%$ of dose discrepancies.

  • PDF

Implementation of Radiotherapy Educational Contents Using Virtual Reality (가상현실 기술을 활용한 방사선치료 교육 콘텐츠 제작 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.409-415
    • /
    • 2018
  • The development of smart devices has brought about significant changes in daily life and one of the most significant changes is the virtual reality zone. Virtual reality is a technology that creates the illusion that a 3D high-resolution image has already been created using a display device just like it does in itself. Unrealized subjects are forced to rely on audiovisual materials, resulting in a decline in the concentration of practices and the quality of classes. It used virtual reality to develop effective teaching materials for radiology students. In order to produce a video clip bridge using virtual reality, a radiology clinic was selected to conduct two exposures from July to September 2017. The video was produced taking into account the radiology and work flow chart and filming was carried out in two separate locations : in the computerized tomography unit and in the LINAC room. Prior to filming the scenario and the filming route were checked in advance to facilitate editing of the video. Modeling and mapping was performed in a PC environment using the Window XP operating system. Using two leading virtual reality camera Gopro Hero, CC pixels were produced using a 4K UHD, Adobe, followed by an 8 megapixel resolution of $3,840{\times}2,160/4,096{\times}2,160$. Total regeneration time was performed in about 5 minutes during the production of using virtual reality to prevent vomiting and dizziness. Currently developed virtual reality radiation and educational contents are being used to secure the market and extend the promotion process to be used by various institutions. The researchers will investigate the satisfaction level of radiation and educational contents using virtual reality and carry out supplementary tasks depending on the results.

Development of Menu Labeling System (MLS) Using Nutri-API (Nutrition Analysis Application Programming Interface) (영양분석 API를 이용한 메뉴 라벨링 시스템 (MLS) 개발)

  • Hong, Soon-Myung;Cho, Jee-Ye;Park, Yu-Jeong;Kim, Min-Chan;Park, Hye-Kyung;Lee, Eun-Ju;Kim, Jong-Wook;Kwon, Kwang-Il;Kim, Jee-Young
    • Journal of Nutrition and Health
    • /
    • v.43 no.2
    • /
    • pp.197-206
    • /
    • 2010
  • Now a days, people eat outside of the home more and more frequently. Menu labeling can help people make more informed decisions about the foods they eat and help them maintain a healthy diet. This study was conducted to develop menu labeling system using Nutri-API (Nutrition Analysis Application Programming Interface). This system offers convenient user interface and menu labeling information with printout format. This system provide useful functions such as new food/menu nutrients information, retrieval food semantic service, menu plan with subgroup and nutrient analysis informations and print format. This system provide nutritive values with nutrient information and ratio of 3 major energy nutrients. MLS system can analyze nutrients for menu and each subgroup. And MLS system can display nutrient comparisons with DRIs and % Daily Nutrient Values. And also this system provide 6 different menu labeling formate with nutrient information. Therefore it can be used by not only usual people but also dietitians and restaurant managers who take charge of making a menu and experts in the field of food and nutrition. It is expected that Menu Labeling System (MLS) can be useful of menu planning and nutrition education, nutrition counseling and expert meal management.

Radiosurgery with Linac Based Photon Knife in Cerebral Arteriovenous Malformation (선형가속기를 이용한 Photon Knife 방사선수술에 의한 뇌동정맥기형의 치료)

  • Kim, Jin-Hee;Choi, Tae-Jin
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • Purpose : The purpose of this study was to analyze the effect of a Linear accelerator based Photon Knife Radiosurgery System developed by the staff of Keimyung University Dongsan Medical Center for the treatment of cerebral arterlovenous malformation Material and Methods : Between December 1993 and October 2000, 30 patients with cerebral arteriovenous malformation (AVM) were treated with the Linac based Photon knife Radlosurgery System In the Department of Therapeutlc Radiology at Keimyung University Dongsan Medical Center. The median age was 34, ranging from 7 to 63 years, with a 2 : 1 male to female ratio. The locations of the AVM nidi were the frontal lobe (motor cortex), parletal lobe, and the thalamus, In that order. The diameters of the AVM nidi ranged 1.2 to 5.5 cm with a mean on 2.9 cm, and target volumes of between 0.5 and 20.5 cc, with a mean of 5.8 cc. The majority of patients received radiation doses of between 1,500 and 2,500 cGy, w14h a mean of 2,000 cGy, at 80% the isodose line. Twenty-five patients were treated with one isocenter, 4 with two, and 1 with four. The follow-up radiological evaluations were peformed with cranial computed tomogram (CT) or MRI between 6 month and one year interval, and if the AVM nidus had completely disappeared in the CT or MRI, we confirmed thls was a complete obliteration, with a cerebral or magnetic resonance angiogram (MRA). The median iollow-up period was 39 months with a range of 10 to 103 months. Results : Twenty patients were radloiogicaiiy followed up ior over 20 months, with complete obliteration observed in 14 (70%). According to the maximal diameter, all four of the small AVM (<2 cm) completely obliterated, 8 of the 10 patients with a medium AVW (2~3 cm) showed a complete obliteration, and two showed partial obliteration. Among the patients with a large AVM (>3 cm), only one showed complete obliteration, and S showed partial obliteration, but 3 oT these underwent further radiosurgery 3 years later. One who followed up for 20 months fellowing further radiosurgery eventually showed complete obliteration. Ten patients with seizure symptoms had no recurrent seizure due to radiosurgery and medication. One of the eleven patients who suffered intracranlal bleeding developed further bleeding at 9 and 51 months fellowing the radiosurgery although complete obliteration was eventually observed and the patient was managed in hospital then recovered. No patient suffered severe complications fellowing the radiosurgery. Conclusion : The radiosurgery with Linac-based Photon knife radiosurgery system, developed by the staff at our hospital, is a safe and effective treatment for AVM patients having diameters or volumes of less than 3 cm or 10 cm$^{3}$, respectively, located In Inoperable areas or who refused neurosurgery. We suggest that staged AVM radiosurgery may initially be considered, if the AVM target volume is above 10 cm$^{3}$

Growth and Fresh Bulb Weight Model in Harvest Time of Southern Type Garlic Var. 'Namdo' based on Temperature (온도에 따른 난지형 마늘 '남도'의 생육과 수확기 구생체중 모델 개발)

  • Wi, Seung Hwan;Moon, Kyung Hwan;Song, Eun Young;Son, In Chang;Oh, Soon Ja;Cho, Young Yeol
    • Journal of Bio-Environment Control
    • /
    • v.26 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • This study was conducted to investigate optimal temperature of garlic and develop bulb weight model in harvest time. Day and night temperature in chambers was set to $11/7^{\circ}C$, $14/10^{\circ}C$, $17/12^{\circ}C$, $20/15^{\circ}C$, $23/18^{\circ}C$, $28/23^{\circ}C$(16/8h). Bulb fresh and dry weight was heaviest on $20/15^{\circ}C$. In $11/7^{\circ}C$ and $14/10^{\circ}C$, leaf number and total leaf area increased slowly. But in the harvest, leaf number and total leaf area were not significant, except $28/23^{\circ}C$. Models were developed with fresh bulb weight. As a result of analyzing the model, $18{\sim}20^{\circ}C$ certified optimal mean temperature. And the growing degree day base temperature estimated $7.1^{\circ}C$, upper temperature threshold estimated $31.7^{\circ}C$. To verify the model, mean temperature on temperature gradient tunnel applied to the growth rate model. Lineal function model, quadric model, and logistic distribution model showed 79.0~95.0%, 77.2~92.3% and 85.0~95.8% accuracy, respectively. Logistic distribution model has the highest accuracy and good for explaining moderate temperature, growing degree day base temperature and upper temperature threshold.

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF

Application of SP Monitoring in the Pohang Geothermal Field (포항 지열 개발지역에서의 SP 장기 관측)

  • Lim Seong Keun;Lee Tae Jong;Song Yoonho;Song Sung-Ho;Yasukawa Kasumi;Cho Byong Wook;Song Young Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.164-173
    • /
    • 2004
  • To delineate geothermal water movement at the Pohang geothermal development site, Self-Potential (SP) survey and monitoring were carried out during pumping tests. Before drilling, background SP data have been gathered to figure out overall potential distribution of the site. The pumping test was performed in two separate periods: 24 hours in December 2003 and 72 hours in March 2004. SP monitoring started several days before the pumping tests with a 128-channel automatic recording system. The background SP survey showed a clear positive anomaly at the northern part of the boreholes, which may be interpreted as an up-flow Bone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. The first and second SP monitoring during the pumping tests performed to figure out the fluid flow in the geothermal reservoir but it was not easy to see clear variations of SP due to pumping and pumping stop. Since the area is covered by some 360 m-thick tertiary sediments with very low electrical resistivity (less than 10 ohm-m), the electrokinetic potential due to deep groundwater flow resulted in being seriously attenuated on the surface. However, when we compared the variation of SP with that of groundwater level and temperature of pumping water, we could identify some areas responsible to the pumping. Dominant SP changes are observed in the south-west part of the boreholes during both the preliminary and long-term pumping periods, where 3-D magnetotelluric survey showed low-resistivity anomaly at the depth of $600m\~1,000m$. Overall analysis suggests that there exist hydraulic connection through the southwestern part to the pumping well.

Interactive analysis tools for the wide-angle seismic data for crustal structure study (Technical Report) (지각 구조 연구에서 광각 탄성파 자료를 위한 대화식 분석 방법들)

  • Fujie, Gou;Kasahara, Junzo;Murase, Kei;Mochizuki, Kimihiro;Kaneda, Yoshiyuki
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.26-33
    • /
    • 2008
  • The analysis of wide-angle seismic reflection and refraction data plays an important role in lithospheric-scale crustal structure study. However, it is extremely difficult to develop an appropriate velocity structure model directly from the observed data, and we have to improve the structure model step by step, because the crustal structure analysis is an intrinsically non-linear problem. There are several subjective processes in wide-angle crustal structure modelling, such as phase identification and trial-and-error forward modelling. Because these subjective processes in wide-angle data analysis reduce the uniqueness and credibility of the resultant models, it is important to reduce subjectivity in the analysis procedure. From this point of view, we describe two software tools, PASTEUP and MODELING, to be used for developing crustal structure models. PASTEUP is an interactive application that facilitates the plotting of record sections, analysis of wide-angle seismic data, and picking of phases. PASTEUP is equipped with various filters and analysis functions to enhance signal-to-noise ratio and to help phase identification. MODELING is an interactive application for editing velocity models, and ray-tracing. Synthetic traveltimes computed by the MODELING application can be directly compared with the observed waveforms in the PASTEUP application. This reduces subjectivity in crustal structure modelling because traveltime picking, which is one of the most subjective process in the crustal structure analysis, is not required. MODELING can convert an editable layered structure model into two-way traveltimes which can be compared with time-sections of Multi Channel Seismic (MCS) reflection data. Direct comparison between the structure model of wide-angle data with the reflection data will give the model more credibility. In addition, both PASTEUP and MODELING are efficient tools for handling a large dataset. These software tools help us develop more plausible lithospheric-scale structure models using wide-angle seismic data.