• Title/Summary/Keyword: 선접촉

Search Result 450, Processing Time 0.028 seconds

A Technique of Measuring Leadwire-Site for Automatic Leadwire Cutting Machines (리드선 자동절단기를 위한 리드선 위치측정법)

  • ;Seiichi Noguchi;Koei Igarashi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.1
    • /
    • pp.120-130
    • /
    • 1994
  • The leadwire cutting machine that has been used recently cuts leadwires by putting one-side force with the same priciple as a saw, and applies a stress at soldered part of PCB. Because the stress becomes one cause of contact-defect, a leadwire cutting robot that cuts leadwire-site with nipper and does not apply stress is considered, In this paper a technique of detecting leadwire-site is studied for the purpose of using on automatic leadwire cutting robots. A technique deriving 2-dimensional site-information with many I-dimensional binary data of perspective front-view of PCB taken from various direction was proposed. Simulation and experiments were done under the same condition each other and a small universal PCB was choosen as an experimental object. As a result of simulations and experiments, the proposed technique turns out to be very useful for automatic leadwire cutting robots.

  • PDF

A Study on Broadband Inductive Coupler using Impregnated Nanocrystalline Ribbon (함침된 나노결정립 리본을 이용한 광대역 유도형 결합기 연구)

  • Kim, Hyun-Sik;Ju, Woo-Jin;Sohn, Kyung-Rak
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.599-605
    • /
    • 2019
  • Ferrite cores are used as a soft magnetic material in the fabrication of couplers for inductive powerline communication (PLC). However, it is difficult to adjust the size freely according to the power-line and power-grid environment. In this paper, we report that a nano-crystalline alloy with higher permeability than ferrite can be used as an inductive coupler for non-contact PLC. Since nano-crystalline are produced in the form of a thin ribbon, the size of the coupler can be freely controlled by the number of ribbons wound on the toroidal core. It was fabricated with induction type coupler and showed to be suitable for non-contact power line communication. Experimental results show that the communication bandwidth is 45 Mbps for 100 m and 8 Mbps for 200 m under the current fluctuation of less than 100 A, and the reception ratio is 100%.

Vision based Fast Hand Motion Recognition Method for an Untouchable User Interface of Smart Devices (스마트 기기의 비 접촉 사용자 인터페이스를 위한 비전 기반 고속 손동작 인식 기법)

  • Park, Jae Byung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.300-306
    • /
    • 2012
  • In this paper, we propose a vision based hand motion recognition method for an untouchable user interface of smart devices. First, an original color image is converted into a gray scaled image and its spacial resolution is reduced, taking the small memory and low computational power of smart devices into consideration. For robust recognition of hand motions through separation of horizontal and vertical motions, the horizontal principal area (HPA) and the vertical principal area (VPA) are defined respectively. From the difference images of the consecutively obtained images, the center of gravity (CoG) of the significantly changed pixels caused by hand motions is obtained, and the direction of hand motion is detected by defining the least mean squared line for the CoG in time. For verifying the feasibility of the proposed method, the experiments are carried out with a vision system.

An Evaluation of Interface Shear Strength between Geosynthetic Clay Liner and Geomembrane (토목섬유 점토 차수재(GCL)와 지오멤브레인(GM)의 접촉 전단강도 평가)

  • 서민우;김동진;박준범;박인준
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.137-146
    • /
    • 2002
  • Geomembrane, compacted clay liner, and geosynthetic clay liner (GCL) are widely used to prevent leachate from leaking to adjacent geo-environment at a municipal solid waste (MSW) landfill. Interface shear strength between GCL and geomembrane installed at a landfill side slope is important properties for the safe design of side liner or final cover systems. The interface shear strength between two geosynthetics was estimated by a large direct shear test in this study. The shear strength was evaluated by the Mohr-Coulomb failure criterion. The effects of normal stress, hydration or dry condition, and a hydration method were investigated. The test results show that the interface shear strength and shear behavior varied depending up on the level of normal stress, the type of geosynthetic combinations, and a hydration method. When GCLs were sheared after being hydrated under 6kPa loading, the results were consistent with those published by other researchers. Summaries of friction angles, normal stress and hydration condition is presented. These friction angles could be used as a reference value at a site where similar geosynthetics are installed.

The Evaluation of Interface Shear Strength Between Geomembrane and Ceotextile (지오멤브레인/지오텍스타일의 접촉 전단강도 평가)

  • 서민우;박준범;김운영
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.1
    • /
    • pp.79-89
    • /
    • 2002
  • Various geosynthetics used as liners or protection layers are installed in the solid waste landfills. The interface shear strength between geosynthetics installed at the slope of the landfill is a very important variable for the safe design of the bottom and cover systems in the solid waste landfills. The interface shear strength between Geomembrane and Geotexile is estimated by a large direct shear test in this study, The effects of normal stress, water existing between geosynthetics and surface condition of Geomembrae, i.e. smooth or textured, were investigated. The test results show that the effect varied depending on the level of normal stress and the type of geosynthetic combinations. The shear strength was evaluated by the Mohr-Coulomb failure criterion in this research. The shear strength parameters obtained from tests considering the site specific conditions such as normal stress, dry or wet, and surface condition of geosynthetic should be applied to the design of geosynthetics installed at the slope of the landfill to construct a safe solid waste landfill.

Analysis of Hot Judder of Disc Brakes for Automotives by Using Finite Element Method (유한 요소법을 이용한 자동차용 디스크 브레이크의 열간 저더 해석)

  • Jung, Sung-Pil;Park, Tae-Won;Chung, Won-Sun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.4
    • /
    • pp.425-431
    • /
    • 2011
  • Thermal energy generated because of the friction between the disc and pad is transferred to both sides and causes thermal expansion of the material, which affects the contact pressure distribution. This phenomenon, which is called thermoelastic instability (TEI), is affected by the natural mode of a disc. TEI results in the formation of a hot spot and causes hot judder vibrations. In this study, three-dimensional analysis of the hot judder of a ventilated disc for automotives was performed by using the commercial finite element analysis program, SAMCEF. The intermediate processor based on a staggered approach was used to exchange the result data of the mechanical and thermal model. The hot spot was formed on the surface of the disc, and the number of hot spots was compared with the natural mode of the disc.

Analysis of the Current-Collection Performance of a High-Speed Train Using Finite Element Analysis Method (유한 요소 해석 기법을 이용한 고속 철도 차량의 집전 성능 해석)

  • Jung, Sung-Pil;Park, Tae-Won;Kim, Young-Guk;Park, Chan-Kyoung;Paik, Jin-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.827-833
    • /
    • 2011
  • In this study, a simulation model to estimate the current-collection performance of a high-speed train was developed by using a commercial finite element analysis software, SAMCEF. A three-dimensional springDdamperDmass model of a pantograph was created, and its reliability was validated by comparing the receptance of the model to that of the actual pantograph. The wave propagation speed of the catenary model was compared with the analytical wave propagation speed of the catenary system presented in the UIC 799 OR standard. The length of the droppers was controlled, and the pre-sag of the contact wire due to gravity was considered. The catenary and the pantograph were connected by using a contact element, and the contact force variation when the pantograph was moved at velocities of 300 km/h and 370 km/h was obtained. The average, standard deviation, maximum, and minimum values of the contact force were analyzed, and the effectiveness of the developed simulation model was examined.

Study on EMI Elimination and PLN Application in ELF Band for Romote Sensing with Electric Potentiometer (전위계차 센서를 이용한 원격센싱을 위한 ELF 대역 EMI 제거 및 PLN 응용 연구)

  • Jang, Jin Soo;Kim, Young Chul
    • Smart Media Journal
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 2015
  • In this paper, we propose the methods not only to eliminate ELF(Extremely Low Frequency) EMI(Electro-Magnetic Interference) noice for extending recognition distance, but also to utilize the the PLN for detecting starting instance of a hand gesture using electric potential sensor. First, we measure strength of electric field generated in the smart devices such as TV and phone, and minimize EMI through efficient arrangement of the sensors. Meanwhile, we utilize the 60 Hz PLN to extract the starting point of hand gesture. Thereafter, we eliminate the PLN generated in the smart device and circuit of sensors. And then, we shield the sensors from an electric noise generated from devices. Finally, through analyzing the frequency components according to the gesture of target, we use the low pass filter and the Kalman filter for elimination of remaining electric noise. We analyze and evaluate the proposed ELF-band EMI eliminating method for non-contact remote sensing of the EPS(Electric Potential Sensor). Combined with a detecting technique of gesture starting point, the recognition distance for gestures has been proven to be extended to more than 3m, which is critical for real application.

Effect of the particle size on the electrical contact in selective electro-deposition of copper (구리의 선택적 전착에서 결정 입자의 크기가 전기적 접촉성에 미치는 영향)

  • Hwang, Kyu-Ho;Lee, Kyung-Il;Joo, Seung-Ki;Kang, Tak
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.1 no.2
    • /
    • pp.79-93
    • /
    • 1991
  • With the advent of ULSI, many problems in previous metallization techniques and interconnection materials have become more serious. In this work, selective deposition of copper to fill the submicron contact has been tried. After forming electro-deposited copper films on p-type (100) silicon wafer using 0.75M $CuSO_4{\cdot}$5H_2O$ as an electrolyte, the effect of deposition time, current density and concentration of an additive on film properties were investigated. Film thickness, particle size and resistivity were analyzed by Alpha Step, SEM and 4 - point probe measurement respectively. The deposition rate was about $0.5-0.6\mu\textrm{m}$/min at $2A/dm^2$ and the particle size increased with increasing current density. The resistivities of electro-deposited copper films were about $3-6{\mu}{\Omega}{\cdot}$cm for the particle size above $4000{\AA}$. By the addition of 0.2 g/l gelatin, the particle size was reduced to less than $0.1{\mu}m $ and selective plugging of copper on submicron contacts could be successfully achieved.

  • PDF

Retrieval of Soil Moisture Using Microwave Reflection at the End of a Coaxial Probe (동축선 끝단에서의 마이크로파 반사를 이용한 토양 수분 함유량 산출 기술)

  • 김태진;오이석
    • Korean Journal of Remote Sensing
    • /
    • v.13 no.2
    • /
    • pp.151-163
    • /
    • 1997
  • In this paper, an algorithm for retrieving soil moisture from measurement of microwave reflection at the end of a coaxial canble is presented. Because the wave reflection from the boundary between air and soil layers depends on the dielectric constant of the soil layer, the dielectric constant can be obtained from measured reflection coefficient. At first, an equivalent circuit for the coaxial probe contaced on the soil surface was chosen with two unknown circuit elements. Then, the unknown circuit elements are obtained experrmentally by measuring the reflection constants of 20 soil samples, and consequently, an empirical formula for computing the dielectric constant from the reflection coefficient is obtained. The dielectric constant is mainly influenced by the soil moisture, and the soil moisture can be computed from the dielecfic constant using an existing empirical formula. HP Network Analyzer 8510C was used to measure the magnitude and the phase of the reflection coeffcient at 4.65 GHz, and the measured data set were used to obtain an empirical formula for computing the dielectric constant. The empirical formula obtained in this study was proven by other soil samples.