• Title/Summary/Keyword: 선원 위치 검출기

Search Result 43, Processing Time 0.031 seconds

Design of a Radiation Spectroscopy Detector using a Spherical Scintillator and Development of a Radiation Source Position Tracking System (구형의 섬광체를 이용한 방사선 스펙트로스코피 검출기 설계 및 방사선원 위치 추적 시스템 개발)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.725-731
    • /
    • 2020
  • A radiation spectroscopy detector using a spherical scintillator was designed, and a system was developed to track the position of a radiation source using several detectors. The position tracking algorithm was designed based on the theory that the number of radiations decreases according to the inverse square law of distance, and the position of the radiation source was calculated by measuring the number of radiations generated from the radiation sources at various positions. The radiation generated from the radiation source is detected by different coefficients in each detector, and the difference between these detected coefficients varies in proportion to the inverse square of the distance. Geant4 Application for Tomographic Emission (GATE) simulation was performed to verify and evaluate the performance of the designed radiation source position tracking system, and radiation generated from radiation sources placed at different positions was counted with each detector. The number of measured radiations was tracked through the radiation source position tracking algorithm, and the error between the actual radiation source position and the position calculated by the algorithm was evaluated. The error between the position of the actual radiation source and the calculated position was measured as an average of 0.11% on the X-axis and 0.37% on the Y-axis, and it was verified that the position can be measured very accurately.

The Study on Design of lead monoxide based radiation detector for Checking the Position of a Radioactive Source in an NDT (비파괴검사 분야에서 방사선원의 위치 확인을 위한 산화납 기반 방사선 검출기 설계에 관한 연구)

  • Ahn, Ki-Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.183-188
    • /
    • 2017
  • In recent years, the automatic remote control controller of the gamma ray irradiator malfunctions, and radiation workers are continuously exposed to radiation exposure accidents. In the non-destructive testing field, much time and resources are invested in establishing a radioactive source monitoring system in order to prevent potential incidents of radiation. In this study, the gamma-ray response properties of the lead monoxide-based radiation detector were estimated through monte carlo simulation as a previous study for the development of a radioactive source location monitoring system that can be applied universally to various non-destructive testing equipment. As a result of the study, the optimized thickness of the radiation detector varies according to the gamma-ray energy emitted from the radioactive source, and the optimized thickness gradually increases with increasing energy. In conclusion, the optimized thickness of the lead monoxide-based radiation detector was $200{\mu}m$ for the Ir-192, $150{\mu}m$ for the Se-75 and $300{\mu}m$ for the Co-60. Based on these results, the appropriate thickness of lead monoxide-based radiation detector considering secondary-electron equilibrium was evaluated to be $300{\mu}m$ for general application. These results can be used as a basic data for determining the appropriate thickness required in the radiation detector when developing a radiation source location monitoring system for universal application to various non-destructive testing equipment in the future.

The Study on Design of Semiconductor Detector for Checking the Position of a Radioactive Source in an NDT (비파괴검사 분야에서 방사선원의 위치 확인을 위한 반도체 검출기 설계에 관한 연구)

  • Kim, Kyo-Tae;Kim, Joo-Hee;Han, Moo-Jae;Heo, Ye-Ji;Ahn, Ki-Jung;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.171-175
    • /
    • 2017
  • In the non-destructive inspection field, we invest a lot of time and resources in developing the radiation source system to ensure the safety of the workers. However, the probability of accidents is still high. In order to prevent potential radiation accidents in advance, it is necessary to directly verify the position of the radiation source, but the research is still insufficient. In this study, we developed a monitoring system that can detect the position of the radiation source in the source guide tube in the gamma-ray irradiator. The characteristics of the radiation detector are estimated by monte carlo simulation. As a result, the radiation detector for Ir-192 gamma-ray energy was analyzed to have secondary electron equilibrium at $150{\mu}m$ regardless of the semiconductor material. Also, it is expected that the gamma ray response characteristic is the best in $HgI_2$. These results are expected to be used as a basis for determining the optimal thickness of the radiation detector located in the detection part of the future monitoring system. In addition, when developing a monitoring system based on this, radiation workers can easily recognize the danger and secure safety, as well as prevent and preemptively respond to potential radiation accidents.

Development of 3D Radiation Position Identification System of Multiple Radiation Sources using Plastic Scintillator and NaI(TI) Detector (플라스틱 Scintillator와 NaI(TI) 검출기를 이용한 다수의 방사선원 위치를 3차원으로 판별하는 측정시스템 개발)

  • Kwak, Dong-Hoon;Ko, Tae-Young;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.638-644
    • /
    • 2018
  • In this paper, we develop a measurement system that uses 3D Scintillator and NaI(TI) Detector to 3-dimensionally identify the location of multiple radiation sources in moving vehicle loads. The radiation measurement system consists of radiation measurement (plastic scintillator), 2-channel Pulse Counter Board, nuclide analysis (NaI(TI) detector) and 1 channel MCA Board. The source locator algorithm calculates the coordinate value of the ratio of the CPS value($1/r^2$) of the source according to the angle(${\theta}$) in inverse proportion to the square of the distance(X, Y) through the SVM classification. The coordinate values are input every predetermined period of the spectrum, and after analyzing the spectrum per unit cycle, the position of the nuclide at the time is calculated by determining whether or not the nuclide is present in the remaining part except for the background area. As a result of the position discrimination test, the error within the international standard of ${\pm}1m$ was shown. Thus, the utility of the proposed system has been demonstrated.

A Study of Uniformity Test in PET/CT (PET/CT 장치의 uniformitly측정에 관한 연구)

  • Kim, Su-Keun;Jung, Hee-Il;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • The PET scanner can detect the photon pair arriving from the source in phantom. The number of light photons released by the crystal(scintillator-BGO or LSO). In recent scintillation crystals in block structures were incorporated into full ring systems, and their resulted marked improvement in spatial resolution and increase in a sensitivity to annihilations. The uniformity of the crystal sensitivity is very important to makes correct information of abnormal states in organs. These factors influenced by the dection efficiency of the scintillators. We have study about the uniformity of crystals to the annihilation, And study about the standard deviation to average counts. The relative standard deviation in central detector groups more uniformed than circumferenced detector groups. It is caused detected quanta of gamma ray by the geometrical factors of PET detector. PET cameras are available with different geometric arrangement and several parallel rings oriented in the axial direction. The center groups from 7th to 40th groups are comparatively uniform and sensitive. But at the circumferenced detectors decreased the sensitivity and uniformity.

  • PDF

Evaluation of Angle Dependence on Positional Radioisotope Source Detector using Monte Carlo Simulation in NDT (몬테카를로 시뮬레이션을 이용한 방사선원 위치 검출기의 각도의존성 연구)

  • Han, Moojae;Heo, Seunguk;Shin, Yohan;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.141-146
    • /
    • 2019
  • Radiation sources used in the field of industrial non-destructive pose a risk of exposure due to ageing equipment and operator carelessness. Thus, the need for a safety management system to trace the location of the source is being added. In this study, Monte Carlo Simulation was performed to analyse the angle dependence of the unit-cell comprising the line-array dosimeter for tracking the location of radiation sources. As a result, the margin of error for the top 10% of each slope was 5.90% at $0^{\circ}$, 8.08% at $30^{\circ}$, and 20.90% at $60^{\circ}$. The ratio of the total absorbed dose was 83.77% at $30^{\circ}$ and 53.36% at $60^{\circ}$ based on $0^{\circ}$(100%) and showed a tendency to decrease with increasing slope. For all gradients, the maximum number was shown at $30^{\circ}$ No. 9 pixels, and for No. 10, there was a tendency to drop 7.24 percent. This study has shown a large amount of angle dependence, and it is estimated that the proper distance between the source and line-array dosimeters should be maintained at a distance of not less than 1 cm to reduce them.

MCNP코드를 이용한 수분 측정계기의 기하학적 배치

  • 최원철;이석근;황주호;전홍배;양세학;권정광
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.139-146
    • /
    • 1996
  • 도로건설시 다짐조절은 안정성과 내구성 향상에 중요한 의미를 가지며 이러한 다짐조절에 있어서 수분함량의 측정은 매우 중요하다. 이전에는 흙의 수분함량을 측정하기 위한 계기를 설계하기 위하여 주로 실험에 의한 방법을 사용하였으나 본 연구에서는 3차원 모델링이 가능한 MCNP코드$^{(1)}$ 를 이용하여 계측기 설계에 있어서 중요한 설계변수인 방사선원의 위치와 측정계기 사이의 거리 그리고 계기구성요소인 검출기의 위치, 개수, 흡수재, 감속재의 기하학적 구조 등을 계산하여 설정하였다.

  • PDF

Development of Multiwire Proportional Counter for Measurement of Environmental-level Alpha Particles (환경준위 알파입자측정을 위한 다중선 비례계수기 개발(I))

  • Oh, Pil Jae;Park, Tae Soon;Lee, Min Kie;Kim, Kyung Hwa
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.262-269
    • /
    • 1996
  • The muiltiwire proportional counter for the measurement of low-level and environmental $\alpha$ particles emitting nuclides was developed. External dimension of the devloped multiwire proportional counter is $350{\times}290{\times}30mm$ and the sensitivity area is $250{\times}200mm$. The wall material of the detector was selected the stainless steel to prevent the deformation by external impact and to obtain minimum background. The anode and cathode wires were used the stainless steel material of diameter $50{\mu}m$. The spacing of each wires are 10.0mm, 5.0mm and the numbers of total wire are 21, 42 lines, respectively. The multiwire proportional counter was designed that the measurement source is placed within the detector to prevent the wall absorption effect and the efficiency variation by various source heights. The characteristics of the developed detector have been investigated to obtain the plateau, operating voltage, background, counting efficiency, position sensitivity and energy resolution etc. For the $^{241}Am$ nuclide, the calculated LLD(Lower Limit of Detection) is 5.0mBq/L which is lower than 40mBq/L of recommended LLD value by ISO(International Organization for Standardization).

  • PDF

A Design on neutron absorber and moderator for the content measurement of Asphalt (아스팔트 함량 측정을 위한 중성자 흡수체 및 감속재 설계)

  • Kim Ki-Joon
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.1
    • /
    • pp.7-14
    • /
    • 2006
  • In Korea, under the influence of the jurisdiction, usage of radioisotopes are limited. The limitation is $100[{\mu}Ci]$ or less. Therefore, in this study, basic data were designed, and the following data are needed in order to improve content measuring instrument which is suitable for radioisotopes limitation. Owing to the source and detector's properties, measuring instrument was designed geometrically, neutron and photon's particle transportation was analysed by using the MCNP code which is in Monte Carlo Method, also the location of source and detectors, geometrical structure of neutron absorber and moderator was designed.

  • PDF

Steel Plate Thickness Gauge by means of Gamma-Ray Backscattering (감마선 빽스켓터링을 이용한 철판 두께 측정에 관하여)

  • 김덕진;김동훈
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.1
    • /
    • pp.18-23
    • /
    • 1966
  • An experimental study of a steel plate thickness gauge by means of the measurements of backscatered gamma-rays has been carried out. The difference between this and other methods is that this method does not include any shilding matterials in the detecting probe, because the primary radiations and the backscattered radiations are detected simultaneously by an NaI (TI) scintillating crystal, and the activity of the Co-60 source used is low enough. In this thickness gauge, the thickness of the steel plates can be read directly on the counting ratemeter scale. The optimum conditions in the source-to-detector distance, window width of the analyzer, energy and strength of the gamma-ray source were found experimentally. The results have shown that the accuracy of the gauge was about $\pm$3% in the range of 3 to 8mm thickness. This gauge can be used to detect the pits or corrosions on the inner walls of the steel pipes.

  • PDF