• Title/Summary/Keyword: 선로이용율

Search Result 74, Processing Time 0.02 seconds

Patrol Monitoring Plan for Transmission Towers with a Commercial Drone and its Field Tests (상용화 드론을 이용한 송전선로 점검방안 및 현장시험)

  • Kim, Seok-Tae;Park, Joon-Young;Lee, Jae-Kyung;Ham, Ji-Wan;Choi, Min-Hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.115-123
    • /
    • 2018
  • Various types of robots running on power transmission lines have been developed for the purpose of line patrol monitoring. They usually have complex mechanism to run and avoid obstacles on the power line, but nevertheless did not show satisfactory performance for going over the obstacles. Moreover, they were so heavy that they could not be easily installed on the lines. To compensate these problems, flying robots have been developed and recently, multi-copter drones with flight stability have been used in the electric power industry. The drones could be remotely controlled by human operators to monitor power distribution lines. In the case of transmission line patrol, however, transmission towers are huge and their spans are very long, and thus, it is very difficult for the pilot to control the patrol drones with the naked eye from a long distance away. This means that the risk of a drone crash onto electric power facilities always resides. In addition, there exists another danger of electromagnetic interference with the drones on autopilot waypoint tracking under ultra-high voltage environments. This paper presents a patrol monitoring plan of autopilot drones for power transmission lines and its field tests. First, the magnetic field effect on an autopilot patrol drone is investigated. Then, how to build the flight path to avoid the magnetic interference is proposed and our autopilot drone system is introduced. Finally, the effectiveness of the proposed patrol plan is confirmed through its field test results in the 154 kV, 345 kV and 765 kV transmission lines in Chungcheongnam-do.

Multi-layer restoration strategy to restore the multi-link and node failures in DCS mesh networks (DCS mesh 네트워크에서 다중 선로 장애와 노드 장애를 복구하기 위한 다중 계층 복구 전략)

  • 김호진;조규섭;이원문
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.12
    • /
    • pp.2744-2754
    • /
    • 1997
  • Recently, the Multi-Layer Restoration(MLR) algorithm was proposed by British Telecom(BT) to restore the network failures in Digital Cross-connect System(DCS) mesh survival network[1, 2]. This algorithm has multi restoration stage which is composed of the pre-planned and dynamic restoration. This algorithm is effective its ability in link or node failures. This reason is that it does not restore in the pre-planned rstoration stage but in dynamic restoration stage. In this paper, we propose the MLR with pre-planned Multi-Chooser(PMC) and successive restoration ratio algorithm. This proposed algorithm has a excellent performance for restortion time and ratio, spare channel availability and fast restoration from multiple link failure or node failure. This paper proposed the modeling and restoration algorithm, and analyzed the performance of the algorithm by simulation using OPNET(OPtimized Network Engineering Tools).

  • PDF

Design and Implementation of Triple-band WLAN Antenna with Microstrip Lines (마이크로스트립 선로를 이용한 삼중대역 WLAN 안테나의 설계 및 제작)

  • Yoon, Joong-Han
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.33-40
    • /
    • 2019
  • In this paper, a microstrip-fed triple-band antenna for WLAN system with microstrip lines was designed, fabricated and measured. The proposed antenna is composed of two strip lines and slit in the ground plane and then designed in order to get triple band characteristics. We carried out simulation on $L_3$, $L_{10}$, and slit parameters, and adjusted the parameters of the proposed antenna to satisfy the required frequency band and bandwidth. The proposed antenna is made of $32.0{\times}44.0{\times}1.0mm$ and is fabricated on the permittivity 4.4 FR-4 substrate. The experiment results shows that the proposed antenna obtained the -10 dB impedance bandwidth 120 MHz (890 MHz~1.01 MHz), 440 MHz (2.35~2.79 GHz), and 1,280 MHz (5.07~6.35 GHz) covering the triple WLAN bands. Also, the measured gain and radiation patterns characteristics of the proposed antenna are presented at required frequency band, respectively.

A Study on the Algorithms for Calculating Internet Analysis Parameters using SNMP MIB-II (SNMP MIB-II를 이용한 인터네트 분석 파라미터계산 알고리즘에 관한 연구)

  • Ahn, Seong-Jin;Chung, Jin-Wook
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.8
    • /
    • pp.2102-2116
    • /
    • 1998
  • 본 논문에서는 TCP/IP 프로토콜을 기반으로 하는 인터넷에서 SNMP의 MIB-II를 활용하여 분석 파라미터를 정의하고 이를 계산하는 알고리즘을 제안하고자 한다. TCP/IP 망의 사용자에게 적절한 QoS를 제공하기 위해서는 성능과 장애에 관련된 파리미터를 기반으로 한 망 관리 행위를 수행해야 한다. 이를 위해서 인터넷 관리 표준을 정의된 MIB-II의 관리 정보를 기반으로 분석 파라미터를 정의하고 이를 계산하기 위한 알고리즘을 제시하고자 한다. MIB-II에서 system, interface, ip, snmp 그룹의 관리 변수를 Case 다이어그램에 따라 분석하여 선로 이용률, 에러 수신율, 인터페이스 패킷 송수신율, 인터페이스 패킷 송수신 손실률, 입출력 트래픽률, 방송형 송수신 트래픽 비율, 시스템 패킷 입출력률, 시스템 패킷 송수신 손실률, 시스템 자원 부하율, 패킷 전달률, 경로 설정 실패율, 관리 트래픽 이용률 등의 분석 파라미터와 계산 알고리즘을 제안한다. 분석 파라미터 계산 알고리즘에 대한 적용성을 실험하기 위해서 실존하는 라우터를 대상으로 분석 결과를 제시하고 진단하였다. 이러한 인터넷 분석 파라미터 계산 알고리즘은 망 관리자가 전체 TCP/IP 통신 네트워크를 진단하고 분석할 수 있는 자료로 활용될 수 있을 뿐만 아니라 인터넷 사용자에게 QoS를 제공하루 수 있을 것으로 기대된다.

  • PDF

Stepped Impedance LPF using MCSl (MCS선로를 이용한 스텝 임피던스 저역필터)

  • Rhee, Seungyeop;Lee, Seongjae;Kim, On
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.3
    • /
    • pp.153-157
    • /
    • 2008
  • The MCS(Micro-coplanar strip) line has been analyzed. The conformal mapping method is used to calculate the quasi-static effective permittivity and characteristic impedance of this MCS line. The computed results of the present work are found to be in good agreement when compared with the results obtained using commercial S/W, IE3D. And in this paper, the stepped-impedance low pass microstrip filter is designed and fabricated with MCS lines for improving the frequency responses. The LPF proposed structure has been also designed and implemented to have the sharp attenuation characteristics in stop band. The agreement between simulation and measurement results verify the implemented LPF.

  • PDF

A Study on RF Characteristics of Transmission Line Employing Inverted Periodically Arrayed Capacitive Devices for Application to Highly Miniaturized Wireless Communication system on MMIC (MMIC 상에서 초소형 무선 통신 시스템에의 응용을 위한 반전된 형태의 주기적 용량성 구조를 이용한 전송선로의 RF 특성에 관한 연구)

  • Kim, Jeong-Hoon;Jang, Jang-Hyeon;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.52-57
    • /
    • 2015
  • In this paper, we studies on the RF characteristics of the transmission line employing IPACD (inverted periodically arrayed capacitive devices) on MMIC (monolithic microwave integrated circuit) for application to wireless communication system. According to measured results, the novel transmission line employing IPACD showed a wavelength much shorter than conventional transmission lines. In addition, the IPACD structure showed an effective permittivity much higher than conventional ones. We also extracted the bandwidth characteristic of the IPACD structure using equivalent circuit analysis. According to the results, the cut-off frequency of the proposed structure was 129.2 GHz.

Design and Implementation of a Linearizer Using the Feedforward Loop without Delay Lines (지연 선로가 없는 Feedforward Loop를 이용한 선형화기의 설계 및 제작)

  • 정승환;조경준;김완종;안창엽;김종헌
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.116-123
    • /
    • 2000
  • This paper presents a linearizer using the feedforward loop which can be applied to PCS base-station applications. This linearizer used a IM amplifier and an auxiliary amplifier in order to remove delay lines used in the predistortor using the feedforward technique. The delay line in error loop is changed by the main power amplifier(PA) and the error amplifier is utilized to amplify the error signal which fed to the output of main amplifier. The linearizer was simulated by HP ADS ver 1.1 and fabricated on GML 1000 with thickness of 0.8 mm and dielectric constant of 3.2. Two-tone signals at 1.85 GHz and 1.851 GHz with -7dBm/tone from synthesizers are injected into the main PA. The main PA with a 27 dB gain and a $P_{1dB}$ of 29 dBm(two-tone) was utilized. The reduction of intermodulation distortion (IMD) is around 17 dB.

  • PDF

A Design of Novel Compact Microstrip Bandstop Filters Based on Split-Ring Resonators and Spiral Resonators (Split-Ring 공진기와 Spiral 공진기를 이용한 새로운 소형의 마이크로스트립 대역 저지 필터 설계)

  • Lee, Jong-Hyuk;Oh, Young-Chul;Myung, Noh-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.796-808
    • /
    • 2007
  • In this paper, two novel compact microstrip bandstop filters using complimentary split ring resonators(CSRRs) and spiral resonators is proposed. The first one is the bandstop filter using an array of CSRRs etched on the center line of a microstrip. The bandstop is due to the presence of negative effective permittivity and positive permeability near resonant frequency which prevent the wave propagation. The second on is the bandstop filter using an array of spiral resonators etched on the center line of a microstrip. The bandstop is due to the self-resonance of spiral circuit. We have achieved controllable resonance frequency and bandwidth, super compact dimension, low insertion losses in the passband and high level of rejection in the stopband with sharp cutoff. The electrical sizes of two proposed filter are very small. Additionally, they can be easily fabricated and compatible with MMIC or PCB technology.

Study on RF characteristics of voltage-controlled artificial transmission line employing periodically arrayed diodes for application to highly miniaturized wireless communication systems (초소형 무선 통신 시스템에서의 응용을 위한 주기적으로 배열된 다이오드를 이용한 전압제어형 전송선로의 RF 특성에 관한 연구)

  • Kim, Soo-Jeong;Kim, Jeong-Hoon;Jeong, Jang-Hyeon;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.70-75
    • /
    • 2017
  • In this paper, we studied the RF characteristics of a voltage-controlled artificial transmission line employing periodically arrayed diodes for application to highly miniaturized wireless communication systems on an MMIC (monolithic microwave integrated circuit). According to the results, the novel voltage-controlled artificial transmission line employing periodically arrayed diodes exhibited a short wave length, which was only 35.2% that of the conventional transmission line, owing to increasing capacitance. In addition, it's effective permittivity and effective propagation constant exhibited considerably higher values than those of the conventional transmission line. Furthermore, attenuation constant of the voltage-controlled artificial transmission line was far higher than that of the conventional transmission line. Using the closed-form equation, we theoretically analyzed the equivalent circuit of the voltage-controlled artificial transmission line.

UWB Bandpass Filter Using Capacitive Coupling with Cross Resonator ("+"자 공진기와 용량성 결합을 이용한 초광대역 대역 통과 여파기)

  • Dong, Thai Hoa;Lee, Jae-Young;Kim, Ihn-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.5
    • /
    • pp.486-493
    • /
    • 2010
  • This article introduces a novel ultra wideband(UWB) bandpass filter(BPF) with sharp roll-off characteristics in stripline structure. The UWB characteristic is basically obtained from capacitive coupled cross resonator. The resonator has ${\lambda}/2$ length. And at the center of the resonator, two stubs are loaded, one is a ${\lambda}/8$ short-circuited stub and the other is a ${\lambda}/8$ open-circuited stub. The two stubs provide two attenuation poles at lower and upper cutoff frequencies. For input and output lines, two identical capacitively coupled lines have been installed to suppress the unwanted signals in the lower and upper stopbands. The filter has been designed for the U.S. UWB band(3.1~10.6 GHz) with two transmission zeros at 2.4 and 11.1 GHz. The filter has been realized with Low Temperature Core-fired Ceramic(LTCC) green tape which has the dielectric constant of 7.8. Measurement results agree well with HFSS simulation results. Insertion loss less than 0.7 dB and return loss better than 14 dB in the pass band have been measured. The group delay in the center frequency is 0.27 ns and the group delay variation within pass band is less than 0.5 ns. The size of the filter is $6{\times}18{\times}0.6\;mm^3$.