• Title/Summary/Keyword: 선량-반응

Search Result 349, Processing Time 0.029 seconds

A Study On Low Radiation Measurement of Radiation Measuring Devices and Improvement of Reaction Speed according to the Rapid Change of Radiation Dose (방사선 측정장치의 저준위 방사선 측정과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선에 관한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.544-551
    • /
    • 2014
  • This paper suggests an algorithm to measure low-level radiation by radiation measuring devices, and the other algorithm to improve reaction speed of the device to better respond to dramatic changes in radiation amount. The former algorithm to improve the accuracy of measuring low-level radiation takes advantage of a dual window radiation measurement method which is based on accumulated average of pulses gathered by a radiation measuring sensor. The latter algorithm is to enhance reaction speed of a measuring device to more sensitively react to dramatic changes in radiation amount by adopting a dual window radiation measurement method which analyzes data patterns newly put into for six seconds. To verify the suggested algorithms, a hardware-which consists of sensor and high-voltage generator, controller, charger and power supply circuit, wireless communication part, and display part-was used. Tests conducted on the dual window radiation measurement method as used in the suggested algorithm have proved that accuracy improves to measure low-level radiation of 5uSv/h, and linearity also gets better. Other tests were conducted to see whether the suggested algorithm enhances the reaction speed of a radiation measuring device so that the device responds better to dramatically changing radiation amount. The experimental results have shown meaningful changes in numbers after six seconds. Therefore, the conclusions are made that the algorithm enhances the reaction speed of the device.

A Study of Performance Characteristics for Electronic Personal Dosimeters in Photon and Electron Radiation Field (광자 및 베타 방사선에 대한 전자개인선량계의 성능특성연구)

  • Kim, Hyun-Ki;Kim, Bong-Hwan;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.85-95
    • /
    • 1997
  • TLD and film badges have been traditionally used as formal dosimeters in personal monitoring and are still most widely used. Recently, electronic personal dosimeters based upon Si diode or miniature G-M tube were developed and are getting attractions due to their merits of active nature ; indication of dose rates and the commutative dose, and facilitation of record keeping and radiological control. Response characteristics of the electronic dosimeters including reproducibility, accuracy, linearity, energy and angular dependencies, detection threshold, and response time were examined for three commercial types ; EPD2, STEPHEN6000, and PD-3i. The results were compared with the relevant requirements of IEC standards and Ontario Hydro standards to conclude that their general performances were good. Some specific deficiencies, e.g. incapability of shallow dose measurement of STEPHEN6000, and PD-3i, however, should be corrected to be used as a formal dosimeter.

  • PDF

A Feasibility Study on the Lens of Eye Dose Assessment Using the System of Multi-Element TLD (다중소자 열형광선량계에 의한 수정체 등가선량 평가의 적정성 연구)

  • Lee, Na-Rae;Han, Seung-Jae;Lee, Byung-Il;Cho, Kun-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.96-102
    • /
    • 2012
  • International Commission on Radiological Protection (ICRP) has revised its recommendations concerning the tissue reaction to ionizing radiation in accordance with consideration of the detriment arising from non-cancer effects of radiation on health based on recent epidemiological basis. Particularly, for the lens of the eye, the threshold in absorbed dose revised to be 0.5 Gy, for occupational exposure in planned exposure situation the commission recommended "An equivalent dose limit for the lens of the eye of 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv." To monitor the radiation exposure of radiation worker, TLD is typically provided and the lens of eye dose can be assessed by run of dose calculation algorithm with TL element response data. This study is to assess equivalent dose of the lens of eye using the Harshaw TLD system and its two different dose calculation algorithms. The result provides the Harshaw TLD system showed the assessment of the lens of eye dose with 48.84% error range.

Intraluminal High-Dose-Rate Brachytherapy for the Tumors of Gastrointestinal Tract (위장관 종양의 고선량율 강내 방사선치료)

  • Choi Byung Ock;Choi Ihl Bhong;Chung Su Mi;Kim In Ah;Choi Myoung Gyu;Chang Suk Kyun;Shinn Kyeong Sub
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.243-252
    • /
    • 1995
  • Purpose : Intraluminal high dose rate brachytherapy is an accepted treatment for the tumors of GI tract. However, there is only some limited clinical data for intraluminal high dose rate brachytherapy for the tumors of GI tract. Materials and Methods : Between February 1991 and July 1993, 18 Patients who have the tumors of GI tract (esophageal cancer-8 cases, rectal cancer-10 cases) were treated with high dose rate Iridium-192 afterloading system (Microselectron-HDR, Nucletron CO, Netherland) at the department of therapeutic radiology, St. Mary's hospital, Catholic university medical college. Age range was 47-87 years with a mean a9e 71 years. All patients were treated with intraluminal high dose rate brachytherapy within two weeks after conventional external radiation therapy and received 3-5 Gy/fraction 3-4 times per week to a total dose 12-20 Gy (mean 17 Gy). Standard fractionation and conventional dose were delivered for external radiation therapy. Total dose of external radiation therapy ranged 41.4-59.4 Gy (mean 49.6 Gy). Median follow up was 19 months Results : The analysis was based on 18 patients, The complete response and partial response in esophageal cancer was similar (38%). Two year rates for survival and median survival were 13% and 10 months, respectively. Among 10 patients of rectal cancers, partial response was obtained in 6 patients (60%). There was no complete response in the patients with rectal cancer, but good palliative results were achieved in all patients. Conclusion : Although the number of patients was not large and the follow-up period was relatively short, these findings suggested that intraluminal high dose rate brachytherapy could be useful in the treatment of the patients with advanced tumors of GI tract.

  • PDF

Development of Electronic Personal Dosimeter with Hybrid Preamplifier using Semiconductor Detector (반도체 검출기를 이용한 Hybrid 전치증폭기형 전자식 개인선량계 개발)

  • Lee, B.J.;Kim, B.H.;Chang, S.Y.;Kim, J.S.;Rho, S.R.
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.51-57
    • /
    • 2002
  • An electronic personal dosimeter(EPD) with hybrid type preamplifier adopting a semiconductor detector as a radiation detector has been developed, manufactured and test-evaluated. The radiation detection characteristics of this EPD has been performance-tested by using a reference photon radiation field. After several test-irradiations to a $^{137}Cs$ gamma radiation source the radiation detection sensitivity of this EPD appeared to be $3.8\;cps/Gy{\cdot}h^{-1}$. The linearity of radiation response was kept within 8% of the dose equivalent ranges of $10{\mu}Sv{\sim}4Sv$ and the angular dependence was under less than 4% in angles of ${\pm}60^{\circ}$. It was confirmed that the energy response range was in $60{\sim}1,250keV$ given in the ISO standard. This EPD satisfied the international criteria for the EPD in the mechanical and the environmental performance test for 9 test categories according to IEC 61526.

Development of Prototype Electronic Dosimeter using the Silicon PIN Diode Detector (실리콘 PIN 다이오드 검출기를 이용한 전자선량계 개발)

  • Lee, B.J.;Kim, B.H.;Chang, S.Y.;Kim, J.S.
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.197-205
    • /
    • 2000
  • A prototype electronic dosimeter(PED) adopting a silicon PIN diode detector as a radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this PED has been performance-tested by using a reference photon radiation field. As a result in a electronic performance test, radiation signals from a detector were well observed in the signal processing circuit. The radiation detection sensitivity of this PED after several test-irradiations to $^{137}Cs$ gamma radiation source appeared to be 1.85 cps/$Gy{\cdot}h^{-1}$ with 19.3% of the coefficient of variation, which satisfied the performance criteria for the active personnel radiation monitor. Further improvement of the electronic circuit and operating program will enable the PED to be used in personal monitoring purpose.

  • PDF

The Measurement and Evaluation of X-ray Characteristics of Cadmium Sulfide as a Multi-function Dosimeter (다기능 선량계로서의 Cadmium sulfide의 X-선에 대한 특성 평가)

  • Park, Sung-Kwang;Park, Young-Min;Cho, Heung-Lae;Nam, Sang-Hee
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.161-166
    • /
    • 2003
  • To evaluate the performance of cadmium sulfide as a multi-function X-ray dosimeter, we made an X-ray detector that was based on cadmium sulfide using evaporation technology, and measured its response to X-ray exposure. The voltages of cadmium sulfide were measured on the various X-ray tube potentials, X-ray tube currents and exposure times. The regression analysis of the voltage response of CdS on the tube-potential variation was y=0.0995x-0.1146 ($R^2$=0.9595, $\sigma$=0.08, standard error=2%) and the regression analysis of the voltage response of CdS on the tube-potential variation was y=0.0439x+1.1891 ($R^2$=0.9021, $\sigma$=0.04, standard error=1.8%) The regression analysis of the voltage response of CdS on the X-ray exposure time variation was y=8.2853+5.5878 ($R^2$=0.7287, $\sigma$=0.06, standard error=1.9%). In conclusion, cadmium sulfide responded linearly to the variation X-ray conditions, suggesting cadmium sulfide to be a feasible X-ray sensor of multi-function dosimeter related instruments.

  • PDF

Radiation-Induced Graft Copolymerization of Acrylic Acid onto Polyester

  • Chang, Hoon-Sean;Kong, Young-Kun;Lee, Chong-Kwang;Park, Jae-Ho
    • Nuclear Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.65-74
    • /
    • 1977
  • The radiation-induced graft polymerization of acrylic acid onto polyester fabric was investigated with accelerated electron beams as ratiation source at high dose rates. Homopolymerization was suppressed by addition of cations which is known as homopolymerization inhibitor, but this practical advantage was obtained at the expense of grafting efficiency. The rate of grafting (%/sec) was proportional to the 0.82th power of dose rates over the range from 1.6$\times$10$^{6}$ to 10$\times$10$^{6}$ rad/sec. The grafted polyester fabric showed considerable improvement in moisture regain and antistatic properties.

  • PDF

Neutron Dose Response of Tradescantia Stamen Hair Pink Mutations and RBE (자주달개비 수술털 분홍돌연변이의 중성자 선량반응과 RBE)

  • Kim, Jin-Kyu;Kim, Won-Rok
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.17-23
    • /
    • 1998
  • Dose response relationships for one of biological end-points (gene mutation) in somatic cells of Tradescantia 4430 clones were studied using neutrons coming out of a californium-252 isotopic source. And the relative biological effectiveness (RBE) of neutrons in relation to X-rays in the induction of TSH pink mutations was assessed. Inflorescences were irradiated with X-ray from X-ray generator and neutrons from $^{252}Cf$ source. Irradiated cuttings were incubated with aeration in neutrient solution under the controlled condition. For more than 4 weeks after irradiation cell mutations were scored. Pink mutation frequencies were calculated from the pooled data for the peak interval (days 6 to 13 post-irradiation). Somatic cell mutations in TSH showed linear dose response relationships in the range of neutron doses available for the experiment. The RBE values estimated for neutrons in relation to X-rays were in the range 3.1 to 6.8, which were much lower than normally recognized value.

  • PDF