• Title/Summary/Keyword: 선량지표

Search Result 139, Processing Time 0.023 seconds

Evaluating efficiency of Coaxial MLC VMAT plan for spine SBRT (Spine SBRT 치료시 Coaxial MLC VMAT plan의 유용성 평가)

  • Son, Sang Jun;Mun, Jun Ki;Kim, Dae Ho;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.313-320
    • /
    • 2014
  • Purpose : The purpose of the study is to evaluate the efficiency of Coaxial MLC VMAT plan (Using $273^{\circ}$ and $350^{\circ}$ collimator angle) That the leaf motion direction aligned with axis of OAR (Organ at risk, It means spinal cord or cauda equine in this study.) compare to Universal MLC VMAT plan (using $30^{\circ}$ and $330^{\circ}$ collimator angle) for spine SBRT. Materials and Methods : The 10 cases of spine SBRT that treated with VMAT planned by Coaxial MLC and Varian TBX were enrolled. Those cases were planned by Eclipse (Ver. 10.0.42, Varian, USA), PRO3 (Progressive Resolution Optimizer 10.0.28) and AAA (Anisotropic Analytic Algorithm Ver. 10.0.28) with coplanar $360^{\circ}$ arcs and 10MV FFF (Flattening filter free). Each arc has $273^{\circ}$ and $350^{\circ}$ collimator angle, respectively. The Universal MLC VMAT plans are based on existing treatment plans. Those plans have the same parameters of existing treatment plans but collimator angle. To minimize the dose difference that shows up randomly on optimizing, all plans were optimized and calculated twice respectively. The calculation grid is 0.2 cm and all plans were normalized to the target V100%=90%. The indexes of evaluation are V10Gy, D0.03cc, Dmean of OAR (Organ at risk, It means spinal cord or cauda equine in this study.), H.I (Homogeneity index) of the target and total MU. All Coaxial VMAT plans were verified by gamma test with Mapcheck2 (Sun Nuclear Co., USA), Mapphan (Sun Nuclear Co., USA) and SNC patient (Sun Nuclear Co., USA Ver 6.1.2.18513). Results : The difference between the coaxial and the universal VMAT plans are follow. The coaxial VMAT plan is better in the V10Gy of OAR, Up to 4.1%, at least 0.4%, the average difference was 1.9% and In the D0.03cc of OAR, Up to 83.6 cGy, at least 2.2 cGy, the average difference was 33.3 cGy. In Dmean, Up to 34.8 cGy, at least -13.0 cGy, the average difference was 9.6 cGy that say the coaxial VMAT plans are better except few cases. H.I difference Up to 0.04, at least 0.01, the average difference was 0.02 and the difference of average total MU is 74.1 MU. The coaxial MLC VMAT plan is average 74.1 MU lesser then another. All IMRT verification gamma test results for the coaxial MLC VMAT plan passed over 90.0% at 1mm / 2%. Conclusion : Coaxial MLC VMAT treatment plan appeared to be favorable in most cases than the Universal MLC VMAT treatment planning. It is efficient in lowering the dose of the OAR V10Gy especially. As a result, the Coaxial MLC VMAT plan could be better than the Universal MLC VMAT plan in same MU.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

Biological Markers as Predictors of Radiosensitivity in Syngeneic Murine Tumors (동계 마우스 종양의 방사선 감수성 예측인자로서의 생물학적 표지자)

  • Chang Sei-Kyung;Kim Sung-Hee;Shin Hyun-Soo;Seong Jin-Sil
    • Radiation Oncology Journal
    • /
    • v.24 no.2
    • /
    • pp.128-137
    • /
    • 2006
  • Purpose: We investigated whether a relationship exists between tumor control dose 50 ($TCD_{50}$) or tumor growth delay (TGD) and radiation induced apoptosis (RIA) in syngeneic murine tumors. Also we investigated the biological markers that can predict radiosensitivity in murine tumor system through analysis of relationship between $TCD_{50}$, TGD, RIA and constitutive expression levels of the genetic products regulating RIA. Materials and Methods: Syngeneic murine tumors such as ovarian adenocarcinoma, mammary carcinoma, squamous cell carcinoma, fibrosarcoma, hepatocarcinoma were used In this study. C3H/HeJ mice were bred and maintained in our specific pathogen free mouse colony and were $8{\sim}12$ weeks old when used for the experiments. The tumors, growing in the right hind legs of mice, were analyzed for $TCD_{50}$, TGD, and RIA at 8 mm in diameter. The tumors were also analyzed for the constitutive expression levels of $p53,\;p21^{WAF1/CIP1},\;BAX,\;Bcl-2,\;Bcl-X_L,\;Bcl-X_S$, and p34. Correlation analysis was peformed whether the level of RIA were correlated with $TCD_{50}$ or TGD, and the constitutive expression levels of genetic products regulating RIA were correlated with $TCD_{50}$, TGD, RIA. Results: The level of RIA showed a significant positive correlation (R=0.922, p=0.026) with TGD, and showed a trend to correlation (R=-0.848), marginally significant correlation with $TCD_{50}$ (p=0.070). It indicates that tumors that respond to radiation with high percentage of apoptosis were more radiosensitive. The constitutive expression levels of $p21^{WAF1/CIP1}$ and 34 showed a significant correlation either with $TCD_{50}$ (R=0.893, p=0.041 and R=0.904, p=0.035) or with TGD (R=-0.922, p=0.026 and R=-0.890 p=0.043). The tumors with high constitutive expression levels of $p21^{WAF1/CIP1}$ or p34 were less radiosensitive than those with low expression. Conclusion: Radiosensitivity may be predicted with the level of RIA in murine tumors. The constitutive expression levels of $p21^{WAF1/CIP1}$ or p34 can be used as biological markers which predict the radiosensitivity.

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

Analysis of Exposure Pathways and the Relative Importance of Radionuclides to Radiation Exposure in the Case of a Severe Accident of a Nuclear Power Plant (원전 중대사고시 피폭경로 및 핵종의 방사선 피폭에 대한 상대적 중요도 해석)

  • Hwang, Won-Tae;Suh, Kyung-Suk;Kim, Eun-Han;Han, Moon-Hee;Kim, Byung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.3
    • /
    • pp.209-221
    • /
    • 1994
  • In the case of a severe accident of a nuclear power plant, the whole body dose and the relative importance of the radionuclides during the lifetime of an exposed person were estimated for each exposure pathway with distances from the release point. The external exposure pathways due to immersion of radioactive cloud and deposition of radioactive materials on the ground, and the internal exposure pathways due to inhalation and ingestion of contaminated foodstuffs were considered. The effects due to the ingestion of contaminated foodstuffs were estimated considering the variation of radioactive concentration in the foodstuffs according to deposition time and elapsed time after deposition using a dynamic ingestion pathway model applicable to Korean environment, named 'KORFOOD'. As the results up to 80 km from the release point, the effects due to ingestion of contaminated foodstuffs showed the highest contribution to total exposure dose. The contribution of I isotopes was the highest in the case of the external dose due to immersion of radioactive cloud and internal dose due to inhalation. The contribution of Cs isotopes was highest in the case of the external dose due to deposition of radioactive materials on the ground. In the case of the internal dose due to ingestion of contaminated foodstuffs, Cs deposition in summer and Sr deposition in winter, respectively, were the most dominant radionuclide to whole body.

  • PDF

Measurement of Electron Beam Output for the Prototype Compact Linac (콤팩트 전자 선형가속기 시작품의 출력측정에 관한 연구)

  • Kim, Sung-Woo;Kang, Sang Koo;Rhee, Dong Joo;Lim, Heuijin;Lee, Manwoo;Yi, Jungyu;Lee, Mujin;Yang, Kwangmo;Ro, Tae Ik;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • The C-band compact linear accelerator (linac) is being developed at Dongnam Institute of radiological & Medical Sciences (DIRAMS) for medical and industrial applications. This paper was focused on the output measurement of the electron beam generated from the prototype electron linac. The dose rate was measured in unit of cGy/min per unit pulse frequency according to the IAEA TRS-398 protocol. Exradin-A10 Markus type plane parallel chamber used for the measurement was calibrated in terms of dose to water at the reference depth in water. The beam quality index ($R_{50}$) was determined by the radiochromic film with a solid water phantom approximately due to low energy electrons. As a result, the determined electron beam output was $17.0cGy/(min{\cdot}Hz$. The results were used to monitor the accelerator performance during the development procedure.

Quality Characteristics of Gamma Irradiated-Grain Shape Improved Meju (감마선 조사된 개량메주의 보존 중 품질특성)

  • Kim, Dong-Ho;Lee, Kyong-Haeng;Yook, Hong-Sun;Kim, Jae-Hoon;Shin, Myung-Gon;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.640-645
    • /
    • 2000
  • The effect of gamma-irradiation on the quality changes of the grain shape improved Meju was studied. Meju was prepared, irradiated at 0, 5, 10 and 20 kGy, and then stored at $25^{\circ}C$ for six months. The results showed that the fungi and acid producing bacteria were completely eliminated by gamma-irradiation with dose of 10 kGy or higher and the Bacillus was decreased by 5 log cycles with dose of 10 kGy. The $D_{10}$ values of the fungi, Bacillus and acid producing bacteria were 0.79, 2.28 and 1.17 kGy, respectively. Also, the microorganisms that survived irradiation was decreased significantly with the duration of storage period. The $NH_3-nitrogen$, negative factors of quality of Meju, and browning were repressed and the protease activity and pH were not affected by gamma-irradiation. Therefore, it was considered that the Meju treated with gamma-irradiation maintained better quality than that of the control with storage.

  • PDF

Comparison of Radiation-Induced Hydrocarbons in Dried Anchovies by Electron-Beam Irradiation (전자선 조사한 건조 멸치류에서 유도된 지방분해산물의 분석)

  • Hong, Young Shin;Kim, Kyong Su
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.12
    • /
    • pp.1889-1895
    • /
    • 2014
  • Radiation-induced hydrocarbon contents of dried anchovy, jiri anchovy, and large-eyed herring were evaluated following electron-beam irradiation at doses of 1, 3, 5, 7, and 10 kGy. GC/MS identification of the induced hydrocarbons by irradiation was conducted after lipid separation by soxtec, followed by florosil column chromatography. 1-Tetradecene ($C_{14:1}$) and pentadecane ($C_{15:0}$) derived from palmitic acid, 1-hexadecene ($C_{16:1}$) and heptadecane ($C_{17:0}$) from stearic acid, and 8-heptadecene ($C_{17:1}$) and 1,7-hexadecadiene ($C_{16:2}$) from oleic acid were the major induced hydrocarbons in irradiated dried anchovy, jiri anchovy, and large-eyed herring samples. At the same irradiation dose, concentration of induced hydrocarbons differed from fatty acid composition and increased in accordance with radiation dose level. Radiation-induced hydrocarbons, such as 1-tetradecene ($C_{14:1}$), 1-hexadecene ($C_{16:2}$), 8-heptadecene ($C_{17:1}$), and 1,7-hexadecadiene ($C_{16:2}$), were confirmed as irradiation marker compounds. Therefore, these marker compounds could be used to distinguish electron-beam irradiated dried anchovy, jiri anchovy, and large-eyed herring from non-irradiated ones.

강지진동 분석의 최적화를 위한 고려요소

  • 이석태;조봉곤;이정모;조영삼
    • Proceedings of the International Union of Geodesy And Geophysics Korea Journal of Geophysical Research Conference
    • /
    • 2003.05a
    • /
    • pp.17-17
    • /
    • 2003
  • 한반도에 있어서의 지진의 영향을 분석하기 위해서는 강지진동 연구가 필수적이다. 강지진동 자료가 부족한 한반도의 특성상 모사를 통해 연구하고 있다. 강지진동 분석을 하기 위해서는 되도록 노이즈가 포함되어 있지 않은 지진파자료를 선택하여 그 지진자료의 스펙트럼 분석을 통해 감쇠상수 k, Q 등을 구한다. 이러한 감쇠상수 값을 통해 한반도의 진동 특성을 이해할 수 있다. 그러나 감쇠상수를 구하는 과정에서 감쇠상수 분석에 사용된 지진자료에 노이즈가 더해졌을 경우, 어떤 형태로 스펙트럼 영역에 영향을 미치고, 감쇠상수에는 어떤 영향을 미치는 지를 연구하여 노이즈효과를 제거할 수 있는 최적화된 분석에 관한 연구가 선행되어야 한다고 본다. 따라서 이번 연구에서는 강지진동 모사프로그램을 가지고 노이즈효과를 적용하면서 감쇠상수에 노이즈가 어떤 영향을 미치는 지에 대한 수치 해석적 연구를 실시하였다. 합성지진파에 이 합성지진파와 전혀 다른 주파수 형태를 보이는 노이즈를 강도를 달리하면서 합성해 본 결과, 노이즈효과를 고려할 수 있는 몇 가지 요소가 있음을 알 수 있었다. 감쇠상수 k값을 강지진동 모사프로그램으로부터 값을 달리하며 합성해 본 결과 노이즈효과를 보이는 것을 알 수 있었으며, 감쇠상수 k를 선형회귀를 통해 $k_{s}$$k_{q}$를 구할 때의 적용 주파수 범위를 변화시켰을 때도 일정한 양상의 노이즈 효과를 보였다. 또 지진자료와 노이즈를 중첩시킨 지진파 시계열 자료의 정부분만을 감쇠상수 k를 구하는 선형회귀에 이용했을 경우에도 노이즈 효과를 보였다. 또한 계산되어 나온 감쇠상수 값으로부터 특정지역의 지반운동의 특성을 이해할 수 있는 스펙트럼 가속도, 최대 가속도, 및 최대속도 값에 따른 감쇠식을 구하였다. 이것을 한반도와 같은 판 내부 환경인 ENA 값과 비교하였으며 기존의 연구와도 비교하였다.심으로부터 지오이드까지의 거리, 지오이드로부터 지표까지의 거리를 정의해주었으며, 각 격자점의 수직구조를 정의하기 위해 깊이에 따른 각 매질의 밀도, P파의 속도, S파의 속도, P파에 대한 Q값, S파에 대한 Q값을 정의 해주었다. S파의 속도를 구하기 위해서 지구 내부 물질을 포아송 매질이라는 가정 하에, 관계식을 $Vp{\;}={\;}SQRT(3){\;}{\times}{\;}Vs$ 이용하였다. 획득한 모델치들을 이용해 동해와 동해 인근 지역에 대한 초기모델을 구축하였다. 약 1 × 10/sup 6/ e/sup -//sec·n㎡ 의 전자선량에 해당되며 이를 기준으로 각각의 illumination angle에 대한 임계전자선량을 평가할 수 있었다. 실질적으로 Cibbsite와 같은 무기수화물의 직접가열실험 시 전자빔 조사에 의해 야기되는 상전이 영향을 배제하고 실험을 수행하려면 illumination angle 0.2mrad (Dose rate : 8000 e/sup -//sec·n㎡)이하로 관찰하고 기록되어야 함을 본 자료로부터 알 수 있었다.운동횟수에 의한 영향으로써 운동시간을 1일 6시간으로 설정하여, 운동횟수를 결정하기 위하여 오전, 오후에 각 3시간씩 운동시키는 방법과 오전부터 6시간동안 운동시키는 두 방법을 이용하여 품질을 비교하였다. 각 조건에 따라 운동시킨 참돔의 수분함량을 나타낸 것으로, 2회(오전 3시간, 오후 3시간)에 나누어서 운동시키기 위한 육의 수분함량은 73.37±2.02%를 나타냈으며, 1회(6시간 운동)운동시키기 위한 육은 71.74±1.66%을 나타내었다. 각각의 운동조건에서 양식된 참돔은 사육초기에는 큰 변화가 없었으나, 사육 5일 이후에는 수분함량이 증가하여 15일에는 76.40±0.14, 75.62±0.98%의 수분함량을 2회와 1회 운동시킨 참돔의 육에서 각각 나타났다. 운동횟수에 따른 지

  • PDF

Changes of Chemical Properties in Processing of Low Salted and Fermented Shrimp Using Gamma Irradiation immediately before Optimum Fermentation (저염 새우젓 제조를 위한 최적 숙성직전의 감마선 조사시 화학적 품질변화)

  • Lee, Kyong-Haeng;Ahn, Hyun-Joo;Lee, Cherl-Ho;Kim, Yeung-Ji;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.1051-1057
    • /
    • 2000
  • Gamma irradiation was applied to develop fermented shrimp product with lower salt concentration, high sensory quality and storage stability. Shrimp was prepared with 15 and 20% of salt and fermented at $15^{\circ}C$. The sample was irradiated for 15% added salt at the 4th week and for 20% at the 6th week during fermentation with 0, 5 and 10 kGy absorbed doses. The irradiation was applied at optimum stage of fermentation determined when the content of amino nitrogen(AN) arrived approximately 400 mg%. Chemical properties such as amino nitrogen(AN), volatile base nitrogen(VBN), trimethylamine(TMA) and neutral protease activity were examined during whole fermentation. The AN, VBN, TMA and protease activity were not affected immediately after gamma irradiation. The more NaCl concentrations and irradiation dose, the less content of chemical compounds and protease activity was found. From the results of chemical properties, it was concluded that fermented shrimp with 15% of salt and irradiated at 10 kGy before optimum fermentation, or 20% and 5 kGy or above were maintained the sound quality during storage compared with the control.

  • PDF