• Title/Summary/Keyword: 생체표지

Search Result 94, Processing Time 0.03 seconds

Real-time Highly Sensitive Measurement of Myocardial Infarction Biomarkers Using Silicon-based Ellipsometric Biosensors (실리콘 기반 타원편광계식 바이오센서를 이용한 심근경색 생체표지자의 실시간 초고감도 진단 농도 측정)

  • Min, Yoon Gi;Cho, Hyun Mo;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.2
    • /
    • pp.59-66
    • /
    • 2019
  • We report highly sensitive detection of myocardial infarction biomarkers, such as myoglobin and cTnI, within several hundred seconds using a rotating-analyzer ellipsometer and a biosensor with biochips fabricated on a $SiO_2$-coated tilted silicon substrate. We choose the running buffer to be pure phosphate-buffered saline (PBS) or 10% mixed human serum. When we choose the running buffer to be pure PBS, we obtain diagnostic densities of pure myocardial infarction biomarkers of up to 1 ng/ml and 5 pg/ml respectively. Meanwhile, when we use PBS with 10% human serum, the measured densities of myoglobin and cTnI were up to 1 ng/mL and 1 pg/mL respectively. The measured diagnostic densities are less than 1/15 and 1/80 (in cases of myoglobin and cTnI respectively) of those referenced by the World Health Organization.

Application of DNA Test for Individual Traceability in Hanwoo (Korean Cattle) (한우의 개체 추적 검증을 위한 유전자 감식 기법 활용 연구)

  • 이학교;전광주;공홍식;오재돈;최일신;김종대;조창연;윤두학;신형두
    • Food Science of Animal Resources
    • /
    • v.24 no.1
    • /
    • pp.8-14
    • /
    • 2004
  • Identification of animals has been made with an ear tag with dummy code, and blood typing has been used for paternity and individual identification in live animals. As various genetic markers are for different cattle breeds vary, the discrete genetic markers are necessary to identify Hanwoo. A total of 740 progeny testing Hanwoo were used to identify Hanwoo specific markers. To examine traceability of individuals by using breed specific genetic codes, four animal were randomly sampled, and traced from live animals to post-slaughter processing stages. The candidate genetic makers used in the study were 16 DNA microsatellites which were identified in romosomes 1 and 14. The number of alleles of those DNA microsatellites ranged from a minimum of 3 to maximum of 12. The heterozygote frequency ranged from 0.022 to 0.824. Effective number of alleles for each DNA microsatellites were 3 to 6. Six selected candidate genetic markers were able ti trace individual cattle with an 100% confidence level.

Biodistribution Study of $^{99m}Tc$-Labeled Succinic Acid-Conjugated Low pI Avidin (낮은 동전점을 갖는 $^{99m}Tc$ 표지 Succinic Acid 결합 Avidin의 생체내분포에 관한 연구)

  • Jeong, Jae-Min;Paik, Chang-H.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.285-292
    • /
    • 1993
  • Avidin과 biotin의 높은 결합력을 이용하여 종양 영상을 개선하는 방법이 많이 연구되고 있다. 본 실험에서는 이러한 목적으로 쓰기 위하여 적당한 $^{99m}Tc$ 표지 avidin을 제조하였다. Avidin을 표지하기 위하여 우선 $^{99m}Tc$과 안정한 킬레이트를 형성할 수 있는 benzoylmercaptoacetyltriglycine (Bz-MAG3)과 biocytin을 화학적으로 결합시킨 Bz-MAG3-biocytin을 합성하였다. 이 화합물을 Tc-99m으로 표지시켜 avidin 또는 streptavidin을 1:1로 섞어 줌으로서 Tc-99m으로 표지된 avidin과 streptavidin을 제조하였다. 이들의 생쥐 생체내 분포를 조사한 결과 avidin의 경우 높은 간(56.6%, 10min)과 신장(28.5%, 10min) 축적을 보였고 streptavidin의 경우 높은 신장 축적 (28.9%, 21hr)을 보였다. Avidin의 높은 정상 조직 축적을 줄이기 위하여 succinic acid를 결합시켜 등전점(pI)을 낮춘 다음 같은 실험을 하여 본 결과 신장 축적율은 pI가 $7.0{\sim}9.3,\;5.5{\sim}6.2,\;4.0{\sim}4.8$로 낮아졌을 경우 19.0%, 3.1%, 1.7%로 각각 떨어졌지만 간에의 축적은 pI 변화에 따른 상관성을 찾아 볼 수가 없었다. 체내 제거율을 측정하여 본 결과 pI를 변화시킨 avidin과 변화시키지 않은 avdin들은 반감기가 13.5에서 16.0시간 사이로 큰 차이점을 보이지 않았는데 streptavidin은 반감기 61.5시간 정도로 느리게 제거된다는 것을 알았다. 이 실험의 결과 1. Avidin을 $^{99m}Tc$-MAG3-biocytin으로 안정하게 표지할 수 있었고, 2. pI가 낮아진 avidin은 신장에의 축적율이 크게 감소되었으며, 3. $^{99m}Tc$으로 표지된 avidin과 streptavidin은 먼저 간으로 흡수된 후 대사된 다음 신장으로 배설된다는 사실을 알았다.

  • PDF

Effect of Carrier on Labeling and Biodistribution of Re-188-Hydroxyethylidene diphosphonate (담체가 Re-188-Hydroxyethylidene Diphosphonate의 표지와 생체내분포에 미치는 영향)

  • Chang, Young-Soo;Jeong, Jae-Min;Kim, Bo-Kwang;Cho, Jung-Hyuk;Lee, Dong-Soo;Chung, June-Key;Lee, Seung-Jin;Jin, Ren-Jie;Lee, Sang-Eun;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.344-352
    • /
    • 2000
  • Purpose: Re-188-Hydroxyethylidene diphosphonate (HEDP) is a new cost-effective agent for systemic radioisotope therapy of metastatic bone pain. We investigated the influence of carrier for labeling and biodistribution of Re-188-HEDP using HEDP kit with or without carrier ($KReO_4$). Materials and Methods: The kits (HEDP 15 mg, gentisic acid 4 mg and $SnCl_2.2H_2O_2$ 4.5 mg) with or without carrier ($KReO_4$ 0.1 mg) were labeled with Re-188 solution, made available from an in-house generator by boiling for 15 min. We compared the labeling efficiency and stability of carrier-added and carrier-free preparations of Re-188-HEDP Biodistribution and imaging studies of each preparation were performed in ICR mice ($1.85{\sim}3.7MBq/0.1ml$) and SD rats ($74.1{\sim}85.2MBq/0.5ml$). Results: The carrier-added preparation showed high labeling efficiency (95% at pH 5) and high stability in serum (88%, 3 hr). However, the carrier-free preparation showed low labeling efficiency (59% at pH 5) and low stability (43%, 3 hr). The carrier-added preparation showed high uptake in bone and low uptake in stomach and kidneys. However, the carrier-free preparation showed lower uptake in bone and higher uptake in both stomach and kidneys, which is supposed to be due to released perrhenate. The carrier-added preparation also showed better images with higher skeletal accumulation, lower uptake in other organs and lower soft tissue uptake than the carrier-free preparation. Conclusion: The results of these studies clearly demonstrate that addition of carrier perrhenate is required for high labeling efficiency, stability, bone uptake and good image quality of Re-188-HEDP.

  • PDF

공진반사광 바이오센서를 이용한 심근경색 마커 감지 기술

  • Heo, Cheol;Kim, Bong-Gyu;Kim, Wan-Jung;Hong, Jong-Cheol;A, Chil-Seong;Kim, Sang-Hyeop;Seong, Geon-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.127-127
    • /
    • 2014
  • 인체 내 소량의 생체성분(혈액, 소변 등)을 감지하는 바이오센서 기술은 질병 진단뿐만 아니라 예방 및 관리로 의료서비스 확대, 개인 맞춤형 진료 및 의료비 감소 효과를 가져올 수 있는 기술이다. 광바이오센서는 광학적인 측정방법을 이용하여 다양한 생화학물질들의 상호 반응을 검출해 낼 수 있는 바이오센서로 현재 활발하게 연구가 진행되고 있다. 광 바이오센서는 생체성분 내에 존재하는 전하를 가진 많은 이온들 및 Salt 농도 등에 영향을 받지 않기 때문에 나노 와이어를 이용한 FET (field-effect transistor)형 바이오센서에 비해 많은 장점을 가지고 있다. 일반적으로 광 바이오센서는 형광물질, 인광물질, 발색물질, 방사선 물질 등의 발광물질을 인식물질에 표지하여 인식물질과 분석물질과의 반응유무를 표지된 발광물질의 광학 신호를 감지하여 분석물질을 검출해내는 표지식 광 바이오센서 기술이 상용화되고 있다. 그러나 이러한 분석 방법은 민감도는 우수하지만 분석 시간이 매우 느리고, 고가의 분석 장비 및 복잡한 제조 공정 등의 단점들을 가지고 있다. 이러한 단점들을 극복하기 위하여 생화학 반응 유무를 표지물질 없이 광학적 방식으로 직접 측정할 수 있는 비표지식 광 바이오센서 기술이 최근 들어 많이 연구되고 있다. 본 논문에서는 광파장 이하의 주기를 가진 주기적 공진 격자 표면에서 일어나는 바이오 항원-항체 반응에 대한 공진 반사 파장을 측정하여 생체성분 내에 존재하는 바이오 항원을 고감도로 검출할 수 있는 비표지식 공진반사광 바이오센서 기술을 소개하고자 한다. 공진반사광 바이오센서를 이용하여 human serum내에 존재하는 심근경색 마커인 troponin I (cTnI), creatine kinase MB (CK-MB), myoglobin (MYO)을 0.1 ng/mL 이하의 농도까지 고감도로 측정할 수 있었다.

  • PDF

Studies on the Preparation of Radioactive iodine Labelled Concanavalin-A, Lectin Extracted from Korean Native Plant “Banha”, and Their Conjugation Products and the Hemagglutination Tests of These Labelled Compounds in Vitro.

  • Kim, You-Sun;Park, Kyung-Bae
    • Nuclear Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.1-12
    • /
    • 1978
  • Concanavalin-A, lectin extracted from Korean native plant “Banha”(Pine-llia Termata) and their conjugation products with tyrosine and 5-iodo-6-aminouracil were labelled by radioactive iodiae-125, and these labelled compounds were subjected to a hemagglutination test in vitro. The labelling procedures were presented with respect to labelling yield and the trends on the conjugation reaction of lectin with various amino acids were discussed. The preliminary results on the hemagglutination tests against cancer tissues were presented and the potential clinical applications of these labelled compounds were discussed.

  • PDF

돼지 과배란 처리에 의한 배란상태와 혈액 성분과의 비교분석

  • 이연근;이현기;박진기;이풍연;이주영;정학재;장원경
    • Proceedings of the KSAR Conference
    • /
    • 2004.06a
    • /
    • pp.232-232
    • /
    • 2004
  • 본 연구는 돼지의 발정동기화에 의한 과배란 유기시 돼지 난소의 배란상태(황체수)와 혈액내 혈액성분(WBC, RBC Hb, HCT, MCV, MCH, MCHC, Platelet)과의 비교분석을 통하여 다배란에 따른 표지(Marker) 혈액성분을 구명하기 위하여 실시하였다. 돼지 난소의 배란상태를 구명하기 위하여 30두의 성축 암컷을 이용하였으며, 발정 동기화는 PG 600(PMSG 400 IU, HCG 200IU)을 주사한 후 10일 후에 Regumate porcine을 6일간 급여한 후에 PMSG 주사하고 2일 후에 hCG주사한 다음날 자연종부를 실시하여 수정에 이르게 하였다. (중략)

  • PDF

공진반사 및 플렉시블 광 바이오센서 기술

  • Heo, Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.106-106
    • /
    • 2012
  • 인체 내 소량의 생체성분을 감지하는 바이오센서 기술은 질병 진단뿐만 아니라 예방 및 관리로 의료서비스 확대 및 의료비 감소 효과를 가져올 수 있는 기술이다. 광 바이오센서는 광학적인 측정방법을 이용하여 다양한 생화학물질들의 상호 반응을 검출해 낼 수 있는 바이오센서로 현재 활발하게 연구가 진행되고 있다. 일반적으로 형광물질, 발색물질 등의 발광물질을 인식물질에 표지하여 인식물질과 분석물질과의 반응 유무를 표지된 발광물질의 광 신호를 감지하여 분석물질을 검출해내는 표지식 광 바이오센서 기술이 상용화되고 있다. 그러나 이러한 분석 방법은 민감도는 우수하지만 분석 시간이 매우 느리고, 고가의 분석 장비를 필요로 하는 단점들을 가지고 있다. 이러한 단점들을 극복하기 위하여 생화학 반응 유무를 표지물질 없이 광학적 방식으로 직접 측정해내는 비 표지식 광 바이오센서 기술이 최근 들어 많이 연구되고 있다. 본 논문에서는 비표지식이면서 분광기 없이 분석 가능한 공진 반사광 바이오센서 기술에 관한 내용을 소개하고자 한다. 공진 반사광 바이오센서는 광파장 이하의 주기를 가진 주기적 공진 격자 표면에서 일어나는 항원-항체 반응에 대한 공진 반사 파장을 측정하여 원하는 바이오물질을 고감도로 검출할 수 있는 바이오센서이다. 또한, 인체 내장을 위하여 플렉시블 기판 상에 GaN LED를 집적하여 전립선암 바이오 마커 검출에 대한 결과를 소개하고자 한다.

  • PDF