• Title/Summary/Keyword: 생물광자

Search Result 22, Processing Time 0.024 seconds

Evaluation of Anti-AFP Monoclonal Antibodies as Immunodiagnostic Reagents for Hepatocellular Carcinoma (항-AFP 단일클론 항체를 이용한 간암진단 효과의 검토)

  • 현광자;강희갑;강신성
    • The Korean Journal of Zoology
    • /
    • v.38 no.3
    • /
    • pp.382-387
    • /
    • 1995
  • To check the possible application of our anti-AFP monocional antibodies (MAbs) as immunodiagnostic reagents for hepatocellular carcinoma, ELISA and immunohistochemical assay were performed on the sera and liver biopsy specimens from the patients of hepatocellular carcinoma and other non-malignant hepatic disease. By non-competitive ELISA using anti-AFP MAbs, the highest incidence of AFP value was found only in the sera of hepatocellular carcinoma patients, i.e., more than 54% of patients had serum AFP levels of more than 500 ng/mi. By immunoperoxidase and indirect immunofluorescence techniques, anti-AFP MAbs were found to react with cytoplasm of hepatoceliular carcinoma cells. However immunohistochemical reactIvity to AFP in hepatocellular carcinoma cells was lower than that in non-neoplastic liver cells adjacent to the hepatocellular carcinoma. From these results with the similar findings from other studies, we suggest that AFP antigen is appropriate in the diagnosis assay (ELISA) but is not by immunohistochemical detection.

  • PDF

Effects of Light Intensity and Nutrient Level on Growth and Quality of Leaf Lettuce in a Plant Factory (식물공장내 광도와 배양액농도가 상추의 생육과 품질에 미치는 영향)

  • Park, Mi-Hee;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.8 no.2
    • /
    • pp.108-114
    • /
    • 1999
  • This study was conducted to investigate the optimum environment for leaf lettuce (Lactuca sativa L. var. crispa) in a plant factory to increase mass-production efficiency of quality leaf lettuce. Transpiration rate and $CO_2$ assimilation rate were increased with increasing the photosynthetic photon flux density (PPFD). The highest fresh weight and dry weight were observed at the PPFD of 200 and 300 U moi $m^{-2}$ $s^{-l}$, respectively. The optimum aerial environment for the growth and quality of leaf lettuce in the plant factory was determined to be over 200 $\mu$mol $m^{-2}$ $s^{-1}$ for PPFB. Although the interaction between light intensity and nutrient level was not significant, the lettuce growth was the best under electrical conductivity (EC) of 1.8 mS $cm^{-1}$ / at high light intensity (250 $\mu$mol $m^{-2}$ $s^{-1}$ ) and EC of 2.4 mS cm-1 at low light level (150 $\mu$mol $m^{-2}$ $s^{-1}$ ) respectively.y.

  • PDF

Review of Biophoton of Human Beings - Domestic Papers (인체에서 방사되는 생물광자(生物光子)에 대한 소고)

  • Yi Seung-Ho;Kim Jin-Soo;Park Hi-Joon;Yang Joon-Mo;Soh Kwang-Sup;Lim Sabina
    • The Journal of Korean Medicine
    • /
    • v.27 no.1 s.65
    • /
    • pp.57-77
    • /
    • 2006
  • Objectives : The purpose of this study is to review research papers published by Korean research groups on biophoton of human beings based on experiment subject and methodology. Methods : In order to review human biophoton research executed in Korea, all the papers published in Korean and international journals by Korean research groups were selected. Several key foreign papers were also reviewed for clarification of this study. Based on experiment subjects, experiment methodology, and interpretation of experiment results were analyzed. On each experiment, its original interpretation was directly quoted. Issues on the experiment methodology and interpretation were expressed at the end of each subject. Results and Conclusions : We found that experiments on human biophoton were compelling. However it seemed that more experiments, especially on their sample sizes, are needed to demonstrate its clinical application. Interpretations based on Korean traditional medicine also need to be elaborated more. In order to do accomplish clinical application of biophoton, interdisciplinary works are required. Some suggestions on biophoton experiments were made.

  • PDF

Reduced Regional Cerebral Blood Flow in Patients with Traumatic Brain Injury Who Had No Structural Abnormalities on Magnetic Resonance Imaging : A Quantitative Evaluation of Tc-99m-ECD SPECT Findings (정상 MRI 소견을 보이는 외상성 뇌손상 환자에서 국소뇌혈류량의 이상)

  • Kim, Nam-Hee;Chung, Young-Ki
    • Korean Journal of Biological Psychiatry
    • /
    • v.9 no.2
    • /
    • pp.152-158
    • /
    • 2002
  • Background & Purpose:Neuropsychological disorders after traumatic brain injury(TBI) are poorly correlated with structural lesions detected by structural neuroimaging techniques such as computed tomography(CT) scan or magnetic resonance imaging(MRI). It is well known that patients with TBI have cognitive and behavioral disorders even in the absence of structural lesions of the brain. This study investigated whether there are abnormalities of regional cerebral blood flow(rCBF) in TBI patients without structural abnormality on MRI, using technetium 99m ethyl cysteinate dimer(Tc-99m-ECD) single photon emission computed tomography(SPECT) scans. Materials and Methods:Twenty-eight TBI patients without structural abnormality on MRI(mild, n=13/moderate, n=9/severe, n=6) and fifteen normal controls were scanned by SPECT. A voxel-based analysis using statistical parametric mapping(SPM) was performed to compare the patients with the normal controls. Results:rCBF was reduced in the right uncus and the right lateral orbitofrontal gyrus in the TBI patients. However, no increase of rCBF was noted in the patients in comparison to the normal controls. Conclusions:These results suggest that the TBI patients, even in the absence of structural lesion of the brain, may have dysfunction of the brain, particularly of the orbitofrontal and anterior pole of the temporal cortex. They also suggest that SPECT can be a useful method to identify brain dysfunctions in combination with structural brain imaging and neuropsychological tests.

  • PDF

Biophoton Emission as a Biomarker of Mouse Fatty Liver induced by Carbon Tetrachloride (사염화탄소를 이용한 마우스 지방간에서의 새로운 생체발광 측정법)

  • 김정대;임재관;최준호;이병천;유혜란;박대훈;천병수;소광섭
    • KSBB Journal
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2004
  • Recently the measurement of biophoton emission has attracted increasing attention in the study on physiological state of biological systems. We report the measurements of biophoton emission from the mouse fatty liver induced by carbon tetrachloride, CCl$_4$. The hepatotoxin, CCl$_4$ in olive oil, was injected intraperitoneally into two groups of ICR mice which were made of 6 mice in each group. The control groups corresponding to the treated groups were prepared with the injections of olive oil only. After the injections, livers of two groups were extracted and measured biophoton emission in 24 hours and 72 hours later, respectively. We also extracted the plasma in the blood and measured the transaminase activity. Results show that biophoton emission from the livers in 24-hour treated group is 69.3${\pm}$21.2 counts/min/$\textrm{cm}^2$, which is two times more larger than that in 24-hour control group, 29.5${\pm}$5.9 counts/min/$\textrm{cm}^2$ Biophoton emission from the livers in 72-hour treated group is 37.0${\pm}$14.8 counts/min/$\textrm{cm}^2$. These biophoton results correlate with those of the biochemical assays. We conclude that biophoton emission can be used as a biomarker of mouse fatty liver induced by CCl$_4$.

The Scattering and Absorption Effects of Fluorescence Spectroscopy in a Real Time Optical Biopsy (실시간 광학적 생검에서 형광분광법의 산란과 흡수에 대한 영향)

  • Han, Seunghee;Muller, Markus G.;Kang, Seunghee;Kang, Haejin
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.79-94
    • /
    • 2001
  • The fluorescence emanating from a biological tissue contains information about scattering, absorption and the intrinsic fluorescence (fluorescence only due to fluorophores). Becaue fluorescence spectra of biological tissue are often significantly affected by the presence of tissue absorbers and scatterers, the measured tissue fluorescence cannot be interpreted as a linear combination of intrinsic fluorescence spectra of different tissue biochemical. We conducted experiments to examine the influence of scattering and absorption on the experimentally measured fluorescence of a turbid medium such as biological tissue. Therefore, we acquired fluorescence and reflectance spectra of tissue phantoms with a wide range of scatterer and absorber concentrations. By applying a photon migration model, which uses the scattering and absorption information contained in reflectance spectra to remove their distortion also present in fluorescence spectra, we extract the intrinsic fluorescence of these tissue models. We achieved excellent agreement between modeled and actual intrinsic fluorescence spectra. The motivation for this research is that intrinsic fluorescence spectra are expected to change with progression of disease in human tissue, due to changes in the tissue biochemical composition. It is not possible to distinguish the two tissue types by using only the measured fluorescence, however clear separation can be achieved with the intrinsic fluorescence in real time optical biopsy.

  • PDF

The Change of Biophoton Emission on Acupuncture Stimulus and Environment Condition in Healthy Volunteers (환경조건 및 침자극에 따른 인체 생물 광자 방출량 변화에 관한 연구)

  • Ryu, Yeon-Hee;Jung, Sang-Yong;Hwang, Hye-Suk;Kim, Yoo-Sung;Lee, Young-Seop;Yang, Eun-Jin;Choi, Sun-Mi
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.2
    • /
    • pp.35-39
    • /
    • 2008
  • Objective: Recently biophysical research has shown very weak radiation of photons in plant, animal and human cells. Biophoton emission of the aliving system has received specific phenomena because of its scientific potential for monitoring metabolism to human body. This paper proposes a new challenge possibility of the biophoton emission in biophysiological human condition index. Method: Biophoton emission were measured with twenty one healthy volunteers. The study analyses existence for the effect of specific acupoint stimulus, exposure to the sun and low temperature in healthy volunteers. Two photomultiplier tubes which spectral range was from 300 nm to 650 nm was used for the detection of biophoton emission observation of possible acupuncture stimulation effect at left hand palm. Result: There was a reversion of relative emission rates from the palms affected the environment condition. Otherwise, when the acupuncture stimulation, the emission rate was not enough significantly change(p<0.05). Conclusion: In this study, biophoton emissions depend on the environment condition for all subjects. Measurments with the biophoton emission rate analysis might be much considered in future studies.

  • PDF

Delayed Luminescence Characteristics of Human Hands (사람 손의 지연발광 특성)

  • Yang, Joon-Mo;Choi, Chun-Ho;Soh, Kwang-Sup;Lim, Woo-Taek;Lee, Han-Sang;Chae, Seung-Byung;Yoon, Se-Yeol;Lee, Kyung-Il;Shin, Eun-Seok;Choi, Sun-Mi
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.81-88
    • /
    • 2006
  • Delayed luminescence from human hands after illumination by light at different wavelength bands was studied. A delayed luminescence measurement system equipped with photomultiplier tube (PMT), fiber optics and automatic mechanical shutter system was developed. Three spectrum band-pass filters, fer which transmissions are on 350${\~}$450 nm, 450${\~}$550 nm and 550${\~}$650 nm, were used to select irradiation wavelength, and 150W metal-halide lamp was used as an illumination source. Six volunteers put their palms (dorsa) onto the measurement system, and after light illumination, delayed luminescence were measured for 10 minutes. The results show that delayed luminescence after shorter wavelength illumination was higher than that a(ter longer wavelength one. These results indicate the existence of accepters in human skin which can be excited at short wavelengths. Furthermore, each subjects showed different delayed luminescence curve patterns. Reactive oxygen species (ROS) are known to have important roles on delayed luminescence, and this research suggests that ROS concentration can be measured noninvasively with optical methods.

Evaluation of Radiation Exposure Dose for Examination Purposes other than the Critical Organ from Computed Tomography: A base on the Dose Reference Level (DRL) (전산화단층촬영에서 촬영 목적 부위와 주변 결정장기에 대한 피폭선량 평가: 선량 권고량 중심으로)

  • Lee, Seoyoung;Kim, Kyunglee;Ha, Hyekyoung;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.121-129
    • /
    • 2013
  • In this study measured patient exposure dose for purpose exposure area and peripheral critical organs by using optically stimulated luminescence dosimeters (OSLDs) from computed tomography (CT), based on the measurement results, we predicted the radiobiological effects, and would like to advised ways of reduction strategies. In order to experiment, OSLDs received calibration factor were attached at left and right lens, thyroid, field center, and sexual gland in human body standard phantom that is recommended in ICRP, and we simulated exposure dose of patients in same condition that equal exposure condition according to examination area. Average calibration factor of OSLDs were $1.0058{\pm}0.0074$. In case of left and right lens, equivalent dose was measure in 50.49 mGy in skull examination, 0.24 mGy in chest, under standard value in abdomen, lumbar spine and pelvis. In case of thyroid, equivalent dose was measured in 10.89 mGy in skull examination, 7.75 mGy in chest, 0.06 mGy in abdomen, under standard value in lumber spine and pelvis. In case of sexual gland, equivalent dose was measured in 21.98 mGy, 2.37 mGy in lumber spine, 6.29 mGy in abdomen, under standard value in skull examination. Reduction strategies about diagnosis reference level (DRL) in CT examination needed fair interpretation and institutional support recommending international organization. So, we met validity for minimize exposure of patients, systematize influence about exposure dose of patients and minimize unnecessary exposure of tissue.

Determination of TRS-398 Quality Factors for Cs-137 Gamma Rays in Reference Dosimetry (Cs-137 감마선의 선량측정을 위한 TRS-398 선질인자 결정에 관한 연구)

  • Kang, Sang Koo;Rhee, Dong Joo;Kang, Yeong Rok;Kim, Jeung Kee;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.123-127
    • /
    • 2014
  • The Cs-137 irradiator is widely used to irradiate biological samples for radiobiological research. To obtain the accurate outcomes, correct measurements of the delivered absorbed dose to a sample is important. The IAEA protocols such as TRS-277 and TRS-398 were recommended for the Cs-137 reference dosimetry. However in TRS-398 protocol, currently known as the most practical dosimetry protocol, the quality factor ($k_{Q,Q_0}$) for Cs-137 gamma rays is not suggested. Therefore, the use of TRS-398 protocol is currently unavailable for the Cs-137 dosimetry directly. The calculation method previously introduced for high energy photon beams in radiotherapy was used for deriving the Cs-137 beam qualities ($k_{Q,Q_0}$) for the 15 commercially available farmer type ionization chambers in this study. In conclusion, $k_{Q,Q_0}$ values were ranged from 0.998 to 1.002 for Cs-137 gamma rays. These results can be used as the reference and dosimeter calibrations for Cs-137 gamma rays in the future radiobiological researches.