• Title/Summary/Keyword: 상황조명

Search Result 351, Processing Time 0.03 seconds

The Research on the Life-safety Implementation using the Natural Light LED Lamp in the Disaster Prevention and Safety Management (방재안전 자연광 LED 조명을 이용한 생활안전 개선에 관한 연구)

  • Lee, Taeshik;Seok, Gumcheul;So, Yooseb;Choi, Byungshik;Kim, Jaekwon;Cho, Woncheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.53-62
    • /
    • 2016
  • This paper is shown the new method using LED Light, which the light environment is upgraded the natural LED light in the area of Disaster Prevention and Safety Management (PDSD), which the events of deaths is reduced on the Suicide, the Infectious diseases, the safety accidents, the Traffic Accident, the crime, the fire, the Nature Disaster, and which the health and the environment and the safety is implemented using the value of the color LED Light. Research findings include,during 3 weeks in the November 2016, in the ten residents (average living 28.7 years, age 67.5 years) with depressive symptoms in the northern part of Seoul, according to the request of the user, the PDSD natural light LED lighting was installed in the home bedroom or the living room, expectations for the ability to restore physical and mental stability were high (88%), in the same way, after 1 week and 3 weeks, the physical and mental changes were compared and the results,84% in the first week and 90% in the third week and thereafter, the effect of relieving depression was high. We conclude that patients with depression have a good sleep, an uneasy feeling, a sense of security, a good night's sleep, and a good feeling. The PDSD LED Light is expected to contribute in the various areas, which reduced the suicides, which give increased immunity from infectious diseases, which give a crash to reduce accidents caused by negligence, which improve the safe operation of heavy vehicles in which a traffics accident incidence installed on the highest point, which improve the safety function on the 'safety way home' for the safety of the community, which due to fire gives alleviate the emotional anxiety of firefighters, which improve the environment for long-term control room working during decision making caused by natural disasters.

$CO_2$ Emission Calculation of D Thermal Power Plant using Performance Test Results (성능시험 결과를 이용한 D발전소의 $CO_2$ 대기배출량 계산)

  • Moon, Hong-Gyu;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.341-344
    • /
    • 2007
  • Kyoto Protocol against global warming came into effect in Feb 2005. Korea is expected to be put under obligation to decrease the $CO_2$ emission from 2013. Because the electric power plants burning fossil fuel occupy 25% of national $CO_2$ emission, calculating the amount is very important. This paper presents ; - a brief procedure of performance test of D thermal power plant - calculation and comparison of $CO_2$ emission of D power plant w.r.t the generator output for LNG and residual oil using the a, b, c coefficients obtained by the performance test - and a brief description on currently used chemical method for calculation of $CO_2$ emission

  • PDF

A Study of Automatic Fire Detection Installation based CAN Comunnication (CAN 통신기반 자동화재탐지설비에 관한 연구)

  • Kim, Young-Dong;Oh, Guem-Kon;Kang, Won-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.50-59
    • /
    • 2006
  • In this paper, We are going to propose the fire protection system using CAN(Controller Area Network). The larger, higher and deeper buildings an, the more dangerous people are when fire happens. We should be aware of the problems of prior fire protection system. Therefore, we construct the embedded system based on CAN communication that is capable of N to N communication, and build independent fire protection system. If the fire is occurred on the building, the problem is that how fast we can detect the fire and put it on by using available system, this is major factor that reduces damage of our wealth. Therefore in this studies, We would like to design more stable system than current system. This system is based on CAN communication which is available N to N communication constructs and designed to compensate for each fault, so that our aim is to reduce the wires of system, cost of installation and to suppose future type fire protection system.

The Online Protective Coordination Schemes of the Distribution Systems with Distributed Generation (분산전원이 연계된 배전계통의 온라인 보호협조 방안)

  • Choi, Joon-Ho;Ro, Kyoung-Soo;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.132-141
    • /
    • 2007
  • Recently, there has been growing interest in distributed resources with high-energy efficiency due to the increasing energy consumption and environmental pollution problems. But an insertion of new distributed generation to existing power distribution systems can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc. In this paper, a new method of the fault location identification at the distribution system with distributed resources, which can be determined by the magnitude and direction of the fault current, is proposed. In addition, a new online protective coordination scheme of recloser-sectionalizer is proposed based on the proposed fault location identification method for distribution system with distributed resources.

A Study on the Improvement of Classifying Method of the Sky Conditions for Application of the Daylight at Indoor - The Comparison with Cloud Amount and Measured Solar Horizontal Irradiation in Seoul - (실내 주광 활용을 위한 천공 구분 방법 개선에 관한 연구 - 서울의 전운량과 측정 일사량의 비교를 통해 -)

  • Kim, Yu-Sin;Kim, Hyun-Sun;Hong, Seong-Kwan;Park, Byoung-Chul;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.19-27
    • /
    • 2010
  • Sky cover method can be used to determine sky condition by cloud amount of the Korea Meteorological Administration. And, HCI (Hourly Clearness Index) method is another method determined by measured horizontal global radiation data. The results of the HCI methods of Erbs et al. (1982), Orgill and Hollands (1977) seem to be not good enough because of the air pollution such as smog phenomenon or yellow sand phenomenon and so on. Therefore, HCI should be corrected. The aim of this study is to improve HCI. Therefore, this study is to analyze and compare on the sky conditions from Sky cover method and HCI, and then presents hourly correction factor based on Sky 채팩 method. The results of corrected HCI improved.

Empirical Approach to Price Modeling in Electricity Market based on Stochastic Process (확률과정론적 기반의 전력시장가격모델링 기법)

  • Kang, Dong-Joo;Kim, Bal-Ho H.
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.95-102
    • /
    • 2010
  • As the electric power industry is evolving into competitive market scheme, a new paradigm is required for the operation of market. Traditional dispatch algorithm was built based on the optimization model with an objective function and multiple constraints. Commercial market simulator followed the concept of the microeconomic model used in the dispatch algorithm, which is called as analytic method. On analytic method it is prerequisite to procure the exact data for the simulation. It is not easy anymore for each market participant to access to other participants' financial information while it used to be easy for monopoly decision maker to know all the information needed for the optimal operation. Considering the changing situation, it is required to introduce a new method for estimating the market price. This paper proposes an empirical method based on stochastic processes expected to build a capacity planning and long term contracts.

Performance Comparison of Skin Color Detection Algorithms by the Changes of Backgrounds (배경의 변화에 따른 피부색상 검출 알고리즘의 성능 비교)

  • Jang, Seok-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.3
    • /
    • pp.27-35
    • /
    • 2010
  • Accurately extracting skin color regions is very important in various areas such as face recognition and tracking, facial expression recognition, adult image identification, health-care, and so forth. In this paper, we evaluate the performances of several skin color detection algorithms in indoor environments by changing the distance between the camera and the object as well as the background colors of the object. The distance is from 60cm to 120cm and the background colors are white, black, orange, pink, and yellow, respectively. The algorithms that we use for the performance evaluation are Peer algorithm, NNYUV, NNHSV, LutYUV, and Kimset algorithm. The experimental results show that NNHSV, NNYUV and LutYUV algorithm are stable, but the other algorithms are somewhat sensitive to the changes of backgrounds. As a result, we expect that the comparative experimental results of this paper will be used very effectively when developing a new skin color extraction algorithm which are very robust to dynamic real environments.

Power Quality Analysis of Jeju System Considering HVDC Overhaul and Wind Turbines (HVDC Overhaul 및 풍력발전을 고려한 제주계통 전력품질 분석)

  • Chae, Woo-Kyu;Yoon, Gi-Gab;Kim, Jae-Eon;Han, Ji-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.132-140
    • /
    • 2008
  • Power system of Jeju is interconnected to the mainland using HVDC and that is also interconnected two wind farms. Control of Jeju power system will be difficult if HVDC is disconnected or HVDC is overhauled under large scale wind farms interconnected. We measured and analysed the power quality of two substation and two wind farms to assess that wind farms and HVDC overhaul have an effect on Jeju system or not during the HVDC overhaul. We found that the frequency of Jeju system is very unstable and the voltage distortion excess the limitation. Harmonic currents of wind farms flew into Jeju system in proportion to the power of wind turbine. And the voltage of nearby distribution line was distorted by power of wind turbine when the amount is more that 3,000[kW].

The Plan on the Seismic Design of Electrical Facility Installed in the Building (건축물에 시설되는 수변전설비 내진설계 방안)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong;Cho, Sung-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Recently life and properties damage at Japan and China by generating earthquake. So earthquake generation trend and damage in the earthquake risk, and these are a growing interest in domestic. This paper analyzes domestic site and problems of earthquake measures for electrical facility at transformer vault which supply the power the emergence situation at generating earthquake. Also we present the seismic design of electrical facility using "Building construction design standard" in internal and "Manual of seismic design and construction for Building Electrical facility" in japan. This paper will be used detail seismic design of pipe and facility, reliability inspection plan for seismic design and construction of electrical facility.

Power Demand Estimation of Consuming Facility using Orthogonal Polynomial Regression Model (직교 다항 회귀모델을 이용한 수용설비의 소비전력 추정)

  • 고희석;이충식;지봉호;김일중
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.75-81
    • /
    • 1999
  • This paper presents in the rrethod power demand estimated of consuming facility algorithm using orthogonal polynomial regression rmdel. Estimation rmdel presented can use mathematical rrethod consists. of extrapolation and correlation rrethod, Computation tirre and capacity of presented rmdel was rmre economic than multiple regression rrodel because low-order equation can use in the high-order equation without sorre correction, and vice-versa. Therefore this rmthed can be very usefulness rmthed in the power demand estimation Fourth-order rrodel was very good armng this rrodel that was coJTJp)Sed the estimation rmdel of second, third and fourth-order. Power demand estimated result of consuming facility using correlation rrethod was good in the percentage error of about 2[%1 Also It was to verify efficiency and awroPJiation the estimated rmdel that estimation percentage error was about 1[%] in the oower demand estimated result of 1997.

  • PDF