• Title/Summary/Keyword: 상황조명

Search Result 352, Processing Time 0.03 seconds

Assessment Software of Hormonic Emission Limits for Transmission System (송전계통 고조파 방출 한계 평가 소프트웨어)

  • Wang, Yong-Peel;Jeong, Jong-Won;Kim, Se-Dong;Kwak, No-Hong;Jeong, Young-Soo;Park, Sang-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.134-140
    • /
    • 2007
  • In recent years, power equipment and system standards have been increasing in both number and complexity. The standards that will soon be introduced to KOREA is the transmission system standards for harmonic emission limits assessing in distorting loads. Utility engineers, being under increasing time constraints, are turning more and more to software to quickly solve problems. This paper describes the methodology used to implement the above standards in Microsoft Excel in order to assist utility engineers to readily apply these standards in practical situations.

A Face Recognition using the Hidden Markov Model and Karhuman Loevs Transform (Hidden Markov Model과 Karhuman Loevs Transform를 이용한 얼굴인식)

  • Kim, Do-Hyun;Hwang, Suen-Ki;Kang, Yong-Seok;Kim, Tae-Woo;Kim, Moon-Hwan;Bae, Cheol-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.1
    • /
    • pp.3-8
    • /
    • 2011
  • The work presented in this paper describes a Hidden Markov Model(HMM)-based framework for face recognition and face detection. The observation vectors used to characterize the statics of the HMM are obtained using the coefficients of the Karhuman-Loves Transform(KLT). The face recognition method presented in this paper reduces significantly the computational complexity of previous HMM-based face recognition systems, while slightly improving the recognition rate. In addition, the suggested method is more effective than the exiting ones in face extraction in terms of accuracy and others even under complex changes to the surroundings such as lighting.

Research about movement character of PV Inverter by distribution line impedance (선로임피던스에 의한 태양광 인버터의 동작특성에 관한 연구)

  • Jeong, Jum-Soo;Yoon, Ki-Kab
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.305-309
    • /
    • 2009
  • This paper operate with variable line impedance equipment consist of resister and reactor, when connect to 3phase induce motor present solve problem appear grid interconnection before/after about voltage transient of pv inverter through test and analysis solve problem.

  • PDF

Navigation of Autonomous Mobile Robot using Fuzzy Neural Network (퍼지-뉴럴 네트워크를 이용한 자율 이동로봇의 운항)

  • Choi, Jeong-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.19-25
    • /
    • 2008
  • This paper proposes a hierarchically structured navigation algorithm for autonomous mobile robot under unknown environment based on fuzzy-neal network. The proposed algorithm consists of two basic layers as follows. The lower layer consists of two parts such as fuzzy algorithm for goal approach and fuzzy-neural algorithm for obstacle avoidance. The upper layer which is basically fuzzy algorithm adjusts the magnitude of the weighting factor depending on the environmental situation. The proposed algorithm provides an efficient method to escape local mimimum points as shown in the simulation result. Most simulation results show that this algorithm is very effective for autonomous mobile robots' traveling in unknown field.

Customer Nodal Cost Calculation considering Power Quality (전력품질을 고려한 수용가 모선 가격 계산)

  • Jeong, Sung-Won;Park, In-Duck;Gim, Jae-Hyeon;Lee, Geun-Joon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.82-87
    • /
    • 2007
  • This paper measures power quality of bus in case electric charges about customer are imposed by each bus, supposed that can calculate this cost. When reflected this in system planning, expected cost proposed following method through sample system. To calculate nodal cost operating condition of power equipment calculates nodal cost[$/MVAH] supposing by situation that is optimized by OPF(optimal power flow) in system. The damage cost that is shed by fault that happen during year of loads in system that is linked on each bus was produced. As a result, proposed method was very effective in case of calculating bus total cost including power quality cost.

Reliability of Distribution System Divided into Community Energy Systems (구역전기사업자로 분리된 배전계통의 신뢰도 평가)

  • Bae, In-Su;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.85-90
    • /
    • 2010
  • This paper presents a technique to evaluate the reliability of customers in Community Energy System(CES). Operators of the CES are responsible for a reliable energy supply to their customers. Due to the strategy of the priority on their customers, the restoration process of DGs should be reordered when system outage happens. The previous study has proposed the technique in the distribution system in which one operator owns all DGs. Case studies in Bus 2 of Roy Billinton Test System(RBTS) verify that the accuracy of the proposed technique is comparable to that of previous technique, and the distribution system divided into several CESs changes the reliability index of customers in the CESs.

Performance Analysis of the GOOSE Transmission of an IED Considering Network Redundancy (네트워크 이중화를 고려한 IED GOOSE 전송에 관한 성능 분석)

  • Lee, Nam-Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.75-80
    • /
    • 2009
  • In order to prevent loss of communication packets and drop of transmission speed owing to the network fault occurrence, it should be considered network redundancy. That is why a messages of IED GOOSE is the critical signal in charge of protection and control of the substation. So most of users implement the substation automation system with Hybrid network topology ant IED supporting double ethernet ports. Because IEC 61850 GOOSE conformance test is limited in the functional test, this paper suggests how to test the performance of IED GOOSE transmission considering Network redundancy, and describes the analysis of an example test on real IEDs and how to impact the IED GOOSE performance to the substation automation system.

An Implementation of a u-Health Service Space Based on Sensor Network (센서 네트워크 기술에 기반한 유헬스 서비스 공간 구현)

  • Ahn, Si-Young;Lee, Tae-Young;Kim, Do-Won;Oh, Ha-Ryoung;Seong, Yeong-Rak;Park, Jun-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2B
    • /
    • pp.225-231
    • /
    • 2010
  • In this paper, a sensor network system for providing u-health services is suggested and is implemented. It steadily collects biological data of resident people and automatically detects emergency situations. LEID (Lighting Embedded Information Device) nodes are the most essential component of the sensor network. They embed sensor network technology into lightening devices which are indispensable to most living spaces. To verify practicality of the proposed u-health system, a prototypical system is realized in the Smart Home Industrialization Support Center at Kookmin University, and is tested within many practical circumstances. The proposed u-health system can be used at various places where many patients are continuously cared.

The Prediction of the Interior Luminous Effect using Computer Graphic Method (CG를 이용한 실내공간 조명연출효과의 예측- 건축화 조명을 중심으로 -)

  • 홍승대
    • Archives of design research
    • /
    • v.14 no.1
    • /
    • pp.135-144
    • /
    • 2001
  • The purpose of this study is to investigate the relationships between apartment residents'satisfaction and preferences and their environments on purpose to provide useful data for developing new apartment environment based on resident's needs and wants. this research was executed through a questionnaire survey method. The major findings are as follows : (1) Preference of large space of apartment dwelling is still prevailing. The older people have the tendency to prefer orientation to vista. (2) Among environmental factors of livingroom, size is mostly ranked higher than vista and orientation. Result of higher ranking of vista than orientation can be explained with the change of life cycle and patterns based on social environmental change and development of environmental control systems. (3) The highest concern about interior design is targeted to livingroom, and quality of finish materials is preferred at the highest.

  • PDF

Total monitoring device of leakage current in transformer (변압기 누설전류 통합 감시장치)

  • Lee, Jung-Eun;Choi, Hong-Kyoo;Yum, Sung-Bae;Park, Hyung-Min;Yoo, Hai-Chool;Hong, Seong-Goo;Shin, Hye-Young
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.360-363
    • /
    • 2009
  • Total monitoring device of leakage current in transformer can detects the flowing leakage current on the neutral line, and that is monitored at real-time by the transfer. If the over-flowing current is detected Total monitoring device of leakage current in transformer will warn the administrator to prevent electrical accident. In this thesis, we are going to explain about Total monitoring device of leakage current in transformer and the necessity of Total monitoring device of leakage current in transformer through real-accident cases and equipment condition in Korea.

  • PDF