• Title/Summary/Keyword: 상호작용 다중필터

Search Result 15, Processing Time 0.02 seconds

Performance Evaluation of the Modified Interacting Multiple Model Filter Using 3-D Maneuvering Target (3차원 기동표적을 사용한 수정된 상호작용 다중모델필터의 성능 분석)

  • Park, Sung-Lin;Kim, Ki-Cheol;Kim, Yong-shik;Hong, Keum-Shik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.5
    • /
    • pp.445-453
    • /
    • 2001
  • The multiple targets tracking problem has been one of the main issues in the radar applications area in the last decade. Besides the standard Kalman filtering, various methods including the variable dimen-sion filter, input estimation filter, interacting multiple model(IMM) filter, dederated variable dimension filter with input estimation, etc., have proposed to address the tracking and sensor fusion issues. In this pa- per, two existing tracking algorithm, i.e, the IMM filter and the variable dimension filter with input estima-tion(VDIE), are combined for the purpose of improving the tracking performance for maneuvering targets. To evaluate the tracking performance of the proposed algorithm, three typical maneuvering patterns, i.e., waver, pop-up, and high-diver motions, are defined and are applied to the modified IMM filter as well as the standard IMM filter. The smaller RMS tracking errors, in position and velocity, of the modified IMM filter than the standard IMM filter are demonstrated though computer simulations.

  • PDF

Radome Slope Estimation using Mode Parameter Renewal Method of IMM Algorithm (IMM 알고리듬의 모드 계수 갱신 방법을 통한 레이돔 굴절률 추정)

  • Kim, Young-Mo;Back, Ju-Hoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.763-770
    • /
    • 2017
  • A radome mounted on the front of an aircraft can cause refraction errors for various reasons that occur during maneuver in seeking and tracking a target. This refraction error means that the microwave seeker is detecting apparent target. An Interactive Multiple Model (IMM) algorithm is applied to estimate radome slope mounted on an aircraft in 3D space. However, even though the parameter of uncertain system model such as radome slope can be estimated, the estimated performance can not be guaranteed when it exceeds the range of the predicted value. In this paper, we propose a method to update the predicted value by using the radome slope as the mode parameter of the IMM algorithm, and confirm the radome slope estimation performance of the proposed method.

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

Technology Development for Non-Contact Interface of Multi-Region Classifier based on Context-Aware (상황 인식 기반 다중 영역 분류기 비접촉 인터페이스기술 개발)

  • Jin, Songguo;Rhee, Phill-Kyu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.175-182
    • /
    • 2020
  • The non-contact eye tracking is a nonintrusive human-computer interface providing hands-free communications for people with severe disabilities. Recently. it is expected to do an important role in non-contact systems due to the recent coronavirus COVID-19, etc. This paper proposes a novel approach for an eye mouse using an eye tracking method based on a context-aware based AdaBoost multi-region classifier and ASSL algorithm. The conventional AdaBoost algorithm, however, cannot provide sufficiently reliable performance in face tracking for eye cursor pointing estimation, because it cannot take advantage of the spatial context relations among facial features. Therefore, we propose the eye-region context based AdaBoost multiple classifier for the efficient non-contact gaze tracking and mouse implementation. The proposed method detects, tracks, and aggregates various eye features to evaluate the gaze and adjusts active and semi-supervised learning based on the on-screen cursor. The proposed system has been successfully employed in eye location, and it can also be used to detect and track eye features. This system controls the computer cursor along the user's gaze and it was postprocessing by applying Gaussian modeling to prevent shaking during the real-time tracking using Kalman filter. In this system, target objects were randomly generated and the eye tracking performance was analyzed according to the Fits law in real time. It is expected that the utilization of non-contact interfaces.

Interference Pattern Analysis in the Optical CDMA system using the SCAE and SCAD (SCAE와 SCAD를 이용한 광 CDMA시스템에서 간섭패턴 분석)

  • Kang, Tae-Gu;Choi, Jae-Kyong;Park, Chan-Young;Choi, Young-Wan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.1
    • /
    • pp.44-51
    • /
    • 2000
  • We have analyzed optical matched filters considering the third order signals in the optical code division multiple access (CDMA) system based on optical series coupler access encoder (SCAE) and series coupler access decoder (SCAD). In previous studies, the performance evaluation of the optical CDMA system using SCAE and SCAD was not sufficiently accurate because they analyzed system performance only considering the first order signals. Since optical SCAE and SCAD intrinsically have high order signals of various patterns as the number of coupler increases, they change auto- and cross-correlation intensities. Thus, it is necessary to investigate properties of the third order signals so that we may analyze the exact performance of system. In this paper, we mathematically interpret the optical signals up to the third order, and analyzed the effects of th third order signals on auto- and cross-correlation intensities. In result, as ${\alpha}$(coupling coefficient) value increases, the intensity of the third order signals increases. It is found that the peak to side-lobe ratio considering the third order signals is degraded by 3.75 dB at N(coupler number)=5 and ${\alpha}$=0.5. Also if threshold value in receiver is set by main-lobe peak of the first order signals, it is found that the number of users in an optical CDMA system is limited because the intensity peak of side-lobes is raised by the third order signals.

  • PDF