A Prediction of Behavior of Granular Soils Based on the Advanced Elasto Plastic Model (개선된 탄.소성 구성모델을 이용한 사질토의 응력-변형률 거동예측)

  • Park, Byeong-Gi;Im, Seong-Cheol;Lee, Gang-Il
    • Geotechnical Engineering
    • /
    • v.11 no.3
    • /
    • pp.81-90
    • /
    • 1995
  • Based on the close investigation of Lade elasto -plastic model, this study proposes a new elasto -plastic constitutive model for foundation composed of granular soils. The new model contains 1st stress invariant in plastic potential function as well as yield function, which is different from Lade original model. Both these functions called a correction function include a correction term. To validate the new analytical model, it was compered with some previous models. Comparison between the test results and numerical results using Lade and new model was carried out concerning Sacramento River sand, U.S.A and Backma River sand. The conclusion was obtained that more refined model well be deft.eloped throughout this research.

  • PDF

Nondestructive Interfacial Evaluation and Cure Monitoring of Carbon Fiber/Epoxyacrylate Composite with UV and Thermal Curing Using Electro-Micromechanical Technique (Electro-Micromechanical 시험법을 이용한 탄소 섬유 강화 에폭시아크릴레이트 복합재료의 자외선과 열경화에 따른 경화 모니터링 및 비파괴적 계면 평가)

  • 박종만;공진우;김대식;이재락
    • Polymer(Korea)
    • /
    • v.27 no.3
    • /
    • pp.189-194
    • /
    • 2003
  • Interfacial evaluation, damage sensing and cure monitoring of single carbon fiber/thermo setting composite with different curing processes were investigated using electro-micromechanical test. After curing, the residual stress was monitored by measurement of electrical resistance and then compared to various curing processes. In thermal curing case, matrix tensile strength, modulus and interfacial shear strength were higher than those of ultraviolet curing case. The shrinkage measured during thermal curing occurred significantly by matrix shrinkage and residual stress due to the difference in thermal expansion coefficient. The apparent modulus measured in the thermal curing indicated that mechanical and interfacial properties were highly improved. The reaching time to the same stress of thermal curing was faster than that of UV curing case.

Development of the Nondestructive Methods to Detect Voids under Concrete Slabs Using Wave Analysis (파동해석법을 이용하여 콘크리트 슬래브 하부의 공동을 찾는 비파괴 시험법의 개발)

  • Kim, Yongon;Kim, Y. Richard
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.1
    • /
    • pp.108-120
    • /
    • 1998
  • 많은 주거용 및 상업용 건물에서 콘크리트 구조물이 사용되고 있는데 콘크리트 슬래브 아래의 기초부분에 공동이 생기는 경우가 종종 발견되었다. 이 현상은 진동하중, 반복되는 충격, 흙의 유실, 혹은 불량시공 등 여러가지 이유에 의해 발생할 수 있다. 이러한 현상은 구조물의 지지력을 저하시키고 결국 수명을 단축시키는 원인이 되므로 이러한 문제는 일찍 발견되고 조치가 취해질수록 구조물의 수명을 연장시킬 수 있을 것이다. 이러한 공동이 슬래브 아래에서 형성되고 커져가는 과정을 모니터할 수 있으면 현재 상태에서 지지력을 결정하고 또한 앞으로 남은 수명을 예측함으로써 적절한 유지보수계획을 세우는 데에 큰 도움이 될 것이다. 이 연구에서는 음파와 응력파, 특히 표면파가 슬래브 아래의 공동을 찾아내는데 이용되었고 두 가지 방법의 효과가 상호 비교되었다. 두개의 콘크리트 슬래브를 만들어 이용했는데 하나는 미리 공동이 만들어져 있었고 다른 하나에는 공동이 없었다. 공동이 없던 슬래브는 처음 손상안된 상태에서 실험을 한 후 나중에 하부에 공동을 만들어 다시 실험하였다. 실험결과와 실제 공동의 위치가 잘 일치되는 것으로 나타났다. 응력파를 이용하는 방법과 음파를 이용하는 방법사이의 장단점이 비교검토되었고 실험의 표준방법과 결과에 대한 일반적인 기준이 확립되어야 하는 필요성에 대해서도 설명되었다.

  • PDF

Development of XML-based Material Database for Plant Facilities Maintenance (XML을 이용한 플랜트 재료 데이터베이스 개발 및 활용)

  • 장동식;김의현;정진성;공희경
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04b
    • /
    • pp.1-3
    • /
    • 2004
  • 산업설비 현장에서는 설비 운영과 관련하여 재료 관련 정보에 대한 요구가 비교적 빈번하게 발생하고 있으나 필요한 기술 자료의 확보, 검토 등에 많은 어려움을 겪고 있다. 따라서 산업설비에 적용되는 재료들을 종합하여 비교, 검토할 수 있는 시스템을 개발하여 인터넷을 통해 제공할 경우 산업설비의 운영효율 향상, 신뢰도 향상에 기여할 수 있을 것으로 기대된다. 재료 데이터베이스 시스템은 재료가 사용되는 설비의 운영과 관련한 각종 데이터와 상호 연계되어야 할 필요가 있다. 손상해석, 재료선정 등은 인장시험 등 각종 시험 데이터와 더불어 재료가 사용되는 실제 설비의 응력. 온도 등 운전환경, 사용이력 등이 중요한 판단 자료가 되기 때문이다. 또한 재료 데이터는 플랜트 운영시스템, 자재구매/관리시스템 등 다양한 시스템의 기본 마스터데이터로 이용들 수 있다. 따라서 재료 데이터가 갖는 이러한 특성을 충족시키기 위해서는 확장성과 이식성이 뛰어난 XML을 기반으로 재료 데이터베이스를 개발하는 것이 바랑직할 것으로 판단된다. XML을 기반으로 개발된 재료 데이터베이스는 20,000건의 방대한 재료 규격정보를 담고 있으며 규격검색, 이름검색, 화학성분 검색, 기계적 특성 검색 등 다양한 검색 기능을 제공한다. 또한 대표적인 종합플랜트인 화력발전소의 설iii데이터와 통할 연동되어 재료의 적용현황 및 환경 등을 통합적으로 검색할 수 있다. XML을 이용한 본 개발시스템은 향후 상용 ERP 패키지 다양한 시스템의 기본 데이터베이스로 활용될 수 있을 것으로 기대된다.

  • PDF

Characteristics of Electrochemical and Cavitation Damage after Sealing Treatment for Arc Thermal Sprayed Coating Layer (후처리된 아크 용사코팅 층의 전기화학적 및 캐비테이션 손상 특성)

  • Kim, Seong-Jong;Han, Min-Su;Park, Il-Cho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.300-300
    • /
    • 2014
  • 해양환경 하에서 대형 강구조물의 경우 장기간 부식손상을 방지하기 위해 아크 용사코팅 기술이 오래전부터 유용하게 이용되어 왔다. 아크 용사코팅 기술은 타 용사코팅 기술에 비해 경제성과 생산성이 뛰어나 대형 강구조물에 적용되고 있다. 용사재료로는 Al, Zn 또는 그 합금들이 주로 사용되어 강재에 대해 희생양극 방식효과를 나타낸다. 그러나 아크용사에 의해 적층된 코팅 층은 용사공정 중 불가피하게 수많은 기공과 산화물이 포함되어 내식성 및 내구성에 악영향을 미치게 된다. 따라서 본 연구에서는 알루미늄 합금의 용사코팅 층에 대하여 다양한 후처리를 통해 내식성과 더불어 내구성을 향상시키고자 하였다. 용사코팅은 알루미늄 합금 선재(1.6 ${\varnothing}$)를 사용하여 아크용사를 실시하였다. 용사 시 용사거리는 200 mm, 공기압력은 약 $7kg/cm^2$ 정도로 유지하면서 용사코팅을 실시하여 약 $200{\mu}m$ 두께로 코팅 층을 형성시켰다. 이후 용사코팅 층의 표면에 다양한 후처리재를 적용하였으며, 내구성을 평가하기 위하여 후처리 적용 전후 시험편에 대하여 캐비테이션 실험을 실시하였다. 캐비테이션 실험은 ASTM G32-92에 의거하여 주파수 20 kHz의 초음파 진동 장치(ultrasonic vibratory device)를 사용하였다. 그리고 시험편 표면과 발진 혼에 부착된 팁(tip)과의 거리는 1 mm로 일정하게 유지시킨 뒤, 캐비테이션 발생 시간을 변수로 하여 실험을 실시하였다. 손상된 용사코팅 층의 표면은 주사전자현미경과 광학현미경으로 관찰하였으며, 시험편 손상깊이는 3D 현미경으로 비교 분석하였다. 또한 캐비테이션 실험 전후의 무게를 측정하여 무게 감소량을 상호 비교하였다. 그리고 전기화학적 실험은 천연해수 속에서 자체 제작한 홀더(holder)를 이용하여 $0.33183cm^2$의 용사코팅 층만을 노출시켜 실시하였다. 그리고 기준전극은 은/염화은 전극을, 대극은 백금전극을 사용하였다. 분극실험을 통해 후처리 적용에 따른 용사코팅 층의 부식전위 및 부식전류밀도를 비교 평가하였다. 그 결과, 용사코팅 층에 의하여 강재에 대한 희생양극 방식전위가 확보되었으며, 후처리재가 적용된 용사코팅 층에서 내식성 및 캐비테이션 저항성이 향상되었다.

  • PDF

A Study on the Stress Corrosion Cracking Propagation Behaviors of high Strength Steel by Means of Emission Test (음향방출시험에 의한 고장력강의 응력부식 균열전파 거동에 관한 연구)

  • Yu, Hyo-Seon;Jeong, Se-Hui
    • Korean Journal of Materials Research
    • /
    • v.3 no.4
    • /
    • pp.361-371
    • /
    • 1993
  • Among the various test methods for stress corrusiun cracking(SCC) susceptibility evaluatiun, the slow stram rate test(SSHT) method is a rapid and effective nwthod to evaluate the SCC susceptibility of metal in relatively short time. But it is very difficult to analyze the microfracture behaviors in SCC process by using the test(SSRT) method only. Up to now, it has been well known that the acoustic emission(AE) test is the effective technique to monitor the microcrack initiation and propagation in material fracture pmcess. Therefore. in this paper, we analyzed the correlation between the see process and the characteristics of AE signal by using the SSHT and the AE test. According to the test results. the AE signals produced from the material microfracture were clearly depended on the test environment. The AE signal characteristics generated during see process in synthetic sea water were comparatively greater than those. in air. In addition, the SCC behaviors could be definitely evaluated by the amplitude parameter of AE signals.

  • PDF

An Investigation of Fluid Mixing with Direct Vessel Injection (직접용기주입에 따른 유체혼합에 관한 연구)

  • Cha, Jong-Hee;Jun, Hyung-Gil
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.63-77
    • /
    • 1994
  • The objective of this work is to investigate fluid mixing phenomena related to pressurized thermal shock(PTS) in a pressurized water reactor(PWR) vessel downcomer during transient cooldown with direct vessel injection(DVI) using test models. The test model designs were based on ABB Combustion Engineering(C-E) System 80+ reactor geometry. A cold leg small break loss-of-coolant accident(LOCA) md a main steam line teak were selected as the potential PTS events for the C-E System 80+. This work consist of two parts. The first part provides the visualization tests of the fluid mixing between DVI fluid and existing coolant in the downcomer region, and the second part is to compare the results of thermal mixing tests with DVI in the other test model. Row visualization tests with DVI have clarified the physical interaction between DVI fluid and primary coolant during transient cooldown. A significant temperature drop was observed in the downcomer during the tests of a small break LOCA Measured transient temperature profiles agree well with the predictions by the REMIX code for a small break LOCA and with the calculations by the COMMIX-1B code for a steam line break event.

  • PDF

Regulation in Shear Test Method for BGA of Flip-chip Packages (플립칩 패키지 BGA의 전단강도 시험법 표준화)

  • Ahn, Jee-Hyuk;Kim, Kwang-Seok;Lee, Young-Chul;Kim, Yong-Il;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.3
    • /
    • pp.1-9
    • /
    • 2010
  • We reported the methodology for the shear test which is one of the evaluation procedure for mechanical reliability of flip-chip package. The shear speed and the tip height are found to be two significant experimental parameters in the shear test. We investigated how these two parameters have an influence on the results, the shear strength and failure mode. In order to prove these experimental inconsistency, simulation using finite element analysis was also conducted to calculate the shear strength and to figure out the distribution of plastic energy inside of the solder ball. The shear strength decreased while the tip height increased or the shear speed decreased. A variation in shear strength due to inconsistent shear conditions made confusion on analyzing experimental results. As a result, it was strongly needed to standardize the shear test method.

Techniques Using MUIO and shortest Path(MUSP) and Multiple Unique State (MUSS) for Aynchronizable Test Swquence Genration (동기화된 시험순서를 생성하기 위한 개선된 시험 생성 방법)

  • Jeong, Yun-Hui;Hong, Beom-Gi
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.3
    • /
    • pp.767-774
    • /
    • 1997
  • A procedure presented in this paper greerates test squences to check the conformity of an implementation wihh a protocol specification which is moedled as a determinstic fimite state machine(FSM).We proposed a tech-nique to determine a minium-cost tour of the transition graph of the FSM..The technique using Multiple UIO and Shortest Path(MUSP) sabes the cost 1-9% over MUIO and directly, derive a symertric test graph from an FSM graph From this fact, we proposed a tecuque using Multiple Sate Suganture(MUSS) to solve an open issue that the multiple UIO assignment may not minimize the lengy of the tour.In this paper, the proposed techique is also, applied to generate a synchronizable test wequence.And the result shows that the techique using MUSP anhd MUSS saves the cost 7-29% and 7-42% over the previous approach using MUIO, respect-ively.

  • PDF

Nondestructive Damage Sensitivity of Carbon Nanotube and Nanofiber/Epoxy Composites using Electro- Micromechanical Technique and Acoustic Emission (전기적-미세역학 시험법과 음향 방출을 이용한 탄소 나노튜브와 나노섬유 강화 에폭시 복합재료의 비파괴 손상 감지능)

  • 김대식;박종만;김태욱
    • Polymer(Korea)
    • /
    • v.28 no.4
    • /
    • pp.285-290
    • /
    • 2004
  • Nondestructive damage sensitivity of carbon nanotube(CNT) and nanofiber (CNF)/epoxy composites with their adding contents was investigated using electro-micromechanical technique. Carbon black (CB) was used only for the comparison with CNT and CNF. The fracture of carbon fiber was detected by acoustic emission (AE), which was correlated to the change in electrical resistance, ΔR under double-matrix composites (DMC) test. Stress sensing on carbon nanocomposites was performed by electro-pullout test under uniform cyclic loading. At the same volume fraction, the damage sensitivity for fiber fracture, matrix deformation and stress sensing were highest for CNT/epoxy composite, whereas for CB/epoxy composite they were the lowest among three carbon nanomaterials (CNMs). Damage sensitivity was correlated with morphological observation of carbon nanocomposites. Homogeneous dispersion among CNMs could be keying parameters for better damage monitoring. In this study, damage sensing of carbon nanocomposites could be evaluated well nondestructively by the electrical resistance measurement with AE.