• Title/Summary/Keyword: 상태 변화 예측

Search Result 1,014, Processing Time 0.024 seconds

Utilization of Smart Farms in Open-field Agriculture Based on Digital Twin (디지털 트윈 기반 노지스마트팜 활용방안)

  • Kim, Sukgu
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2023.04a
    • /
    • pp.7-7
    • /
    • 2023
  • Currently, the main technologies of various fourth industries are big data, the Internet of Things, artificial intelligence, blockchain, mixed reality (MR), and drones. In particular, "digital twin," which has recently become a global technological trend, is a concept of a virtual model that is expressed equally in physical objects and computers. By creating and simulating a Digital twin of software-virtualized assets instead of real physical assets, accurate information about the characteristics of real farming (current state, agricultural productivity, agricultural work scenarios, etc.) can be obtained. This study aims to streamline agricultural work through automatic water management, remote growth forecasting, drone control, and pest forecasting through the operation of an integrated control system by constructing digital twin data on the main production area of the nojinot industry and designing and building a smart farm complex. In addition, it aims to distribute digital environmental control agriculture in Korea that can reduce labor and improve crop productivity by minimizing environmental load through the use of appropriate amounts of fertilizers and pesticides through big data analysis. These open-field agricultural technologies can reduce labor through digital farming and cultivation management, optimize water use and prevent soil pollution in preparation for climate change, and quantitative growth management of open-field crops by securing digital data for the national cultivation environment. It is also a way to directly implement carbon-neutral RED++ activities by improving agricultural productivity. The analysis and prediction of growth status through the acquisition of the acquired high-precision and high-definition image-based crop growth data are very effective in digital farming work management. The Southern Crop Department of the National Institute of Food Science conducted research and development on various types of open-field agricultural smart farms such as underground point and underground drainage. In particular, from this year, commercialization is underway in earnest through the establishment of smart farm facilities and technology distribution for agricultural technology complexes across the country. In this study, we would like to describe the case of establishing the agricultural field that combines digital twin technology and open-field agricultural smart farm technology and future utilization plans.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

Chronic HBV Infection in Children: The histopathologic classification and its correlation with clinical findings (소아의 만성 B형 간염: 새로운 병리조직학적 분류와 임상 소견의 상관 분석)

  • Lee, Seon-Young;Ko, Jae-Sung;Kim, Chong-Jai;Jang, Ja-June;Seo, Jeong-Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.1 no.1
    • /
    • pp.56-78
    • /
    • 1998
  • Objective: Chronic hepatitis B infection (CHB) occurs in 6% to 10% of population in Korea. In ethinic communities where prevalence of chronic infection is high such as Korea, transmission of hepatitis B infection is either vertical (ie, by perinatal infection) or by close family contact (usually from mothers or siblings) during the first 5 years of life. The development of chronic hepatitis B infection is increasingly more common the earlier a person is exposed to the virus, particularly in fetal and neonatal life. And it progress to cirrhosis and hepatocellular carcinoma, especially in severe liver damage and perinatal infection. Histopathology of CHB is important when evaluating the final outcomes. A numerical scoring system which is a semiquantitatively assessed objective reproducible classification of chronic viral hepatitis, is a valuable tool for statistical analysis when predicting the outcome and evaluating antiviral and other therapies. In this study, a numerical scoring system (Ludwig system) was applied and compared with the conventional histological classification of De Groute. And the comparative analysis of cinical findings, family history, serology, and liver function test by histopathological findings in chronic hepatitis B of children was done. Methods: Ninety nine patients [mean age=9 years (range=17 months to 16 years)] with clinical, biochemical, serological and histological patterns of chronic HBV infection included in this study. Five of these children had hepatocelluar carcinoma. They were 83 male and 16 female children. They all underwent liver biopsies and histologic evaluation was performed by one pathologist. The biopsy specimens were classified, according to the standard criteria of De Groute as follows: normal, chronic lobular hepatitis (CLH), chronic persistent hepatitis (CPH), mild to severe chronic active hepatitis (CAH), or active cirrhosis, inactive cirrhosis, hepatocellular carcinoma (HCC). And the biopsy specimens were also assessed and scored semiquantitatively by the numerical scoring Ludwig system. Serum HBsAg, anti-HBs, HBeAg, anti-HBe, anti-HBc (IgG, IgM), and HDV were measured by radioimunoassays. Results: Male predominated in a proportion of 5.2:1 for all patients. Of 99 patients, 2 cases had normal, 2 cases had CLH, 22 cases had CPH, 40 cases had mild CAH, 19 cases had moderate CAH, 1 case had severe CAH, 7 cases had active cirrhosis, 1 case had inactive cirrhosis, and 5 cases had HCC. The mean age, sex distribution, symptoms, signs, and family history did not differ statistically among the different histologic groups. The numerical scoring system was correlated well with the conventional histological classification. The histological activity evaluated by both the conventional classification and the scoring system was more severe as the levels of serum aminotransferases were higher. In contrast, the levels of serum aminotransferases were not useful for predicting the degree of histologic activity because of its wide range overlapping. When the histological activity was more severe and especially the cirrhosis more progressing, the prothrombin time was more prolonged. The histological severity was inversely related with the duration of seroconversion of HBeAg. Conclusions: The histological activity could not be accurately predicted by clinical and biochemical findings, but by the proper histological classification of the numerical scoring system for the biopsy specimen. The numerical scoring system was correlated well with the conventional histological classification, and it seems to be a valuable tool for the statistical analysis when predicting the outcome and evaluating effects of antiviral and other therapies in chronic hepatitis B in children.

  • PDF

Role of Invasive Procedures in the Diagnosis and Management of Pulmonary Infiltrates in Patients with Leukemia (백혈병 환자에서 발생한 폐침윤의 진단 및 치료에 있어 침습적 검사의 역할)

  • Kang, Soo-Jung;Park, Sang-Joon;An, Chang-Hyeok;Ahn, Jong-Woon;Kim, Ho-Cheol;Lim, Si-Young;Suh, Gee-Young;Kim, Ho-Joong;Kwon, O-Jung;Lee, Hong-Ghi;Rhee, Chong-H.;Chung, Man-Pyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.448-463
    • /
    • 2000
  • Background : Pulmonary infiltrate is a frequent cause of morbidity and mortality in patients with leukemia. It is often hard to obtain a reliable diagnosis by clinical and radiologic findings alone. The aim of this study was to evaluate diagnostic and therapeutic benefits of invasive procedures for new lung infiltrates in leukemia. Methods : Patients with leukemia who developed new lung infiltrates from December 1994 to March 1999 were included in this study. These patients were classified into the empirical group who received empirical therapy only and into the invasive group who underwent bronchoscopy or surgical lung biopsy for the diagnostic purpose of new lung infiltrates. A retrospective chart review was done to find the etiologies of new lung infiltrates, the yield of invasive procedures, outcome as well as predicting factors for survival. Results : 1) One hundred-two episodes of new lung infiltrates developed in 90 patients with leukemia. Invasive procedures were performed in 44 episodes while 58 episodes were treated with empirical therapy only. 2) Invasive procedures yielded a specific diagnosis in 72.7%(32/44), of which 78.1% had infectious etiology. Therapeutic plan was changed in 52.3%(23/44) of patients after invasive procedures. None of them showed procedure-related mortality. 3) The overall survival rate was 62.7%(64/102). Survival rate in the invasive group (79.5%) was significantly better than that in the empirical group (50.0%) (p=0.002). 4) Upon multivariate analysis, the performance of invasive procedures, no need for mechanical ventilation and achievement of complete remission of leukemia after induction chemotherapy were the independent predicting factors for survival in patients with leukemia and new lung infiltrates. Conclusion : Bronchoscopy and surgical lung biopsy are useful in the diagnosis of new lung infiltrates in patients with leukemia. However, survival benefits of invasive procedures should be considered together with disease status of leukemia and severity of respiratory compromise.

  • PDF